Due to cooling issues with the MSR, we have left the double doors between the MSR and the hallway opened for this weekend. We have set up a fan which blows the hot air at the rear of the racks out into the hallway. Please do not close the doors of move/obstruct the fan.
I have a script running which emails the MSR room temperature to CDS staff hourly, we will monitor the room over the four day weekend. We have contingency plans set up if we experience any further AC problems.
The TMS-X suspension is mounted on the Bosch frame at End-X and the dummy mass table is suspended. The table is hanging almost level with no adjustments. The Upper Mass blades look to be in their correct position. The Upper Mass is still in stops, so we won't get a good read on how things are really hanging until the Upper Mass is leveled and suspended. This will be one of the first agenda items for next week. No real issues were encountered during the installation of the Upper Structure or with suspending the dummy mass table. The dummy table may be a bit low, but we will not know until we take some measurements. The Genie is parked under the dummy mass table as a safety stop during the long weekend.
After pleny troubleshooting of minor electronics issues, we finally got to the point where we could check out the newly-installed sesnors of HAM6-ISI.
Sensors look fine. We can shoot for installation next week. Spectra are attached.
Note: One of the preamps of the HAM5-ISI ADE boxes (H3) needs fixing. It was used while HAM6's ADE was getting fixed. Symptom was a gain of 1/2 on the spectra of H3
Alignment tweaking on RefCav (Rodruck)
Investigating Dust Monitors at EY (Patrick). EY Dust Monitor-2 is exhibiting odd behavior. The 0.3um readings are several 100,000 counts (while 0.5 is zero).
PCal work in H2psl (Colin, Pablo)
Truck came by to pick up barrel from Flammable Storage Bunker.
TMS Suspension work at EX (Andres, Jeff B)
TMS Telescope work at EX (Keita)
HAM6: GS13 cards swapped, cps interface investigations continue
SURF Student (Emily) will mount accelerometers on Southern doors of HAMs 4&5.
Valved-out YBM MTP @ 1530 -> 2.2 x 10-7 torr*L/sec indicated
I aligned the reference cavity to give ALS more light into their fiber. The TPD voltage increased from 1.1 V to 1.8 V, but I could not get it higher. I believe it used to be around 2 V before the laser shut off this last weekend.
I increased the Common gain to 29 dB to give a UGF of 400 kHz. The light on the RFPD is quite low, around 200 mV, hence the large amount of gain.
Replaced power board D1001975 inside aLIGO HAM ISI Interface Chassis S1201747. Replaced two AD8672ARZ Opamps inside aLIGO HAM ISI Interface Chassis S1201746. Units were cabled with external cables (3 Pin power cables) that feed power to CPS units. Before powering up the CPS units, I used a voltmeter to see the output at the end of the cable and discovered a 7 volt drop on the minus leg. The cables had the third pin tied to shield. This drew excessive current from the power board. The connection to the shield was disconnected from pin three. When the ISI Interface units were powered back on, the power board had one of the rails dead and AD8672ARZ outputs were railing on one of the GS-13 boards.
Further to SUS screen cleanup in alogs 6926 and 6893, I went through the whole $(USERAPPS)/sus/common/medm/quad directory, checking that all linked screens were supplied with a full set of arguments via the argument macro files. I opened each file in gedit and searched for the "args=" lines corresponding to the Arguments fields of the Related Display Data dialog in the MEDM editor. Because nearly all the links were between generic screens but for the same optic I used the following args string:
args="%(read $(USERAPPS)/sus/common/medm/sus$(optic)_overview_macro.txt),USERAPPS=$(USERAPPS),SITE=$(SITE),site=$(site),IFO=$(IFO),ifo=$(ifo)"
Everything worked, so I committed the mods. As time permits I'll do the same for all the other suspension types.
Files updated today:
SUS_CUST_MAIN_MENU.adl - did token cleanup because probably not used. Made H2 and L1 specific calls generic but didn't remove FMx/FMy stuff.
SUS_CUST_QUAD_DACKILL.adl - 2 args lines updated.
SUS_CUST_QUAD_L1_CENTERING.adl - 6 args lines updated.
SUS_CUST_QUAD_L1_WD.adl - 6 args lines updated.
SUS_CUST_QUAD_L2_CENTERING.adl - 6 args lines updated.
SUS_CUST_QUAD_L2_WD.adl - 3 args lines updated.
SUS_CUST_QUAD_L3_OPLEV.adl - 3 args lines updated.
SUS_CUST_QUAD_M0_CENTERING.adl - 8 args lines updated.
SUS_CUST_QUAD_M0_WD.adl - 4 args lines updated.
SUS_CUST_QUAD_R0_WD.adl - 4 args lines updated.
