Displaying reports 75241-75260 of 83551.Go to page Start 3759 3760 3761 3762 3763 3764 3765 3766 3767 End
Reports until 13:05, Friday 15 November 2013
H1 SUS
betsy.weaver@LIGO.ORG - posted 13:05, Friday 15 November 2013 (8577)
HAM2/3 TFs

I'm finishing up my last set on PRM (HAM2).  Jim is going in to start work on rebalancing the HAM3 ISI.

H1 ISC
stefan.ballmer@LIGO.ORG - posted 11:30, Friday 15 November 2013 (8576)
TMX green QPD gain per segment check
Alexa, Stefan,

To verify that the Green QPDs on TMSX all have comparable segment gains, we steered the beam on all 8 segments. The whitening gain was set to 30dB.

QPDB:
Seg 1  14060 cts
Seg 2  14000 cts
Seg 3  13900 cts
Seg 4  14300 cts

QPDA:
Seg 1  15900 cts
Seg 2  17500 cts
Seg 3  17100 cts
Seg 4  16200 cts

QPD A was somewhat more difficult - depending on the QPD B pointing, the beam can clip before reaching the peak value on QPDA.

The gains are withing 10% of each other.

H1 SUS (SYS)
betsy.weaver@LIGO.ORG - posted 10:26, Friday 15 November 2013 - last comment - 13:24, Friday 15 November 2013(8573)
MC TFs in prep for next week's First Contact chamber closeout

We need a single DOF TF on each of the optics we are cleaning next week in order to run a comparison against  "on the fly" after pulling the First Contact.  So, I am going to run a few this morning to make new references.  I'll take MC1, MC2, MC3, and PRM data.

Comments related to this report
betsy.weaver@LIGO.ORG - 13:24, Friday 15 November 2013 (8578)

Data is stored in svn appropriate directories dated 2013-11-15_1104.

H1 SUS
betsy.weaver@LIGO.ORG - posted 09:30, Friday 15 November 2013 - last comment - 10:45, Friday 15 November 2013(8572)
ITMx TFs running right now

The ITMx TFs failed last night so we are running them with DTT right now.

Comments related to this report
arnaud.pele@LIGO.ORG - 10:45, Friday 15 November 2013 (8574)

TF are done, and look satisfying. Results pending

IAS can break down their equipment

H1 SUS (ISC)
jeffrey.kissel@LIGO.ORG - posted 09:20, Friday 15 November 2013 (8571)
H1 SUS OMC DAMP Filters installed
J. Kissel, S. Aston

I've installed damping filters using exactly what L1 is using (see LLO aLOG 9724). It may not be the most awesomely tuned filters and gains, but it's good enough for now.

L = -6.00
T = -3.00 
V = -5.00 
R = -0.40
P = -1.50
Y = -3.00

Each DOF should have filter banks FM1(0:30,30), FM5(normX) and FM10(Ellip50) engaged. (Note there are other experimental filters lying around in some FMs of some DOFs. Try not to get confused. When we advance to Level 2 filters, we'll clean these up.)
Images attached to this report
H1 PSL (PSL)
peter.king@LIGO.ORG - posted 09:07, Friday 15 November 2013 (8568)
Second Loop Power Stabilisation Photodetector Array Installation
The second loop power stabilisation photodetector array was installed in HAM2.  Unfortunately the beam
used for the alignment of the photodetector, the reflected beam from MC3, had the wrong polarisation.  One
consequence of which is that the expected signals levels on the quadrant photodiode were a lot lower.  This
will not be the case when the real beam into the interferometer is restored.

    The beam into the array was aligned through through the input alignment aperture such that the output
of the eight individual photodiodes was peaked.  In the end the output of one of the eight diodes was 
somewhat lower than the others.  This is not because of a problem with the photodiode but because the
input beam alignment was not optimised.  The parameter space of one end of the input beam alignment can
be explored by using the Picomotor driven mirror - the last mirror in the optical path to the photodetector
array.

    More details to follow in a later entry.

J. Gleason, P. King, R. McCarthy, O. Puncken, R. Savage
H1 SUS (ISC, SUS)
koji.arai@LIGO.ORG - posted 00:31, Friday 15 November 2013 (8567)
OMCS masses aligned/positioned

[Jeff B, Andres R, Koji A]

Prior to the OMCS TF measurements...

The OMC was fully cabled up (i.e. OMC DCPDs, QPDs, PZTs, DCPD Preamps, 5 BOSEMS)

The height and balance of the OMC glass breadboard on the OMCS were adjusted.

