Displaying reports 76821-76840 of 83287.Go to page Start 3838 3839 3840 3841 3842 3843 3844 3845 3846 End
Reports until 15:45, Friday 07 June 2013
LHO VE
kyle.ryan@LIGO.ORG - posted 15:45, Friday 07 June 2013 (6672)
Soft-cycled GV18 for viewport work earlier today


			
			
H2 ISC
corey.gray@LIGO.ORG - posted 13:40, Friday 07 June 2013 (6671)
H2 ALS EY Light Pipe Installed (for HIFO)

Installed the 2nd Light Pipe for the H2 ALS EY Table.  This is for the IR path.  (not sure why ALOG rotates attached image)

Images attached to this report
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 11:59, Friday 07 June 2013 (6668)
TMTS Damping Loops Commissioned to Reduce 10 [Hz] Sensor Noise
Similar to the design efforts with the QUAD and BSFM, I designed and implemented a set of "Level 2" damping filters in which 

- All DOFs (except Roll) meet or beat their 10 [Hz] requirements. (Details about Roll below.)
- High-frequency modes are better damped, while still maintaining the majority of the low-frequency damping. The lowest frequency mode in all DOFs (which will have highest displacement amplitude because the ISI's isolation is less) are damped to the same Q, if not even a little less.
- Over all gain is reduced, such that noise between the resonant modes and out-of-band is less.

This new configuration has been appropriately captured and stored in the userapps SVN. Enjoy!

Design Details
--------------
As with all the other suspensions, the top-mass BOSEM sensor noise filtered through the damping loops is the dominate noise source above ~5 [Hz]. Thus the loop designs are primarily focused on modifying each loop such that they collectively meet their displacement noise requirements.

The requirements on the displacement noise are most stringent on Pitch and Yaw of the optical bench for the TMTS, which according to Fig 18 of E1100537 need to hit "a few" x 10^-15 [m/rtHz] at ~10 [Hz]. The remaining degrees of freedom have much more loose requirements BUT because the top-mass blades are misaligned with respect to the Euler control basis like the QUAD, the degrees of freedom are dreadfully cross-coupled at high frequency. (For supporting imagery, check out Mark's mode shape page.)

For example, in order to meet the Pitch requirements at 10 Hz, one must consider the performance of the Longitudinal (obviously), and Transverse. In fact, Transverse is cross-coupled to Pitch, Yaw, and Roll -- the latter so much so that the Transverse residual seismic and top-mass sensor noise dominate the Roll of the optical bench by 1 to 2 orders of magnitude.

The problem with this cross-coupling is that Transverse has the highest frequency resonant mode, at 4.2 Hz. Typically (i.e. in the QUAD and BSFM), this highest Transverse mode couples well to Roll, which in those cases have less stringent requirements. This means you can squash the mode in Roll, sacrificing some sensor noise contribution there, leaving little left to do in Transverse. In the case of the TMTS, the Roll requirements are more stringent AND the 4.2 Hz mode doesn't couple well to Roll, so one can't get enough loop gain to damp it.

So. In order to get *some* damping on this mode, and retain a decent Q on the lower modes, it is difficult-at-best (assuming I stick to the relatively simple, IIR-only, loop design) to roll off the loop gain fast enough to reduce the sensor noise contribution to the 10 [Hz] bench motion. With my design efforts -- involving a 4th order elliptic (similar to the BSFM V design) as well as an extra "phase booster," real, zero/pole pair -- I was able to reduce the Transverse contribution to Pitch and Yaw to below the requirements at 10 [Hz], but Roll is still at ~1e-14 [m/rtHz] at 10 [Hz], but meets the requirement by 16 [Hz].

For a summary comparison between the previous filters and the current filters, check out
dampingfilters_comparison_2013-03-13vs2013-06-06.pdf.

If you're interested in the details of the new design, and plots backing up the above design description and problems, check out the attachment dampingfilters_TMTS_20130606.pdf shows all of the usual design figures of merit. (The old design is shown in dampingfilters_TMTS_20130313.pdf).

A quick, confirmation measurement that the control signals (which, as the model says, should be dominated by sensor noise above 5 [Hz]) have reduced as much as expected in the 10 [Hz] region and above for the most interesting degrees of freedom for the TMTS.

