Displaying reports 77041-77060 of 86550.Go to page Start 3849 3850 3851 3852 3853 3854 3855 3856 3857 End
Reports until 12:16, Tuesday 04 February 2014
H1 General
andres.ramirez@LIGO.ORG - posted 12:16, Tuesday 04 February 2014 (9804)
Re-starting ETMX/ITMX models - Arnaud


			
			
H1 DAQ
james.batch@LIGO.ORG - posted 12:10, Tuesday 04 February 2014 (9803)
Rebooted h1nds1 to clear stale NFS mount
h1nds1 was rebooted to clear a situation where it appeared that both h1fw0:/trend and h1fw1:/trend were mounted to the same /trend mount point.

H1 CDS
patrick.thomas@LIGO.ORG - posted 11:44, Tuesday 04 February 2014 - last comment - 11:45, Tuesday 04 February 2014(9799)
updated conlog channel list
Conlog is now using the channels in /ligo/lho/data/conlog/h1/target_grep_channel_list.txt (attached).
This file contains 96,957 channels. Conlog is currently not connecting to 3,416 of them.
Non-image files attached to this report
Comments related to this report
patrick.thomas@LIGO.ORG - 11:45, Tuesday 04 February 2014 (9800)
The list of unconnected channels is attached.
Non-image files attached to this comment
H1 SUS
arnaud.pele@LIGO.ORG - posted 11:22, Tuesday 04 February 2014 (9794)
ETMY TF looking good

A set of TF was ran overnight on the ETMY after some test-stand alignment, to check for rubbing. Measurements were succesfull and are not showing any signs of rubbing for both chains.

Attached are the comparison with the model for the main (1st pdf) and reaction chain (2nd pdf).

Non-image files attached to this report
H1 CDS
daniel.sigg@LIGO.ORG - posted 11:17, Tuesday 04 February 2014 (9797)
Fiber timing delays

Looking at the time delay as measured by the timing system:

Station Round-trip delay(µs) One-way delay (µs)
Corner-EX 43.0 21.5
Corner-EY 43.4 21.7
H1 General
andres.ramirez@LIGO.ORG - posted 10:42, Tuesday 04 February 2014 (9793)
Praxair LN2 Delivery


			
			
H1 ISC
filiberto.clara@LIGO.ORG - posted 10:40, Tuesday 04 February 2014 - last comment - 12:28, Tuesday 04 February 2014(9792)
QPD Transimpedance Amplifier - EX
Looked at the QPD Transimpedance Amplifier units at EX, S1102832 and S1102821.  We wanted to confirm the board versions. All boards D1001974 are version 2 and have the following configuration:
- C15 is removed
- R15 is 0 ohms
- JP1 has a jumper installed

Filiberto Clara
Comments related to this report
keita.kawabe@LIGO.ORG - 12:28, Tuesday 04 February 2014 (9798)

Sorry, I was wrong, but things still look dubious.

From the attached dark spectra of QPD segments,  TR_A needs digital dewhite, it doesn't look like TR_B has too much dewhite.

But TR_B still looks like it has some kind of problem, maybe white/dewhite mismatch for seg3 and seg4 (or seg1 and seg2). Needs to be checked later.

Images attached to this comment
H1 AOS
keita.kawabe@LIGO.ORG - posted 10:12, Tuesday 04 February 2014 - last comment - 11:10, Tuesday 04 February 2014(9790)
Initial alignment data for IAS

FYI, IAS:

Below is the table of the ETM and ITM bias slider offset  when the arm was aligned. Xarm data is right after we saw some green fringing (https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=9064). I'm taking HIFO-Y data for Y arm (https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=6627) even though HIFO-Y was more than a year after H2 EY was pumped down, as the slider was not calibrated during OAT, the data channels were all H2 so it's hard to track it down using data viewer now, and  I don't know how much the output matrix changed (the uncalibrated slider data is still available e.g. here: https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=3363).

  EX IX EY IY
PIT urad 332.5 82.8 -142.7 247.5
YAW urad -3.75 -55.5 197 -271.5

Though EX, IX and IY all needed to be pointed down, EY needed to be pointed up (the slider sign convention is such that a positive PIT offset points the optic down).

Slider calibration is probably 15%-ish good or maybe better based on the measurement of baffle PD positions.

OTOH, the earth radius is about 6400km. The angle between the local vertical of EX and the corner is about 4km/6400km=630urad.

Comments related to this report
daniel.sigg@LIGO.ORG - 11:05, Tuesday 04 February 2014 (9795)

The relation between the gloabl and local coordinate system is defined in T980044.

keita.kawabe@LIGO.ORG - 11:10, Tuesday 04 February 2014 (9796)

Again FYI:

We know from the excercise of offloading TMS PIT to HEPI, and then offloading HEPI PIT back to TMS, that the PIT of HEPI doesn't affect the PIT of ETMX much.

