Dave, Hugo,

New channels were added to the science frame yesterday (LHO aLog #7849). Those channels are defined in a simmulink block called GND_STS. The GND_STS block was copied from gnd_sts_library.mdl and pasted in the BSC-ISI top level models of ITMY, ETMY, and ETMX, as intended. The gnd_sts_library.mdl contained one GND_STS block for ITMY, one for ETMX, and one for ETMY. Those three blocks carried the same name, with different content. Yesterday's work indicated that the RCG got confused by the multiplicity of names, and picked the wrong GND_STS block from the library, to generate the .ini file, which lists the channels to be recorded in the science frame.

Yesterday's solution was to rename each of these GND_STS block, within gnd-sts_library.mdl, so they would have distinct names. Doing so, impacted the names of the channes saved in the science frame:
   GND_STS blocks were renamed as follow:
        - GND_STS_IY, for the one to be pasted in h1isiitmy.mdl
        - GND_STS_EX, for the one to be pasted in h1isietmx.mdl
        - GND_STS_EY, for the one to be pasted in h1isietmy.mdl

GND_STS channels in the Science Frame were then (in red, the diffence whith what was intended by T1300742):

  name: H1:ISI-GND_STS_HAM2_X_MON
  name: H1:ISI-GND_STS_HAM2_X_MON
  name: H1:ISI-GND_STS_HAM2_Y_MON
  name: H1:ISI-GND_STS_HAM2_Y_MON
  name: H1:ISI-GND_STS_HAM2_Z_MON
  name: H1:ISI-GND_STS_HAM2_Z_MON
  name: H1:ISI-GND_STS_HAM5_X_MON
  name: H1:ISI-GND_STS_HAM5_X_MON
  name: H1:ISI-GND_STS_HAM5_Y_MON
  name: H1:ISI-GND_STS_HAM5_Y_MON
  name: H1:ISI-GND_STS_HAM5_Z_MON
  name: H1:ISI-GND_STS_HAM5_Z_MON
  name: H1:ISI-GND_STS_ITMY_X_MON
  name: H1:ISI-GND_STS_ITMY_X_MON
  name: H1:ISI-GND_STS_ITMY_Y_MON
  name: H1:ISI-GND_STS_ITMY_Y_MON
  name: H1:ISI-GND_STS_ITMY_Z_MON
  name: H1:ISI-GND_STS_ITMY_Z_MON
  name: H1:ISI-GND_STS_IY_HAM2_X_MON
  name: H1:ISI-GND_STS_IY_HAM2_Y_MON
  name: H1:ISI-GND_STS_IY_HAM2_Z_MON
  name: H1:ISI-GND_STS_IY_HAM5_X_MON
  name: H1:ISI-GND_STS_IY_HAM5_Y_MON
  name: H1:ISI-GND_STS_IY_HAM5_Z_MON
  name: H1:ISI-GND_STS_IY_ITMY_X_MON
  name: H1:ISI-GND_STS_IY_ITMY_Y_MON
  name: H1:ISI-GND_STS_IY_ITMY_Z_MON
 
  name: H1:ISI-GND_STS_EX_ETMX_X_MON
  name: H1:ISI-GND_STS_EX_ETMX_Y_MON
  name: H1:ISI-GND_STS_EX_ETMX_Z_MON
 
  name: H1:ISI-GND_STS_ETMY_X_MON
  name: H1:ISI-GND_STS_ETMY_X_MON
  name: H1:ISI-GND_STS_ETMY_Y_MON
  name: H1:ISI-GND_STS_ETMY_Y_MON
  name: H1:ISI-GND_STS_ETMY_Z_MON
  name: H1:ISI-GND_STS_ETMY_Z_MON
  name: H1:ISI-GND_STS_EY_ETMY_X_MON
  name: H1:ISI-GND_STS_EY_ETMY_Y_MON
  name: H1:ISI-GND_STS_EY_ETMY_Z_MON
 

 

We found a workaround this morning, so the ground STS channels would be named correctly in the science frame:
    - We split gnd_sts_library.mdl into 3 distinct libraries:
        - gnd_sts_library_IY.mdl   (which contains the GND_STS block for ITMY)
        - gnd_sts_library_EX.mdl   (which contains the GND_STS block for ETMX)
        - gnd_sts_library_EY.mdl   (which contains the GND_STS block for ETMY)
    - The GND_STS blocks were copied, and connected, into the relevant models ( h1isiitmy.mdl, h1isietmx.mdl, h1isietmy.mdl)
    - We checked that the GND_STS blocks we pasted were linked to the correct simmulink libraties (gnd_sts_library_IY.mdl, gnd_sts_library_EX. mdl,gnd_sts_library_EY.mdl)
    - BSC-ISI models were recompiled for ITMY, ETMX and ETMY.
    - GND channel names were checked in the science frame. They are now correct (see below)

