Displaying reports 7461-7480 of 84615.Go to page Start 370 371 372 373 374 375 376 377 378 End
Reports until 07:36, Tuesday 06 August 2024
LHO General
corey.gray@LIGO.ORG - posted 07:36, Tuesday 06 August 2024 (79465)
Tues DAY Ops Transition: Maintenance Day

TITLE: 08/06 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 3mph Gusts, 1mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.06 μm/s
QUICK SUMMARY:

HAM5 was sealed up last night so work to begin pumpdown will be on the docket as well as Maintenance Day today.  Also have a big tour for DARPA group this morning & the shift started with prrep for that.

LHO VE
janos.csizmazia@LIGO.ORG - posted 18:15, Monday 05 August 2024 (79463)
HAM5 doors installation
Both +X and -X doors have been installed on HAM5.
The inner O-rings at both locations have been replaced, as they were in a substantially bad shape (this was a pre-planned operation).
No other issues have been encountered.
H1 PSL (PSL)
richard.savage@LIGO.ORG - posted 17:19, Monday 05 August 2024 - last comment - 12:23, Wednesday 07 August 2024(79462)
PSL camera image and laser room make-up air fan speeds changed in anticipation of tours in the morning

DaveB, RickS

Dave changed the image on the contrl room PSL screen (Nuc 21) and at the Laser Room to show a larger image of the PSL table.

Laser Room make-up air fan speed set to 100%.  Lights are OFF, but will be switched on in the morning.

 

Comments related to this report
jason.oberling@LIGO.ORG - 12:23, Wednesday 07 August 2024 (79499)

I changed the make-up air speed back to its nominal setting of 20% at ~19:15 UTC (12:15 PDT) on 8/7/2024.  The make-up air being on did cause the Laser Room temperature to drop by a couple degF, which in turn caused the output power of both Amp1 and Amp2 to drop by ~2W each; will monitor over the next several hours to ensure things return to normal as the enclosure returns to its normal thermal equilibrium.

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:31, Monday 05 August 2024 (79461)
OPS Day Shift Summary

TITLE: 08/05 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR:  Nobody
SHIFT SUMMARY:

IFO is in MAINTENANCE for VENTING

Today, the main mission was to put the HAM5 doors back on, and this has been accomplished.

Side Missions:

A reminder that the LHO Vent Plan (a living document so alive it's hyperventilating) can be found in the DCC: LIGO-E2400260

LOG:

Start Time System Name Location Lazer_Haz Task Time End
14:37 FAC Kim, Karen LVEA N Technical Cleaning 15:02
15:29 VAC Travis LVEA N Turbopump Check 15:37
15:48 PCAL Tony LVEA N FOM Display Check 15:51
15:49 VAC Travis LVEA N Purge air check 16:19
17:23 PCAL Richard +2 LVEA, PCAL N Checking on new displays 17:43
17:37 SUS RyanC CR N ETMX OPLEV charge measurement 18:37
19:51 SUS Ryan C EX MR N Resetting VFD Panel 20:45
20:00 FAC Eric LVEA N HAM5 Doors 22:23
20:01 FAC Chris LVEA N HAM5 Doors 22:23
20:01 FAC Tyler LVEA N HAM5 Doors 22:18
20:07 VAC Travis LVEA N HAM5 Doors 21:07
20:23 VAC Gerardo LVEA N HAM5 Doors 22:59
20:44 PEM Genevieve, Sam LVEA N Accelerometer Check 21:29
20:49 VAC Richard LVEA N Gate Valve Air Leakage Check 21:15
21:06 OFI Betsy LVEA & Optics lab N Working on the OFI optics project. 21:12
21:22 SQZ Shiela, Eric, Nergis LVEA N SQZ Table Lookaround 22:01
21:24 FAC Richard LVEA N Y b manifold bangboard check 22:18
21:30 SUS Betsy LVEA N Looking for things 23:29
21:43 TOUR Tony, Sabby + 3 LVEA N Family Tour 22:01
22:28 SQZ Camilla Optics Y SQZ Work 23:28
22:47 OPS Oli, Jenne FCTE N Tour Tour 23:08
22:48 PEM Genevieve, Sam LVEA N Accelerometer Search 23:48
LHO FMCS (PEM)
anthony.sanchez@LIGO.ORG - posted 13:59, Monday 05 August 2024 (79458)
Vibration Sensors HVAC Fans Health

FAMIS: 26317
Using Vibration Sensors To Gauge Health Of HVAC Fans Site Wide
The MX fan1 seems to have some noise that comes and goes in increments of 10- 13 hours.

