Displaying reports 74521-74540 of 83796.Go to page Start 3723 3724 3725 3726 3727 3728 3729 3730 3731 End
Reports until 17:35, Saturday 25 January 2014
H1 ISC (ISC)
sheila.dwyer@LIGO.ORG - posted 17:35, Saturday 25 January 2014 - last comment - 09:07, Tuesday 28 January 2014(9558)
Comm PLL work today

Sheila, Daniel, Stefan

I tuned up the beat note alignment this morning. 

With the arm locked we have 88uW total on the COMM_A_LF detector, 42uW from the arm and 47uW from the SHG.  This gives us a beatnote of 28mV pp, with the PFD RF power readback saying -35dBm. 

The Comm PLL locks for a few seconds and runs out of range (due to fluctuations at the microseism frequency).  One solution would be to feedback to the ETM  from the green laser at the microseim frequency ( right now we only have very low frequency feedback to HEPI), this would probably be nice in the end, because the PLL would lock nicely and we need to figure out out how to do this for HIFOXY anyway.  Another solution would be to engage COMM with the PLL partially locking, which does still give a useable error signal, which would be quicker to implement.

Comments related to this report
daniel.sigg@LIGO.ORG - 19:36, Saturday 25 January 2014 (9559)

We remembered that we can just use an ezcaservo script to feed the COMM_PLL_CTRLMON signal back to offset of the the mode cleaner VCO,

ezcaservo -s 0 -g -1 -f 0.3 -r H1:ALS-C_COMM_PLL_CTRLMON H1:IMC-VCO_TUNEOFS

We then proceeded to measure the open loop transfer function of the PLL servo. The settings were:

  • Input enable: ON
  • Polarity: OFF
  • Gain: 31 dB
  • Comm filter 1: ON
  • Comm filter 2: ON
  • Boost: OFF
  • Filter: OFF
  • VCO Compensation: ON
  • Low pass; ON
  • Daughter board: OFF
  • Internal VCO path: OFF

The unity gain frequency is at 55 kHz with a phase margin of 40º.

Images attached to this comment
Non-image files attached to this comment
alexan.staley@LIGO.ORG - 09:07, Tuesday 28 January 2014 (9597)

With the same configurations as above I measured the power spectrum out of the PFD IMON while the PLL was locked.

Non-image files attached to this comment
H1 ISC (ISC)
koji.arai@LIGO.ORG - posted 14:06, Saturday 25 January 2014 - last comment - 19:49, Saturday 25 January 2014(9550)
Dipelxers for REFL 3f and AS 2f installed

[Koji Yuta]

On Friday afternoon, an RF amplifier unit with 3f (27/135MHz) diplexer (D1300989) and a 4ch demodulator unit
with 2f (18/90MHz) diplexer mod (E1300899) were installed to R2U27 and R3U8, respectively.

- The RF diplexer amplifier D1300989 S1400079

The module was fixed at U27 of the R2 rack and cabled up. Test signals were applied from an RF signal source via the installed TNC-N cable.
Quick check of the 3f chain has been done:
1) Applied a -40dBm  (6.3mVpp) signal at ~27.5MHz to the input cable => obtained the output of 2.5Hz with the amplitude of ~1200Vpp (attachment 1)
2) Applied a -50dBm  (2.0mVpp) signal at ~136.5MHz to the input cable => obtained the output of 270Hz with the amplitude of ~11500Vpp (attachment 2)

There could have been the whitening filters turned on. So the response should be done again with more careful tuning of the input frequency.

- The RF diplexer amplifier D1300899

The demodulator was modified by Dick and tested by Yuta. The test proceduer is here. E1400033

The module is installed to the R3U8 for AS18 and AS90. There are LO signals labeled Ch1/2/3.
However, the diplexer channels for 9/18MHz are CH3 and CH4. So we need to confirm what the
correct channel assignment should be. This will affect the ADC channel assignment.

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 19:49, Saturday 25 January 2014 (9560)

The V1 version in the dcc represents the as-built.

H1 SEI (INS, SEI)
jim.warner@LIGO.ORG - posted 12:41, Saturday 25 January 2014 (9557)
HAM4 TF's don't look good

Transfer functions on HAM4 didn't go as well as hoped. There are some issues starting around .5 hz, that are only visible on the GS13s, then more around 3hz, still mostly visible only on GS13s. I don't know what to make of it, as the CPS's don't seem off in the same areas (see attached pdf's). I tried taking several DTT tf's over the same region (0.1 - 5hz in the attached png image), and they don't look as bad the matlab tf's. Everything else on the ISI looks good.