Configuration
-------
For all degrees of freedom,
FMs 1 ("rolloff_*"),2 ("boost_*"),5 ("norm*"), and 10 (ellip_*)
should be engaged. As with the BSFM design, the overall gains of the loop have been folded into the boost_* filter, so that all the EPICs gains are an easy-to-remember -1. Note that this deviates from traditional SUS gains; this is a new era of not-just-velocity-damping-anymore. Hence, the new EPICs gains are:
L = T = V = R = P = Y = -1.


This new configuration has been captured with an updated safe.snap,
${userapps}/release/sus/h1/burtfiles/h1sustmsy_safe.snap
and the new foton file has also been committed here:
${userapps}/release/sus/h1/filterfiles/H1SUSTMSY.txt

Scripts, Functions, and Templates
-------
The scripts used design the loops and generate these plots can be found here:
${SusSVN}/sus/trunk/TMTS/Common/FilterDesign/
design_damping_TMTS_20130606.m
compare_tmts_dampfilter_design.m
The former calls the FOM producing functions
${SusSVN}/sus/trunk/TMTS/Common/FilterDesign/
plottmtsdampingcontroldesign.m
plottmtsactuatornoise.m

The template to compare the control signal ASD lives here:
${SusSVN}/sus/trunk/TMTS/H1/TMSY/SAGM1/Data
2013-06-07_1753_H1SUSTMSY_M1_DAMPOUT_Spectra.xml
Non-image files attached to this report
H1 SEI
hugo.paris@LIGO.ORG - posted 10:59, Friday 07 June 2013 (6670)
HAM1-HEPI - Mechanical Fix

Hugh, Hugo,

 

The Local Static Offset Test* was performed yesterday on HAM1-HEPI. Corner #2 appeared to be responding less than it should have. (see table 1 of attachment)

 

We found a contacting point on HAM1-HEPI's pier #2: The Crossbeam Foot was contacting with the Back Caging Brace. (see figures 1 and 2 of attachment)

 

We loosened the Back Caging Brace, and adjusted its position to leave a cable-tie-wide clearance with the Crossbeam Foot. Other corners have at least this amount of clearance. Corner #3 was a bit tight though. 

 

Those adjustments seems to have solved the problem per the latest Local Static Offset Test taken yesterday evening. (see table 2 of attachment). 

 

We will be doing a Range of Motion Test** as soon as we have a chance to confirm that there is no contact point throughout the whole range of motion of HEPI.

 

 

*: Drive one actuator (5000cts), and record the local readouts to check for unexpected cross-couplings, and potential contact-points or rubbing.

 

**: Drive the HEPI through its full range and make sure that range is not limited.

Non-image files attached to this report
H1 ISC
sheila.dwyer@LIGO.ORG - posted 09:08, Friday 07 June 2013 (6669)
ALS laser noise eater oscillation
THE frequency comparator was not working last night, because the als laser noise eater is oscillating.  This can be seen by a large peak in the beat note signal at 1MHz (-8 dBm on the +13 dB preamp output).  With the noise eater oscillating, the noise eater monitor is at 3.14 V.  

Turning the noise eater off fixes the problem, I am going to leave it off.  

H1 ISC
stefan.ballmer@LIGO.ORG - posted 19:01, Thursday 06 June 2013 - last comment - 19:04, Thursday 06 June 2013(6664)
RED FRINGES!
(Kiwamu, Chris, Stefan)

Morning:
========

Created the H1IFO_ALIGN medm screen and installed BS Face camera (with Richard)

Afternoon:
==========

First we re-established the IM4 trans reference that Keita established on May 22 (alog entry 6472). This was done my locking the IMC, moving the MC3 pitch slowly while input beam and MC were following, until we hit IM4 TRANS again. We then used the IMC WFS relief script (/opt/rtcds/userapps/release/ioo/h1/scripts/imc/mcwfsrelieve) to park the mode cleaner and input beam in this new orientation. (Note: this reliefs the offsets into the actuator offset fields, H1:IMC-MC1_PIT_OUTMON etc., NOT the MC alignment sliders (we should fix that tomorrow, see below for the current offsets)

Next, after thinking way too hard on how to proceed, we moved one slider (PR3 yaw, H1:SUS-PR3_M1_OPTICALIGN_Y_OFFSET) and saw the beam on the BS cage. Centering it roughly on the BS made it visible on the ITM cage. 