Both MR fan2 saw and increase in noise starting on the first of August and lasted for about 2 days.
MR2 Fan 6 _170 _1 saw an increase in noise on July 30th. that still persists.

Images attached to this report
H1 SEI (CDS)
ryan.crouch@LIGO.ORG - posted 12:49, Monday 05 August 2024 - last comment - 10:07, Tuesday 06 August 2024(79455)
ETMX glitch?

ETMX's ISI and HEPI both tripped off at 19:41, seemed like a glitch.

Images attached to this report
Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 13:32, Monday 05 August 2024 (79456)

Since this happened, Ryan C went into EX to reset VFD Panel, which allowed HEPI ETMX to stop tripping, but we noticed the T240s railing right after and then switching between extremes - this happened at 13:12 UTC. Screenshot below.

As of 13:31 PT (20:31) UTC, it looks like the T240 counts are coming back down.

Images attached to this comment
ryan.crouch@LIGO.ORG - 13:42, Monday 05 August 2024 (79457)

A look at the sensors during this trip.

Images attached to this comment
jim.warner@LIGO.ORG - 22:20, Monday 05 August 2024 (79464)

Was epics set point for the hepi pump beckhoff set to zero before resetting the vfd? If not, the t240 saturations are probably caused by the changing pressure in the hepi fluid while the pump servo ramps to operating pressure. Normally just resetting the pump vfd without zeroing out the set point would trip the pump, but maybe we got lucky.

david.barker@LIGO.ORG - 08:22, Tuesday 06 August 2024 (79470)

Power glitch Monday 19:41:21 UTC.

Caught by MSR UPS, corner station mains_mon DQ channels for all three phases shown.

Images attached to this comment
ryan.crouch@LIGO.ORG - 10:07, Tuesday 06 August 2024 (79471)

H1:HPI-PUMP_EX_CTRL_LOC_SETPT was set to zero but H1:HPI-PUMP_EX_CTRL_RMT_SETPT was still set to 70. I noticed the pressure came back on its own without me having to use the controller, that setpoint must be why. I'll make sure to zero it first next time.

H1 SUS (SUS)
ryan.crouch@LIGO.ORG - posted 12:10, Monday 05 August 2024 - last comment - 10:26, Tuesday 06 August 2024(79448)
ETMX OPLEV charge measurement

I took the ETMX OPLEV charge measurement, it's been about a week since Rahul updated the L3 HV mon alog79350.

The charge appears to be flatlining now, and even just starting to decrease towards zero on some quads/DOF (UR_Y, LR, LL_P).

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 10:26, Tuesday 06 August 2024 (79472)CDS

The last 2 times I've run the OPLEV charge measurement for ETMX, about an hour later we've had a power glitch that takes down the VFD at the end station, 08/05 alog79455, 07/23 alog79288. Weird coincidence?

LHO VE (VE)
travis.sadecki@LIGO.ORG - posted 11:09, Monday 05 August 2024 (79453)
Corner Station Dew Point Measurement

Dew point measurement taken this morning read at -42.5 oC.  Measurement taken before any activity inside chambers.  Soft covers were on HAM5 and HAM6, HAM7 is isolated.

Images attached to this report
H1 CDS (SEI)
oli.patane@LIGO.ORG - posted 11:08, Monday 05 August 2024 (79454)
Quarterly Inspection of HWWD Trends FAMIS

Closes FAMIS#26508, last checked 77516

All channels had switched in the last quarter(attachment), with there being noticeably less switches in EX and IY since the vent started.