Then BOSEM positions were adjusted so that the flags are centered in the aperture.
The BOSEM longitudinal positions were adjusted so that the flags blocks half of the light.

H1 SUS (CDS)
jeffrey.kissel@LIGO.ORG - posted 21:03, Thursday 14 November 2013 (8566)
H1 SUS OMC 4R'd -- now BIO Monitors are Functional
A. Pele, J. Kissel

After I had quickly glossed over the front-end model for the H1SUSOMC and declared it error-free, I sent Arnaud and Fil on a wild electronics goose chase for two hours before Arnaud came back in and found the flaw in the digital system in 5 minutes (cf LHO aLOG 8563). Mea cupla, gents. 

We've fixed the error in Simulink, and now that transfer functions are complete (see LHO aLOG 8565), I've re-compiled, re-installed, re-started, and re-stored (4R'd) the SUS to functionality. Further, I've confirmed the BIO monitor / readbacks work like a charm.

Next time, I'll follow Arnaud's advice: try to drive an offset out to the suspension and confirm no displacement from the OSEM speed-dials before declaring the BIO non-functional. My better judgment was polluted by too many encounters with turned off BIO drivers (which freezes their EPICs values), and the PUM driver low-voltage problem (see LHO aLOG 1278).
H1 SUS (ISC)
jeffrey.kissel@LIGO.ORG - posted 20:43, Thursday 14 November 2013 (8565)
H1 SUS OMC Transfer Function Results -- Off by a factor of 5.5
J. Kissel, K. Arai

After Arnaud and Fil graciously debugged the binary I/O for the H1 SUS OMC (see LHO aLOG 8563), I began and finished a round of DTT transfer functions to clear the suspended dynamics. While the frequency dependence looks great and as expected, there appears to be an anomalous scale factor of 5.5 in all degrees of freedom. Since the scale factor is identical in all degrees of freedom it implies something is Arai (teehee, couldn't resist) with the electronics or digital chain and not something inherent to the dynamics.

As such, I've vetted the digital portion of the chain:

- Measurement calibration factor (i.e. post-processing measurement analysis)
    - L1 uses 0.26193 [(m/ct) / (N/ct)] (see, e.g., LLO aLOG 9570) -- is the same as used here to calibrate this measurement, and L1's measurements match the model well (certainly not off by a factor of 5.5). Therefore the post-processing scale factor is the same (It's not that we forgot the 18 vs. 16 bit DAC factor of 4 or that we have the wrong coil driver transconductance or coil-magnet gain compensation, etc.).
    - (Not attached, but) I made the same plots but dividing the measurement by a further factor of 5.5 (exactly, which is how I got the number), and the measurements line up with L1's measurements excellently, and which all match the model to within ~1.0%.

- EPICs Values
    - The OSEMINF Calibration Filters ("to_um") are turned ON (and the maltab processing code has meas.sensCalib = true)
    - OSEM2EUL and EUL2OSEM matrices are as produced by make_susomcs_projections.m, which is what L1 uses to install their matrices.
    - No excess gain in the SENSALIGN matrix; an identity matrix as expected
    - No excess gains in the TEST filters
    - The OSEM sensor normalization gains in the OSEMINF bank are roughly 1.3 to 1.4, as expected, no gains close to 5.5
    - The COILOUTF filter magnet polarity gains are +/- 1.0 as expected
    - The DRIVEALIGN matrix is no longer in the TEST excitation path, so that can't screw us up 

- Foton Filters
    - The OSEMINF filters have the expected DC gain (10:04 has a DC gain of 1.0, "to_um" has a DC gain of 0.02333)
    - The COILOUTF filters are all engaged and all have a DC gain of 1.0
    - The DAMP filters are not installed, but they're inconsequential to this undamped measurement


In summary, I confirmed that everything digital in the transfer function path is OK, and I confirmed that all post-processing is identical. So -- I've been wrong that it wasn't a digital problem once already this evening, but -- I don't see anything that could be wrong other then the analog electronics chain. We'll investigate more tomorrow morning.

