Reports until 16:34, Friday 06 December 2013
H1 SUS
arnaud.pele@LIGO.ORG - posted 16:34, Friday 06 December 2013 (8870)
Mode cleaner snapshots and updated states for ODC bits

New safe snapshots have been saved for MC1 MC2 MC3 with updated "correct state" for the lock bank (cf screenshot 2), updated bit masks (Bitmasks 8 and 9 were turned off) (cf screenshot 1), and updated alignment offsets during the lock. The ODC status has now its bit 1 to 7 turning green when necessary.

Bitmasks 8 and 9 were turned off using caput from the command line :

caput H1:SUS-MC3_ODC_CHANNEL_BITMASK 254

Images attached to this report
X1 DTS
james.batch@LIGO.ORG - posted 16:06, Friday 06 December 2013 (8869)
System admin work on x1work, imac workstations
For x1work, installed nfs server and exported /usr1 for mounting as /ligo.

For x1ws0 (iMac), mounted x1work:/usr1 as /ligo to allow native OS X software to run on workstation.

H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 16:00, Friday 06 December 2013 (8868)
Slow channel in frame problem

Jim and Dave. We continued the investigation of the problem of incorrect slow channel data in the DAQ from Front Ends following the upgrade to RCG2.8.

The problem is more widespread that just h1hiitmy. We have also seen it in h1susitmy. It appears that only the non-filter-module floating-point slow channels are affected. The problem is related the channel list defined by the INI file. There is a point in the slow floating-point channel list at which channels above do not have the problem, channels below all have problems. The problem is actually a channel shift. For h1susitmy the channels are shifted by 3, for h1hpiitmy the channels are shifted by 2. The point at which the shift starts varies from model to model. It is after a few hundred floating point channels for h1susitmy, and immediately for h1hpiitmy.

Finding the break point is not trivial. Many of the slow channels are zero, or have rapidly changing signals. We are getting the data from the NDS and comparing it with a direct EPICS channel access read of the data.

We will work on scripts over the weekend to get more data on the problem. Hopefully when Rolf is here next week we can implement a fix. The silver lining is that little data has actually been lost, the data is being acquired by the wrong channel name.

H1 IOO (ISC, PSL)
kiwamu.izumi@LIGO.ORG - posted 16:00, Friday 06 December 2013 - last comment - 17:22, Monday 20 January 2014(8867)
EOM characterization: good

Alexa, Stefan, Sheila and Kiwamu

Yesterday, we set up an optical spectrum analyzer on the PSL table to measure the characteristic of the EOM. The results look good except for the 24 MHz resonance . The resonance for the 24 MHz sideband is apart from the modulation frequency by 250 kHz or so. However the IMC doesn't need a large modulation depth and the IMC locking has been OK, we are good. Also, I took some impedance data and will put those data together into a DCC document for a record purpose.

The plots below are the measured modulation depth when driven hard as a function of the modulation frequencies. The vertical dashed-lines represent our actual modulation frequencies i.e. f1 = 9099471 Hz , f_mc = 24078360 Hz and f5 = 5 x f1.

Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 15:55, Monday 20 January 2014 (9393)

A document summarizing the measurements and their results is now available in DCC (https://dcc.ligo.org/LIGO-E1300966).

kiwamu.izumi@LIGO.ORG - 17:22, Monday 20 January 2014 (9395)ISC

I kept forgetting to report the important information regarding to the modulation depths. Here are the estimated modulation depths:

   Modulation depths [rad] Peak height measured with OSA RF power at the input
9 MHz 0.1 20 mV 12.3 dBm
24 MHz less than 0.04  less than 3 mV 13.8 dBm
45 MHz 0.07 10 mV 10.8 dBm

The peak height of the carrier light was about 7.3 V. I used 2 * sqrt(V_sideband / V_carrier) to derive the modulation depths.