Images attached to this report
Non-image files attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 12:28, Saturday 25 January 2014 (9556)
Mucked around in Blend Filter Space on ITMx ~0930 -- 1200pst

Tried a few things such as 250mHz blends on Stage1 & 2 for all dofs, w & w/o notches, tried notch on T240 (not helpful.)

Noise of Stage2 CPSX & GS13X blend In1 was higher generally between .5 & 1 hz with the 250 vs 750 blend, that seemed strange.

.5hz peak appears on St1 CPSX when switched to T100.44Notch on Stg1X from 750mHz, that too seemed strange to me.

Left ITMx in same configuration I found it this morning: 750mHz blends everywhere except St1 Y has T100mHz_NO.44 and Stage2 X & Y has Narrow_Notch added.

No alignment changes.

H1 ISC (CDS)
sheila.dwyer@LIGO.ORG - posted 11:49, Saturday 25 January 2014 (9555)
bad cables for PLL boards

The cables H1: ISC 414 and 416 have a problem with either pin 3 or 16 or both.  These are the pins used for the input offset adjust for the PLL boards.  I used the tester at the etherCAT chassis and saw the offset adjust fine, then used the tester at the rack end of the cable and I don't see it.  This is D19 on the schematic D1300812

Other things are working, like the gains and the OK status. 

H1 General
sheila.dwyer@LIGO.ORG - posted 10:05, Saturday 25 January 2014 (9554)
Going to ISCT1
H1 ISC
stefan.ballmer@LIGO.ORG - posted 01:16, Saturday 25 January 2014 (9553)
Some filter fitting
Kiwamu, Stefan

- Fitted the  BS M2 L2P drivealign - we get about the same performance for isolation
- Tried to fit the BS M2 L2Y drivealign - the result was worse than the previous filter, so I just left the old filter in.
- Kiwamu fitted the PRM M2 L2P drivealign - we get a decent decoupling - more than 3 around the peak at 0.75ish Hz

- Started the PRM M2 P2Y measurement.
H1 SEI
sebastien.biscans@LIGO.ORG - posted 18:14, Friday 24 January 2014 (9551)
BSC-ITMX 0.5Hz investigation

We've been seing a 0.5Hz resonance (plus harmonics) on BSC-ITMX (this Jeff's summary here). We investigated more on that today.

This half hertz:

- appears on ALL the sensors of the ISI on X,Y and RZ

- appears on ALL the sensors of the ISI on H1,H2 and H3 (which makes sense according to the previous statement)

- doesn't appear on HEPI

- appears on M0 Longitudinal, but with a much smaller amplitude

 

We've tried different configurations. We first noticed this issue with HEPI position controlled and ISI fully controlled (Ctrl lvl1 on ST1+ST2, T100mHz blend filters on ST1-X and ST1-Y, 750mHz blend elsewhere).

- It disappears when the ISI is under damping only.

- It reappears when only ST1 is controlled.

Weird thing: it doesn't appear when only ST1-X controller is ON, but it DOES appear when only ST1-Y controller is ON.

Also, to be sure that the issue wasn't coming from the actuators, I drove a white noise on ST1-X and ST1-Y (damping only). It didn't appear.

 

At this point, I would guess we're having a CPS/ground issue again, with no conviction. We'll try to monk with the electronics Monday.

To finish, I just want to remind that we have a temporary solution, which is putting a narrow notch at this frequency into ST2-CPS blend filters. With this temporary fix, we are pretty happy about the ISI performance.

Images attached to this report
H1 SEI (ISC, SUS)
jeffrey.kissel@LIGO.ORG - posted 16:56, Friday 24 January 2014 (9546)
Testing Configurations of Corner Station BSC-ISIs vs Oscillations
S. Biscans, H. Radkins, J. Warner, J. Kissel

[[Belated entry from last night]]

In order to investigate the recently found oscillations and/or frequency combs in ISI ITMX that has been troubling the Green Team (see LHO aLOG 9494), we explored a few different configurations of the corner station BSC-ISIs. This aLOG covers the first three configurations we tested. Since these initial tests, Seb, Jim and Hugh have explored more configurations (see LHO aLOG 9537). This serves as the record for the temporary temporary solution which got the performance needed to satisfy the Green Team (see LHO aLOG 9518) -- the addition of a high-Q notch in the ISI-ITMX displacement sensor blend filters on both both stages.