SUS_CUST_QUAD_R0.adl - 14 args lines updated.
SUS_CUST_QUAD_R0_CENTERING.adl - 8 args lines updated.
FIles modified previously (alogs 6926 and 6893):
SUS_CUST_QUAD_OVERVIEW.adl - 64 args lines and 6 name lines updated.
SUS_AUX_QUAD_OVERVIEW.adl - 1 args line and 1 name line updated.
No action required: SUS_CUST_QUAD_IPC.adl, SUS_CUST_QUAD_ADC_MONITOR.adl, SUS_CUST_QUAD_L1_CENTERING_??ZOOM.adl, SUS_CUST_QUAD_L1_COILOUTF.adl, SUS_CUST_QUAD_L1_DAMP.adl, SUS_CUST_QUAD_L1_EUL2OSEM.adl, SUS_CUST_QUAD_L1_DRIVEALIGN.adl, SUS_CUST_QUAD_L1_LOCK.adl, SUS_CUST_QUAD_L1_OSEM2EUL.adl, SUS_CUST_QUAD_L1_OSEMINF.adl, SUS_CUST_QUAD_L1_SENSALIGN.adl, SUS_CUST_QUAD_L1_TEST.adl, SUS_CUST_QUAD_L1_WD_ACT_BANDLIM.adl, SUS_CUST_QUAD_L1_WD_OSEMAC_BANDLIM.adl, SUS_CUST_QUAD_L1_WD_OSEMDC_BANDLIM.adl, SUS_CUST_QUAD_L2_OSEM_ALIGN_??ZOOM.adl, SUS_CUST_QUAD_L2_COILOUTF.adl, SUS_CUST_QUAD_L2_DAMP.adl, SUS_CUST_QUAD_L1_DRIVEALIGN.adl, SUS_CUST_QUAD_L2_EUL2OSEM.adl, SUS_CUST_QUAD_L2_LOCK.adl, SUS_CUST_QUAD_L2_OSEM2EUL.adl, SUS_CUST_QUAD_L2_OSEMINF.adl, SUS_CUST_QUAD_L2_SENSALIGN.adl, SUS_CUST_QUAD_L2_TEST.adl, SUS_CUST_QUAD_L2_WD_ACT_BANDLIM.adl, SUS_CUST_QUAD_L1_WD_OSEMAC_BANDLIM.adl, SUS_CUST_QUAD_L2_WD_OSEMDC_BANDLIM.adl, SUS_CUST_QUAD_L3_DRIVEALIGN.adl, SUS_CUST_QUAD_L3_ESDOUTF.adl, SUS_CUST_QUAD_L3_EUL2ESD.adl, SUS_CUST_QUAD_L3_ISCINF.adl, SUS_CUST_QUAD_L3_LOCK.adl, SUS_CUST_QUAD_L3_OPLEV_MTRX.adl, SUS_CUST_QUAD_L3_OPLEV_SEGS.adl, SUS_CUST_QUAD_L3_TEST.adl, SUS_CUST_QUAD_L3_WD.adl, SUS_CUST_QUAD_M0_CART2EUL.adl, SUS_CUST_QUAD_M0_OSEM_ALIGN_??ZOOM.adl, SUS_CUST_QUAD_M0_COILOUTF.adl, SUS_CUST_QUAD_M0_DAMP.adl, SUS_CUST_QUAD_M0_DCDRIVECAL.adl, SUS_CUST_QUAD_M0_DRIVEALIGN.adl, SUS_CUST_QUAD_M0_EUL2CART.adl, SUS_CUST_QUAD_M0_EUL2OSEM.adl, SUS_CUST_QUAD_M0_ISIINF.adl, SUS_CUST_QUAD_M0_LOCK.adl, SUS_CUST_QUAD_M0_OFFLOAD.adl, SUS_CUST_QUAD_M0_OPTICALIGN.adl, SUS_CUST_QUAD_M0_OSEM2EUL.adl, SUS_CUST_QUAD_M0_OSEMINF.adl, SUS_CUST_QUAD_M0_SENSALIGN.adl, SUS_CUST_QUAD_M0_TEST.adl, SUS_CUST_QUAD_M0_WD_ACT_BANDLIM.adl, SUS_CUST_QUAD_M0_WD_OSEMAC_BANDLIM.adl, SUS_CUST_QUAD_M0_WD_OSEMDC_BANDLIM.adl, SUS_CUST_QUAD_ODC.adl, SUS_CUST_QUAD_R0_OSEM_ALIGN_??ZOOM.adl, SUS_CUST_QUAD_R0_COILOUTF.adl, SUS_CUST_QUAD_R0_DCDRIVECAL.adl, SUS_CUST_QUAD_R0_DAMP.adl, SUS_CUST_QUAD_R0_DRIVEALIGN.adl, SUS_CUST_QUAD_R0_EUL2OSEM.adl, SUS_CUST_QUAD_R0_OPTICALIGN.adl, SUS_CUST_QUAD_R0_OSEM2EUL.adl, SUS_CUST_QUAD_R0_OSEMINF.adl, SUS_CUST_QUAD_R0_SENSALIGN.adl, SUS_CUST_QUAD_R0_TEST.adl, SUS_CUST_QUAD_R0_WD_ACT_BANDLIM.adl, SUS_CUST_QUAD_R0_WD_OSEMAC_BANDLIM.adl, SUS_CUST_QUAD_R0_WD_OSEMDC_BANDLIM.adl
(Andres, Corey, G2, Jeff, Keita)
Upper Mass Suspension
Andres, Jeff, & G2 delivered their Upper Mass Suspension from the Staging Bldg to the EX TMS Lab. It was a tight fit & a shuffle to move the Upper Mass In A Box in the TMS Lab, but we were able to get the Box & Genie positioned under the Bosch Frame. These guys will stay here for a while...
