psl down,h1ecatx1 restarted, opsws3 and 5 remina crashing

This morning I was unable to use tortise svn to do an svn update on h1ecatx1, jonathan managed to do one using the command line but something is wrong.

Now PLC2 on that machine is giving the message "choose run time system".  I'm not sure why this happened.  I tried stopping the plcs and shut down the OPC powershell window, but when I reran the install scripts I got the same choose run time system message, after which the plc does not run.  So now I am restarting the machine.

I was also trying to use remina on opsws5 to log in to h1ecatx1, now opsws5 is crashed.  Also, earlier today remina crashed on opsws3, and I was not able to use it again on that machine. 

Also, the PSL shut down about an hour ago. 

Comments related to this report
sheila.dwyer@LIGO.ORG - 19:30, Monday 04 November 2013 (8380)

After restarting this, the PLCs came up running again, but powershell for epics communication has the same error as we had 2 weeks ago, saying target machine not found.  This was due to a bad tpy file last time, but I am not sure how to fix it.

james.batch@LIGO.ORG - 12:29, Tuesday 05 November 2013 (8383)
Only opsws4 can reliably run remina.  This is due to video driver problems.  Currently there is a tradeoff, With one video driver you can have lots of medm screens up at the same time, but you can't view digital video or use remina.  With the other video driver, you can view digital video or use remina, but trying to view lots of medm screens leads to slow response.  Opsws4 is set up to allow remina to be used, the other computers are set up to allow multiple medm screens to be viewed.
H1 SUS
arnaud.pele@LIGO.ORG - posted 19:04, Monday 04 November 2013 (8378)
SRM new round of TF

Started a round of TFs for SRM at gps = 1067655775. Measurement will take ~8h to complete.

H1 SUS
arnaud.pele@LIGO.ORG - posted 19:00, Monday 04 November 2013 (8377)
TMSX damping

Keita asked me this morning to take a look at TMSX damping. I am not sure if it is because it is moving too much, or if it was just to make sure it's working.

In any case, damping looks to be functionning fine.


Attached are some results comparing TMS motion damping on vs damping off in each DOF with the ISI floating (no active control). The first picture shows the time series and the second one the spectra.

Qs are reduced by a factor of (roughly the order of) 100 for the first modes of each dof. The last picture shows the filters engaged and the gains (for future reference)

Images attached to this report
H1 IOO
joseph.gleason@LIGO.ORG - posted 17:49, Monday 04 November 2013 (8376)
PSL main beam power reduced to < 300mW for HAM2 work
Joe Gleason, Volker Quetschke

We've reduced the main beam power measured at the bottom periscope mirror to approximately 260mW using the main (second) power control stage. We noticed that the PMC locking was unstable when we entered the PSL and were not able to remedy the issue. The throughput was approximately 80% according to the reflected power. The transmitted power looks to be uncalibrated at the moment and shows only about 1/10th the actual output on the PSL_PMC MEDM screen. Should the throughput change to the usual maximum we will still be under the 300 mW max required for the HAM2 work.
H1 SUS
betsy.weaver@LIGO.ORG - posted 15:48, Monday 04 November 2013 (8375)
ITMx QUAD suspension pushed on ISI table ~6mm +X direction

Travis, Betsy

Today, we attached the QUAD pusher and weight-off-loading mover assemblies on the ITMx QUAD and it's ISI.  Attempting to maintain the yaw and Y-direction alignment, we pushed the suspension structure about 6mm.  We then reclamped the QUAD with it's dog clamps and removed the pushers and movers.  Next up:  SEI HEPI Z, and Yaw adjustment, followed by another IAS measurement suite.

H1 INS
jodi.fauver@LIGO.ORG - posted 15:00, Monday 04 November 2013 (8374)
Apollo work for 04 Nov 2013
Some SUS items were moved from X end to Y End TMS Lab in preparation for dome and doors going back on BSC9 (maybe tomorrow). Some items (iLIGO SEI scissor jacks/blue iron, cables) were moved from Y End to Y Mid. 

A little work was done at Y Mid in preparation for receiving four ISI storage containers from LLO this week. 

The iLIGO baffle was removed from the X Arm Spool and preserved clean. Work on cryopump baffle continued.

Three dust barriers were located (two clean) and moved to the High Bay for in-chamber use. One will need the Viton strip re-attached.
H1 SYS (CDS, SYS)
stefan.ballmer@LIGO.ORG - posted 11:28, Monday 04 November 2013 - last comment - 09:14, Wednesday 06 November 2013(8369)
Another look at the EPICS delay test setup
Attached is a plot of the round trip delay times of EPICS PULL (active read) EPICS PUSH (active write) and EPICS PUSH/PULL (active write to 3rd channel, followed by active read from that channel).

