We've observed some burn marks on the shielding of the ETMy ring heater cables which occured sometime during the 3 prior weld sessions (May 2012, Dec 2013, Jan 2014). The burns are on the lowest ring heater cable that laces around the test mass and makes a connection between the test mass and the PUM. There is a burn on the right segment and the left segment. I dug up a picture that shows that the burn on the "right" segment (as viewed from the back of the suspension) was there just after the May 2012 weld session, so that one is not new. However the "left" cable burn is new from the Dec or Jan welding. We did not see when this actually occured.
Filiberto tested the ring heater cable and found that all pins are operating as per spec, although he thinks pin 1 is shorting. We are tracking down what this means (did we test it correctly, when was it last tested, is it possible that the burn is contributing to the short, even though it does not look like it is, etc.).
I'm making a measurement of the ITMX direct reflected beam size on ISCT1. PRM is misaligned, sending the beam to the parking dump for this mesurement. Please do not align PRM as this will make the REFL beam too powerful for the beam analyzer and may fry it.
I'm done for now making measurements with PRM misaligned. I'll realign PRM now and measure the PRM direct reflected beam
Output power is 29.3 W (should be around 30 W) FRONTEND WATCH is green HPO WATCH is red SysStat is good PMC has been locked 1 day, 16 hr (should be days/weeks) Reflected power is 10.9% of transmitted power (should be <= 10%) FSS has been locked for 10 min (should be days/weeks) Resonant threshold is .5V (should be .9V) ISS diffracted power is around 8.8% (should be 10%) Last saturation event was 16 min ago (should be days/weeks)
Stefan, Kiwamu
As a part of the beat noise study, we locked the main infrared laser to the X arm cavity by feeding the reflection signal back to the MC length.
Although we succeeded in locking the IR, the beatnote tonight was not great at all. It was roughly 500 Hz / sqrtHz in a band from 1 to 900 Hz when the infrared was locked. Plus, the mode hopping was so frequent that I was not able to integrate the spectrum lower than 1 Hz.
IR locking to the X arm:
Because the green light tonight was not stable enough for us to do the CARM hand off, we instead started locking the IR to the X arm. This is the first time for us to directly lock the infrared main laser to an arm cavity without an aid of the ALS technique. We started this from estimating the PDH optical gain of REFLAIR_RF9 by simply looking at the free swinging wave form. According to Alxea's math (alog 7054), we got ~ 1.21 counts/Hz for the optical gain. Also the MC2 M3 stage was approximated to be 18.2 / f^2 Hz / counts. Using these two information, we set the LSC gain to be 0.46 as an initial guess. Note that we cranked up the whitening gain of REFLAIR9 to its maximum. The demod phase was also adjusted to maximized the PDH signal in in-phase. We then fed it back to MC2.
A good servo gain was then empirically found to be about -0.2. Even though we didn't have a transmitted DC or reflected DC signal, we could tell if we grabbed a sideband resonance or carrier resonance by looking at the size of the Q-signal. This allowed us to detemie the right control sign.
The locking procedure is as follows:
One major difficulty we had during the IR lock was that a mechanical resonant mode at 41 Hz (bounce? roll? of MC2) rang up so much that we could not keep locking the IR. We often let the IMC alone to allow it to settle down for a while and this helped a lot. Also Stefan could introduce the additive offset path on top of the MC length control. He had to crank up the input gain of both common mode board and IMC board to the maximum of 31 dB. It seems that we could still go higher although we didn't quantitatively evaluate it yet. This additive offset technique should serve as a good mitigation for this 41 Hz mode issue while maintaining a high control bandwidth.
The attached is a screen shot of the IR locking configuration.
Noise of the green beatnote was far from good:
The noise performance of the green beatnote was not great. Something must be wrong. The smallest noise floor I could get was approximately 500 Hz/sqrtHz in a band from 1 Hz to 900 Hz. I tried not include a mode hop during the spectrum integration. Even so, as you can see in the attached spectrum, it was suspiciously flat. I used H1:ALS-C_COMM_PLL_CTRL for measuring the beat noise. The calibration was done by injecting a known RF frequency into the PLL and measuring the ADC counts. It was measured to be 7.916 Hz/counts. Also I added a z40/p1.6 filter to cancel the VCO response.
Additional Note:
PRM is currently in its parking position to avoid a power-recycling fringe at the reflection port.
I noticed that IM4trans S1 and S2 channels were saturated, probably after the power increase (similar to the case for IMC WFS noted in entry 9094).
