Displaying reports 75541-75560 of 83543.Go to page Start 3774 3775 3776 3777 3778 3779 3780 3781 3782 End
Reports until 11:22, Friday 25 October 2013
H1 SUS
betsy.weaver@LIGO.ORG - posted 11:22, Friday 25 October 2013 (8265)
ITMx cable popped loosish at sat box last night

This morning I noticed that the signals on 1 cable to the ITMx looked funny.  Richard power cycled the AA chassis which didn't work, so I investigated the cabling at the satellite box.  Indeed, the cable I suspected seemed easy to pop off the box, likely causing the glitching we had observed (although .  I reseated it and then screwed in all connectors that were loose on all 5 ITMx sat box.  Phew - that was an easy one.  Currently, the ITMx filter text file is a mess so Arnaud is working on it.

H1 SUS (SEI, SYS)
jeffrey.kissel@LIGO.ORG - posted 11:05, Friday 25 October 2013 (8264)
Testing multiple tags!!
Just checking to see how this awesome new feature works!
Logbook Admin General
jonathan.hanks@LIGO.ORG - posted 10:52, Friday 25 October 2013 (8263)
Test of the logbook email, please ignore
This is a test of the Logbook email.  Please ignore.
LHO General
john.worden@LIGO.ORG - posted 10:42, Friday 25 October 2013 (8262)
Roofing Progress

The LVEA roof has a complete membrane as of yesterday. The crew has started on the next level down and should be onto the office area roof in a week's time.

Next week sheet metal trim should finish up on some of the out buildings.

Photos are the LVEA roof.

Images attached to this report
Logbook Admin General (CDS)
jonathan.hanks@LIGO.ORG - posted 10:31, Friday 25 October 2013 (8261)
Tagged entry support added to the LHO aLOG
When creating a log entry users may now annotate it with optional tags.  The main impact will be in the mail notices.  When work (and log entries) involve multiple subjects and are appropriately tagged notices will go out based on the primary section/task + additional tags.

For example if an entry was primarily about the FMP but had an impact (and was tagged for PSL) on PSL notifications would go out to people subscribed to FMP and PSL.

The plan is to roll it out at LHO today and if everything goes well to update LLO sometime next week.

As an example, this log entry is tagged with CDS.
H1 SUS
keita.kawabe@LIGO.ORG - posted 09:44, Friday 25 October 2013 (8260)
TMS BOSEMs are without kHz lines

Filiberto power cycled the TMSX coil drivers and the kHz lines are gone.

It's not clear if there's any difference between what Filiberto did today and what Aaron did yesterday, but this time it worked.

It looks noisy from 100 to 300Hz which we might have to investigate later.

Images attached to this report
H1 SEI
fabrice.matichard@LIGO.ORG - posted 22:15, Thursday 24 October 2013 - last comment - 22:19, Thursday 24 October 2013(8257)
HAM 2 tilt decoupling
- The data necessary for tilt decoupling has been taken using white noise excitation. Filtering and amplitude parameters have been defined in order to whiten the output signal and increase the SNR. Each transfer function can now be acquired in about 5 to 10 minutes, even during day time and purged air running (versus ~hours with our previous comb parameters).

- The first picture shows the spectra of the input drive, and the corresponding output spectra during this white noise transfer function measurement. The input is the HEPI motion in the X direction driven at the controller error point. The RMS value of the drive is approximately 50 um. The time series show peaks around 150um. The output is the ISI inertial sensor response in the same direction. 

- The second plot shows the transfer function from the HEPI X motion drive to the ISI GS13 response. It also shows the response for the RY drive that is used to decouple as in a feed-forward scheme. The low frequency part of the two transfer functions is dominated by tilt coupling. The ratio of the two transfer functions at very low frequency is calculated and installed in the MEDM matrices to decouple X and RY.

- The third plot shows the tilt coupling before correction, the expected decoupling and the measured decoupling. Results look good. We can start working on sensor correction tomorrow.
Images attached to this report
Comments related to this report
fabrice.matichard@LIGO.ORG - 22:19, Thursday 24 October 2013 (8258)
Side note: the transfer function amplitude below 1 Hz should be closer to 1. We need to check HEPI calibration.
LHO General
patrick.thomas@LIGO.ORG - posted 18:43, Thursday 24 October 2013 (8246)
Ops Summary
Jeff K. recompiling h1susitmy, restarting h1susb123, restarting DAQ
Oscillation on TMSX OSEMs observed, see Keita's alog
Robert S. running magnetic injections on ITMY
09:15 Mitchel R. going into the LVEA to work on the cyropump baffle assembly between the X arm and H2 PSL enclosure
09:21 Gerardo M. joining Mitchel R. to work on the cyropump baffle assembly
09:30 Jim W. and Greg G. dropping down ISI cabling at ITMX
09:36 Jeff K. restarting h1ascimc
09:51 Richard M. and Peter K. going into the LVEA to look at HAM1, HAM2
Betsy W. running transfer functions on ETMX
10:08 Corey G. looking for alpha wipes in the LVEA
10:46 Driver for Praxair delivery to CP1 called notifying he was 15 minutes away
13:07 Mitchel R. heading back to the LVEA to work on the cyropump baffle assembly
13:20 Gerardo M. heading back to the LVEA to work on the cyropump baffle assembly
13:28 Ken working on conduit at end X, was at end Y
13:47 Hugh R. and Jim W. floating BSC3 on HEPI
~14:21 Lost and regained the midX FMCS channels, except for the pump status. Error reported on the FMCS server as well.
14:44 Stefan B. restarting h1odcmaster, h1odcy and h1odcx models
15:47 Hugh R. and Jim W. done at BSC3, Mitchel R. done at cyropump baffle assembly
16:01 DAQ restart
H1 SEI
hugh.radkins@LIGO.ORG - posted 18:16, Thursday 24 October 2013 (8256)
WBSC9 ETMx HEPI Actuator Disconnected, HEPI Unlocked--Ready for IAS

