Displaying reports 78781-78800 of 86440.Go to page Start 3936 3937 3938 3939 3940 3941 3942 3943 3944 End
Reports until 12:01, Monday 30 September 2013
X1 DTS
james.batch@LIGO.ORG - posted 12:01, Monday 30 September 2013 (7911)
Power fail recovery
Due to a pair of power failures, the DAQ test stand needed to be restarted.  All front end computers were rebooted.  The x1ldasgw computer was locked up and was rebooted.  The DAQ computers which mount the SATAboy disk array were also rebooted once the x1ldasgw was operational in order to get the file system mounted and the daqd processes running.  Finished about 11:45 PDT.
H1 CDS
james.batch@LIGO.ORG - posted 11:57, Monday 30 September 2013 (7909)
Recover from power failure
(David Barker, Cyrus Reed, James Batch)

LHO experienced a 2 second power fail at 00:40:43 PDT and a power glitch at 06:06 PDT which caused front end reboots.  Also affected were both CDS file servers.

The main file server entered a read-only state, while the backup file server locked up and was unresponsive.  Both file servers were restored by 08:30 PDT.

All front-end computers were powered off, as several were not logically attached to their I/O chassis.  On power up, the following computers still could not find the I/O chassis:

h1seib1
h1seih45
h1sush2b
h1susquadtst
h1susex
h1susexaux

In each case, turning the power switch on the front of the I/O chassis from on to off to on caused the I/O chassis to power up.  The computers were then power cycled to get the I/O chassis reattached.

At this point, there were IPC problems in which channels could not be received from the following computers:

h1lsc0
h1asc0
h1seih23
h1seih16
h1seib2

In order to correct this problem, the Dolphin switches in the MSR needed to be power cycled, which in turn required all computers in the MSR that were attached to the Dolphin network to be power cycled.  Once this was accomplished, and a few models manually restarted, all appears to be well.  The system is back in operation as of 11:30 PDT.
H1 PSL
sheila.dwyer@LIGO.ORG - posted 11:49, Monday 30 September 2013 - last comment - 12:25, Monday 30 September 2013(7908)
PSL restarted
after the power glitch the PSL had to be restarted.  Justin and I followed the procedure to start it in low power mode, we reset the kepco HV supply to 200mA, as Christina wrote in her alog instead of the 400mA in the procedure.  We also reset the LRA, even though we were starting it in low power mode I wasn't sure if the beckhoff computer had lost power or not.  

The only hitch was that we couldn't open the external shutter, the situation was similar to  last time , 
H1:PSL-MIS_FLOW_OK was 0, although H1:PSL-MIS_FLOW_INMON was within the limits.  We tried the reset button on the medm screen, which didn't do anything, and we tried caput which also didn't change the value.  Jim and Dave managed to open it, they will write a log about what they did.  

The PMC is now locked, but the medm screen reports -30W transmitted power.  H1:PSL-PWR_PMC_TRANS_GAIN is now -0.024, while it was 1 before the power glitch.  

The ISS is not staying locked, which was also the case before the power glitch.  
Comments related to this report
sheila.dwyer@LIGO.ORG - 11:58, Monday 30 September 2013 (7910)
The safe.snap files for the PSL are out of date, Dave did a burt to friday and the PMC transmission is now making sense. The ISS is also locked now.  
christina.bogan@LIGO.ORG - 12:25, Monday 30 September 2013 (7912)
The new configuration for the shutter is that you have to press the reset button on the MEDM laser screen each time the system is restarted. Did you had any other problems?

The power supply should be set to 400mA as in the procedure, I think this isn't right in my alog. 

Please go ahead and create new safe.snap files. 
LHO General
patrick.thomas@LIGO.ORG - posted 08:50, Monday 30 September 2013 (7906)
restarted and burtrestored IOCs for h0dustlvea and h0dustdr
These needed to be restarted after an apparent power glitch from a wind storm.
H1 IOO
cheryl.vorvick@LIGO.ORG - posted 06:55, Saturday 28 September 2013 (7901)
IO PSL Work: setup for isolation ratio measurement of FI

- Joe, Paul, Cheryl

 

FI Isolation Measurement:

Two 2" beam splitters were installed in the main IO path, and the IMC was relocked. The beam splitters are at about 45 degrees w.r.t. the beam, and both reduce the power going into the IMC, requiring a change in threshold to lock the IMC.  Locking was briefly delayed after a reboot to the LSC brought it back with outputs turned off, but after reenabling the LSC the IMC relocked right away.  WFS were engaged, and the offsets WFS sent to each IMC optic were within +/-4 (units?) of the offsets during the IMC lock before we installed the two beam splitters, so input pointing was very closely restored.

The purpose of the two beam splitters is to catch the beam that makes it back through the FI and IMC, which gives us a measurement of the isolation ratio of the FI. The return beam should reflect off the back surface of the second beam splitter, but unfortunately, the return beam was either not present or overwhelmed by a direct reflection of the 2" lens downstream. 