If we're really pressed for time (i.e. we must install tomorrow or man-power to install evaporates) -- after we install the damping filters (quick), and get a set of damped transfer functions (1.5 hours), I vote we punt debugging this until after install. Unless anyone knows of something obvious...
Non-image files attached to this report
H1 SUS
arnaud.pele@LIGO.ORG - posted 18:59, Thursday 14 November 2013 (8564)
ITMX TF

ITMX undamped TF will run overnight from ~1.50 am on opsws6, and will be running for 2*4hours (Main+Reaction chain)

H1 SUS
arnaud.pele@LIGO.ORG - posted 18:50, Thursday 14 November 2013 (8563)
OMC BIO

[Jeff K. Fil Koji Arnaud]

Koji wanted to run some TF tonight for OMC but switching the coil driver filter state from the BIO screen wouldn't change its readback.

After Fil made sure that the analog filters were being physically enabled by the digital switch (thank you Fil), we realized the problem was on the model side, because BIO_M1_MON_In was grounded.

Since it's only a readback issue, Jeff started the TFs, and we will recompile the model tomorrow morning.

H1 SUS (SUS)
rich.abbott@LIGO.ORG - posted 17:31, Thursday 14 November 2013 (8561)
ESD
Looked at the connections to the H1 ITMX ESD starting at the airside of the vacuum feedthrough.  There is no evidence that there is any connection being made to ANYTHING inside the vacuum system.  In the process of analyzing this, I installed the Delrin insert on the airside of the vacuum feedthrough and very carefully connected the coaxial cables.  Truly no way it's connected on the inside of the vacuum flange.

H1 ISC
keita.kawabe@LIGO.ORG - posted 16:37, Thursday 14 November 2013 - last comment - 17:55, Thursday 14 November 2013(8554)
Some optic(s) might have moved on TMSX ISC table (Alexa, Sheila, Stefan, Keita)

Summary: Some optic(s) might have moved after the TMS was moved out of the lab.

After the beam centering on QPDs is engaged, the QPDs were nicely centered but the beam spot on the 2ndary was about 3mm off centered to the left, the beam is clipped on the F2 already, and only half or less of the beam makes it to the ETM.

If the TMS ISC table is as was adjusted in the lab, the beam spot should be slightly to the right and a few mm down (https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=7285), so there's a huge difference between what we expect and what we are observing now. There are two possibilities:

In the latter case we somehow need to realign the green and IR beam to the telescope and recenter the green and red QPDs, all in situ. I'm working on a procedure to do this.

Checking that we're not fooling ourselves.

Sensing electronics offset? -> Exonerated (changing whitening gain didn't change the beam position though it increased the QPD signal)

Beam clipping downstream of Mad City Labs PZTs? -> Exonerated. No clipping in chamber, and the beam looks OK in chamber.

Different gains for quadrants? -> Asked Stefan to check by bringing the beam in one quadrant, one by one.

Ghost beam?

Wrong polarization (which might produce strong ghost beams)?

Identifying what moved and why.

We don't have any good idea to pinpoint what moved except that it should be downstream of the first steering mirror, and either upstream of the secondary or in the QPD path. Optics mounted at the edge of the table are more likely to be bumped.

Loose mount? -> Exonerated. Wiggled all relevant optics (except the fixed top periscope mirror on the TMS ISC table, which I overlooked and should be checked later) by touching the barrel of the mirrors using fingers, but after each attempt the beam position didn't change.

Bumping? -> Not fully rejected. I didn't apply strong pressure nor any strong impact to optics, so bumping-strongly theory is still alive.

Drift? -> Not that likely. We have observed during HIFO-Y a huge alignment drift correlated with ambient temperature (triggered by clean room on/off) and nobody knows why this happens. But at that time we were probably talking about the radius of ITM over 4km = 17cm/4km ~ 40urad drift, while this time it is 3mm on the TMS ISC table, so it's on the order of a few mrad. This is a much larger effect than the drift in the past.

Comments related to this report
keita.kawabe@LIGO.ORG - 16:40, Thursday 14 November 2013 (8555)

We're soliciting ideas for failure modes NOT listed above as well as the checks that could/should be done before going ahead to change the TMS ISC table alignment.

alexan.staley@LIGO.ORG - 17:17, Thursday 14 November 2013 (8560)

Here are pictures Stefan and Keita took inside the chamber.

Images attached to this comment
alexan.staley@LIGO.ORG - 17:55, Thursday 14 November 2013 (8562)

I very crudely tested the gain of each QPD segment. I just used the offset in pitch/yaw of PZT2 to move the beam onto each segment. The gain of each segment of QPDA was exactly the same. The gain of each segement of QPDB was within 4% of each other. A dither/demod might be a better test, but at first glance the gain segements look OK to me.