JimW GregG & HughR

We got all the actuators disconnected and reset for reinstallation.  The HEPI is now unlocked and ready for IAS to again tell us where to go.  Given that we pulled the system against the Actuators and have now disconnected them, it isn't surprising that we have rotated CW further.  Based on the Dial Indicators our level is now out of spec by a few 0.1 mm and I predict we will need to move ~350urads CCW.

H1 SEI
hugh.radkins@LIGO.ORG - posted 18:10, Thursday 24 October 2013 (8255)
WBSC3 ITMx Platform is Floating on HEPI

JimW GregG & HughR

We unlocked HEPI and suspended, well, you know, like everything on the HEPI DSCW Springs.  While the horizontal position shifted we did put the verticals back close to where they started.  Then we set up to look at the ISI Optical Table for level.  We were level to +- 0.1mm so we did nothing further there.  The vertical position is low by 1.8mm:

Nominal - GztoLz = position in local level - observed average = position error

D0901148 - T1100187

1661.7mm-2.8 = 1658.9 - 1657.1 = 1.8mm

H1 SUS
keita.kawabe@LIGO.ORG - posted 17:05, Thursday 24 October 2013 (8254)
TMSX OSEM 1727Hz Oscillation

Patrick told me that the TMS BOSEMs looked crazy in the morning, and I passed the information to Richard, who instructed Aaron to do something (power cycle the coil driver? I don't remember the details).

I came back to the control room at 4:30 PM and it's still crazy, showing 1727Hz peak and its harmonics. Looks quite similar to Arnaud's alog about BS BOSEMs (https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=7237).

I'd like to know if Aaron actually did what was suggested.

Images attached to this report
H1 INS
jodi.fauver@LIGO.ORG - posted 16:07, Thursday 24 October 2013 (8253)
Apollo work for 24 Oct 2013
Cable-pulling at Y End was completed. Screens were applied to the X Arm Spool cleanroom in the LVEA. Viewport materials were moved to Y Mid.
LHO VE
kyle.ryan@LIGO.ORG - posted 16:05, Thursday 24 October 2013 (8252)
Closed 10" gate valve on CP8 -> CP1-7 closed as-found
Don't know why or for how long this valve has been open
H1 SUS
travis.sadecki@LIGO.ORG - posted 13:10, Thursday 24 October 2013 (8250)
BSC3 ITMx cabling

For future reference, usually our own.  These are D1000225 extension cables.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 12:14, Thursday 24 October 2013 (8249)
Status of Front End IPC channels

I wrote a python script to summarize the IPC channels defined by the H1.ipc file. The script is userapps/release/cds/h1/scripts/ipc_channel_report.py

total num of Dolphin CS channels  233
total num of Dolphin EX channels   23
total num of Dolphin EY channels   36
total num of RFM0 channels          9
total num of RFM1 channels          9
total num of SHMEM channels        46
Here is its output:
 
total num of Dolphin CS channels  233
total num of Dolphin EX channels   23
total num of Dolphin EY channels   36
total num of RFM0 channels          9
total num of RFM1 channels          9
total num of SHMEM channels        46
 
For the Dolphin channels, I checked to see which ones no longer exist in any H1 models (I grep'ed them in userapps/release/*/h1/models/*mdl). Here is the list of supposedly obsolete channels:
 
H1:ALS-Y_ARM_IPC
H1:ASC-Y_TR_A_PIT_IPC
H1:ASC-Y_TR_A_SUM_IPC
H1:ASC-Y_TR_A_YAW_IPC
H1:ASC-Y_TR_B_PIT_IPC
H1:ASC-Y_TR_B_SUM_IPC
H1:ASC-Y_TR_B_YAW_IPC
H1:ISCEY-SUSETMY_LONG
H1:ISCEY-SUSETMY_PIT
H1:ISCEY-SUSETMY_YAW
H1:ISCEY-SUSTMSY_PIT
H1:ISCEY-SUSTMSY_YAW
H1:LSC-Y_TR_A_IPC
H1:SUS-ITMX_M0_OFFLOAD_RX_IPC
H1:SUS-ITMX_M0_OFFLOAD_RY_IPC
H1:SUS-ITMX_M0_OFFLOAD_RZ_IPC
H1:SUS-ITMX_M0_OFFLOAD_X_IPC
H1:SUS-ITMX_M0_OFFLOAD_Y_IPC
H1:SUS-ITMX_M0_OFFLOAD_Z_IPC
 
