Displaying reports 74721-74740 of 83756.Go to page Start 3733 3734 3735 3736 3737 3738 3739 3740 3741 End
Reports until 08:25, Thursday 16 January 2014
H1 SEI
hugh.radkins@LIGO.ORG - posted 08:25, Thursday 16 January 2014 (9317)
HEPI Position loops installed on ETMX--T240 quieting revisited

Well I got fooled here and at the moment I don't have the data to say anything.  Referring to alog 2973, I said the loop closing on the HEPI position quieted the noise from the IPS that appeared to be getting to the T240s on the ISI stage1.  However, Friday night when Jim, Fabrice and I were closing these loops, Jim reduced the gain on the T240s; I failed to confirm they were put back to their nominal high position.  So the trend I posted indicating the great reduction in noise was only the reduction of the T240 gain.  Yesterday afternoon I put the gain back to where it should be.

The attached 10 day plot shows the new story.  The last part of the plot shows the period after the gain increase.  It is smaller than the noisy period before last Fridays position loop turn on; but, remember Keita reduced the pitch request of HEPI and just by the scaling it may be completely due to this.

All is not doom & gloom though.  All through the night, there were no T240 glitches and no watchdogs trips on either ISI or HEPI.  Of course this could be completely attributed to the reduced tilting.

Images attached to this report
H1 General
sheila.dwyer@LIGO.ORG - posted 06:04, Thursday 16 January 2014 - last comment - 06:26, Thursday 16 January 2014(9314)
entering LVEA

Heading to ISCt1

Comments related to this report
sheila.dwyer@LIGO.ORG - 06:26, Thursday 16 January 2014 (9316)

done at ISCT1 for now. X arm trans camera realinged, ALS light pipe opened and checked for stray beams from PSL path.

H1 ISC
kiwamu.izumi@LIGO.ORG - posted 23:29, Wednesday 15 January 2014 - last comment - 08:29, Thursday 16 January 2014(9313)
corner locking activity:

Stefan, Kiwamu

We did the following things tonight:

- We measured the BS, PRM and PR2 actuator transfer functions again and convinced ourself that they are not crazy. The BS actuator was found to have the opposite sign and 10 times bigger gain at 20 Hz.

- As a preparation for PRMI locking, we started using RELAIR_A_RF45. We found that it is 5 times smaller than RF9 in terms of the PRX optical gain. We could easily close the PRX/Y loop with RF45_I.

- Because we were not sure if we could close the MICH loop with BS, we went back to PRY to verify the behavior of the BS actuator in action. The idea is to optimize the LSC filters for MICH loop beforehand using PRY.

-We discovered that there was a length to pitch coupling in BS which caused 5-10 urad excursion in its angle. This was big enough to unlock the PRY loop.

- POPAIR_B_RF18 demod phase = 80 deg

Our message is that we need to put some more efforts on the BS actuator.

Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 08:29, Thursday 16 January 2014 (9319)

A comment on the attached plot:

They are the transfer functions from the suspension input to REFLAIR_RF9. The vertical axis is not calibrated to any meaningful units. The BS transfer function is artificially sign-flipped to see how much the phase gets delayed. Also we took a ratio of BS/PRM to figure out what kind of extra filters we need to close a loop with BS. You can see that the PRM and BS actuator responses are different and therefore we are working on BS.

H1 SUS
betsy.weaver@LIGO.ORG - posted 20:54, Wednesday 15 January 2014 - last comment - 09:16, Thursday 16 January 2014(9312)
ETMy PUM prism shield notes

We used the new prism protection shield on the PUM prisms during the welding of the ETMy monolithic in Dec and again this last week.  We used the shield during the welding steps but not always during the lower power annealing steps, as was assumed by the users.  We think the shield caused more stray beams from the welding laser than when we weld without it.  We found more stray beam damage to curtains and garb than in any previous welding session, all of which we tried to mitigate.  Possibly we could consider making the shield out of a different material than copper.

We also found that one of the prism glue joints suffered some heating, and subsequent charring, at the exterior of the prism when the shield was not in place during annealing.  This occurred on only 1 prism.  The other prism had the shield in place for all of the welding (as is standard) and for the annealing in Jan which is why we didn't see the charring.  (We did not observe any stress fractures in the glass as was seem in the ETMx PUM!)  So, the new shield has the following:

PRO
Prism joint is better isolated from heating/burning during welding.