H1 General
jeffrey.bartlett@LIGO.ORG - posted 15:43, Friday 06 December 2013 (8866)
Ops Summary
LVEA Laser Hazard

08:28 Justin	To End-Y to check on laser setup
08:45 Mark	Moving ARGO arm to End-Y
08:45 Thomas	Optical lever work at ITM-X 
09:00 Sheila	Removing viewport cover for IM2
09:15 Mark	Craning ITM-Y lower structure over beam tube
09:25 Filiberto	Pulling cables by BSC3
09:40 Richard	Out to End-Y
10:30 Scrap metal recycler on site to swap recycle bins
12:55 Cyrus	At X-Arm spool area to terminate Cat-6 cables
13:15 Corey	Out to End-X TMS lab to recover tools for End-Y	
14:30 North Gate Electrical on site to deliver part
LHO VE
kyle.ryan@LIGO.ORG - posted 15:40, Friday 06 December 2013 (8865)
X-end pumpdown prep misc
Removed gasket from 4.5" CFF blank on BSC9 (location of to be installed ESD interlock gauge) and left flange loose to exhaust wet purge air over the weekend -> Started QDP80 and Turbo -> Began pumping on BSC9 annulus
H1 SEI (ISC, SEI)
hugo.paris@LIGO.ORG - posted 15:06, Friday 06 December 2013 - last comment - 15:27, Friday 06 December 2013(8863)
Safe.snap updated for SEI Platforms

Safe.snap files were updated for every SEI platform involved in PRMI.

Soft links were checked, and safe.snap files were commited in the svn.

ISI
HAM2, HAM3                  - r6572
BS, ITMY, ITMX, ETMX  - r6576 


HPI
HAM2, HAM3                   -r6574
BS, ITMY, ITMX, ETMX   - r6577 

 

 

Comments related to this report
hugo.paris@LIGO.ORG - 15:27, Friday 06 December 2013 (8864)

Every plateform involved was turned back on to its current optimal settings.

H1 SEI (ISC, SEI)
hugo.paris@LIGO.ORG - posted 10:24, Friday 06 December 2013 - last comment - 21:09, Friday 06 December 2013(8860)
SEI Controls for PRMI

Below is a summary of the available controls on SEI platforms, for PRMI. Platforms should run under their preferred configuration at all time.

 

HAM1:

HAM2:

HAM3:

BS:
ITMY:
  • ISI: Lv3 Isolation, fed by:
    • Stage 1: T250mHz blend, with T100mHz_N0.44 on X and Y
    • Stage 2: 250mHz
  • HEPI: Position loops ON
ETMX:
  • ISI: Lv3 Isolation, fed by:
    • Stage 1: T250mHz blend, with T100mHz_N0.44 on X and Y
    • Stage 2: 250mHz
  • HEPI: Locked
ITMX - Commissionning to be completed
  • ISI: Damping
  • HEPI: floating

 

Comments related to this report
hugo.paris@LIGO.ORG - 14:38, Friday 06 December 2013 (8862)

Note: The HEPI-BS position loops are in the second set of filter banks. One should use the isolate BS lv2 command button, instead of lv1, for this chamber only.

brian.lantz@LIGO.ORG - 21:09, Friday 06 December 2013 (8872)SEI
work of warning - the level 2 filters attempt to turn on Filter modules 2 and 3, and module 9 for boost
(level 1 uses FM1 for isolation turn on + FM 10 for boost)
one should check that the boost module is OK. It used to be true that attempting to turn on an empty module (FM3) makes no difference, but we should check...
-Brian
LHO VE
kyle.ryan@LIGO.ORG - posted 09:36, Friday 06 December 2013 (8858)
PT120B pressure indication too optimistic -> additional voltage drop in signal wiring?
"Quick" circular AMP connectors had been added to this gauge pair wiring to facilitated disconnection/connection without the need to access the wiring terminations at the gauges themselves.  I suspect a voltage drop across this additional connection accounts for the apparent signal error.  Accessibility is not good to correct -> will live with this until opportunity to correct presents itself
H1 ISC
stefan.ballmer@LIGO.ORG - posted 22:52, Thursday 05 December 2013 (8852)
ODC screens updated
During the last suspension model updates, many SUS models started reporting some additional status bits. I did a first round of cleanup of the overview screens to show all bits.
- fixed the number of bits and the mask names in a series of model specific ODC screens.
- ODC overview screen update:  fixed the numer of bits and switched to the _LATCH version of the ODC channel ( this channel latches for 1 sec.)
- set the bit mask for all SUS and SEI models.

