Displaying reports 75201-75220 of 83552.Go to page Start 3757 3758 3759 3760 3761 3762 3763 3764 3765 End
Reports until 10:53, Tuesday 19 November 2013
H1 CDS (ISC, SUS)
david.barker@LIGO.ORG - posted 10:53, Tuesday 19 November 2013 (8623)
install new h1omc model, clear stuck SUS excitation test point

Chris, Arnaud, Dave

Chris installed a new h1omc model onto h1lsc0. We got special permission from Mike L to do this during this week's code freeze. After the restart we restarted the DAQ to apply the modified INI file. We found that several other ISC systems had modified INI files which required pressing the "DAQ Reload" button on the following systems: h1lsc, h1asc, h1iscex and h1iscey.

We noticed a stuck excitation test point on h1susitmy (channel 145). We had to perform a "tp clear 30 *" to clear it.

H1 AOS
jason.oberling@LIGO.ORG - posted 10:42, Tuesday 19 November 2013 (8620)
WBSC3 ITMx Alignment, Final Number Collection
Putting all the final alignment numbers for ITMx into one log to make it easier to find in the future.

1: We had to tear down our equipment at the X manifold spool for the spool re-install before the ITMx HR First Contact was removed, therefore we will not get a chance to measure the pitch after the FC removal.  We have to trust that the calculations in E1200791 are correct and the ITMx pitch will be within ±50 µrad of its 619 µrad down target pitch after the FC is removed.

H1 SUS
betsy.weaver@LIGO.ORG - posted 09:28, Tuesday 19 November 2013 (8619)
backlog alog - PR3 baffle installed

This alog should have been filed before Jim's below:  Yesterday, Calum and I installed the new PR3 baffle, prior to Jim's balance of the HAM2 table.

H1 IOO (IOO, PSL)
cheryl.vorvick@LIGO.ORG - posted 23:00, Monday 18 November 2013 (8617)
IO work in HAM2 and HAM3

- Kiwamu, Keita, Cheryl


- checked MC REFL rerouted as IMC TRANS alignment through the irises and FI and to PSL ISS - good
- checked flashing IMC through irises and FI and to PSL ISS - good
- set up PSL ISS QPD to read the signal from 1064nm light - was able to see DC change with MC REFL beam when blocked and unblocked
- removed iris hardware from HAM3 stage 0
- removed irises from HAM2 table top
- proposed to MikeL that Keita and Kiwamu align the beam to the PSL ISS, now that software is set up - not sure if this happened

Also:
- noted that the PSL ISS was out of position w.r.t. top level assembly drawing for HAM2
- noted that the curved steering mirror for the PSL ISS, AROM RH2, was out of position w.r.t. top level assembly drawing for HAM2
- noted that the baffle, HA11, is out of position w.r.t. top level assembly drawing for HAM2

I've emailed Calum about the position difference of the PSL ISS.

Images attached to this report
H1 ISC
keita.kawabe@LIGO.ORG - posted 18:43, Monday 18 November 2013 (8616)
EX work today (Alexa, Sheila, Stefan, Keita)

Reference: TRANSMON ISC EX Layout D1201457

  1. Put a reference flat mirror between M5 and telescope, and the beam didn't retroreflect when QPD servo was ON.
    1. This means that the bottom periscope mirror under the TMS ISC table is exonerated.
  2. The beam was pretty well centered on M2 but too high on M1 and M3, so changed PIT if M2.
    1. We ended up splitting errors between M8 and M1, M1 being too high and M8 too low but good on M3.
  3. Used M3 and M6 to steer the beam spot on the primary and the secondary to mimic what's supposed to be good according to https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=7285.
  4. Used TMS BOSEM bias to rotate the entire thing so the beam retro-reflects off of ETMX.
    1. Unfortunately we needed a large YAW offset and the F2 and F3 DAC railed.
  5. I'll talk with SUS people to find the best way to mechanically rotate the TMS suspension in YAW. We'll probably move the top blade.
H1 INS (SEI)
jim.warner@LIGO.ORG - posted 17:57, Monday 18 November 2013 - last comment - 18:04, Monday 18 November 2013(8614)
HAM3 ISI Locked, HAM2 ISI Unlocked