The beam was moving too much, so we repeated yesterday's trick: increase the M0 damping gains... it worked again and quieted the beam motion down. (The old and new gains are below.)

With that we pointed the beam roughly on the middle of the ITM, and... saw fringes on both monitor and transmitted QPD. Since up to that point we had only moved one slider (H1:SUS-PR3_M1_OPTICALIGN_Y_OFFSET), nobody actually believed what we saw. But after misaligning the green beam the fringes were still there, and only went away when we moved the red beam...

Set up the anti-whitening filters for the transmission monitor at the end.

Next we wanted to go look for the green beam at ISCT1, but unfortunately the PLL loop broke (see Sheila's log). So that's for tomorrow.


Attached images:
===============
1) Alignment settings when we stared
2) Alignment settings after mode cleaner move (!Caution: additional nonzero MCWFS offsets, see below!)
3) Alignment setting when we got fringes (!Caution: additional nonzero MCWFS offsets, see below!)
4) Fringes on the trans mon!


Settings:
=========

Old PR2 and PR3 damping gains:
H1:SUS-PR2_M1_DAMP_L_GAIN = -1.55
H1:SUS-PR2_M1_DAMP_T_GAIN = -2
H1:SUS-PR2_M1_DAMP_V_GAIN = -3
H1:SUS-PR2_M1_DAMP_R_GAIN = -0.2
H1:SUS-PR2_M1_DAMP_P_GAIN = -2
H1:SUS-PR2_M1_DAMP_Y_GAIN = -1
H1:SUS-PR3_M1_DAMP_L_GAIN = -2
H1:SUS-PR3_M1_DAMP_T_GAIN = -5
H1:SUS-PR3_M1_DAMP_V_GAIN = -1
H1:SUS-PR3_M1_DAMP_R_GAIN = -0.02
H1:SUS-PR3_M1_DAMP_P_GAIN = -0.002
H1:SUS-PR3_M1_DAMP_Y_GAIN = -0.02

New PR2 and PR3 damping gains:
H1:SUS-PR2_M1_DAMP_L_GAIN = -15.5
H1:SUS-PR2_M1_DAMP_T_GAIN = -2
H1:SUS-PR2_M1_DAMP_V_GAIN = -3
H1:SUS-PR2_M1_DAMP_R_GAIN = -0.2
H1:SUS-PR2_M1_DAMP_P_GAIN = -2
H1:SUS-PR2_M1_DAMP_Y_GAIN = -1
H1:SUS-PR3_M1_DAMP_L_GAIN = -20
H1:SUS-PR3_M1_DAMP_T_GAIN = -5
H1:SUS-PR3_M1_DAMP_V_GAIN = -1
H1:SUS-PR3_M1_DAMP_R_GAIN = -0.02
H1:SUS-PR3_M1_DAMP_P_GAIN = -0.02
H1:SUS-PR3_M1_DAMP_Y_GAIN = -0.2

MCWFS offsets (those should be moved to the alignment sliders):
H1:IMC-MC1_PIT_OFFSET = 89.06
H1:IMC-MC2_PIT_OFFSET = 21.556
H1:IMC-MC3_PIT_OFFSET = 86.417
H1:IMC-PZT_PIT_OFFSET = 726.65
H1:IMC-MC1_YAW_OFFSET = 68.493
H1:IMC-MC2_YAW_OFFSET = 4.6945
H1:IMC-MC3_YAW_OFFSET = -69.693
H1:IMC-PZT_YAW_OFFSET = 4073.9



Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 19:04, Thursday 06 June 2013 (6665)
Forgot to mention the obvious: Hats off to the initial alignment team!
LHO General
patrick.thomas@LIGO.ORG - posted 18:26, Thursday 06 June 2013 (6663)
plots of dust counst
Attached are plots of dust counts requested from 5 PM June 5 to 5 PM June 6.