 

Images attached to this report
H1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 11:01, Monday 05 August 2024 (79451)
HAM5 SRM inspected and two EQ stops adjusted

Jeff K, Betsy, Rahul

Making a late entry for SRM rubbing investigation which happened last Thursday (see alog 79425). We went to HAM5 chamber and closely inspected SRM and all the EQ stops for any signs of rubbing. I couldn't see any of them touching/rubbing the chain, also at some places it was hard to see since the suspension is covered in shroud. However, at two places I felt the EQ stops were too close for my comfort, hence I very slightly adjusted them (to create a visible air gap) - first at optic barrel EQ stop and second at the metal upper mass stage. 

Using a dental mirror I also checked the LF and RT bosem flags and found that that LF BOSEM flag is very close to the top LED/PD, with both offsets ON and OFF (was hard too spot any difference) - I am attaching a picture which I took on Jeff's phone. I did not adjust the LF bosem - since we didn't wanted to change the alignment.

Images attached to this report
H1 PSL
oli.patane@LIGO.ORG - posted 10:48, Monday 05 August 2024 (79449)
PSL 10-day Trends

Closes FAMIS#21186, last checked 76673

Cooling (attachment1)
Everything looking good!

Environment (attachment2)
Everything looking good!

Laser (attachment3)
Everything looking good

Stabilization (attachment4)
FSS_TPD_DC has drifted down to ~0.65, which is lower than it''s been in a while, and PMC REFL has continued to rise and is now sometimes surpassing 20.2

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 08:59, Monday 05 August 2024 (79446)
Mon CP1 Fill

Mon Aug 05 08:05:25 2024 INFO: Fill completed in 5min 22secs

Images attached to this report
H1 SUS (ISC)
oli.patane@LIGO.ORG - posted 18:19, Thursday 01 August 2024 - last comment - 10:53, Monday 05 August 2024(79425)
SRM transfer functions - I think we're cleared for doors?

I was running the TFs for SRM to confirm that the suspension is good before we close HAM5, but the transfer function for L was a noticable amount lower in magnitude as compared to the measurements taken on July 17th right before we vented HAM5(pdf). We reran L but this time with the OPTICALIGN offsets turned ON, and the results matched our pre-vent measurements, which seemed strange and prompted looking into whether the RT OSEM has a problem. I've looked back at the state of SRM when the July 17th transfer functions were run, and T, V, R, P, and Y were run in DAMPED and OPTICALIGN offsets were OFF(T&R, V&Y, P). HOWEVER, when the L transfer function was run, SRM was ALIGNED and OPTICALIGN offsets were ON (P: 4254, Y: -9231)(L pre-vent). So that's why today's regular (offset OFF) L didn't match the pre-vent L, and why my second measurement of L with the offset on did match.

Yaw is the only other dof that was affected by the offsets being ON vs OFF, but the pre-vent Y measurements were taken with the offsets OFF, and these match with today's offset OFF measurements so we're all good there.

I'm not sure if there are still concerns about the RT OSEM on SRM M1, now that we know why L matches the pre-vent L, so I'm not sure if these results clear us for closing HAM5 or not.

 

Main set of measurement results (2024-08-01_2000) - SRM DAMPED, OPTICALIGN offset OFF:

$(sussvn)/HSTS/H1/SRM/SAGM1/Results/2024-08-01_2000_H1SUSSRM_M1_ALL_TFs.pdf

 

Second set of measurement results (2024-08-01_2200) - SRM DAMPED, OPTICALIGN offset ON:

$(sussvn)/HSTS/H1/SRM/SAGM1/Results/2024-08-01_2200_H1SUSSRM_M1_ALL_TFs.pdf

 

Full comparison of Pre-Vent, Post-Vent offset OFF (main) set, and Post-Vent offset ON set

$(sussvn)/HSTS/Common/Data/allhstss_2024_July17vAug01_H1SUSSRM_M1_PreVsPostOFIVent_ALL_TFs.pdf

Images attached to this report
Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 11:49, Friday 02 August 2024 (79433)
I agree with Oli that SRM will be "as good as it has been between 2021 and 2024" if we leave it as is, but for different, more expanded reasons covered below.

