Displaying reports 79301-79320 of 86521.Go to page Start 3962 3963 3964 3965 3966 3967 3968 3969 3970 End
Reports until 17:06, Thursday 15 August 2013
H1 ISC
stefan.ballmer@LIGO.ORG - posted 17:06, Thursday 15 August 2013 (7452)
ASC model work
I re-imported the l1asc.mdl to Hanford and compiled it.

Changes:
 - L1->H1 globally
 - l1 to h1 globally
 - LLO to LHO globally
 - replaced the PSL IPC with a simple epics input (temporary, due to missing hardware).

Recompiling and running worked, but revealed a bug in the RTCDS code:
 - the kill script got stuck in the burt safe command. Temporary fix: replace grep h1asc with grep "h1asc "

Next I will start adding the inital alignment stuff for the arms.
LHO General
patrick.thomas@LIGO.ORG - posted 16:23, Thursday 15 August 2013 (7451)
restarted dust monitor IOCs for both end stations
Had to restart these to restore communications.
H1 General
hernan.daveloza@LIGO.ORG - posted 16:00, Thursday 15 August 2013 (7450)
Ops Day Summary

- Works at EY
    Apollo: ask Bubba
    Richard ask him

- Works at EX
    Keita (ISI) getting ready for SUS

- Works at LVEA
    Michael, Hugh: ... some HAM are offset by several mm and that can cause problems with the mode matching ... (talk to them)
    Arnaud TF


- Michael gave a tour to a PNNL group
- PRAXAIR came around 9:30AM, left around 11:40AM
- (14:20) John and a group of contractors went to the roof
- Mark Hankel and the fire department were checking fire extinguishers
- DUST at Bake-Out was very high (15000 for 300nm, 5000 for 500nm) today. Patrick told me that Greg was working inside. John is aware of the situation.

LHO General
patrick.thomas@LIGO.ORG - posted 15:41, Thursday 15 August 2013 (7449)
plots of dust counts
Attached are plots of dust counts requested from 4 PM August 13 to 4 PM August 14.
Non-image files attached to this report
H1 ISC
stefan.ballmer@LIGO.ORG - posted 12:58, Thursday 15 August 2013 (7448)
ISCT1 persicope & acoustic mitigation

Terra Hardwick, Vinny Roma, Robert, Stefan)

We hat 2 accelerometers mounted on the two pryramid-shaped periscopes on ISCT1 that are in the ALS beam path.

Below are plots of the velocity spectra for each accelerometer, as well as for the difference. No separate calibration was applied - we simply took the difference of the raw data. However, as can be seen from plot 3, the two accelerometers seem to be matched to better than 1%.

Plot 1 shows the of periscope 1 vs periscope 2 spectra. Note that the highest peak is just below 70Hz, but common in both periscopes - the two periscopes seem to be locked together. The peak just above 70Hz however is the dominant one in the difference spectrum. It is also the one that shows up in the HIFOY spectra.

Plot 2 shows the two accelerometers mounted on the same periscope (the middle one that carries the green beam from x and y arm). The accelerometers were mounted at a slightly different height, about a 3 inch appart, corresponding to a setup with different mirrors mounted on top of the periscope. Note that we get about a factor of 10 suppression.

Plot 3 again has both accelerometers mounted on the middle periscope, but at the same height, i.e. simulating a situation with all three beams hitting the same top periscope mirror. The suppression factor is now too good to believe. This suggests that if possible, using the same top mirror for all 3 beams would be beneficial.

One warning about the accelerometer mounting: they were attached directly to the periscope. having two different mirror mounts can make the situation slightly worse. This again would suggest that using a single top mirror would help.

All plorts are calibrated in m/sec/rtHz.


 

Images attached to this report
H1 AOS
keita.kawabe@LIGO.ORG - posted 17:46, Wednesday 14 August 2013 (7445)
Attaching TMS ISC cables to the top mass

Spent an hour to play with the cable clamp bracket, and improved on Cheryl's idea to use metal clamps with kapton tubings (first picture).