This afternoon, HAM3 was locked, to allow various other sub-systems in to take pictures, make adjustments, etc. Meanwhile, Betsy and Calum installed the new baffle at HAM2, so Greg and I were able to go in and refloat that ISI. Somewhere in there, I also reconnected a disconnected CPS sensor. This could have been poorly attached, but I have also heard tell that people have been walking in the nozzles of this chamber. This should be done with extreme caution as the CPS feedthrus are particularly vulnerable, and would probably break if stepped on.

I attempted to start TFs on HAM2, but was foiled by an awgstream issue that I'm not smart enough to fix. Will try again in the morning.

Comments related to this report
jim.warner@LIGO.ORG - 18:04, Monday 18 November 2013 (8615)

Nvm. Looks like Matlab 2012 is smarter than I am. TF's ARE running on HAM2 now. Let's hope they last the night.

H1 SUS
arnaud.pele@LIGO.ORG - posted 17:54, Monday 18 November 2013 (8613)
matlab tfs

[Jeff K. Arnaud P.]

The TF of ITMX ran over the week end from matlab 2012b, had the same issue that I encountered on friday morning. The log file saved gives the following error message :

[Warning: Channel H1:SUS-ITMX_L1_WIT_Y_DQ incorrect time 1068669185 (expected 1068669184).]
[Warning: Error in query for H1:SUS-ITMX_L1_WIT_Y_DQ: unknown error]
[Warning: Response channel H1:SUS-ITMX_L1_WIT_Y_DQ has sampling frequency higher than 256 Hz, decimating to the lower rate ...]
[> In get_sch_TF_MO_v9DQ_sma at 384
  In collect_schroeder_TF_v9DQ_sma at 479
  In Matlab_TFs at 499
  In LHO_Matlab_TFs at 141]
Error using decimate>validateinput (line 158)
The input signal X must be a double-precision vector.

So we investigated and fixed the problem which was basically :

Since we have higher sampling rates for the new witness channels recently implemented, (L1_WIT_$DOF_DQ / L2_WIT_$DOF_DQ), the function "get_sch_TF_M0_v9DQ_sma.m" was trying to downsample those channels to 256Hz right after getting the data out of the frame. If the function get_data failed (randomly the case), it would try to decimate an empty vector, and was returning the above error and quit the script. 

We modified get_sch_TF_M0_v9DQ_sma in order to make sure the data is beeing recovered in a while loop before decimating the signal.

I will run an other set of TF on ITMX tonight and commit the changes tomorrow if it succeeds

H1 ISC (ISC)
rich.abbott@LIGO.ORG - posted 17:50, Monday 18 November 2013 (8612)
HAM6 Electrical Components Installation
Alexa, Kiwamu, Rich

Did more in-vacuum installation work in HAM6.  Tip/Tilts and Beam Diverters are all installed.  The only remaining electrical devices to install are the Picomotors.  It's getting a bit busy in there, and we didn't want to add more stuff without talking to the alignment folks.  Dogged things down with one dog each anticipating they will be moved.

******USE CARE MOVING THE TIP/TILTS, I TOOK THE OPTICS OFF THEIR STOPS******

Missing a few key electronics items in the chain, so electrical checkout is still pending on all these items.