To expand on Oli's "RT OSEM has a problem" -- the issue is that with the alignment offsets OFF, the RT (right) OSEM sensor / flag has expanded enough that the flag is only barely occulting the LED / PD beam, close to "open light." Thus the drop in magnitude response for Length and Yaw, the only two DOFs that use the RT OSEM. In fact, the M2 UL and M3 UL OSEMs, i.e. the lower stage left OSEMs are further *engaged*, close to "closed light." This is consistent with an overall positive yaw (+RZ) of the suspension w.r.t. the cage.

The *current* SRM alignment offsets are 
    (P: 1663, Y: -3095 [urad]) 2024-08-01, post OFI recovery and aux laser alignment, in air, HEPI locked 

This digital request of *negative* ~3 millirads of yaw *centers* the OSEMs, implying that the OSEMs have been centered to the *alignment offsets ON* position. With the OSEMs centered, the magnitude of the response increases and looks cleaner because both LF and RT are contributing to measurement of the L and Y DOFs.

This checks out with the last time that we moved the OSEMs w.r.t. to the flags -- in 2021 -- see LHO:60576 where our goal was to keep the physical alignment of the optic the same, even though moving the OSEMs changes the digital request to get there. In that case, we kept the physical alignment and centered the top mass OSEMs to the alignment offsets ON, preserved physical alignment.

Importantly -- the result of the 2021 adventure of reproducing in-vac alignment while the IFO was in air was to leave the alignment offsets at
    (P: 1738.28, Y: -3296 [urad]) 2021-11-08 (LHO:60578)
which is within 200 [urad] of the current slider values, and where the OSEMs are reasonably centered and responding well now.

These are also consistent with pre-vent in 2024 with OFI KTP damage in place, where with HAM5/6 HEPIs locked, a single-bounce IFO beam was used to find a good alignment
    (P: 2192, Y: -3166 [urad]) 2024-07-17 (LHO:79246)

The offsets that Ibrahim used only on the L DOF during the July 17th health check, as Oli quotes, are:
    (P: 4254, Y: -9231 [urad]) 2024-07-17 (LHO:79202)
which I believe were some very-lost, very-brief, temporary "I didn't realize HEPI was locked" alignment state used just prior to the official single bounce restoration later that day, LHO:79246, so the values of these should be ignored.

Finally, I attach a trend of the SRM alignment offsets over the last 4 months of sordid history with the OFI's KTP damage, covering both in-air and in-vac, HEPI unlocked and unlocked.
This also confirms that SRM's alignment, in all of these scenarios, is never needed to be outside of the 
    (P: 1600-2400 [urad], Y: 3000-3500 [urad])
range, i.e. less than 1 [mrad] from the 2021 positions (and the I suspect the large low pitch request after venting is the need to account for bouyancy of the optic, so really the alignment should stay within 0.5 pmrad] = 500 [urad] of those 2021 values.)

Note that this requested alignment range consumes a little less than half of the DAC range at ~50000 [ct] for the pitch OSEMs (T2 and T3) and yaw OSEMs (LF and RT).

Thus, if we just leave SRM alone, I suspect we'll be just as happy the SRM alignment and OSEM performance as we were between Nov 2021 until Jul 2024. This was the same decision we made in 2021. We'll just have to somehow remember that, for SRM, in order to get centered OSEMs to provide a OK performance on the top-mass "health check" transfer functions, we need the alignment offsets ON and in within 500 [urad] of (P: 2200, Y: -3300 [urad]). We can test where the boundaries of the alignment slider requests vs. RT OSEM performance decay during pump-down.

That being said, if we really want to mechanically relieve the yaw offset and restore centering of M1 RT (and M2 & M3 UL) we can...
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 10:53, Monday 05 August 2024 (79450)FRS
Opened IIET Ticket 31769, to record that we've thought carefully about this decision to "let the 2021 OSEM position and SRM mechanical alignment ride," but that we reserve the right to try to mechanically offload *next* time.