Still to do: 
- number of bits for the BS is different than ITMs - it needs it's own BSC screen
- set the string bit label s
- update IMC model
- in collaboration with SEI: the ISI scripts currently incorrectly set he desired state channels.
H1 AOS
arnaud.pele@LIGO.ORG - posted 20:52, Thursday 05 December 2013 - last comment - 20:50, Friday 06 December 2013(8849)
TMSX TF : potential rubbing

A set of matlab transfer functions has been ran on the TMSX this afternoon after BSC9 was closed out, and while the ISI was damped. The pitch degree of freedom shows some excess noise between 0.7Hz and 3Hz, which is something I was not expecting to see since the measurement after the last work accomplished on TMSX was clean.

It might be related to some excess motion at the time of the measurement during the afternoon, which I will check by running undamped and damped TFs overnight in a quiter environment. We will see how repeatable the measurement is tomorrow morning.

It might also be the position of the cables that could have changed by themselves because of their weight. Or maybe some work that I'm not aware of that was done after the last measurement taken. In those cases we would probably need to physically check what is going on.

Results attached are described below :

(1) Comparison between the model and last TMSX TF

(2) Comparison between TMSX after the work done on Nov 20th (Orange trace), after the last time work has been done on Nov 22nd (black trace), and today (pink trace).

See the 5th page of (1) and (2) for the pitch dof

Non-image files attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 09:13, Friday 06 December 2013 (8857)

Looking at the new results from this morning, everything seems fine, and tf from overnight are not showing any problems. Plots pending.

arnaud.pele@LIGO.ORG - 20:50, Friday 06 December 2013 (8871)

In fact, after investigating a little bit more, and looking at the pitch motion at the suspension point of the TMSX, it looks like the ISI was moving in Pitch at low frequency during that measurement. The 3rd attached pdf shows in blue the pitch input motion during yesterday afternoon's TF (noisy measurement), and in green during the overnight TF.

The other two pdfs are showing the results with :

(1) a comparison between yesterday afternoon's TF and the one taken overnight

(2) a comparison between and LLO and LHO undamped TMSX tfs

Results are very clean and similar to model and LLO's data.

Non-image files attached to this comment
H1 IOO (ISC)
kiwamu.izumi@LIGO.ORG - posted 20:34, Thursday 05 December 2013 - last comment - 09:11, Friday 06 December 2013(8851)
IMC left locked

I am leaving the IMC locked for the night in order to see its stability. The ASC loops are all engaged.

It must be rock-solid because we fixed the EOM !!

An auto-locking script is locally running on opsws4. The script itself resides in /opt/rtcds/userapps/release/ioo/h1/scripts/imc/sballmer/ and it is called MClockwatch.

Comments related to this report
kiwamu.izumi@LIGO.ORG - 08:14, Friday 06 December 2013 (8855)

We obtained a 9 hours of overnight lock stretch. It dropped the lock at 7:55 am in this morning for some reason which I haven't investigated yet.

At 10 pm local last night, I found that the ref cav was having a trouble in relocking. It was due to a too low transmitted light, resulting in a non-ideal trigger for relocking. Probably some optics drifted and misaligned. I decreased the threshold from 0.9 to 0.7. Then FSS started locking fine.

The attached is trend of 12 hours from this past night.

Images attached to this comment
kiwamu.izumi@LIGO.ORG - 09:11, Friday 06 December 2013 (8856)PSL

Indeed, the alignment of the reference cavity somewhere got drifted. It seems that it is mainly in pitch. It is visible in the ref can reflected camera -- see the attached picture. The reflected light started showing a halo on the upper side.

Figure: Quad view of the PSL cameras, taken at around 9 am. this morning (6/December/2013)

RefCav Trans

PMC Refl
RefCav Refl PMC Trans

Table: Quad video's signal assignment.

 

BTW, you can now take a picture of the videos by running Chris's excellent script:

/ligo/home/christopher.wipf/Public/Data/2013-11-20_video/gst-camera-framecapture

Of course, this is a temporary place and we will move this script to somewhere appropriate at some point.