Both the dust monitor at location 14 in the LVEA (H2 PSL enclosure) and the dust monitor at location 16 in the LVEA (H1 PSL anteroom) are indicating calibration failures.
Non-image files attached to this report
H1 ISC
daniel.sigg@LIGO.ORG - posted 18:00, Thursday 06 June 2013 (6662)
ISC EY model
Updated the ISC EY model (without rebooting) to 
- remove remaining WFS logic,
- move LSC part into a common library block,
- fixed names of FIBR_SERVO and REFL_SERVO fast channels,
- fixed names in sheet connectors and ports,
- renamed filter module for slow SUS feedback into ALS-Y_ARM.

Also fixed the unicode problem with the DAQ ini files and copied new versions into the release area.
H1 ISC
alexan.staley@LIGO.ORG - posted 16:56, Thursday 06 June 2013 (6661)
ALS laser mode hopping, RF amp concentrator loose connection, PD calibrations
(Sheila, Alexa)

Calibration of DCPD's:

H1:ALS-Y_RELF_B_DC: Power of 0.26mW at 6.39 Volts (gain of 30db)
H1:ALS-Y_REFL_A_DC: Power of 1.22mW at -.190 Volts

There seems to be some loose connections in the concentrator box for the 24.5Mhz and 71Mhz RF Amplifiers at EY. We confirmed that there was 3.6V out of the amplifiers on the PowerOK pin. When we input 3.6V on the PowerOK pin into the concentrator using a breakout, we saw a signal on the tester. However we lose the signal when using a cable from the amplifier to the concentrator. When we sent 3.6V into the concentrator using a cable and a breakout, we saw a signal once, but not in another instance.  


Stefan called about trying to lock the PLL.  At first, the autolocker had a communication error. This behavior happened previously as in  this alog. The error was solved by reactivating the system manager, which required a burt restore. 

After the burt restore we saw evidence of mode hopping of the ALS laser (Note: the crystal temperature was set to -360MHz by the burt restore; we will fix this). Each time we tuned the temperature so that the beat note was near 60MHz, we would see the peak drop. So we believe this was due to mode hopping of the ALS laser, and not the reference cavity losing lock.  The ALS laser settings were at 1.839 Amps, 31.37 C. We started to adjust them but noticed that the reference cavity would drop in and out of lock. So we returned the ALS laser settings to the above values.
LHO VE
kyle.ryan@LIGO.ORG - posted 16:37, Thursday 06 June 2013 (6660)
Helium leak tested (sort of) HAM1-HAM2 annulus volume
Kyle, John 
Plumbed helium into HAM2 annulus pump port via NW40-1/4 swagelok adapter -> Removed O-ring gasket from HAM1 pump port but left NW40 blank in place -> Pressurized annulus volume with helium @ 10 psi (~45 seconds) and confirmed exhaust flow @ HAM1 pump port (NW40 blank "fluttering" as displaced air/helium exited annulus volume -> dialed helium back to < 5 psi for ~90 seconds -> Removed helium connection and purged annulus volume with instrument air 

Note:  Can't ascertain effectiveness of helium getting to "low" portion of septum annulus due to external piping being located at the top of HAM1 and HAM2 septum flanges -> Experience, however, gives me some confidence that a "largish" leak could not go undetected following the above effort. 

Detector baseline reading ~1 x 10-9 torr*L/sec or less during testing -> no response during testing -> no calibration or demonstration of ability to detect helium -> detector behavior typical otherwise
LHO VE
kyle.ryan@LIGO.ORG - posted 16:22, Thursday 06 June 2013 (6659)
Opened GV1


			
			
H1 SUS
arnaud.pele@LIGO.ORG - posted 16:10, Thursday 06 June 2013 - last comment - 08:06, Friday 07 June 2013(6657)
PRM phase 3b transfer functions

In preparation of the acceptance documentation for HSTS suspensions, PRM top mass has been tested for phase 3b after the series of MCs.

The transfer functions are showing good agreement with model and previous measurements.