Hopefully the ticket and this aLOG series provides enough breadcrumbs to remember that we should relieve the alignment when we have the AUX laser set up already. 
H1 CDS (SUS)
filiberto.clara@LIGO.ORG - posted 14:00, Thursday 01 August 2024 - last comment - 09:39, Monday 05 August 2024(79417)
Ground Loop Checks - HAM5 & HAM6

SUS HAM 5-6 System Wiring Diagrams D1002740
Grounding and Shielding at LIGO T1200131

Things to note:

1. HAM6 ISC cabling was not checked for ground loops
2. Short found on the OFI (cable SUS_SQ_30). Pin 13 shorting to ground. In-chamber ground NOT resolved.
3. All cables listed below passed testing:

SUS_HAM5_001 (SR3 Top)
SUS_HAM5_002 (SRM/SR3 Shared)
SUS_HAM5_019 (SR3 Middle)
SUS_HAM5_020 (SR3 Bottom)
SUS_HAM5_003 (SRM Top)
SUS_HAM5_025 (SRM Middle)
SUS_HAM5_026 (SRM Bottom)
SUS_ZM6_21 (ZM6)
SUS_HAM6_10 (OMC Top/Left)
SUS_HAM6_11 (OMC Right/Side)
ISC_236 (OM1)
ISC_237 (OM2)
ISC_238 (OM3)

Comments related to this report
betsy.weaver@LIGO.ORG - 09:39, Monday 05 August 2024 (79447)

In HAM5, Mitchell and I could not find the source of the shield grounding issue on the OFI AOSEM cable chain.  We did the usual tricks:

1) Disconnected 25pin at the feedthru to see if the connector screws were touching the flange (no they didn't seem to be)

2) Made sre the 4th unused quadrapus cable end was not stowed anywhere that caused grounding to the shield

3) Fussed with/lifted/recoiled all of the coils in many places, no change to grounding.

In the past, when none of the above fix the issue, the entire cable length gets swapped out.  However in consult with Kissel and commissioners, we did not feel these AOSEM control warranted needing to do this given that we are mid O4b.  Opening a ticket to deal with this later.

H1 SYS
sheila.dwyer@LIGO.ORG - posted 08:47, Thursday 01 August 2024 - last comment - 13:28, Wednesday 16 October 2024(79397)
fast shutter slow motion video

A slow motion video of the fast shutter, firing with the high voltage driver in air, is here:  slow motion video

Comments related to this report
keita.kawabe@LIGO.ORG - 16:33, Monday 05 August 2024 (79460)

Sheila's original video is ~2sec footage of fast shutter, supposedly at 150 fps according to the file metadata.

Attached is an edited video that shows the 50ms of FS action slowed down by a factor of 10. "SRC TC" is the time elapsed since the start of (Sheila's original) video multiplied by a factor of 10, i.e. 1 sec in SRC TC is actually 100ms. This timestamp is not to be trusted at the lowest digit of sub-second (ms level in reality) because there's some frame interpolation going on due to mismatch between the standard output frame rate of 24FPS VS the source frame rate (150 slowed down to 15 FPS). Anyway, the mirror goes down lower than the closed position right after the initial thrust of the HV fast shutter motion, and even a few bounces after that, before the shutter eventually settles to the permanently closed position.

Also attached is an annotated png file of four frames ("Open", "HV thrust", "Bounce to the bottom" and "Close").

Images attached to this comment
Non-image files attached to this comment
keita.kawabe@LIGO.ORG - 13:28, Wednesday 16 October 2024 (80716)

In light of recent failure of the replacement FS at LLO where the mirror broke off due to the hard stops that were set too low, and a comment by Rich (LLO alog 73584) I watched the video of the LHO unit again (see my entry above).

Though LHO video was shot from the side where we cannot see the position of the hard stop, the bobbin might be hitting the stops right after the launch even though the height of the stops looks good to my eyes. See TC~00:00:05:06. And the bobbing oscillates several times though it never hits the stops again.

Does this mean that the magnetic braking is too weak?

LHO VE (ISC, VE)
gerardo.moreno@LIGO.ORG - posted 15:01, Monday 29 July 2024 - last comment - 18:50, Tuesday 06 August 2024(79352)
GV5 Went From Soft Close to Hard Close Over The Weekend

Noticed that GV5 had hard closed on Saturday at 19:59 utc time, no human intervention.  It appears as if the instrument air pressure left for soft close GV5 was enough to hard close it.  According to PEM instruments near GV5 made lots of noise, see attached plot, accelerometer and microphone data.