  name: H1:ISI-GND_STS_HAM2_X_MON
  name: H1:ISI-GND_STS_HAM2_Y_MON
  name: H1:ISI-GND_STS_HAM2_Z_MON
  name: H1:ISI-GND_STS_HAM5_X_MON
  name: H1:ISI-GND_STS_HAM5_Y_MON
  name: H1:ISI-GND_STS_HAM5_Z_MON
  name: H1:ISI-GND_STS_ITMY_X_MON
  name: H1:ISI-GND_STS_ITMY_Y_MON
  name: H1:ISI-GND_STS_ITMY_Z_MON
 
  name: H1:ISI-GND_STS_ETMX_X_MON
  name: H1:ISI-GND_STS_ETMX_Y_MON
  name: H1:ISI-GND_STS_ETMX_Z_MON
 
  name: H1:ISI-GND_STS_ETMY_X_MON
  name: H1:ISI-GND_STS_ETMY_Y_MON
  name: H1:ISI-GND_STS_ETMY_Z_MON 
 
 

Bottom line:

1. One should not expect RCG to pick the right simuling block, if this block has clones (same name) within the library it comes from.

2. The Seismic GND_STS (Ground streckeisen seimometers) channels are now recorded with the correct name in the science frame.

Images attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 12:10, Wednesday 25 September 2013 (7860)

The new BSC top-level models were commited to the SVN:

-rev 5737
    - h1isiitmx.mdl
    - h1isiitmy.mdl
    - h1isietmx.mdl
    - h1isietmy.mdl

-rev 5738
   - h1isibs.mdl

hugo.paris@LIGO.ORG - 14:21, Wednesday 25 September 2013 (7867)

Comments were added to the new gnd_sts_library_XX models to describe how to use the GND_STS blocks.

Models were commited under the SVN in /opt/rtcds/userapps/release/isi/common/models:

        - gnd_sts_library_IY.mdl    -r 5744
        - gnd_sts_library_EX.mdl   -r 5742
        - gnd_sts_library_EY.mdl   -r 5743

Images attached to this comment
H1 SEI
jim.warner@LIGO.ORG - posted 11:29, Wednesday 25 September 2013 (7859)
BSC9 Report Posted

In the DCC E1100849.

H1 AOS
thomas.vo@LIGO.ORG - posted 10:39, Wednesday 25 September 2013 (7857)
ETMX ACB
Apollo, Jodi, Thomas

All large tooling and parts have been stored in the tube adjacent to BSC9, awaiting the cartridge install.
LHO VE
kyle.ryan@LIGO.ORG - posted 10:17, Wednesday 25 September 2013 (7855)
Valved out RGA from HAM3, valved-out YMB turbo, valved-in IP5, 1 and 2, opened GV2
Continuous RGA data collection 
H1 ISC
christopher.wipf@LIGO.ORG - posted 21:02, Tuesday 24 September 2013 - last comment - 11:34, Friday 27 September 2013(7854)
h1lsc updates

After a third ADC card was added to the h1lsc0 I/O chassis (alog 7842), I edited the h1lsc model as follows:

The new model has been compiled, started, and checked into SVN.  Its MEDM overview, safe.snap and filter files will be updated and checked in tomorrow.

Images attached to this report
Comments related to this report
christopher.wipf@LIGO.ORG - 15:01, Wednesday 25 September 2013 (7856)

MEDM screens, filter file, and safe.snap have been updated and checked in. The filters from ALS_C_COMM_A_RF_I were moved to ALS_C_COMM_A_RF_ERR. More details about the rewiring:

  • MCREFL was moved from adc_0_28 to adc_2_0
  • All ALS inputs except DIFF_LF and COMM_LF are now on the new ADC (previously only one of them was connected, on adc_0_29)
christopher.wipf@LIGO.ORG - 11:34, Friday 27 September 2013 (7887)

The reflective memory links between h1lsc and h1iscex were not working, because the card number parameter of the cdsIPCx_RFM parts was wrong.  I had just copy-pasted the parts from EY to EX and forgot to change this parameter.  For the record, the correct card number settings are: "0" for EX and "1" for EY.  After the h1lsc and h1iscex models were updated to get this right, the RFM links came up. The updated models have been checked in to SVN.

H1 ISC
kiwamu.izumi@LIGO.ORG - posted 18:57, Tuesday 24 September 2013 (7851)
HAM1 in-vac work : installation on the west side

[Alexa, JoeG, Paul, Kiwamu]

 Today we mainly installed the optics on the west side (which is close to ISCT1) in HAM1 and placed all the optics in the west side except for the in-vac POP PD.

The REFL AIR path is aligned. We didn't align the POP/ALS path because we didn't have green light or bright POP beam at the moment. As for the in-vac REFL detector path we placed only M2. We will install the rest of them on the east side tomorrow.

 

Below are notes for some particular sections of the west side :

Beam Diverter 1 :

We had to rotate the beam diverter #1 (BVD1) by 180 deg. The beam diverter has a couple of small PEEK materials on the mirror holder and they were initially on the side where the REFL beam hits. So we wanted to avoid this. Since there is no PEEK materials on the other side of the holder we simply rotated the whole structure by 180 deg. Of course we also flipped the mirror itself such that its high reflection surface remains facing to the REFL beam. Note that the rotation of the actual BDV1 is now different from that in the layout drawing (LIGO-D1000313-v10) because of this modification.

