Reports until 07:24, Thursday 06 June 2013
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 07:24, Thursday 06 June 2013 - last comment - 11:10, Thursday 06 June 2013(6648)
Taking Transfer Functions on TMSY
Just a heads up, I'll be taking transfer functions remotely on TMSY this morning. HIFO-Y work takes precedent over this, so don't hesitate to call me and tell me to stop!
Comments related to this report
jeffrey.kissel@LIGO.ORG - 11:10, Thursday 06 June 2013 (6651)
I've finished my work for the day. Will pick up again early tomorrow morning unless there are objections from the commissioning crew.
LHO General
patrick.thomas@LIGO.ORG - posted 19:42, Wednesday 05 June 2013 (6647)
plots of dust counts
Attached are plots of dust counts requested from 5 PM June 4 to 5 PM June 5.

Both the dust monitor at location 14 in the LVEA (H2 PSL enclosure) and the dust monitor at location 16 in the LVEA (H1 PSL anteroom) are indicating calibration failures.
Non-image files attached to this report
H1 AOS
stefan.ballmer@LIGO.ORG - posted 18:57, Wednesday 05 June 2013 (6646)
Green lock robust
(Jax, Alexa, Arnaud, Chris, Sheila, Daniel, Stefan)

We implemented the DC relief to ETMX for the ALS lock

- Implemented a IPC link from H1:ASL-Y_ETM_LONG to H1:SUS-ETMY_L3_ISCINF_L_IN1.
- Added dewhitening filter to H1:ALS-Y_REFL_SMON FM1 (Zeros 10Hz, 10Hz; Poles 100Hz, 100Hz).
- Zerod the electronic offsets in the CM board B and slow path (H1:ALS-Y_REFL_SERVO_COMOFS=0.505V, H1:ALS-Y_REFL_SERVO_SLOWOFS=-1.675V, H1:ALS-Y_REFL_SMON_OFFSET=-1645).
- Added 1/f filer in stages (Z:P: 10:1:0, 1:0.1, :1) and gain of -0.03 in H1:ALS-Y_ETM_LONG filter bank.
- SUSETMY is in "distributed feed-back mode". We feed back only to the top mass.
- H1:SUS-ETMY_L3_ISCINF_L and H1:SUS-ETMY_M0_LOCK_L have a flat gain of 1.

We also killed a 1.3Hz oscillation in the light from the fiber by putting a 20dB,Q=3 resonant gain into the H1:IMC-L path. All this, together with another alignment tweak, made for very stable locks: while I am writing this log the arm stays locked for 20min at a time while the relief integrator is ticking away (Tidal?). I set the limiter H1:ALS-Y_ETM_LONG_LIMIT to 10000 cts to prevent kicking the Quad too hard - this eventually breaks the lock. 

Sheila and I quickly took a peak, but there is no green beam coming out at the corner yet. Not too surprising,.. next we need to align the IR beam to hit the ETM cage.

Things to do with low priority:
- Decouple force to pitch (& yaw) at DC - the alignment degrades slightly for O(1e4) counts of M0 length drive. But its likely good enough for the HIFO work.
H1 IOO
kiwamu.izumi@LIGO.ORG - posted 16:59, Wednesday 05 June 2013 - last comment - 12:53, Thursday 06 June 2013(6643)
IMC WFS loop closed part II

[Chris, Kiwamu]

This is a detailed version of the previous IMC WFS entry (see alog 6633).

 

Actuation issue wasn't really an issue:

 We kept driving the M3 stages (very bottom stage) of MC1 and MC3 to excite the angular motions (alog 6610) but it turned out that this was not the right way. The actuators on M3 are simply not strong enough to excite them with a high signal-to-noise ratio at the wave front sensors. Therefore we need o switch the driving point from the M3 to M1 (very upper stage) to have a big excitation. In fact this is the way the people in Livingston did. After all, exciting M1 gave us a prominent peak in the spectrum of the WFS signals and hence we were able to proceed with the measurement of the sensing matrix.