Images attached to this comment
H1 CDS
david.barker@LIGO.ORG - posted 18:06, Thursday 05 December 2013 - last comment - 10:40, Friday 06 December 2013(8846)
DAQ problem with HEPI ITMY slow channels

Hugh noticed that some HEPI ITMY slow channels were not correct in the DAQ. I did some investigation and found:

Of the slow channels (datarate=16) in H1ISIITMY.ini :

channels associated with the FEC were correct

channels associated with Filter Modules were correct

other slow channels were incorrect, either showing zero or other data (like channel hopping)

Fast channels appear to be OK (within the limited sample I used)

The problem is not seen with HEPI BS or ETMX. Looking at the models they all look identical.

Reboot/Restarts:

I first restarted h1hpiitmy. Then tried restarting all models on h1seib1. Then tried a restart of the mx-streamers. Then recompiled and reinstalled the h1hpiitmy model and restarted it, followed by a DAQ restart (DAQ status was good, so this should have been unnecessary). All to no avail.

The only thing I haven't done is reboot the computer.

It appears this problem appeared when we upgraded to RCG2.8 on Tue 12 November.

Comments related to this report
keith.thorne@LIGO.ORG - 06:57, Friday 06 December 2013 (8853)
We'll have to look at those channels here at LLO (once I figure out which ones they are...).
A contributing factor may be that mx_stream driver update was not explicitly listed in the RCG 2.8 upgrade instructions.  There were changes from 2.7.2 (but none appear linked to 2.8).  This driver can be updated now, but would require mx_stream restarts (or even front-end restarts to load new kernel image).
keith.thorne@LIGO.ORG - 10:40, Friday 06 December 2013 (8861)
Celine has checked some of those channels here at LLO and is not seeing the same issue, either on MEDM screens or values on the DAQ.
H1 IOO (IOO, ISC, PSL)
kiwamu.izumi@LIGO.ORG - posted 20:41, Wednesday 04 December 2013 - last comment - 07:59, Friday 06 December 2013(8821)
The mysterious RF phase jump was due to a loose connection in the EOM box. It is now fixed.

Stefan, Sheila and Kiwamu with remote assistance from Rich A. and Volker

The mysterious jump in the RF phase (see alog 7941) is now understood and fixed. It was due to a loose connection at DB15 connectors in the EOM box and not due to the SMA connector (see alog 8811 and 8813 for our early detective story). We applied two small in-situ modifications on the EOM box. As a result, now it doesn't show the mysterious RF jump any more.coolcoolcoolcoolcool

 

The box:

I briefly explain the EOM box for those who are not familiar with our custom-made EOM box. The EOM box consists of two boxes -- one contains LC resonant circuits and the other contains the EOM crystal. This two-boxes-design allows one to tune the resonant frequencies by tweaking the LC circuits without messing up the alignment of the EOM crystal because one can simply take out the electronics box and leave the crystal box for solder or tuning some parts in the circuits. To apply voltage across the EOM crystal for normal operation, the LC circuits need to be connected to the EOM crystal. This is done by a DB15 connector attached on each box -- female DB15 on the crystal box and a male DB15 on the electronics box (see pictures shown below). In this way, the two boxes are electrically connected.

A picture of the actual EOM box. The gloved hand is me pressing the SMA downward in order to reproduce the RF jump.

When I pressed the SMA connectors downward in this morning, the RF characteristic of the EOM box changed as if something jumped. This was repeatable, although it seemed that the condition to make it jump was random -- occasionally, pressing the SMA didn't make it jump and sometime pushing the SMA toward the box made it jump. Anyways, at this point, it was clear that the EOM box was the culprit and not the RF cables.

The causes:

At the beginning, we thought the culprit was the SMA connectors (see alog 8811 and 8813). However, this turned out to be wrong as we investigated it further. With a remote assistance from Volker, Stefan and I took the electronics box apart from the crystal box while keeping the crystal alignment. In the process of removal, we found that the electronics box was attached to the crystal box merely by friction of the DB15 connectors and three pieces of adhesive tape. So the orientation of the electronics box was not so solid with respect the EOM box. We then checked the return loss of the LC circuits without connecting the EOM and confirmed that wiggling the SMA connector didn't change its impedance. Instead, we discovered that the DB15 connector can easily change the amount of its stray capacitance -- the frequency of the resonant notch could shift by approximately 1 MHz by very gently touching the DB15 connector with our latex-gloved-hand. We put the electronics box back on the EOM crystal box and wiggled the orientation of them. Indeed, it changed the resonant frequency by about 1 MHz in a discontinuous way. So we determined that the loose connection in the DB15 connectors was the culprit and the mysterious RF jump was induced by some change in the orientation of the two boxes.