REFL path :

Looking at M7, which we had installed before the HIFO started, we noticed that M7 was not at the place that the diagram showed (LIGO-D1000313-v10). It was too far from the west by 2" or so. But I remembered that the position of this mirror was adjusted to catch the REFL beam at its center. So we used this mirror as a reference to recover the good alignment of the IMs and PRM. After Paul untripped IM1-4, enabled the master switch of IM1-4 and set the alignment of PRM back to that in April, we got a decent alignment without a fine tuning.Checking the REFL beam on ISCT1 we confirmed the good alignment as the beam hit the REFL shutter trigger PD.

 We also checked the beam position on the view port on the HAM1/2 septum. It was well-centered. So regarding the REFL beam as a good reference we installed the relevant optics without touching the REFL beam pointing. So for the reason M7, M1, HW1 and M14 are off from the layout (LIGO-D1000313-v10) by about 2 inches or less toward the east. Finally M7 was repositioned because we added two beam splitters which can change the beam trace by non-negligible amount. Currently the REFL beam hits the center of the top periscope mirror on ISCT1. The beam is off somewhat on the bottom periscope mirror because we touched M7 but this is not a big deal because we can steer the top mirror.

 

M14 (a.k.a. pick off for high power beam dump):

M14, which had been a 50 % BS dedicated for HIFO (see LIGO-D1201390-v2), was replaced by a 90% S-pol BS (LIGO-E040512-B4 and also mentioned in Keita's alog #7844). The removed 50% BS is currently ln the clean booth nearby HAM1 in a bag labeled as "M14".

LHO General
patrick.thomas@LIGO.ORG - posted 18:55, Tuesday 24 September 2013 (7853)
plots of dust counts
Attached are plots of dust counts requested from 4 PM September 23 to 4 PM September 24.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 18:51, Tuesday 24 September 2013 (7852)
plots of dust counts
Attached are plots of dust counts requested from 4 PM September 22 to 4 PM September 23.
Non-image files attached to this report
H1 ISC
daniel.sigg@LIGO.ORG - posted 18:23, Tuesday 24 September 2013 - last comment - 13:15, Wednesday 25 September 2013(7850)
HAM1 feedthroughs

(Alexa, Daniel)

We checked the vacuum feedthrough flanges on HAM 1 and noticed that none of the double 5-way coax flanges were installed. The missing positions are D1-3, D4-2, D5-2, D6-2 and D6-3 (see D1002872). We are also missing a double D-sub feedthrough flange on position D1-3. With some help we were able to locate the missing flanges and they are awaiting installation.

We noticed that purge air port is located on D5-3 rather than D4-3 as the drawing would indicate. The easiest way to accommodate this difference is to simply route the TT signals through D4-3. It is already equipped with a double D-sub feedthrough flange.

We were able to find some of the in-air cables. The beam diverter cables were routed to the wrong side of the chamber. They were too short to reach the designated flange, so we had to reroute them. We are missing the cables for the LSC PD DC signals and still have to install the coax cables. We have cables for the picomotors, but will do a test first.

There is no SUS satellite amp in the ISC-R4 rack. All units are at LLO and are being shipped.

Comments related to this report
daniel.sigg@LIGO.ORG - 13:15, Wednesday 25 September 2013 (7864)

The picomotor cable has been tested and hooked up. We also installed the one that goes to ISCT1.

The beam diverter cables were tested and installed on D1-1 and not at D2-1 as shown in the drawing. D2-1 is inaccessible.

H1 SEI
hugo.paris@LIGO.ORG - posted 18:09, Tuesday 24 September 2013 (7849)
BSC-ISI : Models & MEDM were updated

 

Started by installing/testing the update on ITMY-ISI (h1isiitmy.mdl)

Ran an svn up on userapps/trunk/isi/common. Details of the svn up are attached.
 

Checker & WD - SEI aLog #257 

1 - Model Work:
      - Made sure that channels were now set to be recorded in the science frame (including the ODC channel)
      - Made sure that ISO and DAMP blocks got updated with the new logic to feed the ODC bit.
      - Added the GND_STS blocks from the gnd_sts_library.mdl into the top level model of ITMY. Directions in SEI aLog #262
        (Outputs of the master model were grounded in the top model for: BS, ITMX, partially ETMY, and partially ITMY, as planned. see attached screeshots).
 