The attached file is a comparison between model, phase 3a and phase 3b

files and data have been commited on the svn under the following directories :
/ligo/svncommon/SusSVN/sus/trunk/HSTS/Common/${MatlabTools/Data}
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/${Data/Results}

Non-image files attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 07:18, Friday 07 June 2013 (6666)

I kept forgetting to ask this question : what do these "3a" and "3b" mean ?

mark.barton@LIGO.ORG - 08:06, Friday 07 June 2013 (6667)

See G1200070, Ideal Order/Contents of aLIGO Triple SUS Testing / Commissioning, https://dcc.ligo.org/LIGO-G1200070.

1a: Metal build assemblies, in initial assembly area (e.g., LHO staging building)

1b: Metal build fully assembled, in initial assembly area

2a: Metal build chamberside

2b: Glass build chamberside

3a: Glass build in chamber, before pumpdown

3b: Glass build in chamber, after pumpdown

LHO General
thomas.vo@LIGO.ORG - posted 16:09, Thursday 06 June 2013 (6658)
06/06/2013 Ops Summary
Unlocked BSC2 - Hugh

Close GV-1 to leak check - Kyle & John

Install illuminator and camera on BSC2 - Richard M

Align and level X test stand - Doug & Jason

Check laser welder alignment - Doug & Jason

Assemble E-module and spiral staircase - Apollo

Lift BSC CR on crane, leaving suspended overnight - Apollo

Valve in YBM Turbo and leak detector combination to exposed Y-arm - Kyle
H1 INS
jodi.fauver@LIGO.ORG - posted 15:37, Thursday 06 June 2013 (6656)
ETMX Install Prep
The E-module was assembled and married to the spiral staircase: some transitional plates between the E-mod and the work platform will need to be fabricated and installed when convenient. The Tech Cleaners did the first round of cleaning at BSC9. The Test Stand was craned over the beamtube into position near the roll-up door. Modification of the BSC CR legs to accommodate the leg jacks was started: the ceiling of the CR will be suspended on the crane overnight. The remote control for the crane will be at the corner overnight as a LO-TO measure. All but four bolts were removed from the dome: bolts will come out of the door tomorrow.
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 14:47, Thursday 06 June 2013 (6654)
H1 SUS TMSY Top Open Loop TFs -- Model vs. Measured
In preparation for acceptance of H1 SUS TMSY, I've been asked to model its performance. I accepted given that we've got a state-space model and parameter set that's been confirmed by measurement and it's straight-forward to adopt the loop performance figures of merit from the software suite developed for the QUAD and BSFM Level 2 designs. Here I merely show results that confirm the model's accuracy using the current filters before I move forward with the Level 2 filter design.

The new software suite for the TMTS (which will be useful for the OMCS when it comes online soon as well), can be found here:

${SusSVN}/sus/trunk/TMTS/Common/FilterDesign/
design_damping_TMTS_20130313.m (script where overall design is done)
    - plottmtsdampingcontroldesign.m (function that takes in newly designed filters and computes the performance figures of merit)
        - plottmtsactuatornoise.m (sub-function that computes the actuator noise component of the model)
 
In addition, I've added the TMTS requirements (based on Fig 18 of E1100537) to the function

${SusSVN}/sus/trunk/Common/MatlabTools/SUS_reqs.m


I won't bore you with all of the plots that this suite produces since this has only been run on the Level 1 design of the filters, but I will post results of this morning's transfer functions, and a tease of why the TMTS filters need some tweaking. I'll focus on Pitch, since that (with Yaw) are the DOFs with the most stringent requirements for the TMS, and since L and P were the only DOFs I had time to measure.

Three plots:
(1) dampingfilters_TMTS_20130313_loopmeas_P.pdf A comparison between the modeled and measured open loop gain transfer function. It confirms the stability, and we now see the model is only off by the usual known quantities:
- ~50% under in magnitude (mostly likely due to a systematic scale factor error in the model calibration -- no biggie), 
- a tiny fraction in resonant frequencies (due to modeling the "ideal" suspension properties as opposed to the "real" properties)
- some unmodeled time delay-like feature in the phase.

(2) dampingfilters_TMTS_20130313_loopdesign_P.pdf A loop design plot showing all of the useful figures of merit, the open loop gain transfer function (G), the suppresion (1 / (1+G)), and the closed loop gain transfer function (G / (1+G)). Note, I use the standard convention for loop gain with the explicit -1, such that the stability criteria is that lower unity gain crossings must stay away from +180, and upper unity gain crossings must stay away from -180, with no phase wraps in between the first LUGF and the last UUGF.

