A note on Mad City Labs products for ISC persons

MCL PZTs used for ALS injection alignment on the ISCTEX|Y have strange convention.

X=PIT (rotation around X or horizontal axis)

Y=YAW (rotation around Y or vertical axis)

Also the gain of the internal feedback is set to the highest, which seems to cause a large oscillation for 2" optic. You need to open the chassis and move the jumper to reduce the bandwidth.

See https://dcc.ligo.org/e1300870.

H1 SEI
hugh.radkins@LIGO.ORG - posted 10:04, Thursday 14 November 2013 (8534)
WBSC3-ITMx HEPI Inductive Position Sensor Readings & IAS

Attached is a 4 day trend plot with the IPS readings at BSC3 during the final alignment on Monday 11 November.  Here are the numbers:

Pier 1-NW 2-SW 3-SE 4-NE
Horz 6900 -500 -6500 0
Vert 100 2100 1300 5600

If you look at the plot, you'll see that the readings have drifted since alignment from the table values but things just look to be settling and no shift is larger than 0.001" (655cts/mil).  The apparantly large shift (it really isn' that large) on the verticals ~1/2+ way through the plot is maybe the corner cube removal.

Images attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 09:33, Thursday 14 November 2013 (8533)
WHAM6 HEPI Actuators Locked

HEPI Actuators were locked this morning for the door removal.   Locked position is within 0.001" of unlocked values.

H1 SUS
mark.barton@LIGO.ORG - posted 09:08, Thursday 14 November 2013 - last comment - 11:05, Thursday 14 November 2013(8532)
OMC OL values

I logged the OMC OLs for Jeff B:

prettyOSEMgains('H1','OMC')

M1T1 20997 1.429 -10499
M1T2 21195 1.415 -10598
M1T3 23620 1.270 -11810
M1LF 22733 1.320 -11366
M1RT 21724 1.381 -10862
M1SD 22193 1.352 -11096
 

Comments related to this report
mark.barton@LIGO.ORG - 11:05, Thursday 14 November 2013 (8537)

I entered the OSEMINF offset and gain values, entered the correct magnet signs in COILOUTF and did a new safe.snap. I had to do this manually because the Matlab script doesn't cope with the fact that the autoBurt.req has three bad lines due to a bug in RTCDS 2.8 leading to the folllowing errors:

H1:SUS-OMC_DACKILL_PANIC.HSV ... not connected so no ca_array_get_callback()
H1:SUS-OMC_DACKILL_PANIC.LSV ... not connected so no ca_array_get_callback()
H1:SUS-OMC_DACKILL_PANIC.LOW ... not connected so no ca_array_get_callback()
 

H1 SUS
betsy.weaver@LIGO.ORG - posted 09:05, Thursday 14 November 2013 - last comment - 17:08, Thursday 14 November 2013(8531)
PUM-ETM06

Gerardo and Gerardo Jr. are bonding ears to PUM-ETM06.  As of yesterday 1 ear had been bonded.

Comments related to this report
gerardo.moreno@LIGO.ORG - 17:08, Thursday 14 November 2013 (8557)COC

Second ear bonded today, both ears look good and are within tolerance.  PUMETM06 will go into a cake tin tomorrow.

H1 AOS
keita.kawabe@LIGO.ORG - posted 22:00, Wednesday 13 November 2013 - last comment - 10:41, Thursday 14 November 2013(8525)
TMSX alignment (Alexa, Sheila, Stefan, Keita)

Many things didn't make sense at first (see Sheila's alog) but anyway we injected the green beam into the chamber, adjusted the beam position on the first steering mirror, roughly aligned that mirror so the beam hits both of green QPDs, and started using ISCT mirrors to further align the beam to TMSX.

The green beam is already hitting the ETMX, the return beam is coming back to the secondary mirror but is not making it to the TMS ISC table yet.

Tomorrow, we'll continue with in-chamber alignment.

Comments related to this report
keita.kawabe@LIGO.ORG - 22:02, Wednesday 13 November 2013 (8526)

SUS person: Please do the ETM TF measurement tonight (13/Nov) if you can.

arnaud.pele@LIGO.ORG - 10:41, Thursday 14 November 2013 (8536)

Measurement of M0/R0 TF is done, and results are pending.

H1 ISC (ISC)
sheila.dwyer@LIGO.ORG - posted 21:09, Wednesday 13 November 2013 - last comment - 22:52, Wednesday 13 November 2013(8523)
pitch and yaw swapped on ISCEX PZT controllers

The pull list for end X has a lot of ?s on it, it was not clear what should be connected to what on the PZT controllers. When we first tried turning on the servos turning on the pitch servos would cause the spots to move away in yaw and vice versa, so we swapped the cables for the input to the MCL PZT controllers from X to Y.  After that the pitch servos cause the beam to drift of in pitch, and yaw in yaw.  Then Chris switched the sign of QPD B in pitch and swapped PZT1 and PZT 2 in yaw.  Now the servos seem to be working.  Clearly we need to measure the matrices in the morning.  