This is because there is an issue with the Blade Springs for the Upper Mass. As it was built the springs are too stiff so it would be hard to have a double pendelum. The solution for this is to re-machine the Angle Bases for the springs (and possibly add a little more weight). The Bases are being machined today (Wed), and should be in an Oven today for baking over the long weekend. Once they are Class-A, the SUS crew will need to swap them out (as a cartridge). This will be done from the "ground" or with the Upper Mass "in the air" clamped to the Bosch Frame.
Telescope
Telescope work is on hold due to ugly mirrors. It has been confirmed by Garilynn at CIT that the 6" Alignment Mirror from LHO is an acceptable mirror. It is currently en route back to LHO (to be received today or Monday). Once we have it, procedures for cleaning this optic are next (tbd offline). Once we have this mirror is cleaned, we can finally begin alignment of these mirrors.
Misc
Corey G. told me that the dust monitor at location 2 in the end Y VEA had started reading exceptionally high counts at .3 microns, but nothing at .5 microns. I went out to take a look, but didn't find anything obvious to account for it. However, this dust monitor was shoved up against the west side of BSC 10 under the beam tube. I moved it farther southwest out into the VEA. The dust monitor at location 1 was near a table next to the electronics racks and I moved it northwest away from the table. I will post pictures of them before and after the moves once I can get them off my phone.
re WPs 4012 & 3884, I brought down & restarted the HEPI Pump Station Pressure maintenance servo yesterday. I am working on an operations manual but for now know that the FWD button inside the Pump Station Control Panel has been hardwired and the Pump will respond as the Medm directs as soon as the Green start button is pressed on the PS Control panel. This is only needed in the case of a Power Outage or Reservoir Level trip.
Anyway, attached are the old (boring) and the new (ever so exciting) control medms. I snapped the EndX screen but EndY looks the same. In general, the operator needs to do nothing with this system. If anything takes the pressure down, the bottom line is to make sure the output of the medm or the Setpoint is zero'd before pushing the green start button on the Pump Station Controller. The output or setpoint is then slowly ramped up(a few psi at a time) by the operator (could/should be automated) to minimize any great shakes of the HEPI/ISI/Optics in chamber.
[Daniel, Stefan, Kiwamu]
For some reason we frequently failed handing the MC control off to the ALS CARM signal this time around. We checked several things to make sure we are back to the configuration we were in the past Friday. Also we aligned the in-vac picomotors to center the infrared beams on their trans QPDs on TMSY.
Also we took a new noise spectrum without the RGA pump running nearby HAM3, the noise spectrum didn't show a big improvement at around 60-70 Hz in which we thought it would improve.
Besides we did the following things :
(Dick G, Daniel S) We added a second frequency difference divider to the rack. For now we just used the output of the DIFF VCO as its input. The division ratio is 10. The attached plot shows the stability of its output as measured by the timing frequency counter. The standard deviation of the distribution is around 2.0 Hz. This is about an order of magnitude better than the single stage measured here. Of course the range has been reduced accordingly and is now roughly +/-100 kHz.