(3) dampingfilters_TMTS_20130313_totalbudget_P.pdf A noise budget based on the loop design. 

------
For the record, the filters currently in place (and ON) are (using [zeros:poles:gain] notation, and "pair" to represent a complex pair of zeros or poles at frequency of the first argument, and phase of the second. Both arguments are rounded to the nearest integer for brevity)

L FM1 "damp30" [0:30,100:1],             FM5 "from_um" [::43.478], FM10 "ELF10" [pair(16,86),pair(36,56):pair(6,51),pair(10,79):1], G = -20.0
T FM1 "damp30" [0:30,100:1],             FM5 "from_um" [::43.478], FM10 "ELF10" [pair(16,86),pair(36,56):pair(6,51),pair(10,79):1], G = -10.0
V FM1 "damp30" [0,1:0.3,30,100:3.51521], FM5 "from_um" [::43.478], FM10 "ELF10" [pair(16,86),pair(36,56):pair(6,51),pair(10,79):1], G = -20.0
R FM1 "damp30" [0,1:0.3,30,100:3.51521], FM5 "from_um" [::43.478], FM10 "ELF10" [pair(16,86),pair(36,56):pair(6,51),pair(10,79):1], G = -0.05
P FM1 "damp30" [0,1:0.3,30,100:3.51521], FM5 "from_um" [::43.478], FM10 "ELF10" [pair(16,86),pair(36,56):pair(6,51),pair(10,79):1], G = -0.5
Y FM1 "damp30" [0,1:0.3,30,100:3.51521], FM5 "from_um" [::43.478], FM10 "ELF10" [pair(16,86),pair(36,56):pair(6,51),pair(10,79):1], G = -0.1

which is notably different that when I'd spruced up the TMTS, SUS style back in March (see LHO aLOG 5754, and LHO aLOG 5781), when the different Yaw filter in FM2, and any boosts that were found in FM2 were ON. I didn't see any aLOG of this configuration change, so my guess is this was an old configuration that stuck after a reboot (which is surprising because I specifically captured a new safe...)

I've copied the foton file representing this configuration over to the userapps repo, and committed it to rev 4641
208-69-129-56:filterfiles kissel$ svn info H1SUSTMSY.txt 
Path: H1SUSTMSY.txt
Name: H1SUSTMSY.txt
URL: https://redoubt.ligo-wa.caltech.edu/svn/cds_user_apps/trunk/sus/h1/filterfiles/H1SUSTMSY.txt
Repository Root: https://redoubt.ligo-wa.caltech.edu/svn/cds_user_apps
Repository UUID: e3bfa956-ff0e-4416-9af7-00b7a258cde5
Revision: 4650
Node Kind: file
Schedule: normal
Last Changed Author: jeffrey.kissel@LIGO.ORG
Last Changed Rev: 4641
Last Changed Date: 2013-06-06 14:35:30 -0400 (Thu, 06 Jun 2013)
Text Last Updated: 2013-06-06 14:45:31 -0400 (Thu, 06 Jun 2013)
Checksum: e5032b936a0f52fd58cfd2ec15dd771b


------
Also, the data (for L and P only thus far) was taken with the following templates:

2013-06-06_1511_H1SUSTMSY_M1_L_WhiteNoise_OLGTF.xml
2013-06-06_1511_H1SUSTMSY_M1_P_WhiteNoise_OLGTF.xml

which notably improve on the standard SUS white noise DTT excitation: in order to get more coherence at low frequency, I added a zpk([0.5;0.5],[0.05;0.05],100,"n") to the Filter field in the Excitation Tab of the measurement. This adds a factor of 100 gain at low frequency (filtered out by 1 [Hz]) where the coherence is the worst, and we're not plagued with DAC saturations because on the anti-dewhitening filters in the COILOUTF banks (which start adding gain above 1 [Hz]). This way I can jack up the overall gain of the measurement at low frequency where we need it, without saturating the DAC nearly as quickly.
Non-image files attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 14:46, Thursday 06 June 2013 (6655)
WBSC2 (BS) SEI HEPI System Unlocked *** Careful Please ***
This chambers Actuators were moved from Bleed to Run State on Tuesday and the IPS sensors zero'd then as well.  Unlocking them today sees significant motion especially as compared to HAM1 this morning.  At HAM1 the motion on release was 2 mils or less.  Here at BSC2 the vertical moved down (uniformly) 13000 counts or about 20 mils.  The horizontal shift was half or less than the vertical shift with the motion being East with some minor CCW rotation.
H1 IOO
kiwamu.izumi@LIGO.ORG - posted 16:59, Wednesday 05 June 2013 - last comment - 12:53, Thursday 06 June 2013(6643)
IMC WFS loop closed part II

