hugo.paris@LIGO.ORG - posted 18:09, Tuesday 23 July 2013 - last comment - 18:14, Tuesday 23 July 2013(7189)
HAM2 HAM3 HEPI Release - IMC Alignment Reestablished

HAM2 and HAM3 HEPI were released today.

 

Raw IPS readouts were recorded prior to release. The following offests were set in the actuation path to reestablish alignment, based on the IPS readouts:

  OFFSETS (cnt)
  HAM2 HAM3
H1 370 900
H2 800 200
H3 -600 350
H4 -400 -650
V1 450 300
V2 460 -650
V3 1050 200
V4 900 1250

 

 

IPS readouts were recorded after reestablishing alignment:

 

  NEW READOUTS (cnt)
  HAM2 HAM3
H1 1438.7 6664
H2 957.61 -4089.2
H3 2089.2 9159.3
H4 -1238.1 -2252.5
V1 -2796.8 2709.1
V2 -608.92 -6394.7
V3 1029.5 2257
V4 -2862.8 -9434.1

 

 

The Before/After difference in IPS readout is shown below:

 

  BEFORE/AFTER DIFFERENCE (cnt)
  HAM2 HAM3
H1 107.6 146.6
H2 0.11 588.7
H3 68.2 169.1
H4 65.5 104.3
V1 54.1 155.1
V2 97.09 32.3
V3 4.5 144.5
V4 20.1 38.3

 

 

The remaining shift in alignment induced by unlocking HAM2 and HAM3 HEPI is less than 0.25mils (147 counts on the IPS), on each pier, after reestablishing the alignent with offsets on the actuation path.

Comments related to this report
hugo.paris@LIGO.ORG - 18:14, Tuesday 23 July 2013 (7190)

Note: Isolation loops tripped only on HAM2-ISI. They are back ON now.

The DC part of those loops (CPS Biases) remain unchanged from prior to HEPI release, hence ensuring consistent alignment of the platforms.

LHO VE
kyle.ryan@LIGO.ORG - posted 17:05, Tuesday 23 July 2013 (7188)
Pumping spool annulus at X-mid
Vented spool (in place of iLIGO BSC5) annuli -> No inner O-ring leakage -> removed temporary O-ring valves from bolted joint pump ports and connected permanent ion pump piping -> pumping annulus system with aux. cart overnight
H1 ISC
jeffrey.kissel@LIGO.ORG - posted 17:02, Tuesday 23 July 2013 - last comment - 18:44, Tuesday 23 July 2013(7187)
ALS Calibrated Cavity Length Channel
For future reference,

The calibrated channel representing the frequency of the green laser (in [Hz]) is
H1:ALS-Y_REFL_CTRL_OUT_DQ


This can be converted to the length of the arm cavity using the free spectral range,
Cavity Length = lambda * (L / c) * H1:ALS-Y_REFL_CTRL_OUT_DQ
Comments related to this report
stefan.ballmer@LIGO.ORG - 18:44, Tuesday 23 July 2013 (7192)
Careful: Since we implemented a bypass path from the PDH board to the laser, there is 22dB less signal on H1:ALSY_REFL_CTRL_OUT_DQ (the fast slider on the Sigg board is at -22dB, since this signal is now goint to the laser).

This means that the calibration has to be corrected by these 22dB. See elog 6900.
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:03, Tuesday 23 July 2013 (7186)
WHAM2 & 3 HEPIs Unlocked *** Caution ***
GregG unlocked these suspensions and they are now floating again after a long hiatus of sequestration.  Please regard the "Unlocked" signs and be mindful of any mechanical shorts against the floating elements.  If you drop a screw or other smaller item, don't just forget about it as it may short the suspension too.
Please avoid stepping on the Crossbeams if you don't wish to hear about it from BetsyW!
H1 General
andres.ramirez@LIGO.ORG - posted 16:00, Tuesday 23 July 2013 (7185)
Ops shift Summary
Bubba craning small loads over tube (consulted with Worden)
Lots of CDS work for Maintenance…
Paradise Water on site.
Arnaud started running Transfer Functions on HAM2/HAM3
Work on HAM 2 - Hugh
H1 CDS
david.barker@LIGO.ORG - posted 15:56, Tuesday 23 July 2013 (7184)
CDS Maintenance summary

today we restarted the DAQ about 16 times. I'll abbreviate this as DR.

First due to the restart of h1iscey the new h1pemey model was loaded. A DR was needed to resync the DAQ.

I created a new h1peml0 model as per Roberts latest changes. I restarted h1peml0 and did a DR.

Bad DUST channels in the DAQ. We found that some of the DUST EPICS channels went bad in the frame starting 7/9 when I added EX to the DAQ. To verify this I first took out all the ECAT channels from the EDCU (DR), and then I removed all the EX systems from the DAQ (DR).