 

Balancing of the quadrant segment gain:

During adjusting the demod phase of each segment of the WFSs we noticed that they show different signal gain. In order to correct this gain discrepancy among the segments we changed the digital filter gain to make them identical. We excited the longitudinal motion of the IMC by injecting a 6 Hz sinusoidal signal at INPUT2 of the IMC common mode board servo with an amplitude of 80 mVp-p. This resulted in a peak in the spectrum of each quadrant. Then we adjusted IMC-WFS_A(B)_IX_GAIN and IMC-WFS_A(B)_IX_GAIN where X = 1,2,3,4. Here is the resultant gain coefficients. We are not sure why the gains vary by a factor of 5 at most among the segments. This variation can not be explained by the discrepancy in the transfer gain of the demodulation chain.

H1:IMC-WFS_A_I1_GAIN = 1
H1:IMC-WFS_A_Q1_GAIN = 1
H1:IMC-WFS_A_I2_GAIN = 5.33
H1:IMC-WFS_A_Q2_GAIN = 5.33
H1:IMC-WFS_A_I3_GAIN = 4.43
H1:IMC-WFS_A_Q3_GAIN = 4.43
H1:IMC-WFS_A_I4_GAIN = 1.33
H1:IMC-WFS_A_Q4_GAIN = 1.33
H1:IMC-WFS_B_I1_GAIN = 5.75
H1:IMC-WFS_B_Q1_GAIN = 5.75
H1:IMC-WFS_B_I2_GAIN = 1
H1:IMC-WFS_B_Q2_GAIN = 1
H1:IMC-WFS_B_I3_GAIN = 1.07
H1:IMC-WFS_B_Q3_GAIN = 1.07
H1:IMC-WFS_B_I4_GAIN = 5.47
H1:IMC-WFS_B_Q4_GAIN = 5.47

 

Compensation for the geometrical rotation:

As far as we remember there is a periscope in the IMC-REFL path which rotates the x-y relation of the beam, which rotates it by almost 90 degrees. Due to this effect the actual yaw motion happening in the IMC cavity shows up as almost pitch motion and vice versa at the RFFL port. We corrected this effect by manipulating the input matrix (IMC-WFS_A(B)_I_MTRIX) such that the yaw excitation shows up only in pitch basis after the input matrix. This adjustment was done by exciting the M2 stage of MC2 (which somehow we ended up with for some reason when exciting the angular motions) in pitch and yaw at 3 Hz. As a result the coupling between pitch and yaw were improved and separation ratio became approximately a factor of 50 at least which used to be 1 at worst. Here is the resultant matrix elements.


H1:IMC-WFS_A_I_MTRX_1_1 = 0.478812
H1:IMC-WFS_A_I_MTRX_1_2 = -1.33069
H1:IMC-WFS_A_I_MTRX_1_3 = -0.478812
H1:IMC-WFS_A_I_MTRX_1_4 = 1.33069
H1:IMC-WFS_A_I_MTRX_2_1 = 1.33069
H1:IMC-WFS_A_I_MTRX_2_2 = 0.478812
H1:IMC-WFS_A_I_MTRX_2_3 = -1.33069
H1:IMC-WFS_A_I_MTRX_2_4 = -0.478812
H1:IMC-WFS_B_I_MTRX_1_1 = 0.394297
H1:IMC-WFS_B_I_MTRX_1_2 = -1.35813
H1:IMC-WFS_B_I_MTRX_1_3 = -0.394297
H1:IMC-WFS_B_I_MTRX_1_4 = 1.35813
H1:IMC-WFS_B_I_MTRX_2_1 = 1.35813
H1:IMC-WFS_B_I_MTRX_2_2 = 0.394297
H1:IMC-WFS_B_I_MTRX_2_3 = -1.35813
H1:IMC-WFS_B_I_MTRX_2_4 = -0.394297
 

Measurement of the sensing matrix

The measurement of the sensing matrix went very smooth. We excited the M1 stage of the IMC suspensions. We considered two DOFs in pitch (yaw), namely common (differential) MC1-MC3 and MC2. This is the DOF basis that the Livingston people came up with in the IMC WFS commissioning. The excitation was injected to DOF_1(2)_Y(P)_EXC with an amplitude of 10-12 counts at about 3 Hz. To be sure that we are exciting the pure pitch or yaw we looked at the witness channels for the bottom stage and confirmed that we were exciting the right angular motion. Since we didn't have an auto-script to measure the sensing matrix we used diaggui to measure the transfer coefficient from the excitation to the WFSs. After measuring the 2x2 sensing matrix we inverted it and put it to the control input matrix IMC-INMATRIX_P(Y). In diaggui the frequency resolution was set to 0.01 Hz. Here is the resultant input matrix.