[Chris, Kiwamu]

This is a detailed version of the previous IMC WFS entry (see alog 6633).

 

Actuation issue wasn't really an issue:

 We kept driving the M3 stages (very bottom stage) of MC1 and MC3 to excite the angular motions (alog 6610) but it turned out that this was not the right way. The actuators on M3 are simply not strong enough to excite them with a high signal-to-noise ratio at the wave front sensors. Therefore we need o switch the driving point from the M3 to M1 (very upper stage) to have a big excitation. In fact this is the way the people in Livingston did. After all, exciting M1 gave us a prominent peak in the spectrum of the WFS signals and hence we were able to proceed with the measurement of the sensing matrix.

 

Balancing of the quadrant segment gain:

During adjusting the demod phase of each segment of the WFSs we noticed that they show different signal gain. In order to correct this gain discrepancy among the segments we changed the digital filter gain to make them identical. We excited the longitudinal motion of the IMC by injecting a 6 Hz sinusoidal signal at INPUT2 of the IMC common mode board servo with an amplitude of 80 mVp-p. This resulted in a peak in the spectrum of each quadrant. Then we adjusted IMC-WFS_A(B)_IX_GAIN and IMC-WFS_A(B)_IX_GAIN where X = 1,2,3,4. Here is the resultant gain coefficients. We are not sure why the gains vary by a factor of 5 at most among the segments. This variation can not be explained by the discrepancy in the transfer gain of the demodulation chain.

H1:IMC-WFS_A_I1_GAIN = 1
H1:IMC-WFS_A_Q1_GAIN = 1
H1:IMC-WFS_A_I2_GAIN = 5.33
H1:IMC-WFS_A_Q2_GAIN = 5.33
H1:IMC-WFS_A_I3_GAIN = 4.43
H1:IMC-WFS_A_Q3_GAIN = 4.43
H1:IMC-WFS_A_I4_GAIN = 1.33
H1:IMC-WFS_A_Q4_GAIN = 1.33
H1:IMC-WFS_B_I1_GAIN = 5.75
H1:IMC-WFS_B_Q1_GAIN = 5.75
H1:IMC-WFS_B_I2_GAIN = 1
H1:IMC-WFS_B_Q2_GAIN = 1
H1:IMC-WFS_B_I3_GAIN = 1.07
H1:IMC-WFS_B_Q3_GAIN = 1.07
H1:IMC-WFS_B_I4_GAIN = 5.47
H1:IMC-WFS_B_Q4_GAIN = 5.47

 

Compensation for the geometrical rotation:

As far as we remember there is a periscope in the IMC-REFL path which rotates the x-y relation of the beam, which rotates it by almost 90 degrees. Due to this effect the actual yaw motion happening in the IMC cavity shows up as almost pitch motion and vice versa at the RFFL port. We corrected this effect by manipulating the input matrix (IMC-WFS_A(B)_I_MTRIX) such that the yaw excitation shows up only in pitch basis after the input matrix. This adjustment was done by exciting the M2 stage of MC2 (which somehow we ended up with for some reason when exciting the angular motions) in pitch and yaw at 3 Hz. As a result the coupling between pitch and yaw were improved and separation ratio became approximately a factor of 50 at least which used to be 1 at worst. Here is the resultant matrix elements.