PUSH and PUSH/PULL are dominated by a 2Hz update cycle. PULL sees a 8Hz update cycle.

The minimum delay for PUSH is around 110msec, for PULL and PUSH/PULL it is about twice that.

The delay for all three channels is about 10x too slow to be really useful (i.e. for acknowledgment returns shorter than the blink of an eye.)


Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 09:14, Wednesday 06 November 2013 (8396)CDS, SYS
A last snapshot of the EPICS test setup.

Note that the intermediate EPICS server for the Push/Pull line was rebooted. an EPICS error was indeed reported.
I backed out the temporary changes for testing from h1odcmaster and h1ascimc.
Both models were re-compliled and re-installed and restarted without the changes.

Images attached to this comment
LHO VE
kyle.ryan@LIGO.ORG - posted 11:23, Monday 04 November 2013 (8370)
Replaced existing hardware on XBM 6" roughing port gate valve with 8" CFF blank


			
			
H1 AOS (SEI, SUS)
jason.oberling@LIGO.ORG - posted 10:51, Monday 04 November 2013 (8368)
WBSC3 ITMx Alignment

Log from last Friday, 1 Nov 2013.  Took a look at the ITMx after setting up the Brunson optical square from the End-X station.  Position errors and pitch/yaw as of 1 Nov 2013 are:

I took down the IAS equipment Friday afternoon to allow for this morning's cryopump baffle installation.  While that is happening SUS and SEI are making alignment adjustments.  When the cryopump baffle installation is completed I will set the IAS equipment up again and measure the results of the moves.

H1 SUS (SUS)
betsy.weaver@LIGO.ORG - posted 09:47, Monday 04 November 2013 - last comment - 13:11, Monday 04 November 2013(8367)
SRM rebalanced to aid in range of middle stage AOSEMs

Betsy, Travis

On Friday, we rebalanced the SRM suspension adding enough weight to the middle mass to bring it down such that the 2 AOSEMs which were maxed out in Z-position could be aligned.  These AOSEM brackets were poorly designed and we have found that many of the HSTSes at LHO (and likely at LLO, but awaiting their response) are built with the brackets at a range extreme.  So, while the SRM passed TFs the other week, we had to start over with balancing in order to bring these AOSEMs into alignment with a little bit of range adjustment.  Previously, the SRM had been balanced to within tolerance at ~0.75mm high.  Friday, we added enough weight to bring it to ~0.25mm low in order to bring the middle mass down a bit.  Note none of the other 12 OSEMs were out of range, just the 2 top ones on the middle mass.  Because of the rebalancing, Phase 2b TFs need to be run and evaluated again.

Comments related to this report
janeen.romie@LIGO.ORG - 12:24, Monday 04 November 2013 (8371)
Danny, Gary & Matt agree that we have not seen this problem here at LLO on any suspensions. 
Matt has gone over all of the photos he has of the in situ HSTSs and there are none at the extremes. 
Matt & Betsy will talk
janeen.romie@LIGO.ORG - 13:02, Monday 04 November 2013 (8372)
Matt, Betsy Jeff B & Janeen talked. Matt reminded that there were 2 different vendors for the HSTS weldments. It may be that the horizontals of the two different manufacturer's weldments are in different positions relative to the drawing. If, for example, some of the LHO crossbars are further apart than the LLO crossbars, then the range for those middle stage AOSEM brackets would be different. We are in agreement that if the suspensions meet the requirements - TF pass and optic center is in the right position relative to the optics table - then these differences are acceptable. 
janeen.romie@LIGO.ORG - 13:11, Monday 04 November 2013 (8373)
Matt has a couple of photos of HSTSs here at LLO, that show the relatively nominal position of these brackets.
The first photo is the back of LPR2. The second is the back of MC3. The last is the back of MC2. You'll need to zoom in on these photos to see the AOSEM mounting brackets.
Images attached to this comment
H1 SEI
hugh.radkins@LIGO.ORG - posted 09:44, Monday 04 November 2013 (8366)
WBSC3-ITMX HEPI is level1* locked

Maybe not necessary but caution is OK.  I locked the HEPI before ACB is swung back and SUS moves in to push the suspension around.

* Level1 locked is just using the outer vertical & four outer horizontal lock bolts.  The others are extemely difficult to access and for the entire platform, overkill.