    GND_STS blocks of gnd_sts_library.mdl were renamed:
    Having 3 blocks with the same name in the same .mdl file caused RCG to get confused. i.e. as it was set, rcg picked the GND_STS block for ETMX while compiling, causing the wrong STS channels (ETMX) to be recorded into       the science frame. This was fixed by renaming the 3 GND_STS blocks to
        - GND_STS_IY
        - GND_STS_EX
        - GND_STS_EY
       
      H1ISIITMY.ini:
           with unmodified GND_STS part
                  [H1:ISI-GND_STS_ETMX_X_DQ]
                  [H1:ISI-GND_STS_ETMX_Y_DQ]
                  [H1:ISI-GND_STS_ETMX_Z_DQ]
           After renaming GND_STS part (to GND_STS_IY)
                  [H1:ISI-GND_STS_IY_HAM2_X_DQ]
                  [H1:ISI-GND_STS_IY_HAM2_Y_DQ]
                  [H1:ISI-GND_STS_IY_HAM2_Z_DQ] 
                  [H1:ISI-GND_STS_IY_HAM5_X_DQ]
                  [H1:ISI-GND_STS_IY_HAM5_Y_DQ]
                  [H1:ISI-GND_STS_IY_HAM5_Z_DQ]
                  [H1:ISI-GND_STS_IY_ITMY_X_DQ]
                  [H1:ISI-GND_STS_IY_ITMY_Y_DQ]
                  [H1:ISI-GND_STS_IY_ITMY_Z_DQ]
    The correct STS channels are now recorded in the science frame.
 
2- Model was recompiled and restarted
------
3 - WD screens got updated ("set" and "reset" buttons available on top of the WD threshold)
4 - Safe values are correct:
      CPS:    20,000cnts
      GS13:  32,760cnts 
      L4C:    50,000cnts
      ACT:    32,760cnts
5 - If  a WD threshold is changed from its safe value, checker sets it back to the safe value, by increments of 1cnt.
6 - "set" and "reset" buttons behave as expected.
7 - Set CPS threshold to -1 -> saw it trip, and go back straight to 20,000
8 - Set CPS threshold to 2000.5 -> the checker incremets to 2001, and then increments by steps of 1count untils it reaches the safe vaule.
9 - Set the CPS threshold to 99,995cnts. Checker substract 1cnt every second. Pressed "set" and dialed 105,000cnts. Checker starts at 99,999 and counts down from there.
10- Pressed the "set" button. The counting down stoped. It started again from where it was left, 12s later.
11- Set CPS threshold to 20.008cts. Checker brings it back to 20,000cts (Safe Value), and stops there.
12- Repeated steps 7 through 11 on the thresholds of the GS13, L4C and ACT. All is OK.
13- Set all theshold 1000cts above safe. Saw them counting down, in sync The "set theshold safe" button, which should reset all the thresholds to safe, does not work, as expected (sei aLog #257)
------
14- Turned on DAMP and ISO lv2. (no filters loaded yet).
15- tripped the ISI by lowering the threshold on the CPS -> ISO filters get turned off. Ramp time and offsets get turned to 0. Offests also get disengaged.
 

Science Frame Channels - SEI aLOG #257

H1ISIITMY.ini
 
with unmodified gnd part
 
[H1:ISI-GND_STS_ETMX_X_DQ]
[H1:ISI-GND_STS_ETMX_Y_DQ]
[H1:ISI-GND_STS_ETMX_Z_DQ]
 
with modified part
 
[H1:ISI-GND_STS_IY_HAM2_X_DQ]
[H1:ISI-GND_STS_IY_HAM2_Y_DQ]
[H1:ISI-GND_STS_IY_HAM2_Z_DQ]
[H1:ISI-GND_STS_IY_HAM5_X_DQ]
[H1:ISI-GND_STS_IY_HAM5_Y_DQ]
[H1:ISI-GND_STS_IY_HAM5_Z_DQ]
[H1:ISI-GND_STS_IY_ITMY_X_DQ]
[H1:ISI-GND_STS_IY_ITMY_Y_DQ]
[H1:ISI-GND_STS_IY_ITMY_Z_DQ]
- DAQ restarted
- Expected channeles were added to the science Frame (all of HAM2-ISI science frame channels, but STSs which are sent by BSC)
 name: H1:ISI-HAM6_BLND_CPSRX_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSRY_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSRZ_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSX_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSY_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSZ_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13RX_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13RY_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13RZ_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13X_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13Y_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13Z_IN1_DQ
  name: H1:ISI-HAM6_FF_RX_IN1_DQ
  name: H1:ISI-HAM6_FF_RY_IN1_DQ
  name: H1:ISI-HAM6_FF_RZ_IN1_DQ
  name: H1:ISI-HAM6_FF_X_IN1_DQ
  name: H1:ISI-HAM6_FF_Y_IN1_DQ
  name: H1:ISI-HAM6_FF_Z_IN1_DQ
  name: H1:ISI-HAM6_MASTER_H1_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_H2_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_H3_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_V1_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_V2_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_V3_DRIVE_DQ
  name: H1:ISI-HAM6_ODC_CHANNEL_OUT_DQ
  name: H1:ISI-HAM6_WDMON_STATE_IN1_DQ
 
 

ODC GAIN SEI aLog #259

- Turned DAMP+ISO ON, on both stages.
- Put upated the correct state to match the current state so the ODC bit would be 1.
- Changed the gain of ISO_X to 0. ODC bit turns to 0.
- Did the same test on every degree of freedom of both stages, and got the same result.
- Same tests were perfomed on DAMP. Same results were obtained.
 