With the 0.5 [Hz] notch on both stages, we're able to reduce the RMS optic pitch motion from 160 [nrad] to 80 [nrad].

Attachment 1: performance of ST2, as measured by the ST2 GS13s (stage 2 inertial censors) in three different configurations:
(1) Initial measurement in the current best configuration,  Level 1 isolation filters, with "T100mHz_N0.44" blends on ST1 XY and "750mHz" on ST1 ZRXRYRX and all of ST2.
(2) Exact same configuration of ISI-ITMX, but with the ISI-ITMY CPS turned off at the racks in the high-back (via the independent rocker switches on the back panel).
(3) With ISI-ITMY's CPS still off, similar control loop and blend filter configuration of ISI-ITMX except with a 0.5 [Hz] notch filter  in the X and Y degrees of freedom of both stages.

Attachment 2: A comparison between blend filters used in the current best configuration, with and without the 0.5 [Hz] notch filter. Note that this an export from the filters *actually installed* in foton, so the blend filters include the sensor response inversion, so they're not just the complementary blend shape (which is why the 750 mHz filters look screwy upon first glance). 

Remember, this notch is a temporary temporary solution. We're continuing to investigate the source of the problem, and we look forward to both the temporary (see LLO aLOG 10584) and permanent hardware / analog electronics solution (still under development) to the CPS oscillators beating against each other. However, while it's obvious the beating oscillators cured *some* of the frequency comb (comparing Initial Measurement against ISI-ITMY CPS OFF) we're not convinced the beating oscillators is the source of the exactly-0.5[Hz]-line.

For the record, 
- The foton design is notch(0.5,20,20) for a frequency of 0.5 [Hz] a Q of 20 and a depth of 20 dB. It also has a ramp time of 10 sec on the output.
- The notch lives in a separate filter module (FM5, called "notch_narrow") in the CPS blend filter banks (e.g. ITMX_ST1_BLND_X_CPS_CUR)
- You cannot access/turn ON/OFF from the main blend filter screen -- you have to open the "CURR" CPS sub-screen
Non-image files attached to this report
H1 PSL (PSL)
sheila.dwyer@LIGO.ORG - posted 16:25, Friday 24 January 2014 (9549)
PSL restarted

The PSL shut down because the chiller had a flow sensor 1 error.  Reseting the status then restarting the chiller cleared the error.  The PSL is back on now. 

H1 SUS
betsy.weaver@LIGO.ORG - posted 16:21, Friday 24 January 2014 - last comment - 11:44, Wednesday 10 December 2014(9548)
ETMy QUAD back on the ISI

Travis/Betsy

This morning, we staged to put the ETMy QUAD monolithic structure back together.  We vacuumed as much of the structures as we could.  I re-first-contact-cleaned the ERM-front surface since it had been exposed to the elements since the last vent and showed much particulate dispite blowing it with N2.  The FC cleaning worked and the surface looked improved.  We then removed the ETMy test mass HR First contact (which has been on since it left CIT) and attached the 2 lower structures.  Using the Genie, w transfered the completed lower structure to the silver pallet jack + 5-axis lift table.  We then maneuvered the LS into place and attached it to the upper structure already on the ISI table.  We removed all of the lifting EQ from the QUAD and stowed everything in the unused welding cleanroom.  All went well.  We did not suspend the QUAD - we'll start that on Monday.

Images attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 11:44, Wednesday 10 December 2014 (15533)

In the above alog I state that we removed the ETMy-HR First Contact sheet in order to mate the chains togther.  This MUST be a typo as we always remove the TM-AR FirstContact (not the HR) when we mate the chains together.

H1 General
jeffrey.bartlett@LIGO.ORG - posted 15:58, Friday 24 January 2014 (9547)
Ops Summary
Apollo – In LVEA working on nitrogen piping.