The rework of the IO path in March left that 2" lens (dowstream of the second beam splitter) at a very shallow angle to the IO beam, so basically 90 degrees to the beam. This means the reflection from that lens it makes back to the EOM is now actually clipping on the output aperture of the EOM.  Before the rework the reflection was offset from the EOM output aperture by about 10mm. When Volker was at LHO this Summer and I made him aware of the clipping, it was decided to delay the fix (rotating the lens), until we go to high power, since it will efect the input pointing to the IMC.

Rotating the lens to eliminate the clipping on the EOM will be necessary before going to high power.  Rotating the lens now would be beneficial to the isolation measurement, and given the feducials we have, and the reliability of the IMC locking, I believe we should go ahead and rotate the lens.

 

General PSL comments:

 

Both temporary beamsplitters have their reflected beams dumped on razor blade dumps. I installed s ome additional dumps on the PSL table. My alignment irises that track the pointing of the IO path on the PSL show that the beam has shifted in YAW since I aligned the irises. My iris that looks at the leakage beam from the steering mirror at the output of the PMC also shows a change in pointing, probably related to the recent PSL work.

LHO General
patrick.thomas@LIGO.ORG - posted 19:12, Friday 27 September 2013 (7900)
plots of dust counts
Attached are plots of dust counts requested from 4 PM September 26 to 4 PM September 27.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:06, Friday 27 September 2013 (7898)
plots of dust counts
Attached are plots of dust counts requested from 4 PM September 25 to 4 PM September 26.
Non-image files attached to this report
H1 ISC
kiwamu.izumi@LIGO.ORG - posted 18:45, Friday 27 September 2013 - last comment - 21:19, Monday 30 September 2013(7897)
HAM1 in-vac work : mirror was flipped in a tip-tilt and too big pitching was found in the other

[JoeG, Keita and Kiwamu]

We continued working on the HAM1 installation this afternoon.  All the optics except for the detectors are now on the table including the newly installed QPD sled. We removed the counter weights although didn't check the table level yet.

Besides, there are two (unhonourable) highlights to mention from today's HAM1 incursion.

  1. The mirror of a tip-tilt (RM1) was found to be backward. So we flipped it to the right direction in situ.
  2. The other tip-tilt (RM2) started showing a too big pitching

 

A big pitching in a tip-tilt (RM2):

After the removal of the counter weights we went through the alignment process again in the in-vac detector path. The alignment needed a slight touch mainly in pitch. Then we found that RM2, which is a tip-tilt , showed a large pitching so that the reflected beam went too low. Joe tried to correct it by screwing the bottom 8-32 screw further in. This screw is designed such that as we screw it in, the center of its mass changes the pitching of the whole holder (so as to lower reflected beam). We wanted screw it in further but however the screw was too long and in fact it was already touching the back cage. Keita brought a shorter screw which is 8-32 x 1" and we tried this. However sadly it still hit the back cage because of too large pitching. Joe translated the upper blades to the front to separate the back cage and holder further apart, but this didn't fix the issue. Note the mirror holder was picthing in the same direction even without the screw.

According to our inspection, the clamping point of the wire on the left wire clamp (when looking from the front) on the mirror holder is too close to the back side. Probably about 1 mm off from the center toward the back side. The other side looked also close to the back side but not as big as the left side. At the moment we think this gives such pitching in the mirror holder. Pictures of the clamping point for both left and right sides are attached below. You can see how they are clamped through a rectangular window of the side cage. We have no idea of if it has been like this or when and why this happened. Adjusting the clamping point is certainly beyond what we can do in the chamber because it probably involves with all the alignment and adjustment process. Therefore we removed the tip-tilt our of the chamber. It is now in the clean booth nearby HAM1.

Plan :

 Next week we will bring another tip-tilt which was assembled for HAM6 and swap the bad one with it. Hopefully we can smoothly place the tip-tilt and move on to some measurements for checking the mode matching.

Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 10:57, Saturday 28 September 2013 (7902)

Some more pictures are available in ResourceSpace.

suresh.doravari@LIGO.ORG - 16:33, Sunday 29 September 2013 (7904)
The wire not being centered in the clamp is intentional.  This is because with the wire centered I found that the tip-tilt mirror tips backwards and it will require some pretty heavy counter balance screw to correct its pitch.  At least this is my experience.  I had started with the wire centered and faced this problem.  I solved it by displacing the wire and then sliding the clamps on the mirror holder to coarse adjust the pitch angle.
bram.slagmolen@LIGO.ORG - 21:19, Monday 30 September 2013 (7924)

Yes, that is correct. The wires are not clamped in the centre of the mirror wire clamp. The Wire Clamping Jig is designed to accommodate this offset in a controlled way. This also includes that there is a 'LEFT' and a 'RIGHT' suspension wire assembly.

I will see to get some dimensions.