Ported the update to all the H1 BSC-ISIs

- Then, recompiled and restarted all the H1 BSC-ISI models
- ETMY could not be restarted. It has no computer assigned yet.
 
Note: The SItemap.mdl was updated to feature H1:ISI-ETMX. The new version is commited under the SVN as -r5735

 

Upates were completed on BSC-ISI and work as expected. -  the GND_STS blocks had to be renamed (localy for now)

 

Start testing on HAM6-ISI (h1isiham6.mdl)
##################################################################################################################
 
 
Checker & WD - SEI aLog #257 
****************************
 
1 -Opened model, made sure that:
- Channels were now set to be recorded in the science frame (including the ODC channel)
- ISO and DAMP block got updated with the new logi to feed the ODC.
 
2 - Make, make install and restart
 
------
3 - Checked that WD screens got updated
4 - Safe values are correct:
CPS:  20,000
GS13: 32,760
L4C:  50,000
ACT:  32,760
5 - if threshold changed from safe value to above/below (i.e. 2000cts on CPSs)-> check sets it back to the safe value, by increments of 1cnt.
6 - Set and reset buttons behave as expected.
7 - Set CPS threshold to -1 -> saw it trip, and go back straight to 20,000
8 - Set CPS threshold to 2000.5 -> the checker incremets to 2001, and then increments by steps of 1count.
9 - set the CPS threshold to 99,995cnts. Checker substract 1cnt every second. Pressed "set" and dialed 105,000cnts. Checker starts at 99,999 and counts down from there.
10- Pressed set. The counting down stoped. It started again from where it was left, 12s later.
11- Set CPS threshold to 20.0008cts. Checker brings it back to 20,000cts (Safe Value), and stops there.
12- repeated steps 5 through 11 on the GS13, L4C and ACT. All is OK.
13- Set all theshold 1000cts above safe. Saw them counting down, in sync The "set theshold safe" button, which should reset all the thresholds to safe, does not work, as expected (sei aLog #257)
 
------
- Turned on DAMP and ISO lv2. (no foton filters yet).
- tripped the ISI by lowering the threshold on the CPS -> ISO filters are disengaged. Ramp time and offsets are turned to 0. Offests are also disengaged.
NOTE: DACKILL & IOP DACKILL DO NOT AFFECT THE STATE OF THE ISO. SHOULD WE CHANGE THIS???
 
 
Science Frame Channels - SEI aLOG #257
***************************************
- DAQ restarted
- 26 channeles were added to the science Frame (all but STSs which are sent by BSC)
 
 
ODC GAIN SEI aLog #259
**********************
- Turned ISO on
- changed gain of ISO_X to 0, 0.9, and 1.1. ODC bit turns to 0 every time.
- Did the same test on every degree of freedom, and got the same result.
- Same tests were perfomed on DAMP. Same results were obtained.
 
##################################################################################################################
Porting updates to all the HAM-ISI
##################################################################################################################
 
- recompiled and restarted all the H1 HAM-ISI models
- safe.snap files were updated, and commited to the svn
controls@opsws1:burtfiles 0$ svn commit -m "HAM-ISI safe.snap files updated to match new models"  *ham*
Sending        h1isiham2_safe.snap
Sending        h1isiham3_safe.snap
Sending        h1isiham4_safe.snap
Sending        h1isiham5_safe.snap
Sending        h1isiham6_safe.snap
Transmitting file data .....
Committed revision 5734.
Images attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 16:48, Tuesday 24 September 2013 (7848)
Valved-out IP1,2,5,6 valved-in YBM turbo, valved-in HAM3 RGA -> closed GV2, valved-in IP6
Leaving YBM turbo and HAM3 RGA valved-in and scanning overnight 
LHO General
patrick.thomas@LIGO.ORG - posted 16:43, Tuesday 24 September 2013 (7847)
Ops Summary (PM)
All field cabling being removed from ETMX in preparation for cartridge insertion
Hugo restarting/testing modified ITMY ISI model
I updated the alarm level on dust monitor 8 to reflect that it may no longer be in a clean room
15:53 Jeff and Andres looking for parts near the LVEA test stand
Dust alarms in the H1 PSL diode room, checked once, saw no activity
LHO VE
kyle.ryan@LIGO.ORG - posted 16:32, Tuesday 24 September 2013 (7846)
CP5 overfilled today -> low level alarm likely tonight - no action required
Particular driver filling dewar using both "bottom fill" and "top fill" plumbing 
H1 ISC
keita.kawabe@LIGO.ORG - posted 16:22, Tuesday 24 September 2013 - last comment - 09:37, Monday 07 October 2013(7844)
List of optics in HAM1 (Corey, Keita)

This is a list of the ISC diagnostic optics in HAM1. Some of these are yet to be installed,  but all will be installed in this installation window.