Tip/Tilt OM1
Serial Number of Tip/Tilt stage - 002
External Cable Number 236
Flange D6-F10
Internal vacuum cable S1106728

Tip/Tilt OM2
Serial Number of Tip/Tilt stage - 004
External Cable Number 237
Flange D6-F11
Internal vacuum cable S1106834

Tip/Tilt OM3
Serial Number of Tip/Tilt stage - 033
External Cable Number 238
Flange D6-F12
Internal vacuum cable S1106830

Beam Diverter #1 (AS)
Diverter Serial Number 012
Flange: D6-F8
External Cable 317
Internal Vacuum Cable (Flange to Table Bracket) S1202649
Short Cable (Bracket to Diverter) S1202732

Beam Diverter #1 (OMC REFL)
Diverter Serial Number 019
Flange: D6-F9
External Cable 316
Internal Vacuum Cable (Flange to Table Bracket) S1202652
Short Cable (Bracket to Diverter) S1202730
H1 AOS (AOS)
thomas.vo@LIGO.ORG - posted 17:33, Monday 18 November 2013 (8611)
Optical Lever Maintainence and Realignment HAM 2-3
Robert S. Thomas V.

After adjusting the pylon positions for the HAM 2&3 optical levers to relieve pressure off the bellows, we needed to do a realignment of the in-chamber transceiver optics.  This was completed relatively smoothly and from an optical lever stand point, we're ready for pump down. Yay.
LHO General
patrick.thomas@LIGO.ORG - posted 17:26, Monday 18 November 2013 (8601)
Ops Summary
08:56 Louis going to end Y to work on cable cleanup on the VEA mezzanine
09:26 Betsy looking for parts in the LVEA
10:10 Mayflower metals to swap recycling bin
10:39 Justin transitioning the LVEA South Bay to laser hazard
Cleaning in end Y VEA
Cheryl, Kiwamu, Keita aligning the IMC
Kyle venting end Y
11:56 Cheryl going into HAM3
12:28 Cheryl, Kiwamu, Keita done with IMC work
12:29 Jeff B. done working in HAM6
13:25 Justin transitioned the LVEA to laser safe
Doug and Jason setting monuments at end Y
Calum, Kate, Norna installing baffle
14:34 - 14:50 Richard on corner station roof
Apollo breaking bolts on cyropump spool at end Y
LHO VE
kyle.ryan@LIGO.ORG - posted 16:20, Monday 18 November 2013 (8610)
Vented Y-end


			
			
H1 CDS
cyrus.reed@LIGO.ORG - posted 16:15, Monday 18 November 2013 (8609)
H1FE Switch Configuration Changes

I have disabled the broadcast storm control feature in the FE network ethernet switches.  I suspect the feature is dropping CA broadcast traffic when IOCs go offline, as the number of channels is significant for even one host; this will negatively impact the ability of systems to reconnect to channels when the come back up, and just extend the period of time the broadcasts are active.  There was a marked reduction in the level of dropped frames on the FE network when dc0 was changed to collect EPICS data via the OpenMX network, but there are still peaks of dropped traffic (at a reduced rate).

H1 ISC (ISC, SUS)
jeffrey.lewis@LIGO.ORG - posted 14:34, Monday 18 November 2013 - last comment - 11:03, Tuesday 19 November 2013(8608)
OMC placed in HAM6
Koji A., Jeff B., Andres R., Jeff L.

The OMC was moved into HAM6 this morning.  The move from the cleanroom and into the chamber was smooth with no issues.  The OMC is sitting off to the North side of the ISI table to allow access for IAS.  The cookie cutter (used to position the OMC structure) is attached at the correct location on the ISI table for future use.  The structure is held with a few dog clamps.  The rest of the dog clamps, screws and washers are in a foil bag next to the structure in the chamber.
Images attached to this report
Comments related to this report
dale.ingram@LIGO.ORG - 11:03, Tuesday 19 November 2013 (8624)
The two Jeffs took pictures of the OMC going in; a subset of these now sits in ResourceSpace.
H1 ISC (ISC)
koji.arai@LIGO.ORG - posted 14:27, Monday 18 November 2013 - last comment - 17:26, Sunday 08 December 2013(8607)
OMC preamps isolated from the OMCS structure

[Jeff B, Andres R, Rich A, Jeff L, Koji A]

We successfully resolved the grouding issue of the OMC preamps, thanks to the help provided from Peter K, Rick S, and Betsy B
for the necessary isulating materials. Here is the note for ourselves and someone who may work on this insulation for L1 and 3IFO.