H1:IMC-INMATRIX_P_1_1 = 0.64725
H1:IMC-INMATRIX_P_1_2 = -0.35275
H1:IMC-INMATRIX_P_2_1 = -0.159639
H1:IMC-INMATRIX_P_2_2 = 0.840361

H1:IMC-INMATRIX_Y_1_1 = -0.163134
H1:IMC-INMATRIX_Y_1_2 = -0.836866
H1:IMC-INMATRIX_Y_2_1 = 0.529564
H1:IMC-INMATRIX_Y_2_2 = 0.470436


Closing the loops:

The trial of closing the loops were relatively easier compared with what we did to reach this point. We simply started from a small gain of 1e-4 and we fiddled with the sign. Since this was the first time for us to close the loops we enabled only fundamental control filers, namely FM6 (0.06, 0.1) and FM7(0:1) of IMC-DOF_1(2)_P(Y) and disabled the rest of the fancy filters. We aimed an UGF of  a few 10 mHz or so. The gains were adjusted by looking at the time scale of the control against a disturbance. The gains we ended with were :

H1:IMC-DOF_1_P_GAIN = -1e-05
H1:IMC-DOF_2_P_GAIN = -1e-05
H1:IMC-DOF_1_Y_GAIN = -1e-05
H1:IMC-DOF_2_Y_GAIN = -1e-05
 

What are missing ?:

Comments related to this report
christopher.wipf@LIGO.ORG - 12:53, Thursday 06 June 2013 (6653)
The DOF3 (MC2 TRANS centering) loops have been turned on, currently with very low UGF (step response ~minutes).  They worked "out of the box" using the LLO filters, and a bit of tweaking of the DOF3 gains.

Under $USERAPPS_DIR/ioo/h1/scripts/imc there's a new script, mcwfsrelieve, which offloads the DOF1/2/3 outputs onto the downstream filter modules (H1:IMC-MC1_PIT et al).

There's also a rudimentary_autolocker script for the IMC (temporary stopgap until the Guardian is up and running here).

Though we have plenty of optimization left to do, the IMC now has a reproducible baseline configuration, which is its main requirement during HIFO-Y.
LHO VE
kyle.ryan@LIGO.ORG - posted 16:32, Wednesday 05 June 2013 (6645)
Connected leak detector to YBM Turbo
Valved-in YBM Turbo and sporadically sprayed helium (audible flow) around chambers and misc. ports of Vertex volume currently under vacuum looking for any "easy" big leaks -> detector baseline 4 x 10-9 torr*l/sec -> Note, this exercise does not constitute a "leak test" -> Will do formal leak hunting as opportunities present themselves over the next few days? weeks?  
LHO VE
kyle.ryan@LIGO.ORG - posted 16:20, Wednesday 05 June 2013 (6644)
Began pumping GV2 annulus volume @ 1200 hrs. local
Modification to external piping recently completed by Apollo -> Entire annulus volume (including gate annulus) had been vented to facilitate this mod -> Gate annulus volume is temporarily combined with rest of annulus volume being pumped by aux. cart -> 1.5" all-metal isolation angle valve to be closed after a few days to re-isolate gate annulus volume (i.e. restore nominal configuration).
H1 INS
jodi.fauver@LIGO.ORG - posted 14:27, Wednesday 05 June 2013 (6642)
ETMX Install Prep
The concrete floor at the spool was covered with CPStat after the PEM fence was removed. The CPB jigs were moved to the far side of the beam tube by Apollo and then the tech cleaners removed Sharpie and other egregious "stuff" from them.The ISI storage container top was removed from the VEA and taken to X-Mid. The E-module and spiral staircase were moved down to the end and then the E Module was moved into the VEA. 