H1 AOS (SUS)
jason.oberling@LIGO.ORG - posted 15:31, Thursday 14 November 2013 - last comment - 13:25, Friday 15 November 2013(8548)
WBSC3 ITMx Alignment
IAS: D. Cook, J. Oberling
SUS: B. Weaver
 
Fine aligned the ITMx pitch this afternoon. 
SUS will run transfer functions to confirm the absence of rubbing.
Comments related to this report
betsy.weaver@LIGO.ORG - 15:50, Thursday 14 November 2013 (8549)

We also aligned the reaction chain - it now sits within the pitch tolerance at ~1.1mRad up, but we expect it to point to ~600mRad down after we take the heavy FC sheet off of the CP-AR surface.

betsy.weaver@LIGO.ORG - 13:25, Friday 15 November 2013 (8579)

Also to note - I closed the Ring Heater around the ITMx.

H1 SUS
arnaud.pele@LIGO.ORG - posted 11:20, Thursday 14 November 2013 - last comment - 15:03, Friday 15 November 2013(8539)
IM trends

The IMs and MCs have been burtrestored to the automatically generated snap file from monday 11/11 at 20:00

Attached are 10 min trends of the IMs osem signals in the euler basis (Long/Pitch/Yaw) during alignment on monday, and today after restoring the snapfile.

picture 1 : Monday 11/11 from 19:50 to 20:00 PT

picture 2 : Today 11/14 from 10:20 to 10:30 PT

No major shift is seen when comparing both trends

Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 06:13, Friday 15 November 2013 (8569)IOO

I've looked at the plots, and there is a huge shift of IM1, and shifts that are large on IM2 and IM4. The fact that I changed IM3 on Monday but it's not showing a change is troublesome.

IM1

Delta 800 pitch

Delta 50 yaw

 

IM2

Delta 115 pitch

Delta 10 yaw

 

IM3

Delta 0 pitch

Delta 0 yaw

 

IM4

Delta 70 pitch

Delta 0 yaw

 

The good alignment time is 5:09PST 11/11, or 1:09UTC 11/12.

To really be confident about your alignment now vs the alignment on Monday, you'll need to trend the alignment slider values, the alignment drive values, and the OSEM readings for 1:05-1:10UTC 11/12, and use that to compare the current IM positions.

arnaud.pele@LIGO.ORG - 15:02, Friday 15 November 2013 (8575)

[Cheryl Arnaud]

After talking with Cheryl, I attached, a more accurate comparison between two dates : monday 11/11 from 5pm to 6pm during good alignment and thursday during the night (11/15) from midnight to 1am (quieter environment) after the ISS work of thursday, with the restored alignment from monday.

screenshot 1 : position signals in um/urad in the euler basis monday

screenshot 2 : position signals in um/urad in the euler basis thursday night

screenshot 3 : alignment sliders values monday + volt monitor of 1 osem to prove signal is going through the actuation chain

screenshot 4 : alignment sliders values thursday night + volt monitor of 1 osem to prove signal is going through the actuation chain

We should worry if we were seeing a shif of the order of a mrad, which is far from being the case here.

Images attached to this comment
cheryl.vorvick@LIGO.ORG - 15:03, Friday 15 November 2013 (8582)IOO

IM1

delta of 80 (not 800) in pitch

H1 SYS (AOS, COC, INS, SEI, SUS, SYS)
jeffrey.kissel@LIGO.ORG - posted 11:15, Thursday 14 November 2013 - last comment - 13:26, Friday 15 November 2013(8538)
Pictures of BSC3 / ITMX from 2013-11-13
J. Kissel, A. Pele

Though Arnaud had posted a few of the pictures from our B&K hammering session of ITMX in BSC3 (see LHO aLOG 8497), I post the rest here because I got more pictures that are not necessarily B&K related. I attach four .pdf albums, captioned below; along with a few of the best publicity photos attached in raw form.

2013-11-13_BSC3Cabling.pdf
-  Nothing to be alarmed by here, but I noticed that tons of cabling were draped from ST0 of ISI-ITMX to their respective feedthroughs in rather hap-hazard ways, and I was worry about potential shorting of isolation between the suspended payload of HEPI and the Chamber. I mentioned this to Jim, and he quickly assured me that the cables are still in a transient state, and will most certainly be cleaned up before the chamber is closed up. I merely post for posterity, so we (i.e. not just folks in SEI) remember what *not* to do.

2013-11-13_BnKHammering.pdf
- Just a few more pictures from the B&K hammering session, indicating where I was hitting and a few action shots. As I said, Arnaud has posted most of these already in LHO aLOG 8497.