I checked the dial on the gauge to measure the instrument air at GV5, and indeed there was only about 10 psi, this value is within the "usual" pressure used for soft clossing pneumatic gate valves and per procedure.

No interaction is required at this moment from the vacuum team.

Tagging ISC, since sensitive equipment is hanging near this gate valve, like cameras and OpLevs.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 11:15, Tuesday 30 July 2024 (79364)

I converted this microphone DQ signal to an audio wav file. The microphone saturates at +/-32768 for a fraction of a second, but you can hear the echo fade away after this.

Non-image files attached to this comment
david.barker@LIGO.ORG - 13:53, Tuesday 30 July 2024 (79365)

Here is the accelerometer as a wav audio:

(new file added at 13:52, orig file was created using the incorrect frequency of 16kHz, this is actually a 8kHz channel)

Non-image files attached to this comment
camilla.compton@LIGO.ORG - 15:24, Monday 05 August 2024 (79459)ISC

The ITMY Oplev (aligned at the time) didn't see this hard close, plot attached. 

Images attached to this comment
gerardo.moreno@LIGO.ORG - 18:50, Tuesday 06 August 2024 (79481)VE

Remember GV1 is closed, this makes ITMY Oplev blind, Sum on trend above is very small.

H1 SUS (CAL, DetChar, ISC, Lockloss, OpsInfo, SQZ, SUS)
jeffrey.kissel@LIGO.ORG - posted 15:48, Monday 08 November 2021 - last comment - 10:54, Monday 05 August 2024(60576)
All H1SUSSRM, and H1SUSSR3 M1 SD OSEMs Recentered
J. Kissel, B. Weaver

Picking up from the recommendations from LHO aLOG 60494 and LHO aLOG 60498 regarding what to do with the HXTSs H1 SUS SRM and H1 SUS SR3 OSEMs "issues" respectively, Betsy and I followed the recommendations for both SUS today, and centered all OSEM values such that they're at mid-range when the SUS are at the position they are when in-vacuum, during nominal low noise.

For SR3, this was *very easy*, and just involved re-centering the M1 SD OSEM. Since SD is not involved in any alignment control, we merely need the flag position to sit in the middle of the calibrated range. So, Besty backed out the OSEM from its previous position at -76 [um], to ~0 [um].

For SRM, this was more of a process, but the process outlined in LHO:60494 actually worked really well.

To the end user, though it may *appear* as though alignment of H1 SUS SRM has changed, if one solely looks at the DC position of OSEM sensors to reflect mechanical alignment, but this is not the case. Today's exercise proves (albeit crudely and imprecisely) that the actuation strength of the coil-magnet systems of the BOSEMs is roughly constant across/within the range the of the LED / PD shadow sensor system, and assuming such we successfully centered the OSEM sensors around the position of the flags when the coil magnet systems are steering the SUS into the place that the IFO is happy during nominal low-noise.

I attach detailed notes of all the steps along the way, and I'll add a comment to this log that has the "in vacuum, during nominal low noise" trends that I used to inform where we want the SUS to be. The trends were taken from a ~24 hour stretch in May 2021, *after* we swapped ITMY and the IFO was aligned around a "point absorber free" ITMY.
Note, because there is signficant low frequency DAC request from the global length and alignment loops when in nominal low noise, I recreated that additional requested DC position adjustment (beyond just the slider values) from global control by adding OFFSETs in 