A small piece of vinyl was torn up by the big pallet jack used for the ISI. Since the tear is in the Test Stand area, John is contacting the vendor to get a repair taken care of before the ISI is in place.

LHO General
cheryl.vorvick@LIGO.ORG - posted 12:50, Wednesday 05 June 2013 (6637)
Ops Summary
Morning Alarms:
- CDS all are CPU Max and IOP watchdogs - no action necessary 
- Dust alarms are all due to working people - no action necessary

Morning work:
- forklift work near test stands in LVEA

Currently:
- Filiberto in LVEA fixing cables on the CM servo board.
H1 CDS
alexan.staley@LIGO.ORG - posted 09:34, Wednesday 05 June 2013 (6639)
Reboot H1ECATEY
(Sheila, Alexa)

Reboot EY Ethercat System
H1 SEI
hugo.paris@LIGO.ORG - posted 09:14, Wednesday 05 June 2013 (6636)
IMC ISI - Active Isolation On

Active control was left off to avoid perturbating the investigation of a large unexplained offset whitnessed on MC1.

I turned the active control back on this morning, on both HAM2 and HAM3 ISI to help locking the IMC, and assess performance. Active control is the same as it was for the IMC test:

Recent performance spectra can be found here.

H1 SUS
betsy.weaver@LIGO.ORG - posted 08:21, Wednesday 05 June 2013 (6634)
Q3 ETMx Lower Structure removed from test stand

On Monday, Andres and I removed the ETMx all-metal lower structure from the staging building test stand and boxed it in prep for a move to Ex for it's monolithic re-build.

H1 IOO
kiwamu.izumi@LIGO.ORG - posted 06:27, Wednesday 05 June 2013 (6633)
IMC WFS loop closed

[Chris W., Kiwamu I.]

The IMC WFS loop were successfully closed.

We left the the IMC locked with the WFS loops ON to see how they work overnight. Some details will be posted later.

LHO General
patrick.thomas@LIGO.ORG - posted 20:09, Tuesday 04 June 2013 (6631)
plots of dust counts
Attached are plots of dust counts requested from 5 PM June 3 to 5 PM June 4.

Both the dust monitor at location 14 in the LVEA (H2 PSL enclosure) and the dust monitor at location 16 in the LVEA (H1 PSL anteroom) are indicating calibration failures.
Non-image files attached to this report
H1 ISC
jaclyn.sanders@LIGO.ORG - posted 18:05, Tuesday 04 June 2013 - last comment - 11:10, Wednesday 05 June 2013(6627)
Further adventures in arm locking

(Jax, Alexa, Stefan, Sheila, Daniel)

Arm locking achieved! 

As of 18:00 local time, we're getting lock to 00 at a level of 10000 cts on H1: ALS-Y_REFL_B_LF_OUT, out of a maximum of about 22000 cts. This is about a 50% drop. 

We've touched up the pitch and yaw to improve locking characteristics. The current positions in pitch/yaw are 

ETM: (-142.7, 197.0)

ITM: (247.5, -271.5)

The current gain on CMB-B input 1 is -18 dB. 

Comments related to this report
stefan.ballmer@LIGO.ORG - 18:17, Tuesday 04 June 2013 (6628)
Key for the stable locking was increasing the M0_DAMP filters for Length, Pitch and Yaw from a gain of 1 to 5 (Vincent pointed me to it.).
This quieted down the cavity angular motion enough that it became possible to do a good manual alignment. (see Jax' elog for alignment values).
(This also confirms that the 0.5Hz pich motion we observed was due to the Quads.)