One D1000921 (thicker, for pico, beam diverters) and one D1000921 (thinner, for QPDs) are wrapped with kapton tubing and clamped using a pair of metal hold down clamps (second picture). Two such pairs are made (third picture) and they sit next to each other. I also tried making thin-thin and thick-thick pair, but it didn't work well. Thin--thin is easy to rotate between the clamps and goes to "bad" position in the first picture easily, losing any clamping pressure.

Extra care should be taken to align things properly, and the number of washers should be chosen such that everything is snug but not too tight when the bolts are tightened. When you pull the cable it should slide inside the tubing, but it should not slide on its own.

With too few washers, it's easy to put too much pressure on the cables which promotes short circuits as the soft teflon insulation is broken. With too many washers, even if it feels OK at first, it is easy to rotate the cables in the clamps so the cable pair goes to "this is bad" position in the first attachment and the thinner cable becomes loose.

Note that I'm abusing a 1/4-20 aluminum nut as a poor man's washer. This is because the normal washers we have is too big and interferes with the curved  part of the metal clamps, and we have a limited supply of smaller washers. It's working OK, when I tightened the bolts there's no loose thing.

This is just a test run by one person using the wrong end of the cables for ease of access, we'll do the real run tomorrow.

Images attached to this report
H1 DAQ
david.barker@LIGO.ORG - posted 17:13, Wednesday 14 August 2013 (7444)
DAQ back after disk repair work

Dan worked on the MSR SATABOY and its associated Sun/Oracle server. He upgraded all firmware and moved hardware around. The disk system is back online and no data was lost.

We have restarted h1fw1 and h1nds1 and frames are being written again. The data gap on h1fw0 is

aug 13 23:31

aug 14 17:04

This afternoon Jim moved the default NDS from h1nds1 to h1nds0. We will keep it this way overnight and swap back tomorrow if h1fw1 continues to be stable.

LHO General
cheryl.vorvick@LIGO.ORG - posted 16:13, Wednesday 14 August 2013 (7443)
OPS Summary:

- H2 enclosure on/off laser hazard today

- diode room dust monitor checked

- dust monitors restarted

- disk failure on FW1

- H1 PSL ENV channels fixed
H1 CDS
james.batch@LIGO.ORG - posted 16:06, Wednesday 14 August 2013 (7442)
Changed default NDS server changed to h1nds0
The default NDS server has been changed to h1nds0 while frame writer 1 is down.  This takes effect for any new shell or matlab session started after 16:03 PDT today.

H1 INS
jodi.fauver@LIGO.ORG - posted 15:21, Wednesday 14 August 2013 (7441)
ETMY Install Prep
The work platform assembly was completed by the Apollo crew. They also transported the balance of the FFUs for the chamber cleanroom from the OSB High Bay to Y end: the FFUs are currently in the outer bay. Hand rails got wiped down and moved into the VEA. Scott worked with Hugh on HAM6 this afternoon.

I spent some time working on the "curtain problem":we have lots of curtains but very few of the correct length for a chamber cleanroom. I think I have a path forward but would like to discuss it with Bubba first.
H1 SEI
vincent.lhuillier@LIGO.ORG - posted 14:13, Wednesday 14 August 2013 (7440)
L4C cable swap - HEPI - BSC1

I have temporarily swapped the (H-V) L4C cables of the HEPI in corner 2 and 4.

H1 SUS
arnaud.pele@LIGO.ORG - posted 12:20, Wednesday 14 August 2013 (7432)
sus matlab updates

Several updates on matlab scripts modifications I recently made during data processing

1- generate_QUAD_Model_Production.m. Produces a matlab model for damped and undamped quad suspension  (/ligo/svncommon/SusSVN/sus/trunk/QUAD/Common/MatlabTools/QuadModel_Production)

The filter file used in the script to compute the modeled closed loop was out of date from the filters installed on our quads, so I updated it with the most recent damping filters : "dampingfilters_QUAD_2013-06-14.mat" living in /ligo/svncommon/SusSVN/sus/trunk/QUAD/Common/FilterDesign/MatFiles

design_damping_QUAD_20130614.m (that creates dampingfilters_QUAD_2013-06-14.mat) won't work if susTag is set to "L1:SUS-ETMY" since there's no 'etmy' variable in the ISI2SUS_projection_file.mat