Jim B. - 2 DAC restarts
Apollo & Justin – On top of HAM2 installing the parking beam beam dump
Betsy & Travis - At End-Y working on monolithic 
Corey & Filiberto – At End-Y working on TMS cable problem
Doug – Moving survey equipment into LVEA
Justin - Transition LVEA to Laser Safe
Soil & Ground Water on site checking wells
Betsy & Travis At End-Y working on monolithic
Corey – At End-X TMS lab looking for parts
Jeff K. - Running long TFs on PRM – needs Mode Cleaner
PSL laser down 
H1 SEI (INS, SEI)
jim.warner@LIGO.ORG - posted 14:23, Friday 24 January 2014 (9545)
TF running on HAM4 ISI

Opsws0. Should complete sometime early Saturday.

H1 ISC (ISC)
corey.gray@LIGO.ORG - posted 13:53, Friday 24 January 2014 (9544)
Cable Removed From EY TMS (On Test Stand)

(Corey, Filiberto)

Went out during an open window for access at the Test Stand to perform an in-situ Hi-Pot cable test of our Seismically-Responsible TMS Beam Diverter Cable (D1000223 s/n S1104078); it was observed to have an electrical short in it.  Unfortunately, the Hi-Pot tester was not able to run a measurement on the cable with it clamped on the ISI. 

I removed the cable off the ISI and then Filiberto ran a Hi-Pot test, and it was confirmed that Pin#1 (Shield) is shorted to Pin#23

We will either fix this cable or replace it with a D1000225 (different guage wire cable).

H1 ISC
alexan.staley@LIGO.ORG - posted 13:41, Friday 24 January 2014 (9515)
Angular Displacement

(Alexa, Sheila)

We wanted to compare our senstitivty to angular motion between HIFOX and Y. I used Seigman (Lasers, Chap 19) equation for the beam displacement from the optical axis as a function of mirror displacements. In my calculation, I used the following values

I found the ratio of HIFO X to HIFOY for...

Non-image files attached to this report
H1 General
jeffrey.bartlett@LIGO.ORG - posted 12:06, Friday 24 January 2014 (9542)
HAM2 Work
11:50 - Bubba & Justin install parking beam beam dump cover on top of HAM2. Done 12:00 
H1 ISC
alexan.staley@LIGO.ORG - posted 08:35, Friday 24 January 2014 - last comment - 13:49, Friday 24 January 2014(9532)
GPIB at EX

GPIB01-wifi IP: 10.22.10.20/20

GPIB01 IP: 10.22.10.30/20

...are at EX hooked up to the SR785

Comments related to this report
alexan.staley@LIGO.ORG - 13:49, Friday 24 January 2014 (9543)

The python file to run the SR785 from the control room is under: /ligo/home/alexan.staley/Public/EX_SR785/TFSR786.py

Currently the SR785 is set up for the PDH servo board. In order to take other TFs the script is still valid, but one must manually change the cables.

H1 ISC (SEI, SUS)
sheila.dwyer@LIGO.ORG - posted 17:40, Thursday 23 January 2014 - last comment - 18:09, Friday 24 January 2014(9518)
stable arm cavity!

Green team-

The arm cavity is finally locking stably, thanks to the work of Sebastian, Hugh, Jeff and company to reduce our pitch fluctuations.  Now we have about 5% fluctuations in the transmitted power that comes from pitch fluctuations, much better than the 50% we had this morning, and the cavity has been locked at least for 10s of minutes.  The slow feedback is now on, controlled by the autolocker. 

We get a max transmission of about 740 counts on ALS-C_COMM_LF, while the single shot beam stayed at 45 counts, which means that the on resonance/single shot resonance is 16.1, so we are getting 74% of the power that we would expect and probably have 26% of our power in higher order modes ( improved from 45% this morning).  This may have been due to Alexa and I moving the EOM in our effort to reduce the RF AM.  Maybe it is worth tweaking the EOM alingment when the cavity is locked to see if this is the sourcce of our mode mismatch. 

I will leave the cavity locking with the autolocker on, until the red team wants to misaling it. 

Comments related to this report
sheila.dwyer@LIGO.ORG - 18:09, Friday 24 January 2014 (9552)

The X arm cavity stayed locked with green only for over 6 hours last night. Attached is a histogram of H1:ALS-C_COMM_LF_OUTPUT calibrated in uW arriving on ISCT1. 

Images attached to this comment
Displaying reports 74521-74540 of 83796.Go to page Start 3723 3724 3725 3726 3727 3728 3729 3730 3731 End