The only differences between this and D1000313 are:

  1. M14, the first BS for the REFL, is a 90% S-pol splitter (E040512-B4), not a 95% P-pol (E1000871-V1-02) as in D1000313, as the reflectivity of the latter was measured to be too much for our purpose.
    • However, 90% is a bit too small, and we might want to insert another 50% splitter later.
  2. For M6 (50% P-pol splitter), we used iLIGO REO splitter (E040512-B1, marked "IO824-01" on the barrel) instead of newer ATF optic (E1000671-02) because I couldn't find the latter.
  3. We put a black glass behind M5, as all high reflectors upstream of M5 are with some kind of beam dump.
ID Type and DCC S/N or marking Mount Path etc. comments
M1 50% IR, E1000671-02 ? RH REFL air-vac splitter put in previously
M2 HR IR, E1100048 0990 LH with dump REFL vac steering newly put in
RM1 Curved +1.7m HR IR, E1100056-01 2 TT (S/N ???) REFL vac MM TT1 newly put in
RM2 Curved -0.6m HR IR, E1100056-03 24 TT (S/N ???) REFL vac MM TT2 newly put in
M5 Curved +1.7m HR IR, E1100056-01 3 RH with dump REFL vac MM fixed newly put in, different from D1000313
M6 50% IR, E040512-B1 (as opposed to E1000671-02) IO824-01 on the barrel LH with pico REFL vac LS/AS splitter newly put in, different from D1000313
M7 HR IR, E1100048 ? LH REFL air steering put in previously
M8 HR IR/GRN, E1000425 ? Peri wth dump POP/ALS peri put in previously
M9 HR IR/GRN, E1000425 ? Peri with dump POP/ALS peri put in previously
M10 HR IR, HT GRN, E1000669 ? LH POP/ALS dichroic put in previously
M11 HR GRN, E1000652 ? LH with dump ALS steering put in previously
M12 90% IR, E040512-B3 IO820-09 on the barrel LH POP vac/air splitter newly put in
M13 HR IR, E1100048 ? RH with dump PSL reference put in previously
M14 90% S-pol IR, E040512-B4 IO823-?? on the barrel RH REFL splitter for high power dump newly put in, different from D1000313
M15 HR IR, E1100048 0944 RH pico with dump POP vac steering for LSC newly put in
M16 HR IR, E1100048 0965 RH with dump POP air steering newly put in
M101 1" HR IR, E1000595 ? 1" LH with dump part of REFL WFS sled newly put in
M102 1" HR IR, E1000595 ? 1" LH with dump part of REFL WFS sled newly put in
M103 1" 50% IR, E1000671-02 ? 1" LH pico part of REFL WFS sled newly put in
M104 1" HR IR, E1000595 ? 1" LH pico with dump part of REFL WFS sled newly put in
L101 1" f=+334mm, E1000845-03 ? 1" lens part of REFL WFS sled newly put in
L102 1" f=-167mm, E1000845-08 ? 1" lens part of REFL WFS sled newly put in
L1 1" f=+222mm, E1000845-02 ? 1" lens for LSC REFL newly put in
L2 f=+334mm, E1000845-10 ? 2" lens for LSC POP newly put in
BDV1 HR IR, old iLIGO N/A (no marking) BDV for REFL air newly put in
BDV2 90% IR, E040512-B3 IO820-05 on the barrel BDV for POP air newly put in
HW1 1" IR half wave plate from ALS stock N/A (no marking) rotator mount for REFL newly put in

Note:

Comments related to this report
keita.kawabe@LIGO.ORG - 16:29, Tuesday 24 September 2013 (7845)

We rejected one optic (E040512-B3, IO822-07 on the barrel) because there were many (not too many) defects or particulates that we couldn't remove by nitrogen gun, gentle push using a wipe, nor a serious cleaning effort using methanol and a wipe.

It is still OK-ish, but it's not spotless either. I would have used that if nothing else is available. Anyway, that optic is now in "clean, with issues, or from SQZ" optics bin in the optics lab.

keita.kawabe@LIGO.ORG - 09:37, Monday 07 October 2013 (8018)

RM1 mount serial number: 024

RM2 mount serial number: 022

H1 INS
jodi.fauver@LIGO.ORG - posted 15:20, Tuesday 24 September 2013 (7843)
ETMX Install Prep
Karen and Cris did a very thorough cleaning this morning. Bubba, Randy and Scott headed down after lunch. The hard cover and the dome were removed from BSC9. (The dome is sitting on the SEI Storage Container pallet on clean Al blocks.) Walking plates were flown to the Work Platform, to be wiped down prior to installation. The SEI sock was installed.