Now the alignment is very steady, and almost all of our lock losses are associated with H1:ALS-Y_REFL_FMON_OUT reaching plus or minus 5000 counts, indicating a control signal range problem.
stefan.ballmer@LIGO.ORG - 18:36, Tuesday 04 June 2013 (6629)
Some screen shots for documenting the state.
Images attached to this comment
alexan.staley@LIGO.ORG - 18:37, Tuesday 04 June 2013 (6630)
(Jax, Alexa)

Attached is a picture of the transfer function for the ALS cavity locking common mode board B of excitation A. (Note the two different images have a different y-axis scale). 
Images attached to this comment
sheila.dwyer@LIGO.ORG - 20:41, Tuesday 04 June 2013 (6632)
We changed the settings of the ALS laser at the end station, they are now:
diode current 1.842
diode temp: 31.38
SHG crystal temp: 33.81

We also looked at the transfer function for the PLL. With the settings we were using (in1 gain =-4, fast gain =-10, common comp and fast option enabled) the ugf was 10kHz, we have now set the in1 gain to -1dB and the ugf is 17kHz.  We are also able to enable one common boost, which has been added to the autolocker.  I also shortened the gain ramping time. 

I also changed the fiber distribution library, so that the RF mon can drift by 2dB without causing an error.  
jaclyn.sanders@LIGO.ORG - 08:54, Wednesday 05 June 2013 (6635)

As requested by Daniel, the TMS pointing is (-14400,9170). This hasn't changed from initial alignment conditions (yet).

Images attached to this comment
vincent.lhuillier@LIGO.ORG - 11:10, Wednesday 05 June 2013 (6640)

Here are the positions of the BSC-ISI. CPS offsets are presented in nm.
HEPI-BSC1: Locked https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=6566
HEPI-BSC6 is control in position
ISI-BSC6: Blend at 250mHz with T240 and level 3 controller
ISI-BSC1: Blend at 250mHz with T240 and level 1 controller

June 4, 2013, 18h00PT ISI
  DOF ETMY ITMY
ST1 X 28272 -22465
Y 23662 -19540
RZ -34715 -3175
Z 27000 12970
RX 41889 6608
RY -2182 -20265
ST2 X -1158 -5465
Y 2122 -4336
RZ -21183 -7981
Z 7428 15438
RX -13021 18375
RY 833 -10010
H1 CDS
james.batch@LIGO.ORG - posted 12:48, Tuesday 04 June 2013 - last comment - 09:25, Wednesday 05 June 2013(6617)
Restart of data concentrator
Added H1ECATC1_PLC2.ini, H1ECATY1_PLC1.ini, H1ECATY1_PLC2.ini, H1ECATY1_PLC3.ini to master file, removed H1EDCU_ECATC1.ini.  Also edited H1EDCU_DUST.ini to include H1 diode room dust monitor channels.  Restarted data concentrator, but data concentrator could not parse the H1ECATC1_PLC2.ini file.  Error message "failed to locate first section in ...H1ECATC1_PLC2.ini"  

Edited the new H1ECAT* files, found "units=" missing actual units. Corrected, but the data concentrator still failed with the same error.  Changed slope from 1 to 1.0, removed ^M from the end of the lines, no change, data concentrator still failed.

Finally commented out the H1ECAT*.ini files to restart the data concentrator, as 20 minutes had passed.

Examined the H1ECATC1_PLC2.ini file with "od -c", found 2 unprintable characters at the beginning of the file (octal 377, 376) at the beginning of the file, and each "normal" character has a trailing 000 (byte of value 0) after...

0000000 377 376   [  000   d  000   e  000   f  000   a  000   u  000   l  000

Compare with a working .ini file:

0000000   [   d   e   f   a   u   l   t   ]  

The script that generated the H1ECAT*.ini files needs some repair.



Comments related to this report
daniel.sigg@LIGO.ORG - 18:02, Tuesday 04 June 2013 (6626)
Guess the frame builder doesn't take Unicode...
james.batch@LIGO.ORG - 09:25, Wednesday 05 June 2013 (6638)
The H1ECAT files are in a UTF-16 format.  To convert to an ASCII format that the data concentrator can read, use the command iconv on a Linux workstation, as in the following:

iconv -f UTF-16 -t UTF-8 H1ECATC1_PLC2.ini > tmp.txt
mv tmp.txt H1ECATC1_PLC2.ini