It seemed that the DB15 connectors were not all the way in because the two aluminum boxes contacted first.

The repair/modification fixed the issue:

We did the following two repair/modification:

The DB15 connector have two screws to support it and we put a washer for each screw. They raise the height of the DB15 connector like shims. Also, we newly installed four screws to make the connection of the two boxes more solid. There were already four screw holes on each box to accommodate them. So we just installed them. After these modifications, we checked the return loss of all three RF ports. We didn't observe the mysterious jump at all, even when the electronics box was wiggled hard. Of course, strongly pressing the electronics box downward shifts the notch position by an order of 10 kHz due to the change in the stray capacitance at the DB15 connectors, but the shift is smooth and not in a discontinuous way any more. So the RF jump issue is now solved.

A picture of the electronics box when apart from the EOM crystal box. This DB15 connector was shimmed by washers.

A picture of the EOM crystal box when the electronics box is taken away. There is a threaded screw hole on each corner and these are the ones we used for installing the new screws.

 

A top view of the EOM box with the lid off. The green circles indicate the screws that we newly installed.

 

A top view of the EOM box with the lid off. The green circles indicate the screws that we newly installed.

Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 22:26, Wednesday 04 December 2013 (8824)

Here are the return loss of all three ports after the modification:

Also raw ASCII data of these plots in csv format are attached too.

Images attached to this comment
Non-image files attached to this comment
jodi.fauver@LIGO.ORG - 08:08, Thursday 05 December 2013 (8829)
Does this mean that someone would like to modify the 3IFO version of the EOM box?
peter.fritschel@LIGO.ORG - 07:59, Friday 06 December 2013 (8854)

A DB15 connector to pass RF signals, not to mention they're the RF signals that produce all the interferometer error signals ... speechless.

H1 TCS (TCS)
thomas.vo@LIGO.ORG - posted 16:40, Wednesday 04 December 2013 - last comment - 09:38, Friday 06 December 2013(8816)
TCS ITMY Ring Heater
Steps taken to commission the ITMY ring heater pair:
- Updated to the recently committed Beckhoff code that Joe B and Adam M worked on yesterday.
- Added the calibration values that Aidan B had recommended for running the ring heaters.
- Opened up a strip tool to monitor the vacuum pressure with the closest gauge (HVE-LY:Y1_120BTORR)
- Turned the ring heaters on to low power (~.01 Watts) to make sure that the channels were working properly
- Increased the power to 1 Watt for a 4 hour period starting at 12:00PM Pacific Time, keeping an eye on the pressure gauge previously mentioned.


Upper:
Requested Power = 1.00 Watts
Measured Voltage = 5.94 Volts
Measured Current = 0.17 Amps 
Calculated Power = .99 Watts
Calculated Resistance = 34.94 Ohms

Lower:
Requested Power = 1.00 Watts
Measured Voltage = 5.92 Volts
Measured Current = 0.16 Amps 
Calculated Power = .98 Watts
Calculated Resistance = 37.0 Ohms

A four hour trend of the pressure gauge and ring heater settings is attached.

A quick, back-of-the-envelope calculations shows that the ring heaters are working properly. The next step for measuring the thermal lensing would be to measure the beam diameter of a single reflection off of the back of ITMX independently and then changing the radius of curvature of ITMY using the ring heater to match. This requires looking at the REFL beam either in the HAM1 chamber or on the ISCT1 table, depending on how much power we are able to get out of REFL.  The Thorlabs beam profile we have on site requires a minimum of ~1e-5 Watts of incident beam power to function.
Images attached to this report
Comments related to this report
mindy.jacobson@LIGO.ORG - 09:38, Friday 06 December 2013 (8859)AOS, TCS
NOTE:
This pair of upper and lower ring heater segments is due to be replaced, per "Bug255"
https://services.ligo-wa.caltech.edu/integrationissues/show_bug.cgi?id=255

See, also, T1300463
Displaying reports 75041-75060 of 83634.Go to page Start 3749 3750 3751 3752 3753 3754 3755 3756 3757 End