H1 ISC (ISC, SUS)
sheila.dwyer@LIGO.ORG - posted 12:47, Sunday 03 November 2013 - last comment - 14:31, Monday 11 November 2013(8364)
Tip tilts for HAM 6 finsihed

Alexa, Keita, Stefan and Sheila-

We have the last optic mounted and balanced in a tip tilt (SN 33) for HAM 6 (OM3).  We had difficulty balancing this the optic in this tip tilt,  even with a short bolt, 2 nuts and a washer on the back side we could not balance it.  Keita brought out SN20 and 25 which are intended for India (and do not have cables attached).  We had a similar problem balancing one of these.  Keita then noticed that there is slop in the four scews that attach the piece that clamps the wire to the rest of the mirror holder (picture attached, these are the 2 bolts on top and the 2 bolts on the bottom of the photo.) The tip tilts we were able to balance had those screws centered in their holes while they were off center in the tip tilts we were unable to balance.  We centered them on the india tip tilt and then we were able to balance it using a dummy optic.  We then did the same thing on the TT that was originally intended to be the H1 spare (SN33).

In the process we used a dummy optic from iLIGO that has a scratch in the center to avoid chipping more real optics.  

We took parts from TT SN9:  the peak nudge  (which was missing from SN33), the small screw that tightens the balancing bolt (we dropped this) and one of the OSEM flags (one flag on SN33 was bent).  

In the end, we have not changed anything for the india tip tilts (SN 20 and 25) except correcting the position of the small bolts, we have 3 balanced and ready for HAM6 (SN2,4, and 33) and one H1 spare (SN9) which is missing parts and needs the wires reclamped.  

On monday I will double check all of the serial nubers written in this alog to make sure they are right.  

Images attached to this report
Comments related to this report
alexan.staley@LIGO.ORG - 14:31, Monday 11 November 2013 (8462)

As mentioned, last time we swapped the UL flag on SN 33 with the UL from SN 09 since the original one was slightly bent. I confirmed that the swapped flags have the same polarity, and is consistent with the previous polarity measurements done in this alog.

H1 TCS
greg.grabeel@LIGO.ORG - posted 15:35, Saturday 02 November 2013 (8363)
Mirror cleaning
Chris S. Joe D. Greg G.

With the help of Joe and Chris the SM1 mirrors (SN 3,4) were cleaned and are air-baking now, they should be done Monday evening. The SM2 mirrors were also completed recently and are wrapped and bagged and ready for install.
Images attached to this report
H1 SYS (SYS)
jeffrey.kissel@LIGO.ORG - posted 21:44, Friday 01 November 2013 - last comment - 13:56, Sunday 03 November 2013(8362)
RTS to RTS link test for IPC, EPIC read, EPICS write and EPICS write-read
(Stefan Ballmer - not Jeff)

I set up a test for diagnosing front end to front end communications via 4 separate routes:
1) IPC
2) EPICS read (pull data)
3) EPICS write (push data)
4) EPICS write and read, via a third epics server (push to 3rd server, pull from 3rd server)

The setup has a counter on H1odcmaster, this is sent via temporary IPC to h1ascimc, and then returned back to h1odcmaster via the 4 routes described above. For IPC and epics read operations I get an error flag, which I am reporting. No such thing is available for an epics write operation.

h1odcmaster is currently running at 32k, h1ascimc is running at 2k.

I calculated the following quantities
- DELAY          : round trip delay in sec
- DELAY mean     : averaged DELAY
- DELAY max:     : largest DELAY observed
- JITTER MAX     : largest time interval between updates
- JITTER MIN     : shortest time interval between updates
- JITTER MAX-MIN : = JITTER MAX - JITTER MIN, the peak-to-peak jitter
- JITTER RMS     : root-mean-square of the time interval between updates

Conclusion for now:
- No errors observed in the ~1h this was running
- No jitter on IPCs
- epics read has a faster update rate (~8Hz) than epics write (~2Hz)
- as a result the delay is shorter for epics read
- the jitter MAX-MIN is about 40msec for EPICS access - the RMS jitter is about 4msec

I turned on recording for all the fast return channels over the weekend.

The modifications to h1ascimc and h1odcmaster will be backed out on Monday.





Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:56, Sunday 03 November 2013 (8365)CDS, SYS
Here is another snapshot after running for 2 days. No qualitative change.
Images attached to this comment
H1 PSL
sheila.dwyer@LIGO.ORG - posted 19:20, Friday 01 November 2013 (8361)
PMC not locked

The ref cav was not locked all day, I didn't get a chance to look at it until just now, but it seems like the problem is actually with the PMC. 

The indicators on the medm screen seem to think that the PMC is locked, but it does not look locked in the camera, and the reflected power is 12.5 W. 

 

H1 INS (INS, SEI)
jim.warner@LIGO.ORG - posted 16:54, Friday 01 November 2013 (8360)
TF running on ETMX ISI, again

TF's running on ETMX ISI. More reps, so this test will take longer. Running on opsws6.