CON
Shield causes more CO2 beam reflections which are difficult to manage.

Below are some pictures of the shield and the prism charring when the shield was not in place.  Note, we had to cut a half circle view hole on each side of the prism for better visibility of the horn welding.  Also, as shown in the pictures, it was difficult to get the shield positioned against the optic.

Images attached to this report
Comments related to this report
garilynn.billingsley@LIGO.ORG - 09:16, Thursday 16 January 2014 (9322)
The good news is that our testing with the heat gun gave us great confidence in the stability of this epoxy even at high temperatures.  My log book indicates that prisms started de-bonding at ~330 degrees C.  And then only with shear force.  The color of the heated glue was amber (see report at
https://dcc.ligo.org/LIGO-T1300642 )
H1 CDS
david.barker@LIGO.ORG - posted 18:14, Wednesday 15 January 2014 (9311)
digital camera 03 now operational

Dave and Kiwamu

Kiwamu installed a new gigabit ethernet camera (cam03) today but its image was not opening on the workstations. I tracked this down to a typo in the overview MEDM adl file and the image is now viewable.

H1 AOS (ISC, SEI)
hugo.paris@LIGO.ORG - posted 18:00, Wednesday 15 January 2014 - last comment - 11:47, Thursday 16 January 2014(9310)
ISC length control offload path added to HEPI-ETMX

ISC length control offload path was added to HEPI-ETMX's model: h1hpietmx.mdl - See attached screenshot of the model.

The model was re-compiled and re-started - log attached.

DAC restart was required and performed by Dave.

Isolation and alignment offsets were turned back on, per the latest preferred configuration, and the ISC2CART matrix was updated. The outputs of the ISCMON block will be left off until ISC decides to try them.

Note: The signal offloaded to HEPI is the same as the one offloaded to SUS.

The new version of h1hpietmx.mdl was commited under the SVN -r6869

Work was performed under work permit # 4394 which is now closed.

Images attached to this report
Comments related to this report
christopher.wipf@LIGO.ORG - 06:26, Thursday 16 January 2014 (9315)

Using a SUS control signal to drive HEPI will result in aliasing, since the SUS runs at a higher sampling rate than HEPI. This offload path should have its own IPC link, with an anti-aliasing filter installed on the sender.

brian.lantz@LIGO.ORG - 11:47, Thursday 16 January 2014 (9328)ISC, SEI, SUS
also recall that drive in +x for HEPI ETMX will make the arm cavity longer, while the same signal applied to the mirror LONG input will probably make the cavity shorter, so watch the signs.
ISC should pick a place to apply the signs so they get applied in a systematic way.
I suggest that the ISC2CART matrix would make sense, and that a -1 in the LONG-in to X-out would make sense.
H1 DAQ (CDS)
david.barker@LIGO.ORG - posted 17:18, Wednesday 15 January 2014 (9309)
DAQ restart to support h1isietmx change, required mx stream start of some front ends

17:07 I restarted the DAQ to resync it with the new h1isietmx INI file. Unfortunately some other front ends were MX glitched by this and required a /etc/start_streamers.sh MX resync. The front ends which needed this were: h1sush56, h1susauxh56, h1susey, h1pemmx, h1susauxex.

The frame data gap due to the DAQ restart is

Jan 15 17:07 H-H1_R-1073869632-32.gwf

Jan 15 17:10 H-H1_R-1073869792-32.gwf

H1 SEI
hugh.radkins@LIGO.ORG - posted 17:16, Wednesday 15 January 2014 (9308)
ETMX ISI Alignment Targets Modified

We noticed when the HEPI was untilted, some of the ISI target locations were more different than we'd like.  Mainly the Stage1 X (~70um) & RY (5urads) and Stage2 X (5um) & RY (<2urads.)  The others were less than this.  With Keita's OK we reset the ISI targets.  This will translate the tilt of HEPI more completely to the ISI (TMS) and keep the ISI stages parallel.  This may be the better place to operate the ISI rather than having the stages tilted to each other.