2-plotquad_matlabtfs.m. Processes the measurements and plots them against our model (/ligo/svncommon/SusSVN/sus/trunk/QUAD/Common/MatlabTools)

The option of plotting the measurements with the damping active against the closed loop model has been added to the script, with a new flag "isDamped=true/false" at the beginning of the script

3-Matlab_TFs.m. Launches automated transfer functions (/ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools/SchroederPhaseTools)

The script has been modified in order to take transfer functions on several suspensions at the same time. The drive signal txt file used by awgstream to send an excitation is now suspension specific, as well as the diary file. Those two files were creating conflicts and error messages when two similar tf scripts were beeing run at the same time.

Also, in order to make the script easier to read, and for future debugging purposes, I moved the sensor and actuator channel list out of the code, and packed it in a subfunction "generate_channel_list.m" located in /ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools/SchroederPhaseTools/

4-collect_schroeder_TF_v9DQ_sma.m. Subfunction of Matlab_TFs.m. It creates a schroeder phased drive signal

From now, when Matlab_TFs.m is ran, the one time excitation signal, as well as the full drive signal will be displayed and plotted, as a function of time before the signal is sent to the DAC.

LHO General
patrick.thomas@LIGO.ORG - posted 11:37, Wednesday 14 August 2013 (7439)
h0dustdr
Yesterday this IOC lost communication to the dust monitor in the diode room. I restarted it today and it has reconnected. I suspect the Comtrol serial to Ethernet converter (10.105.0.100) is on the network switch that was remounted yesterday.
H1 DAQ
david.barker@LIGO.ORG - posted 11:25, Wednesday 14 August 2013 (7438)
h1fw1 disk system failure

The SATABOY QFS disk system used by h1fw1 and h1nds1 suffered a failure at 23:31 last night local time. I have turned off h1fw1 while we investigate the problem.

Please use h1nds0 for archived data until this problem has been resolved. h1nds1 will only support real time data.

LHO General
patrick.thomas@LIGO.ORG - posted 21:47, Tuesday 13 August 2013 (7436)
plots of dust counts
Attached are plots of dust counts requested from 4 PM August 12 to 4 PM August 13.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 21:43, Tuesday 13 August 2013 (7435)
plots of dust counts
Attached are plots of dust counts requested from 4 PM August 11 to 4 PM August 12.
Non-image files attached to this report
H1 ISC
stefan.ballmer@LIGO.ORG - posted 21:23, Tuesday 13 August 2013 - last comment - 19:49, Wednesday 14 August 2013(7434)
Draft for green arm initial alignment system
Out of the 4 DoF (arm optical axis pos and angle, green input beam pos and angle, 2x for pitch and yaw not counted), 3 DoF will likely need a frequent initial alignment - the input beam position at the ETM is the one DoF that remains fixed.

Below is a short description of the suggested alignment loops. Attached is a draft RTCDS model block for e.g. X-arm pitch (we need 4 of them for X/Y P/Y).

Signals to be demodulated:
L: cavity PDH length error signal (green)
R: cavity reflected power (green)
T: cavity transmitted power (green)

Actuation basis (in rad):
(ITM, ETM, TMS)

g-factors:
g1=1-L/R1;
R1= RoC of ITM
g2=1-L/R2;
R2= RoC of ETM

Dither drive frequencies:
f1: ITM dither frequency
fT: TMS dither frequency

Control loops:
1) Fix ITM actuation node
L --->x ---> CTRL_FILT -----> (g1,1,1)
      ^
      |
      f1

Remark:
- Actuation at 1.65-2Hz or above 4Hz seems possible in pitch
- Pitch centering offset at 1.7Hz: ~2.3mm (slightly freq. dependent)
- Pitch centering offset above 4Hz: ~4.7mm
- Could provide a slight additional length drive to compensate this offset
- no such issues for yaw
- Actuation leaves the following quantities unchanged:
  - arm axis position on ETM
  - angle between arm axis and input beam