The grounding of the ISC cables were caused by the mounting of the preamps (attached figrue, left). The PEEK washers
were used to isolate the bracket from the structure. In order to fit the wahsers, we had to trim them (only for the outer one) with crimpers.
In order to isolate the 1/4-20 screws from the hole walls, we used Kapton tubes. Since the diameter of the tube was too big
for the hole, we had to open the tube and trim it to reduce the number of turns. In addition, the metal washers should have
been removed as they sneakily caused the grounding with the preamp.

Images attached to this report
Comments related to this report
koji.arai@LIGO.ORG - 17:26, Sunday 08 December 2013 (8876)ISC, SUS

Additional note (Dec 8)

The preamps are touching the cable for the PZT signals. Therefore the installation of the isolation kit should be done
without removing the adapter plate in order to avoid misalignment of the glass breadboard.

This can be done by installing the isolation kit one side at a time:
1. Loosen the two 1/4-20 caps
2. Remove one of the screws while the adapter plate was kept at the installed position.
3. Insert an unmodified PEEK washer between the SUS structure and the adapter plate.
4. Put a trimmed PEEK washer on a screw. Roll a kapton tube around the screw.
5. Insert the screw combo into the screw hole.
6. Turn the inserted screw (not fully)
7. Repeat 2 to 6 for the other screw
8. Tighten the two screw.
9. Check the isolation between the preamp housings and the SUS structure.

H1 AOS
joseph.gleason@LIGO.ORG - posted 13:50, Monday 18 November 2013 (8606)
PSL power control rotation stage cabled, ready for install in beam path
Peter King, Joe Gleason

We ran the cables coming from the ether-cat chassis into the PSL for the mechanized rotation stage and connected them to the controller box on the PSL table. We also connected the lock out mechanism cable to the box and ran that cable outside the PSL near the Light Pipe. The excess is coiled up behind the cooling pipes under the light pipe area and needs to have the lock out device attached and the box mounted to the wall. Once the lock out box is attached and mounted the stage can be tested and installed in the beam path with the HWP from the old stage. Currently the stage is sitting along side the mechanical stage on the PSL table.
H1 IOO
joseph.gleason@LIGO.ORG - posted 13:41, Monday 18 November 2013 (8605)
PR2 scraper baffle re-work and install completed in HAM3
After discussing the issue of an interfering table mass last week we elected to move the mass 2" in -Y to allow the PR2 scraper baffle to be installed in the correct location using the cookie cutter. There were no further issues encountered and the work is now complete. I placed the old baffle Z plate on a shelf in the clean room outside HAM2 that will need to be sent back to UF for modification.
H1 CDS
cyrus.reed@LIGO.ORG - posted 13:41, Monday 18 November 2013 (8604)
DNS Server OS Updates

I've run the latest security updates on the two CDS nameservers, and rebooted them this morning.

H1 TCS (TCS)
thomas.vo@LIGO.ORG - posted 19:49, Wednesday 13 November 2013 - last comment - 10:28, Monday 18 November 2013(8522)
TCS ITMX In-Vacuum Mirror Alignment
Alastair H. Greg G. Robert S. Thomas V.

We were able to complete the alignment of this set of mirrors tonight. One of the 10-24 vented SHCS on the back of the SM2 mirror in BSC2 got bound up and broke at the head but we decided to move forward with the installation and were able to get the mirror secured.  Although all the bolts are tightened down to their capacity on both mirrors, the alignment is still vulnerable to being bumped.
Comments related to this report
mindy.jacobson@LIGO.ORG - 10:28, Monday 18 November 2013 (8603)
The location of the broken and the loose bolts are identified in the attached sheet (2) of the assembly drawing
Non-image files attached to this comment
Displaying reports 75201-75220 of 83552.Go to page Start 3757 3758 3759 3760 3761 3762 3763 3764 3765 End