M0 to M0 transfer function measurement in longitudinal (open loop with a gain of 3) on ETMY will start from 2:00 am
J. Kissel Now that (we think) we trust our model to predict the open loop gain transfer function at all frequencies in the current H1 SUS ETMY damping loop configuration with an EPICs gain of 1.0 (see LHO aLOG 6969), I've made a model of how increasing the gain in L and P by 3.0 compares to a gain of 1.0. The gain of 3.0 configuration is what the ISC commissioners run to reduce the spot motion to what they desire (on a camera alone), and some how it is stable. (And yes, they still run with the ISIs only damped, because there is too much low-frequency motion generated by the isolation loops -- also a camera alone "measured" statement). The first attachment are the loop figures of merit. Dashed lines are for a gain of 1.0, and solid lines are a gain of 3.0. We see that the Longitudinal loop should have a upper unity gain phase margin at 3.9 [Hz] of 9 [deg]. This causes a factor of 10 gain peaking at 4 [Hz]. In addition, the (originally) 0.43 [Hz] mode is no longer damped, but distorted to 0.35 [Hz]. In Pitch, although the loop is not as unstable as L, there is still a sharp gain peaking feature at 5.1 [Hz] because the gain margin is so small. Similarly, the lowest (originally) 0.56 [Hz] mode is distorted down to 0.43 [Hz]. We have yet to measure the open loop gain of this exact L/P Gain = 3 configuration, but we were able to get some passive measurements: (1) A comparison of the in loop OSEM sensors, which show similar distortion, and (2) Optical lever spectra of the G = 3 configuration alone to quantify what a "good" level of motion for the cavity locking is. These are the second and third attachments. Confusingly, the L in-loop sensors seem to follow the model behavior, but we don't see similar modification on the middle frequency resonances in Pitch. Also, the optical lever spectra show none of the expected gain peaking.
J. Kissel, A. Pele Given that we were suspicious of the one data point that appeared to show model inaccuracies at the most troublesome 0.43 [Hz] mode of H1 SUS ETMY (see LHO aLOG 6933), we took the time to gather a really high (0.001 [Hz]) resolution, open loop gain transfer function. Comparing this against the model reveals the model matches with measurement very very well. No such double peak is visible. The only remaining discrepancies are the "known" differences -- a little bit off in frequency for the 0.56 [Hz] first pitch mode, and the ~30 [Hz] zero that's from cross coupling of drive to sensor signal in the readout chain (i.e. not representative of the suspended dynamics). For posterity, this was measured with the 2013-05-01 filters, with the extra 0.43 and 1 [Hz] boosts installed by Arnaud, and the overall EPICs gain was set to 1.0. We again see that the phase margin is only 19 [deg]. More to come on installation of a better loop design (i.e. installing the one we already have one in our pocket; see LHO aLOG 6760).
We found ETMY moving about a factor of 10 more (mostly pitch), as seen by the OPLEVs, as well as with beam spot motion. In addition the DAC noise level was increases. Similarly the IST GS13s showed at least two sick channels (higher DAC noise, ratty, 10x higher signal at lower frequencies.) After chasing our tail for about 4h, Dave suggested a remote power cycles. Thus Jim remote power cycled all EY front ends, and we restored them to Friday's burt settings. That fixed the sick channels, and the arm locked right up with no extra motion.
8:46 Pablo D. and Colin S. went into the H2 PSL enclosure to work on PCAL. 9:05 Michael R. went into the H2 PSL enclosure to work on PCAL. 9:27 A truck arrived to pickup pallets. Hugh R. restarted the end Y HEPI pump controller. (WP 4012) Corey G. went to end Y and the end X TMS lab. h1fw1 was taken down to attach a new SSD raid. (see entry 6963) (WP 4011) 10:51 Dick G. went into the LVEA to look at the racks by the H1 PSL and ISCT1 table. 11:12 Thomas V. went into the LVEA to take an inventory of baffles. 11:25 Jim B. went into the LVEA to restart the test stand frontend computers. Dave B. rebooted the OAF and LSC frontend computers to try to fix IPC errors. Dale I. brought a school tour through the control room. Dave B. rebooted the ASC frontend computer to try to fix IPC errors. This unexpectedly created errors on most of the other frontends. 12:34 Dave B. powercycled the RFM switch at end Y to try to fix IPC errors. 1:05 Pablo D. and Colin S. went into the H2 PSL enclosure to work on PCAL. 2:32 Pablo D., Colin S. and Michael R. finished work for the day in the H2 PSL enclosure. 3:40 The commissioners rebooted seiey. 4:58 Jim B. powercycled all the frontend computers at end Y. (see entry 6966) Jeff B. and Andres R. moved the TMS-X upper structure to end X and installed it on the Bosch frame platform. (WP 4013) Richard M. worked on the computer for the access card reader.
An air conditioning unit failed in the MSR, and temperatures were a bit on the warm side so the doors to the MSR have been opened and a fan to circulate air has been started. This is a precaution in case of failure of a second air conditioner which would cause the temperature to rise rapidly.
Great Job Gerardo^2!
Your fast work is really appreciated. Marty
Note, heat was not actually applied to the PUM until ~8pm that evening, with temp achieving ~32 degC (shy of nominal 34degC) around 9-10pm. Soak time set to 6 hours.