2) Input beam to arm axis angle overlap at ETM focal point
R or T ---> x ---> CTRL_FILT -----> (1,g2,g2)
            ^
            |
            f1
Remark:
- Actuation leaves the following quantities unchanged:
  - arm axis position on ITM
  - arm axis to input beam separation at ETM focal point
  - input beam position at ETM (trivial)

3) Input beam to arm axis angle overlap at ETM
R or T ----> x ---> CTRL_FILT ----->  (0,0,1)
             ^
             |
             fT
Remark:
- Actuation leaves the following quantities unchanged:
  - arm axis position and angle
  - input beam position at ETM (trivial)

Alternatives:
- GigE camera centering on ITM (instead of 1)
- ETM dither possible, but due to the steep drop-off of the Quad actuation, I expect reasonable drive amplitudes (producing a decent dip in power buildup) to only be possible at very low frequencies. As a result, since the dither frequency separation dictates the achievable bandwidth, it might be difficult to run all dither loops at the same time.

General Remarks:
- The dither drive is done in the optics basis, because any other basis would require significant attention to the relative phase of different actuation functions.
- To be able to run the loops in sequence, an orthogonal actuation function is desirable.
- repeat procedure of X- and Y -arm, pitch and yaw
- Once both arms are aligned, turn this feed-back off.


Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 19:49, Wednesday 14 August 2013 (7446)
(Sheila, Stefan)

Looking at the trend data (mostly OSEMS) of PR3 PR2 and PRM, it looks like they can drift by up to about 10urad in both pitch and yaw over the course of several days.

We were curious what that means for initial alignment requirements. So we put together a ray transfer matrix model based on LIGO-T0900043: “Optical Layout and Parameters for the Advanced LIGO Cavities”. With that we looked at how much the beam spot on the ETMs would move given the 10urad drift (the factors of 2 are due to reflection on the mirror):

PR3: 2x 4.0 mm/urad * 10urad ~ 80mm (compare to beam spot size of w=62mm - motion too big)
PR2: 2x 0.44mm/urad * 10urad ~  9mm
PRM:      7 um/urad * 10urad ~  0.07mm (tiny!)

SO:
- PRM will be just fine, and won't need any daily realignment.
- PR2 seems to be borderline - probably good enough for locking, but might need the occasional tweak.
- PR3 (&BS) will definitely need an alignment. The logical place for this would be during the green locking - we might want to add green QPDs on ISCT1.


Similar conclusions will hold for the SRC (once its installed). Here an initial tweak-up of SR3 can be done with the AS_DC QUAD on HAM6.
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:00, Tuesday 13 August 2013 - last comment - 09:33, Wednesday 14 August 2013(7430)
WHAM6 Floating ISI Optical Table Leveled/Elevated w/HEPI
Set the HAM6 Optical Table to -220.1mm Gz per E1000403 & D1100398.  Used Mon 802.

The table started about 1 to 1.5mm low.  Finished at average -220.3 +-0.2mm; still need to do horizontal alignment so this is close enough on the vertical for now.
Comments related to this report
hugh.radkins@LIGO.ORG - 09:33, Wednesday 14 August 2013 (7437)
We locked the ISI to do this measurement & adjustment.  It remains locked at this time.
LHO VE
kyle.ryan@LIGO.ORG - posted 16:21, Thursday 08 August 2013 - last comment - 11:38, Thursday 15 August 2013(7384)
GV6 leak fixed
Kyle, Gerardo 

Today, after John had notified Rai of our intent, we applied a few drops of Vacseal (SPI Supplies, Space Environment Laboratories, original formula 0502-AB) to the top of the previously identified leaking 1.33 CFF on GV6 (North gate annulus port).  The leak seams to be fixed now.  
Comments related to this report
john.worden@LIGO.ORG - 11:38, Thursday 15 August 2013 (7447)

Pressure of Y1 module at the LVEA and at the Mid station after the fix.

The leak appears to be stable at a much reduced rate. Perhaps fixed. At an opportune time we will spray helium again.

Images attached to this comment
Displaying reports 79301-79320 of 86521.Go to page Start 3962 3963 3964 3965 3966 3967 3968 3969 3970 End