 

Comments related to this report
alexan.staley@LIGO.ORG - 21:39, Wednesday 13 November 2013 (8524)

(Alexa, Stefan)

We also saw that the PZT 2 (top controller, 2inch mirror) sensor was oscillating. This was temporarily fixed by placing a glove over the PZT to dampen the oscillations. We need to revisit this. 

stefan.ballmer@LIGO.ORG - 22:52, Wednesday 13 November 2013 (8527)ISC
Some other things we noticed:

- The PZT drive cable at the anti-imaging chassis was connected to the wrong connector - moving it to the design location brought the signals back to life.
- The QPD read-back cable was not connected to the ADC. The reason for that was that the back plate of the anti-aliasing chassis is labeled incorrectly as going to the DAC (it's an anti-image back plate). We should fix that at least with a label maker to avoid future confusion.
- we were wondering whether the PZT oscillation could be related to local feed-back from the PZT read back in the driver.
H1 TCS (TCS)
thomas.vo@LIGO.ORG - posted 19:49, Wednesday 13 November 2013 - last comment - 10:28, Monday 18 November 2013(8522)
TCS ITMX In-Vacuum Mirror Alignment
Alastair H. Greg G. Robert S. Thomas V.

We were able to complete the alignment of this set of mirrors tonight. One of the 10-24 vented SHCS on the back of the SM2 mirror in BSC2 got bound up and broke at the head but we decided to move forward with the installation and were able to get the mirror secured.  Although all the bolts are tightened down to their capacity on both mirrors, the alignment is still vulnerable to being bumped.
Comments related to this report
mindy.jacobson@LIGO.ORG - 10:28, Monday 18 November 2013 (8603)
The location of the broken and the loose bolts are identified in the attached sheet (2) of the assembly drawing
Non-image files attached to this comment
H1 SUS
arnaud.pele@LIGO.ORG - posted 19:13, Wednesday 13 November 2013 (8517)
b&k ITMX (2)

[Jim W. Travis S. Arnaud P.]

Today, and following yesterday's results we went in BSC3 chamber to take a new set of b&k measurements, and did a series of tests described below :

Test1 : X&Y hit ISI locked

Test2 : X&Y hit ISI locked with dog clamps tigthened

Test 3 : X&Y hit ISI unlocked with dog clamps tightened

The attached pdf is showing good and consistent results in both X and Y directions, for the 3 tests. See pictures for axis.

Several things to notice and conclude :

-The difference between ISI locked/unlocked seems only to affect the anti-resonnance at around 30Hz. Meaning, there's no need to take b&k measurement in chamber, but test stand is sufficient (at least for the quads/bs)

-Tightening the dog clamps didn't change the response above 30Hz

- None of the results from yesterday were reproducable

 

Results and scripts were commited under the svn

Images attached to this report
Non-image files attached to this report
H1 IOO
joseph.gleason@LIGO.ORG - posted 18:58, Wednesday 13 November 2013 (8520)
PR2 Scraper baffle modification complete. New position interferes with table mass.
I've replaced the "Z" plate of the PR2 scraper baffle with the reworked version. This went very smoothly and I was able to do it without removing the assembly from the chamber. The new installation cookie cutter looks like it will work well and not interfere with any dog clamps however there is a table mass in the way of the correct baffle position. This mass seems to be in a different place than the one at LLO that should not interfere.
A few notes for the repeat job at LLO:
Tools required; 1/8, 9/64, 3/16 Allen keys
(It is helpful if the 1/8 key is cut down on the short end but not required)
-It is not necessary to completely disassemble the baffle assembly. Only the top side needs to be removed, however it is helpful to loosen all screws that don't need removal.
-After removing the old plate set it down on the HAM table in the correct orientation to remind yourself how the new one goes in.
-Leave all screws loose until the assembly is completed and then tighten.
H1 SUS
arnaud.pele@LIGO.ORG - posted 18:35, Wednesday 13 November 2013 (8519)
Note for people working on TMSX

While looking at TMSX medm screen, I realized that huge AC values were sent to the dac due to damping.

It seems like the damping was not in its right state because the input osem calibration filters were not engaged.

The picture below describes what filters to engage for the damping to be working : There's a "to_um" to engage at the osem bank, and a "from_um" at the damping bank to compensate for the first one. It won't work if only one of them is engaged.

Images attached to this report
H1 ISC (ISC)
rich.abbott@LIGO.ORG - posted 18:25, Wednesday 13 November 2013 - last comment - 08:16, Thursday 14 November 2013(8518)
RF Distribution Levels in ISC R3
Measured and adjusted the RF power levels associated with the LO drive to the ASAIRA and ASAIRB demodulators (18, 45, 90 MHz)

45MHz to LSCAIR-A 
Changed pad at input to distribution amp to bring the RF drive level down by 3dB as measured at the demodulator end of the LO cable.  The pad was 2 dB, now it is 5dB.  The measured RF drive at the LO jack on the demodulator was 13.0dBm, and has now been reduced to 10.0dBm

18MHz to LSCAIR-B
Added at 2dB pad to the RF distribution panel such that the measured LO at the demodulator LO input is now 10.0dBM