H1:IMC-WFS_A_I_MTRX_1_1 = 0.478812
H1:IMC-WFS_A_I_MTRX_1_2 = -1.33069
H1:IMC-WFS_A_I_MTRX_1_3 = -0.478812
H1:IMC-WFS_A_I_MTRX_1_4 = 1.33069
H1:IMC-WFS_A_I_MTRX_2_1 = 1.33069
H1:IMC-WFS_A_I_MTRX_2_2 = 0.478812
H1:IMC-WFS_A_I_MTRX_2_3 = -1.33069
H1:IMC-WFS_A_I_MTRX_2_4 = -0.478812
H1:IMC-WFS_B_I_MTRX_1_1 = 0.394297
H1:IMC-WFS_B_I_MTRX_1_2 = -1.35813
H1:IMC-WFS_B_I_MTRX_1_3 = -0.394297
H1:IMC-WFS_B_I_MTRX_1_4 = 1.35813
H1:IMC-WFS_B_I_MTRX_2_1 = 1.35813
H1:IMC-WFS_B_I_MTRX_2_2 = 0.394297
H1:IMC-WFS_B_I_MTRX_2_3 = -1.35813
H1:IMC-WFS_B_I_MTRX_2_4 = -0.394297
 

Measurement of the sensing matrix

The measurement of the sensing matrix went very smooth. We excited the M1 stage of the IMC suspensions. We considered two DOFs in pitch (yaw), namely common (differential) MC1-MC3 and MC2. This is the DOF basis that the Livingston people came up with in the IMC WFS commissioning. The excitation was injected to DOF_1(2)_Y(P)_EXC with an amplitude of 10-12 counts at about 3 Hz. To be sure that we are exciting the pure pitch or yaw we looked at the witness channels for the bottom stage and confirmed that we were exciting the right angular motion. Since we didn't have an auto-script to measure the sensing matrix we used diaggui to measure the transfer coefficient from the excitation to the WFSs. After measuring the 2x2 sensing matrix we inverted it and put it to the control input matrix IMC-INMATRIX_P(Y). In diaggui the frequency resolution was set to 0.01 Hz. Here is the resultant input matrix.

H1:IMC-INMATRIX_P_1_1 = 0.64725
H1:IMC-INMATRIX_P_1_2 = -0.35275
H1:IMC-INMATRIX_P_2_1 = -0.159639
H1:IMC-INMATRIX_P_2_2 = 0.840361

H1:IMC-INMATRIX_Y_1_1 = -0.163134
H1:IMC-INMATRIX_Y_1_2 = -0.836866
H1:IMC-INMATRIX_Y_2_1 = 0.529564
H1:IMC-INMATRIX_Y_2_2 = 0.470436


Closing the loops:

The trial of closing the loops were relatively easier compared with what we did to reach this point. We simply started from a small gain of 1e-4 and we fiddled with the sign. Since this was the first time for us to close the loops we enabled only fundamental control filers, namely FM6 (0.06, 0.1) and FM7(0:1) of IMC-DOF_1(2)_P(Y) and disabled the rest of the fancy filters. We aimed an UGF of  a few 10 mHz or so. The gains were adjusted by looking at the time scale of the control against a disturbance. The gains we ended with were :

H1:IMC-DOF_1_P_GAIN = -1e-05
H1:IMC-DOF_2_P_GAIN = -1e-05
H1:IMC-DOF_1_Y_GAIN = -1e-05
H1:IMC-DOF_2_Y_GAIN = -1e-05
 

What are missing ?:

Comments related to this report
christopher.wipf@LIGO.ORG - 12:53, Thursday 06 June 2013 (6653)
The DOF3 (MC2 TRANS centering) loops have been turned on, currently with very low UGF (step response ~minutes).  They worked "out of the box" using the LLO filters, and a bit of tweaking of the DOF3 gains.

Under $USERAPPS_DIR/ioo/h1/scripts/imc there's a new script, mcwfsrelieve, which offloads the DOF1/2/3 outputs onto the downstream filter modules (H1:IMC-MC1_PIT et al).

There's also a rudimentary_autolocker script for the IMC (temporary stopgap until the Guardian is up and running here).

Though we have plenty of optimization left to do, the IMC now has a reproducible baseline configuration, which is its main requirement during HIFO-Y.
Displaying reports 76821-76840 of 83287.Go to page Start 3838 3839 3840 3841 3842 3843 3844 3845 3846 End