The number of EDCU channels changed from 195,003 to 191,506 to 173,744. At the lowest number the DUST channels became good again.

To figure out what number of channels would break it again I put the ECAT channels back in (DR) and then h1susex (DR). The number of channels went to from 177,241 to 185,360 at which point some DUST channels went back to not as many. Later I put the system back to the full 195,007 (DR) and the full set of bad DUST channels came back.

For more info we moved DUST channels around in the H0EDCU_DUST.ini (DR) and found that the position within the file determined which ones were bad (for e.g. 3rd and 5th slots were bad). We moved the order of the H0EDCU_DUST.ini in the master file (DR)(did not change anything) and removed the H0EDCU_WEATHER.ini from the DAQ (DR)(did not change anything).

Hugo found ADC noise on the ISI HAM6 system. We power cycled the h1seih16 front end computer and the IO Chassis with no success. I removed the ADC cable and the noise went away. At this point I handed the problem over to Richard and Filiburto.

The latest Beckhoff ini files were ingested into the DAQ (DR)

A reminder that all our fast DAQ channels show up in RED due to the incorrect dataValid flag. This will be fixed next week when we upgrade to RCG2.7

H1 SUS
jeffrey.kissel@LIGO.ORG - posted 15:45, Tuesday 23 July 2013 (7183)
Re-installed H1:SUS-BS CART2EUL Matrices
J. Kissel, A. Pele

For some reason the CART2EUL Matrices had been lost over some reboot / burt restore cycle. We've re-installed them, and captured + committed a new safe.snap. 

Install instructions:

]$ matlab -nosplash -nojvm
>> cd /opt/rtcds/userapps/release/isc/common/projections/
>> load ISI2SUS_projection_file
>> fill_matrix_values('H1:SUS-BS_M1_CART2EUL',ISI2SUSprojections.h1.bs.CART2EUL)
>> fill_matrix_values('H1:SUS-BS_M1_EUL2CART',ISI2SUSprojections.h1.bs.EUL2CART)
>> cd /ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools/
>> save_safe_snap('H1','BS')
>> exit
]$ svn commit -m "New safe.snap file for H1:BS" /opt/rtcds/userapps/release/sus/h1/burtfiles/h1susbs_safe.snap

H1 IOO
kiwamu.izumi@LIGO.ORG - posted 14:04, Tuesday 23 July 2013 - last comment - 18:43, Tuesday 23 July 2013(7181)
IMC demodulation phase rotated again, temporarily fixed

The demodulation phase of the IMC rotated by approximately 90 degrees. This is the third time to see this kind of phase rotation in the IMC. Very strange.

Temporary fix:

Temporarily I switched the signal from the I to Q signal by changing the actual cabling at the corner field rack and flipped the control sign at H1:IMC-REFL_SERVO_IN1POL by toggling the switch in the upper left of the IMC board screen. The IMC is now locking and should serve as an interferometric monitor for the sus and seismic people. The WFS loops are currently disabled by setting H1:IMC-WFS_GAIN to be zero to avoid a meaningless control. It seems the IMC started dropping its lock after Roberts and his company entered the PSL enclosure. The temperature transient somehow caused it ? It is unclear.

By the way the attached is a picture of the current I-mon and Q-mon signals in a X-Y projection. The I-mon is x-axis and Q-mon is y-axis. You can see a line almost in parallel to the y-axis indicating that the IMC length signal shows up mostly in the Q-phase.

Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 18:43, Tuesday 23 July 2013 (7191)

To make it clearer, I flipped H1:IMC-REFL_SERVO_IN1POL to be minus (a.k.a. 1).

H1 SEI
hugo.paris@LIGO.ORG - posted 13:42, Tuesday 23 July 2013 - last comment - 14:22, Tuesday 23 July 2013(7180)
HAM2 and HAM3 SEI Alignments

Prior to releasing HAM2 and HAM3 HEPIs, we recorded the readouts on the postion sensors of the ISIs, and HEPIs, of the input mode cleaner.

 

HAM2 ISI, raw CPS readouts, in counts

H1            -3388.2      

H2            -2936.6      

H3            -504.78      

V1           -138.78      

V2            -966.74      

V3            -737.11      

 

HAM3 ISI, raw CPS readouts, in counts

 H1           -526.93       

 H2           266.35         

 H3           -175.73        

 V1           -1405.1        

 V2           -1102.9        

 V3           -560.2          

 

HAM1 HEPI, raw IPS readouts, in counts

H1            8075.8         

H2            -2940.6       

H3            -8136.2       

H4            -1306.2       

V1            182.27         

V2            4545.2         

V3            -1657.4        

V4            -1572.6        

 