90MHz to LSCAIR-B
Measured the LO drive at the demodulator LO input and found it to be 10.6dBm.  Decided to leave it at that as it's close enough.
Comments related to this report
alexan.staley@LIGO.ORG - 08:16, Thursday 14 November 2013 (8528)

The signals from the RF patch panels to the distribution amplifier were also attenuated:

  • 9 MHz: from 12.8dBm to 10dBm
  • 35 MHz: from 11.9dBm to 10dBm
  • 45 MHz: 11.9dBm to 10dBm
H1 SUS (CDS, IOO)
jeffrey.kissel@LIGO.ORG - posted 16:18, Wednesday 13 November 2013 - last comment - 19:35, Wednesday 13 November 2013(8512)
HAUX Model Problem Fixed by reverting to svn
J. Kissel, D. Barker, R. Bork, A. Pele

I had identified the problem (not aLOGged, appeared yesterday afternoon after the RCG upgrade) with the HAUX models early this morning to be a few, expected unconnected and cross-wired parts. This was because Dave had forgotten that I'd advertised the HAUX to be under-construction, and in his sweeping effort to recompile all models yesterday, accidentally compiled and installed this under-construction, known-to-be broken model. Honest mistake.

I patched up the under-construction model to get it working enough for basic operation early this morning, but then the temporarily-fixed model didn't compile because of RCG issues with bus selectors and creators. Rolf's currently hard at work on it, but in order to make progress with the installation of PSL ISS Outer Loop PD, we've just reverted to the known working svn copy of the model, which compiles just fine with Matlab 2012b, and RCG 2.8 (i.e. all the new stuff).

The svn copy of the model has been compiled, installed, restarted, and restored, and damps nicely as expected. The alignment offsets have been restored to whatever was in the safe.snap,
IM1 P   2330
    Y   -170
IM2 P   -1880
    Y   -300
IM3 P   2850
    Y   300
IM4 P   -2420
    Y   -980

Arnaud's gunna grab some trend data to compare against what alignment offsets were established earlier in the week, to see if they're different; he'll post a comment shortly.
Comments related to this report
arnaud.pele@LIGO.ORG - 19:35, Wednesday 13 November 2013 (8521)

Trend of IM1 IM2 IM3 IM4 from sunday night (10pm) until now are attached below. There was a shift on Monday afternoon that came back at around midnight. labelled time in attached picture is PT

Images attached to this comment
H1 SUS
betsy.weaver@LIGO.ORG - posted 12:29, Wednesday 13 November 2013 - last comment - 13:33, Friday 15 November 2013(8503)
ETMx pitch final alignment - and FC issue

This morning Travis, Jason and I made the ~last pitch alignment of the ETMx.  We also pulled the FC from the inside of the 2 East viewports and the ETMx CP-AR.  However, when we pulled the FC off of the CP-AR, the thin central portion of the sheet left segments of a ring around the center of the optic.  Par for the course.  And, of course, I could not get any good pictures of the feature so I'll attach a sketch shortly.  I'll get with COC to see what I should do - note, I cannot get the spray cone on to resheet the First COntact and start over, so either we'll need to live with these remnants, or I'll have to get crafty with a smaller cone.

 

But, back to the alignment - we aligned the ETMx to an offset pitch pointing such that when we pull the First Contact sheet from the HR surface, the optic bounces up to point the nominal pitch.  However, this does not help TMS with their alignment now.  After consult with IAS/TMS we decided to put the offset pitch onto the bias slider of the ETMx.  We have the range according to the uRad-calibrated bias slider, however Jason is going to go map it out and confirm the calibration of the slider with his optical equipment (still set up).  This should not take long, and he will leave the offset bias enabled for TMS to start their alignment asap.

Comments related to this report
betsy.weaver@LIGO.ORG - 13:46, Wednesday 13 November 2013 (8505)

Attached is my sketch of the CP-AR FC remnants/wisps left after I pulled the full sheet today.

Images attached to this comment
betsy.weaver@LIGO.ORG - 13:51, Wednesday 13 November 2013 (8506)

Note, these features are very small and kinda difficult to see, so they might be survivable...

jason.oberling@LIGO.ORG - 13:58, Wednesday 13 November 2013 (8507)AOS

ETMx pitch after this morning's adjustments:

  • Pitch: 383 µrad down
    • Target Pitch: 360 µrad down (8 µrad optic pitch + 352 µrad FC correction)
    • Error: 23 µrad
    • Tolerance: ±50 µrad
calum.torrie@LIGO.ORG - 08:41, Thursday 14 November 2013 (8529)
With reference to this alog 8503

We first note it is not a CP but an ERM AR side (TMS side).

As a result of it being a ERM AR side (and location) the small amount of first contact should either be left or removed with acetone if you really want too.

Cheers, Calum (with input from GariLynn)
betsy.weaver@LIGO.ORG - 08:56, Thursday 14 November 2013 (8530)

Great!  Sorry about the error in the reference to a CP - indeed, it is of course an ERM!  Thanks!

betsy.weaver@LIGO.ORG - 13:33, Friday 15 November 2013 (8581)

Also to note - at the time of this alignment, I closed the Ring Heater around the ETMx.