2013-11-13_ITMXPublicityPhotos.pdf
- It's always good to get some shots that can be later used for posters and talks. Here's a fashion show of H1 SUS ITMX.

2013-11-13_IXArmCavityBaffle.pdf
- A couple of things to note here:
(1) The first two pages show just how incredibly close the ACB is to the QUAD structure as a result of the move decreed by IAS. In page two I'm trying to hold up a 3/16ths allen key up for perspective, but it didn't work out so well. I would estimate the gap at-closest-approach is no more that 5 [mm]. It just gives me the willies. Especially since I gave the ACB a few milli-Jeffs of calibrated excitation, and it started waggling with reasonably high Q at ~5-10 [Hz]. Is the fundamental resonance of this suspension really that stiff / high-in-frequency? Hurumph.
(2) This is the first time I've seen the suspension system up-close and personally, so I wanted to get some good shots of it. Very interesting design...
(3) There's still some tooling lying around on the baffle itself. We should make sure to grab these before chamber close-out.
Images attached to this report
Non-image files attached to this report
Comments related to this report
thomas.vo@LIGO.ORG - 16:05, Thursday 14 November 2013 (8552)
The tooling on the baffle is meant to be there to remind me to tighten a loose cable clamp bolt when I go in there to finish up cable routing and photodiode switch out (we had a bad one).  The entire baffle will be swept for tools, loose hardware, and particulate as the last thing we do before signing off the chamber close-out.
betsy.weaver@LIGO.ORG - 13:26, Friday 15 November 2013 (8580)

Travis is cleaned up the cabling today.

H1 SUS
betsy.weaver@LIGO.ORG - posted 12:29, Wednesday 13 November 2013 - last comment - 13:33, Friday 15 November 2013(8503)
ETMx pitch final alignment - and FC issue

This morning Travis, Jason and I made the ~last pitch alignment of the ETMx.  We also pulled the FC from the inside of the 2 East viewports and the ETMx CP-AR.  However, when we pulled the FC off of the CP-AR, the thin central portion of the sheet left segments of a ring around the center of the optic.  Par for the course.  And, of course, I could not get any good pictures of the feature so I'll attach a sketch shortly.  I'll get with COC to see what I should do - note, I cannot get the spray cone on to resheet the First COntact and start over, so either we'll need to live with these remnants, or I'll have to get crafty with a smaller cone.

 

But, back to the alignment - we aligned the ETMx to an offset pitch pointing such that when we pull the First Contact sheet from the HR surface, the optic bounces up to point the nominal pitch.  However, this does not help TMS with their alignment now.  After consult with IAS/TMS we decided to put the offset pitch onto the bias slider of the ETMx.  We have the range according to the uRad-calibrated bias slider, however Jason is going to go map it out and confirm the calibration of the slider with his optical equipment (still set up).  This should not take long, and he will leave the offset bias enabled for TMS to start their alignment asap.

Comments related to this report
betsy.weaver@LIGO.ORG - 13:46, Wednesday 13 November 2013 (8505)

Attached is my sketch of the CP-AR FC remnants/wisps left after I pulled the full sheet today.

Images attached to this comment
betsy.weaver@LIGO.ORG - 13:51, Wednesday 13 November 2013 (8506)

Note, these features are very small and kinda difficult to see, so they might be survivable...

jason.oberling@LIGO.ORG - 13:58, Wednesday 13 November 2013 (8507)AOS

ETMx pitch after this morning's adjustments:

  • Pitch: 383 µrad down
    • Target Pitch: 360 µrad down (8 µrad optic pitch + 352 µrad FC correction)
    • Error: 23 µrad
    • Tolerance: ±50 µrad
calum.torrie@LIGO.ORG - 08:41, Thursday 14 November 2013 (8529)
With reference to this alog 8503

We first note it is not a CP but an ERM AR side (TMS side).

As a result of it being a ERM AR side (and location) the small amount of first contact should either be left or removed with acetone if you really want too.

Cheers, Calum (with input from GariLynn)
betsy.weaver@LIGO.ORG - 08:56, Thursday 14 November 2013 (8530)

Great!  Sorry about the error in the reference to a CP - indeed, it is of course an ERM!  Thanks!

betsy.weaver@LIGO.ORG - 13:33, Friday 15 November 2013 (8581)

Also to note - at the time of this alignment, I closed the Ring Heater around the ETMx.

Displaying reports 75241-75260 of 83551.Go to page Start 3759 3760 3761 3762 3763 3764 3765 3766 3767 End