H1 DAQ (CDS)
james.batch@LIGO.ORG - posted 10:12, Tuesday 04 February 2014 (9789)
Changed default NDS server to h1nds0
The default nds server is now h1nds0.  We will be performing maintenance on h1nds1 over the next couple of days.
H1 CDS
james.batch@LIGO.ORG - posted 10:11, Tuesday 04 February 2014 (9788)
New version of gds software installed
A new version of gds software has been installed, addressing the following issues:

299, 328, 389, 428 - Any combination of start, stop, and BW that result in an fft of 512 points fails, due to how the fftw library is used by diag.  Fix by changing the way the fftw plan is generated, specifying FFTW_MEASURE instead of FFTW_ESTIMATE.

497 - Add option to foton to allow specifying a SFM name along with a filter file name.  See foton man page for details on the "-s" option.

500 - Removed Kaiser Window option from diaggui, it was never implemented.

511 - Changed foton to report that no design string exists for a filter if that is the case.  Previously this was reported as a different misleading problem.

519 - Allow IP broadcast for awg, tp discovery to be specified by an environment variable (LIGO_RT_BCAST) instead of assuming the broadcast address of the workstations.  

All these changes have been built from gds/branch/gds-2.16.9.  This affects Linux and Mac OS X workstations.  Existing diag or diaggui sessions should continue to work using the older software, but at some point we need to make network switch modifications that will cause the older software to stop working.  Advanced warning will be given.

H1 PSL
andres.ramirez@LIGO.ORG - posted 10:09, Tuesday 04 February 2014 (9787)
PSL Check

Laser Status: 
SysStat is good
Output power is 29.3 W (should be around 30 W)
FRONTEND WATCH is Active
HPO WATCH is red

PMC:
It has been locked 6 day, 16 hr 34 minutes (should be days/weeks)
Reflected power is 1.1 Watts  and PowerSum = 12.1 Watts.
(Reflected Power should be <= 10% of PowerSum)

FSS:
It has been locked for 1 h and 6 min (should be days/weeks)
Threshold on transmitted photo-detector PD = 0.74V (should be 0.9V)

ISS:
The diffracted power is around 6.7% (should be 5-15%)
Last saturation event was 22 h and 26 minutes ago (should be days/weeks)
H1 SEI
hugh.radkins@LIGO.ORG - posted 10:01, Tuesday 04 February 2014 (9786)
WBSC2 BS HEPI V2 Actuator Parker Valve Swapped

At ~0946 I valved out the South Actuators on BSC2.  There was a little pressure bump at the Pump Stations but I didn't see any HEPIs trip from that.  The Valve has been replaced and in is bleed mode.  The valves to the South Actuators were reopened ~0907 but I couldn't get the Mac Air to come alive to watch.  Looking back at the trends (attached) the reopening was worse than the closing.  I haven't heard any complaints but certainly those HEPIs under position control may have seen a wobble.  I opened and closed these valves very slowly to give the servo time to keep up but obviously even slower is better.

Images attached to this report
H1 General
andres.ramirez@LIGO.ORG - posted 09:59, Tuesday 04 February 2014 (9785)
Vendor delivery on Site (water)


			
			
H1 General
andres.ramirez@LIGO.ORG - posted 09:55, Tuesday 04 February 2014 - last comment - 12:20, Tuesday 04 February 2014(9784)
Checking ISI cables in HAM 4 (LVEA) - Jeff B./Mitchell


			
			
Comments related to this report
andres.ramirez@LIGO.ORG - 12:20, Tuesday 04 February 2014 (9805)
Work completed.
LHO General
patrick.thomas@LIGO.ORG - posted 09:31, Tuesday 04 February 2014 (9783)
Ace Portable Toilets on site


			
			
H1 General
patrick.thomas@LIGO.ORG - posted 09:11, Tuesday 04 February 2014 - last comment - 10:25, Tuesday 04 February 2014(9782)
Filiberto to end X
Looking at QPD amplifier chassis.
Comments related to this report
andres.ramirez@LIGO.ORG - 10:25, Tuesday 04 February 2014 (9791)
He is back. Work Completed.
H1 ISC (TCS)
stefan.ballmer@LIGO.ORG - posted 01:18, Tuesday 04 February 2014 - last comment - 12:06, Tuesday 04 February 2014(9778)
TCS heating curve at low power
Evan, Kiwamu, Stefan

Tonight we left the PRMI locked, with a dither loop for ITMY, and a sqrt(POB18) gain scaling for MICH and PRC.
The ring heater was set at 0.75W for both upper and lower heater (total of 1.5W). The heat was turned on at 09:13:38 UTC.

The idea of this "low-heat" run is to keep the heating in a regime where the lens strength is roughly linear in the change in build-up. This should give us a good measurement of the lens-strength vs. time.
Comments related to this report
aidan.brooks@LIGO.ORG - 12:06, Tuesday 04 February 2014 (9801)

Here's the time evolution of the defocus of the test mass (single pass, thermal lens only, two different x-axis ranges) in response to a 1W step function in ring heater power at t=0s.

Images attached to this comment
Displaying reports 77041-77060 of 86550.Go to page Start 3849 3850 3851 3852 3853 3854 3855 3856 3857 End