The attached snap shows the ISI locations with the untilted HEPI before we updated the Targets.

Images attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:57, Wednesday 15 January 2014 (9307)
ETMx/ITMx ISI State

We have gotten back the ISI performance, at least to a tolerable state for the moment.  Hugo doggedly compared all the filters between the ITMx & the ETMx to get the ETM in the same state.  It ends up being exactly as we had it last Wednesday when Fabrice worked with us.  Stefan has also 'greened'  up the 'State' so that may be helpful.

The state is:  Both ISIs use lvl1 control.  Both ISI Stage1s use 100mHz blends on X Y & RZ (horizontal dofs) and 750mHz on Z RX & RY (verticals.)  Additionally the ITMx has .45Hz notches engaged on X & Y.  For Stage2, the blend is 750mHz for both ISIs.  Both ISIs have been brought to this state with one click "! isolate iTMX lvl1" from the command medm.  It is possible that depending on how long the HEPI at the ETMX has been tilted, the T240 may be too rung up and they may trip the ISI as it attempts to isolate.  We aren't using the T240s in these blends and I'm pretty sure they won't be bothered so the WD trip level can be taken higher temporarily to stop the isolation interruption.

Attached is a plot of the ETM & ITM spectra.  The green ETM spectrum shows the more aggressive things we were attempting and the red trace for the ETM and the dashed trace for the ITM shows the state we are now in and last Wednesday.  We don't isolate as well below .1Hz but between .1 and .4 it is better and that seems most important.

Images attached to this report
H1 PSL (IOO)
kiwamu.izumi@LIGO.ORG - posted 16:54, Wednesday 15 January 2014 (9306)
Rotational stage is installed in PSL, ALS pick off power increased to 250 mW

Kiwamu with remote help from Rodica

I completed two missions as a part of the high power prep:

Some pictures are available in ResourceSpace: https://ligoimages.mit.edu/?c=1434

 

Installation of the rotational stage:

The stage had been ready and sitting on the table for a long time (see alog 8731). First of all, I took the fixed-manual stage out of the main path. Then I removed the wave plate out of it and put it in the motorized stage together with a pair of the white rings which were also the stuff I took out from the manual stage. The motorized stage was then moved to the same place as the old wave plate had been. The position was fine-adjusted such that the beam goes through the center of the wave plate.

Power increment:

I rotated the wave plate which resides between PMC and the EOM to increase the laser power to 10 W. The idea is to give some more power into the ALS doubling path (see alog 9287) while mantaining the incident power of IMC to be 1 W. This means the new rotational stage is the one which decreases the laser power from 10 to 1 W.

In order to set the angle of the rotational stage right, I measured the laser power which would be incident on IMC as a function of the rotational angle. The result is shown below and also the raw data is attached.

According to this measurement, I set the request angle to be 56.1 deg in the medm screen. Plus, to always keep this angle until we are fully ready for 10 W, I physically locked the interlock switch of the rotational stage, so that the power can not change by accident.

Images attached to this report
Non-image files attached to this report
H1 ISC
stefan.ballmer@LIGO.ORG - posted 16:31, Wednesday 15 January 2014 (9299)
asc and iscex model updates
Common parts:
=============
ALS_END.mdl
Added REFL_SLOW and REFL_B_LF routing for arm dither alignment.
SVN revision 6865

H1 only models:
===============
h1iscex.mdl
h1iscey.mdl
Added REFL_SLOW and REFL_B_LF routing for arm dither alignment. This routes the signal through the dewhitening whitening filters.
SVN revision 6866

h1asc.mdl:
Added ADC card 3, channel 17-20 (16-19) to h1asc model.  The last two (channel 19,20) go to green arm transmitted power, X and Y
SVN revision 6863 

H1 General
jeffrey.bartlett@LIGO.ORG - posted 15:57, Wednesday 15 January 2014 (9305)
Ops Summary
Towsen Electric on site for lightning protection inspection
Snow King working on LSB water system
Tumbleweed bailing on X-Arm and at OSB