H1 ISC
richard.mccarthy@LIGO.ORG - posted 14:12, Tuesday 24 September 2013 (7842)
ADC added to IO chassis
Installed 3rd ADC and interface card in the ISC IO chassis.  Moved cabling between ADC and interface card so back panel plugs are in proper order.
Installed another AA chassis in the rack power it up and ran scsi cable to it.
Filiberto/Richard
H1 General
andres.ramirez@LIGO.ORG - posted 12:42, Tuesday 24 September 2013 (7841)
Ops shift Summary (AM)
Ops Summary – 9/24/2013

Work at LVEA (drilling holes) – Apollo
Work at End X (cabling) – Filiberto
Work at LVEA (Packing and transporting  baffle parts) – Thomas Vo
H1ISI HAM6 restart – Hugo
Cleaning work on BSC9 and surrounding areas at End X – Christina/Cris/Karen
H1ISI HAM2/3/4 restart – Hugo
H1 SEI
hugo.paris@LIGO.ORG - posted 12:37, Tuesday 24 September 2013 (7840)
HAM-ISI : Models, MEDM & safe.snap were updated

Sebastien, Hugo
 

Started by installing/testing the update on HAM6-ISI (h1isiham6.mdl)

Ran an svn up on userapps/trunk/isi/common. Details of the svn up are attached.
 

Checker & WD - SEI aLog #257 

1 -Opened model, made sure that:
      - Channels were now set to be recorded in the science frame (including the ODC channel)
      - ISO and DAMP blocks got updated with the new logic to feed the ODC bit.
2 - Model was recompiled and restarted
------
3 - WD screens got updated ("set" and "reset" buttons available on top of the WD threshold)
4 - Safe values are correct:
      CPS:    20,000cnts
      GS13:  32,760cnts 
      L4C:    50,000cnts
      ACT:    32,760cnts
5 - If  a WD threshold is changed from its safe value, checker sets it back to the safe value, by increments of 1cnt.
6 - "set" and "reset" buttons behave as expected.
7 - Set CPS threshold to -1 -> saw it trip, and go back straight to 20,000
8 - Set CPS threshold to 2000.5 -> the checker incremets to 2001, and then increments by steps of 1count untils it reaches the safe vaule.
9 - Set the CPS threshold to 99,995cnts. Checker substract 1cnt every second. Pressed "set" and dialed 105,000cnts. Checker starts at 99,999 and counts down from there.
10- Pressed the "set" button. The counting down stoped. It started again from where it was left, 12s later.
11- Set CPS threshold to 20.0008cts. Checker brings it back to 20,000cts (Safe Value), and stops there.
12- Repeated steps 5 through 11 on the thresholds of the GS13, L4C and ACT. All is OK.
13- Set all theshold 1000cts above safe. Saw them counting down, in sync The "set theshold safe" button, which should reset all the thresholds to safe, does not work, as expected (sei aLog #257)
------
14- Turned on DAMP and ISO lv2. (no filters loaded yet).
15- tripped the ISI by lowering the threshold on the CPS -> ISO filters get turned off. Ramp time and offsets get turned to 0. Offests also get disengaged.
 

Science Frame Channels - SEI aLOG #257

- DAQ restarted
- 26 channeles were added to the science Frame (all of HAM2-ISI science frame channels, but STSs which are sent by BSC)
 name: H1:ISI-HAM6_BLND_CPSRX_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSRY_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSRZ_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSX_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSY_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSZ_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13RX_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13RY_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13RZ_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13X_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13Y_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13Z_IN1_DQ
  name: H1:ISI-HAM6_FF_RX_IN1_DQ
  name: H1:ISI-HAM6_FF_RY_IN1_DQ
  name: H1:ISI-HAM6_FF_RZ_IN1_DQ
  name: H1:ISI-HAM6_FF_X_IN1_DQ
  name: H1:ISI-HAM6_FF_Y_IN1_DQ
  name: H1:ISI-HAM6_FF_Z_IN1_DQ
  name: H1:ISI-HAM6_MASTER_H1_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_H2_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_H3_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_V1_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_V2_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_V3_DRIVE_DQ
  name: H1:ISI-HAM6_ODC_CHANNEL_OUT_DQ
  name: H1:ISI-HAM6_WDMON_STATE_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSRX_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSRY_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSRZ_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSX_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSY_IN1_DQ
  name: H1:ISI-HAM6_BLND_CPSZ_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13RX_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13RY_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13RZ_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13X_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13Y_IN1_DQ
  name: H1:ISI-HAM6_BLND_GS13Z_IN1_DQ
  name: H1:ISI-HAM6_FF_RX_IN1_DQ
  name: H1:ISI-HAM6_FF_RY_IN1_DQ
  name: H1:ISI-HAM6_FF_RZ_IN1_DQ
  name: H1:ISI-HAM6_FF_X_IN1_DQ
  name: H1:ISI-HAM6_FF_Y_IN1_DQ
  name: H1:ISI-HAM6_FF_Z_IN1_DQ
  name: H1:ISI-HAM6_MASTER_H1_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_H2_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_H3_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_V1_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_V2_DRIVE_DQ
  name: H1:ISI-HAM6_MASTER_V3_DRIVE_DQ
  name: H1:ISI-HAM6_ODC_CHANNEL_OUT_DQ
  name: H1:ISI-HAM6_WDMON_STATE_IN1_DQ
 
ODC GAIN SEI aLog #259
- Turned ISO on
- changed gain of ISO_X to 0, 0.9, and 1.1. ODC bit turns to 0 every time.
- Did the same test on every degree of freedom, and got the same result.
- Same tests were perfomed on DAMP. Same results were obtained.
 