Also of interest during this process was gathering the second ever open light current values for the M1 BOSEMs. As mentioned in LHO:60494, I dug up the first and only measurements from 2014 in LHO:60477, and we now have a definite measure of the decay of these 6 BOSEMS over 7.5 years. In short, there is ~20% decay in open light current. But, that doesn't mean I want to replace them -- my gut tells me "we still have time."
Full data listed in the table below, with the new open light current (OLC) value in bold.
              OLC 2014    OLC 2014      OLC 2021   OLC 2021     2014-2021    2014-2021    (2014-2021)/2014     
              [ADC ct]    [PD uA]       [ADC ct]   [PD uA]      [ADC ct]     [uA]         [%]
SRM M1 T1     26908       68.431        20585       52.35         6323       16.08        23.499
SRM M1 T2     25472       64.779        18996       48.309        6476       16.469       25.424
SRM M1 T3     28670       72.912        22119       56.252        6551       16.66        22.85
SRM M1 LF     27764       70.608        20831       52.976        6933       17.632       24.971
SRM M1 RT     26272       66.813        21110       53.686        5162       13.128       19.648
SRM M1 SD     25516       64.891        18715       47.595        6801       17.296       26.654

Note: even though we *measured* new open light current values, we did *not* update the compensating offset or gain.
I'll need to think a bit more about that that means in terms of systematic error in the OSEM displacement calibration.
Images attached to this report
Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 16:01, Monday 08 November 2021 (60578)
Here're a bunch of trends that I used to inform how much DAC / coil / magnet drive I should be putting on M1 in order to achieve an alignment of H1 SUS SRM that replicates the most recent good in-vacuum, nominal low noise alignment. 

The time I used was around the time of May 09 2021 20:30 UTC.
Though the alignment swims around slowly on the ~12 hour timescale during the lock stretch, it's not that much, so I used the following DAC request to recreate the roughly equivalent alignment:
                                      [urad]              [DAC ct]       
H1:SUS-SRM_M1_OPTICALIGN_P_OFFSET     1738.28   OUTPUT    3259.45
H1:SUS-SRM_M1_OPTICALIGN_Y_OFFSET    -3296.41   OUTPUT    -8836.36
  
                                 [DAC ct]
H1:SUS-SRM_M1_LOCK_L_OUTPUT      -5000
H1:SUS-SRM_M1_LOCK_P_OUTPUT         10
H1:SUS-SRM_M1_LOCK_Y_OUTPUT       -120

H1:SUS-SRM_M1_COILOUTF_T1_INMON      0
H1:SUS-SRM_M1_COILOUTF_T2_INMON  54769
H1:SUS-SRM_M1_COILOUTF_T3_INMON -54769
H1:SUS-SRM_M1_COILOUTF_LF_INMON  53488
H1:SUS-SRM_M1_COILOUTF_RT_INMON -58488
H1:SUS-SRM_M1_COILOUTF_SD_INMON      0
(where, in case it's not clear, the LF RT OSEMs drive Longitudinal and Yaw, and the T2 T3 OSEMs drive Pitch.)
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 16:09, Monday 08 November 2021 (60580)
Just because I'm insatiably curious... ("were the OSEMs actually 'open lighted'?" so we're not confused between "actual LED decay" and just "a little bit of flag is still occluding the LED light") I also attach here a trend of the H1 SUS SRM M1 BOSEMs while Betsy has used the PEEK CAM nuts to have them longitudinally "backed off" from their flags.

It's ... too interesting if I look too closely (at the "10s of counts" level), so I'm going to ignore this, and justify it with the same argument I gave recently to a different SUS team in LHO aLOG 60179: 
"you need not worry about a 50 / 30000 = 0.001 or 0.1% error in the calibration gain of 30000/OLC.

Conclusion -- 10s of counts error (or uncertainty due to environmental conditions) don't matter."
See that aLOG for full discussion.
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 16:29, Monday 29 November 2021 (60785)
Just prior to this recentering, I took a health check of the SUS in air with the ISI locked, using data from templates marked with the time stamp 2021-11-08_2000. Attached are the post-processed results. Nothing alarming here, just posting for comparison of data we *after* this change to the top mass OSEMS. (Well, not *change*, but re-centering as best we could around the in-observation alignment.) 

Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 10:54, Monday 05 August 2024 (79452)FRS
Cross-referencing IIET Ticket 31769, which reminds us to revisit the mechanical alignment of SRM in 2025-2026, because in 2024, we decided to "let it ride," where "it" is the mechanical alignment kept, and OSEM positions we set, in this aLOG.
Displaying reports 7461-7480 of 84615.Go to page Start 370 371 372 373 374 375 376 377 378 End