We will most probably take the opportunity to rebuild the H1.ipc file from scratch when we upgrade to RCG2.8 to remove obsolete channels.
total num of Dolphin EY channels   36
total num of RFM0 channels          9
total num of RFM1 channels          9
total num of SHMEM channels        46
H1 SUS
betsy.weaver@LIGO.ORG - posted 10:44, Thursday 24 October 2013 - last comment - 09:18, Friday 25 October 2013(8248)
ETMx TFs - NO mechanical rubbing found

(Arn, Kiss, Weavy, Trav)

Unfortunately, the ETMx TFs from last night returned all zero value data.  SO, that needs fixing.

 

However, this morning we manually took all of the 6 DOF TFs on DTT and then hand compared all frequency peaks to the model.  All peaks match the model frequencies to well within a few percent.  SO, the ETMx is currently free and we should proceed with final ETMx HEPI and alignment work.

 

PDF below for all 6 main chain DOFs - cursors show a sample of peaks matching model frequencies.

Non-image files attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 14:25, Thursday 24 October 2013 (8251)

Attached and for reference, are the trend of the calibrated osem signals for a week starting from wednesday oct 16th until thursday oct 24th

M0_DAMP and R0_DAMP are signals calibrated in urad and are representing relative motion between the structure (ISI) and the top mass suspensions. The largest shift over the week is 28 urad for M0 and 23 urad for R0

The other plots are individual osem signals, calibrated in um, representing the relative motion between the reaction and the main chain

The largest shift seen among those plots is at the lower left osem of the uim (L1_OSEMINF_LL) = 115um, which is clearly due to the reaction chain moving relatively to the ISI at the same time on Friday morning (see R0_DAMP). 

 

M0 is the main chain R0 is the reaction chain L1 is the UIM L2 is the PUM, UL LL LR UR are upper left, lower left, lower right, and upper right osems

Non-image files attached to this comment
betsy.weaver@LIGO.ORG - 09:18, Friday 25 October 2013 (8259)

Further notes on Arnauds statement:

"...the lower left osem of the uim (L1_OSEMINF_LL) = 115um, which is clearly due to the reaction chain moving relatively to the ISI..."

could be clarified to

"...the lower left osem of the uim (L1_OSEMINF_LL) = 115um, which is a function of relative motion between the main and reaction chains, and the relative motion between the reaction chain and the ISI, and the possibility of a bumped flag in the process*. "

Specifically noteable is that none of the other 3 OSEMs on this same mass see this size of a motion which means that this signal is not representative of what the mass is actually doing in pitch/yaw.  You cannot have only 1 OSEM signal change by a lot and assume that the mass pitches or yaws.  2-3 OSEMs must show motion that agrees.

*I am surmising that over the course of Thur/Fri HEPI adjustments (which are done 1 corner at a time), the ISI started out level, went unlevel corner by corner, and was restored to level by the time the 4th corner was finished.  Possibly, during this unlevel time between corner 1 and 4 work, the ETMx suspension UIM LL magnet flag was close enough to get knocked around on the BOSEM a bit (likely because it started off not perfectly centered in range).  When the level was restored, the flag snapped back into place, but a slightly different place relative to the LL BOSEM sensor - hence the observed larger 115um shift on just this OSEM.

Remember that this BOSEM senses relative motion between the main and reaction chain since the flag hangs on the main chain and the BOSEM hangs on the reaction chain.  So, as Arnaud has discovered over the last few days of this investigation, quite difficult to use in diagnostics.

H1 SUS
jeffrey.kissel@LIGO.ORG - posted 09:08, Thursday 24 October 2013 (8247)
The 4 R's on H1 SUS QUADs (Yesterday's SUS ECRs E1300578 and E1300261 Progress)
J. Kissel 

I found a few bugs in my modifications to the QUAD models yesterday, once I began to make MEDM fields for all the new variables (which, took so long because of Wednesday's meeting hell) -- and also, after speaking with Kiwamu, Jamie, Jenne, Rana, and Joe Betz, I revamped how the lock-in amplifier part was installed, so that he LSC, ASC, and SUS models are all using identical Simulink parts, if not at least a common MEDM screen. 

This required me to perform the 4 R's:
Re-compile
Re-install
Re-start
and
Re-store (full functionality) [an oft-forgotten step]
all four QUAD models, and restart the Frame Builder (FB) / Data Concentrator (DC) / Data Acquisition System (DAQ) / h1dc0.

Note -- because Robert's been working with ITMY, I 4R'ed h1susetmy, h1susetmx, and h1susitmx and rebooted the DAQ last night before I left for the evening, and then did h1susitmy when Robert gave the OK.
Note -- I'll post pretty pictures and an explanation later, but the revamp of the lock-in part was to go from sending one lock-in oscillator excitation signal to each coil, I'm sending one for pitch and one for yaw.
Displaying reports 75541-75560 of 83543.Go to page Start 3774 3775 3776 3777 3778 3779 3780 3781 3782 End