Ported the update to all the H1 HAM-ISIs

- recompiled and restarted all the H1 HAM-ISI models
- safe.snap files were updated, and commited to the svn
controls@opsws1:burtfiles 0$ svn commit -m "HAM-ISI safe.snap files updated to match new models"  *ham*
Sending        h1isiham2_safe.snap
Sending        h1isiham3_safe.snap
Sending        h1isiham4_safe.snap
Sending        h1isiham5_safe.snap
Sending        h1isiham6_safe.snap
Transmitting file data .....
Committed revision 5734

 

Upates were completed on HAM-ISI and work as expected.

 

Start testing on HAM6-ISI (h1isiham6.mdl)
##################################################################################################################
 
 
Checker & WD - SEI aLog #257 
****************************
 
1 -Opened model, made sure that:
- Channels were now set to be recorded in the science frame (including the ODC channel)
- ISO and DAMP block got updated with the new logi to feed the ODC.
 
2 - Make, make install and restart
 
------
3 - Checked that WD screens got updated
4 - Safe values are correct:
CPS:  20,000
GS13: 32,760
L4C:  50,000
ACT:  32,760
5 - if threshold changed from safe value to above/below (i.e. 2000cts on CPSs)-> check sets it back to the safe value, by increments of 1cnt.
6 - Set and reset buttons behave as expected.
7 - Set CPS threshold to -1 -> saw it trip, and go back straight to 20,000
8 - Set CPS threshold to 2000.5 -> the checker incremets to 2001, and then increments by steps of 1count.
9 - set the CPS threshold to 99,995cnts. Checker substract 1cnt every second. Pressed "set" and dialed 105,000cnts. Checker starts at 99,999 and counts down from there.
10- Pressed set. The counting down stoped. It started again from where it was left, 12s later.
11- Set CPS threshold to 20.0008cts. Checker brings it back to 20,000cts (Safe Value), and stops there.
12- repeated steps 5 through 11 on the GS13, L4C and ACT. All is OK.
13- Set all theshold 1000cts above safe. Saw them counting down, in sync The "set theshold safe" button, which should reset all the thresholds to safe, does not work, as expected (sei aLog #257)
 
------
- Turned on DAMP and ISO lv2. (no foton filters yet).
- tripped the ISI by lowering the threshold on the CPS -> ISO filters are disengaged. Ramp time and offsets are turned to 0. Offests are also disengaged.
NOTE: DACKILL & IOP DACKILL DO NOT AFFECT THE STATE OF THE ISO. SHOULD WE CHANGE THIS???
 
 
Science Frame Channels - SEI aLOG #257
***************************************
- DAQ restarted
- 26 channeles were added to the science Frame (all but STSs which are sent by BSC)
 
 
ODC GAIN SEI aLog #259
**********************
- Turned ISO on
- changed gain of ISO_X to 0, 0.9, and 1.1. ODC bit turns to 0 every time.
- Did the same test on every degree of freedom, and got the same result.
- Same tests were perfomed on DAMP. Same results were obtained.
 
##################################################################################################################
Porting updates to all the HAM-ISI
##################################################################################################################
 
- recompiled and restarted all the H1 HAM-ISI models
- safe.snap files were updated, and commited to the svn
controls@opsws1:burtfiles 0$ svn commit -m "HAM-ISI safe.snap files updated to match new models"  *ham*
Sending        h1isiham2_safe.snap
Sending        h1isiham3_safe.snap
Sending        h1isiham4_safe.snap
Sending        h1isiham5_safe.snap
Sending        h1isiham6_safe.snap
Transmitting file data .....
Committed revision 5734.
Non-image files attached to this report
H1 ISC
alexan.staley@LIGO.ORG - posted 08:23, Tuesday 24 September 2013 (7839)
ISCT1/HAM1 work

(Alexa, Kiwamu, Daniel, Paul, Joe)

 

We started work on HAM1/ISCTI yesterday (please refer to D1000313 for HAM1 layout). In particular:

 

1) we moved the green path mirror M10 over by 4inch from its pervious location (away from M10, toward the PSL side)

2) we used the IR beam to approximiately align the green path onto the bottom periscope mirror of ISCT1 with this new location for M10

3) we moved the IR mirror M13 to be approximiately 8inch from M11 (on the HAM2 side)

4) we aligned the IR path onto the bottom periscopre mirror of the ISCT1

 

The green and IR path reach the bottom of the periscope at a suffecient seperation such that they each are centered on their own bottom periscope mirrors. We have also begun alignment of the IR path onto the SHG on ISCT1.

 

Here is a link with pictures.