08:00 Sheila - LVEA working at HAM1/HAM2 area
09:00 Betsy - LVEA hunting for parts
09:27 Kiwamu -Installing rotational stage in H1-PSL enclosure
09:30 John, Richard, & Towsen Electric - LVEA roof lightning protection inspection 
10:20 Richard - H1-PSL enclosure on rotational stage
12:30 Vern & Patrick - CER and at HAM1; power recycle EtherCAT chassis #1 in H1-PSL
13:02 Dave – Working in CER 
13:17 Kiwamu – Installing rotational stage in H1-PSL enclosure
13:40 Filiberto & Frank – Pulling cable at End-X
13:44 Andres – Installing new EQ stops on H1-SR2
15:00 Safety meeting
H1 PSL
kiwamu.izumi@LIGO.ORG - posted 15:47, Wednesday 15 January 2014 (9300)
PMC transmission monitor issue is gone again

Sheila reported an issue with the PMC transmission monitor which had shown a bogus low power readout (see alog 9120).  Since I happened to be in the PSL room this morning, I unplugged and plugged the lemo cable of the PD to see what was going on. For some reason, it fixed after I plugged it back. It now reads the correct power of about 11 W. Also, I could not reproduce the low power state by wiggling or unplugging/plugging the lemo cable. This is exactly the same situation as before (see alog 8622).

H1 General
jeffrey.bartlett@LIGO.ORG - posted 15:05, Wednesday 15 January 2014 (9304)
Andres working on H1-SR2
13:44 Andres installing new EQ stops on H1-SR2 M3 stage
14:20 Work completed
H1 General
jeffrey.bartlett@LIGO.ORG - posted 15:04, Wednesday 15 January 2014 (9303)
Cable Pulling at End-X
13:40 Filiberto & Frank pulling cables at End-X
H1 General
jeffrey.bartlett@LIGO.ORG - posted 15:01, Wednesday 15 January 2014 (9302)
Vern in CER & at HAM1
12:30 Vern and Patrick in CER and around the HAM1 chamber. Power recycle of the chassis #1 E-Cat
13:07 Work completed  
H1 General
jeffrey.bartlett@LIGO.ORG - posted 14:58, Wednesday 15 January 2014 (9301)
Kiwamu in H1-PSL Enclosure
09:27 Kiwamu in H1-PSL enclosure installing rotational stage (WP #4395)
11:49 Out for lunch
13:17 Kiwamu continuing rotational stage work in H1-PSL enclosure
14:30 Finished in H1-PSL enclosure  
H1 SEI
hugh.radkins@LIGO.ORG - posted 12:22, Tuesday 14 January 2014 - last comment - 08:26, Thursday 16 January 2014(9273)
ETMX HEPI position loop closing Quiets T240s

The large tilt requirement into HEPI for the TMS tilting really accentuated the IPS sensor noise when the HEPI loop was open.  The HEPI had not been commissioned so the tilt was direct drive.  On Friday Jim, Fabrice and I closed those loops and I did my best to restore the previous tilt to the system.  We only got to within ~25urads cause the other loop closings caused more drive to the the V1 corner pushing the IPS to 29900counts with a watchdog trigger at 30000.

See the attached 8 day plot.  The plot shows lots of things but mainly look at the lower right graph with T240 INMON.  The first half of the plot is before the hepi position loops were closed.  The quieter interval in the middle left, was during a noise study and we had no tilt (see the various hepi graphs).  In the middle of the time frame we closed the ETMX HEPI position loops and you see the T240 channel go very quiet.  There are no railing spikes that would have tripped the ISI.  On Monday, Keita offloaded much of the HEPI tilt to the TMS because the HEPI IPS was close to its trip level and TMS needed a little bit more tilt.  You can see the HEPI tilt change in the channel 9 & 12 graphs.  However, there is no change in the noise at the T240 when Keita offloaded HEPI to TMS (I zoomed in and there is no difference in the time series view.)

Bottom line, The HEPI tilt will not cause ISI trips with the HEPI position loops closed.  HEPI could take much of the TMS tilt back if needed.

Images attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 08:26, Thursday 16 January 2014 (9318)

See 9317--apparrantly not so uch, ah well.

Displaying reports 74721-74740 of 83756.Go to page Start 3733 3734 3735 3736 3737 3738 3739 3740 3741 End