LHO General
patrick.thomas@LIGO.ORG - posted 17:01, Friday 27 September 2013 (7896)
Ops Summary (PM)
12:00 Thomas V. out of the LVEA, to return later
12:14 I increased the dust alarm levels at end Y location 1 to conditions outside of a clean room
13:01 Dave B. and Jim B. to end Y
13:33 Dave B. power cycling ISCEY to fix an IPC error
13:56 Jim B. trying to start h1susey
14:10 Jim B. trying to start h1susauxey
14:16 Jim B. and Dave B. to end Y to swap the cabling between the sus and susaux frontends and their chassis. (sus was going to susaux, susaux was going to sus)
14:51 fw1 has stopped writing frames, Dave B., Jim B., Cyrus R. and Dan M. investigating
15:52 Cheryl V. and Paul F. done working in H1 PSL laser room on isolation measurements

High dust count spike at .3 microns in H1 PSL diode room, investigated, lights off, nobody responded
Hugo P. waiting for work to complete in HAM1 to start MC measurements
Filiberto C. done with SUS and SEI field cabling at end X
H1 CDS
david.barker@LIGO.ORG - posted 16:33, Friday 27 September 2013 (7895)
started h1susey and h1susauxey, rebooted h1iscey

Jim and Dave

The EY IO Chassis for h1susey and h1susauxey are powered and ready for use. We started the EY SUS front end computers this afternoon. I'll hold off until next week adding these to the DAQ. h1seiey will wait until its IO Chassis is ready to be powered up. Work done under WP#4154

While investigating an IPC error between the end station ISC models and the LSC in the corner, we ended up power cycling h1iscey to clear RFM receive errors at the LSC front end.

H1 SEI
hugo.paris@LIGO.ORG - posted 16:15, Friday 27 September 2013 (7894)
HAM3-ISI - Measurements Tonight

I scheduled a tilt frequency mesaurement on HAM3-ISI. It wil start tonight at 9pm PCT. It will last most of Saturday.

H1 SUS
filiberto.clara@LIGO.ORG - posted 16:06, Friday 27 September 2013 (7893)
ETMX BSC9
All field cables have been dressed to BSC9 chamber for SEI and SUS. Associated electronics are currently off ( SUS coild drivers, SEI/ISI GS13 T240 L4C ect.).
LHO VE
rainer.weiss@LIGO.ORG - posted 15:57, Friday 27 September 2013 (7892)
Hydrocarbon Pressure Measurement in the LVEA after 145 days of pumping
Kyle Ryan, R. Weiss
The total hydrocarbon pressure of the selected set is 6.2 e-13 torr. There is a good chance that
after another several hundred days and the additional pumping speed provided by both
cryo traps the total pressure will get close to 1 e -13. The report is on the DCC as T1300840 
as well as appended to this entry. 
Non-image files attached to this report
H1 SEI
hugo.paris@LIGO.ORG - posted 13:56, Friday 27 September 2013 - last comment - 15:09, Friday 27 September 2013(7890)
HEPI-HAM3 - Improved Position Loops

HEPI-HAM3 position loops were designed/tested earlier this week. First performance spectra were posted in LHO aLog #7871.

A new set of controllers was designed today. The goal was to minimize gain peaking, while improving UUG.

HEPI is over constrained. Hence, we do not want to push at DC on all of the 8 DOF. Controllers for HP (Horizontal Pringle mode) and VP (Vertical Pringle mode) were limited to simple notches with no gain at DC.

New performance spectra were taken (purple) and compared to previous performance (blue) and no control (red).

Non-image files attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 15:09, Friday 27 September 2013 (7891)

Filters are commited in the svn:
/ligo/svncommon/SeiSVN/seismic/HEPI/H1/HAM3/Filters/Matlab/Isolation_Filters/H1_HEPI_HAM3_Isolation_Filters_Tuning_09_26_13_HP.m       -r7595

H1 General
andres.ramirez@LIGO.ORG - posted 11:55, Friday 27 September 2013 (7889)
Ops shift Summary (AM)
Moving  SUS/SEI field cabling from teststand to BSC9 at End X - Filiberto
Baffle work at the LVEA – Thomas Vo
PSL work – Cheryl
Taking a quick check to the suspensions  at End X – Jeff B.
Work on h1lsc and h1iscex front end models n – Chris W.
H1 ISC
kiwamu.izumi@LIGO.ORG - posted 12:34, Thursday 26 September 2013 - last comment - 11:43, Saturday 28 September 2013(7879)
reflectivity measurement of REFL in-vacuum 90% beam splitter

[Pablo and Kiwamu]

 We have measured the reflectivity of another 2" P-polarizing beam splitter (E040512-B3 SN: I0822-07) for S-polarization this morning at the OSB optics lab.
The results are :
    HR reflectivity R = 92.5 % for S-pol @ 1064 nm, 45 deg
    AR reflectivity R =  2.8 % for S-pol @ 1064 nm, 45 deg


Background :

Even though we already installed a 90% S-polarizing beam splitter on HAM1, we still thinks that this 90% might not be big enough to attenuate the reflection beam to avoid damaging the detectors. One way to increase the safety margin is to simple replace this 90% BS by one with a higher reflectivity. Because we have 90% P-pol BS in hand we simply wanted to try measuring the reflectivity with a S-polarizing beam.

Setup:

Same as the previous measurement (see alog #7817).
 

Comments related to this report
kiwamu.izumi@LIGO.ORG - 11:43, Saturday 28 September 2013 (7903)

This measurement is now archived in DCC:

https://dcc.ligo.org/LIGO-E040512.