I adjusted the whitening gain down from 45dB to 36dB, which brought segments S1 and S2 down from the rails. IM4trans signal looks better now.
following the failure of one of the three cooling units in the MSR, as a precaution against a second failure we are keeping the hallway doors open and a fan running overnight.
Stefan, Kiwamu
We found that the ISS diffracted light had been high at 24%. According to the trend, it looks that both PD_A and PD_B suddenly got an offset of about 0.5-ish volt and it pushed the diffraction ratio to the high value. The jump happened at around 9:41 local in this morning. Neither Keita nor Yuta was at around the ISC/PSL rack at this specific time. At this point it is unclear what happened or what might have triggered it. The attached is the trend showing the funny jump which also decreased the carrier power everywhere.
For now, we changed the reference offset to bring it to approximately 9%. The new reference offset is:
H1:PSL-ISS_REFSIGNAL -2.31548
A further investigation is needed.
8:30–9:00 Going into the LVEA to work on dust monitor – Patrick 9:01 PSL Check List done (noticed the ISS Diffracted Power was Close to 24% - It should be 5-15%) 9:00–10:30 Water Ground staff on site for water sampling – Hanford 9:27–10:03 Back in the LVEA to swap dust monitor power supply–Patrick 9:36- Starting Initial Alignment of Ham 4 optical table- Hugh 9:41 PSL Check List done (noticed the ISS Diffracted Power was close to 24% - It should be 5-15%) 9:49–12:06 Working on ACB in LVEA West Bay – Mitchell/Scott 13:05-13:59 Back to work on ACB in LVEA West Bay – Mitchell/Scott 13:10-15:14 Periscope assembly on H2 PSL – Joe 13:46-14:48 Installing Tablecloth bracket on SR2 (LVEA) – Jeff B. 13:50-15:14 Joining Joe for periscope assembly on H2 PSL – Craig/Sam 15:00 Safety Meeting
Left LVEA ~1745
This afternoon I went to ISCT1 to begin setting up for the beam size measurements that we hope to use to diagnose the PRC mode matching situation (see LIGO-T1400013).
I took the beam analyzer cart from the optics lab out to ISCT1 and left it set up there. I measured beam powers in two locations just after the REFL periscope: one in reflection of the pick off window directly after the lower periscope mirror, and one after. Since we aim to measure two beams in the REFL path with powers differing by a factor ~4000 it's useful to have low and high attenuation locations. The window is not AR coated so there are two beams visible in reflection. I measured the power of one to be 890uW, and the other to be 800uW, with the low-power head on the VEGA power meter. The beam in transmission of the window was measured to be 123mW. I left the table with the window reflected beam dumped, and the photon inc. beam analyzer behind the dump.The window transmitted beam is still dumped on the shutter.
I just looked for the beam in the same locations with PRM misaligned (sending direct PRM reflection to the parking dump). This should be the beam transmitted through PRM, reflected off ITMX, transmitted through PRM again and sent on to ISCT1. The good news is, the beam was still nice and visible on the IR card after the pick-off window
I tried to measure the power at that location with the same power meter as before, expect with the filter out. Due to the X-arm work going on, the beam was finging quite a bit in the IR, so I couldn't get a very solid reading. It looked like around 50uW on average, with a peak value of ~80uW. Comparing this with the PRM aligned value it seems a little high. The PRM misaligned beam should be roughly T_PRM^2 * T_BS^2 = 2.25e-4 times the PRM aligned beam. This means I would have expected 123mW*2.25e-4 = 28uW. Maybe some of the green light was leaking in, or maybe the X-arm flashes were confusing the power meter... it will be easier to get a good measurement here with ETMX and ITMY misaligned later. I can't take beam profile measurements until then anyway.
We are trying to record the frequency of the ifr, but there is a 4Hz offset between the EPICS readback and the value reported by dataviewer and/or saved by the DAQ.
Looks like a dataviewer/xmgr problem. When plotting this data using diaggui we get the correct value.
the eagle eyed amongst you will have noticed the root plot Y-axis doesn't look correct. The data line is 2256 but the Y-range is actually 2260 to 2270 suggesting the data is 2260 (as xmgr showed it). Jim ran command line nds client on this channel and confirmed the DAQ is recording the correct frequency of 24992256Hz. Unfortunately both xmgr and root seem to have plotting problems with static numbers of this magnitude.
This is the picture of the RH "right" cable taken in May 2012.
And here is the "left" RH segment burn which happened in the Dec or Jan weld.