HAM2 HEPI, raw IPS readouts, in counts

H1            1331.1         

H2            957.72         

H3            2157.4         

 H4           -1303.6       

 V1           -2742.7       

 V2           -511.83        

 V3           1034             

 V4           -2882.9       

 

HAM3 HEPI, raw IPS readouts, in counts

H1            6517.4         

H2            -4677.9       

H3            9328.4        

H4            -2148.2       

V1            2864.2        

V2            -6362.4       

V3            2112.5         

V4            -9395.8       

Comments related to this report
hugo.paris@LIGO.ORG - 14:22, Tuesday 23 July 2013 (7182)

I made, and used, a script to retrevieve all this information at once:

/ligo/svncommon/SeiSVN/seismic/Common/MatlabTools/IMC_ISI_HEPI_position.m

It is commited under the SVN (r7458)

H1 SUS
jeffrey.kissel@LIGO.ORG - posted 13:10, Tuesday 23 July 2013 (7178)
HAM2 and HAM3 SUS Alignments
In preparation for unlocking HAM2 and HAM3 HEPIs, here are the alignments and static positions (as measured by the OSEMs) before unlocking, for reference.

HAM2 (* indicates alignment offsets are OFF currently, because Arnaud is measuring some lower stage transfer functions)

               MC1     MC3     PR3     PRM
P  [urad]     +312    +261    -148*   -770*    
Y  [urad]     -968   -1081     124*  -1200* 

M1T1 [ct]    12247   15407   11976    12430
M1T2 [ct]    13061   15166   16039    14890
M1T3 [ct]    13600   14370   15890    13874
M1LF [ct]    15975   15170   10659    11306
M1RT [ct]     9539    7682   10424    11068
M1SD [ct]    11831   11578   13022    12813
M2UL [ct]    16070   18355    7212    17435
M2LL [ct]    20649   14340   10466     2510
M2UR [ct]     7266   12539   10768    17270
M2LR [ct]    14008    9908    8883     2492
M3UL [ct]    14414   15096    7667    16049 
M3LL [ct]    21812   15740   10337     3730
M3UR [ct]    10138   11881   10654    14385
M3LR [ct]    18289    7221    7899     4566


HAM3

             MC2       PR2
P  [urad]   +434      +716*
Y  [urad]   +244      +120*

M1T1 [ct]  13708     14293
M1T2 [ct]  12670     12692
M1T3 [ct]  13585     12476
M1LF [ct]  12330     13635
M1RT [ct]  13636     14635
M1SD [ct]  14254     13127
M2UL [ct]  11830     14296
M2LL [ct]   9944     15369
M2UR [ct]  12493     12516 
M2LR [ct]  13180     12042
M3UL [ct]  11333     12223
M3LL [ct]   9213     14342
M3UR [ct]  11356      8504
M3LR [ct]   8200     14608
H1 AOS
thomas.vo@LIGO.ORG - posted 13:05, Tuesday 23 July 2013 (7179)
Beamsplitter Optical Lever Alignment
The BS optical lever has been realigned with HEPI unlocked (and untripped), ISI damped  and SUS damped.  This is also with a verbal OK from ISC saying that the current alignment of the optic is good.
H1 ISC
james.batch@LIGO.ORG - posted 08:26, Tuesday 23 July 2013 (7174)
Power cycle h1iscey
The h1iscey front-end computer lost contact with the I/O chassis Monday evening, it's unknown why.  Tuesday morning I disconnected the computer from the dolphin network, then powered off computer.  On power up, the I/O chassis connected OK, and the models started.  Note that the H1PEMEY model has a 0x2000 DAQ status, indicating that most likely the H1PEMEY.ini file has changed.  

The 0x2000 status will require a DAQ restart to clear.
H1 AOS
thomas.vo@LIGO.ORG - posted 22:57, Monday 22 July 2013 (7172)
Optical Lever Maintainence and Realignment
Emily, Tristan, Terra, Thomas

ITMY optical lever has been showing lots of drift in yaw for the past few weeks (~ 1 urad/1 min), today we were able to close the gate valves and shutter the PSL so that we can open the transmitter and receiver units.  At first we thought a few screws were loose and they were tightened, but that didn't help.  Then we strain-relieved the fiber optic feeding into the transmitter but that also did not fix this drift problem.

 I found that the alignment was sensitive to me pushing on a nearby cable tray that was connected to a conduit that was leaning on a copper pipe that the optical fiber was laying on (picture attached). The optical fiber was being tugged on by the copper pipe as well as the conduit and cable tray so we isolated the fiber to decouple the connection. After the fix, the drift was much better, about +/- 1 urad for the course of a few hours, this will hopefully be a good set up to take spectra and long term testing.

Also, we re-centered the PR3 and BS optical levers and will continue to recenter as needed for testing by SEI and SUS.
Images attached to this report
LHO General
gerardo.moreno@LIGO.ORG - posted 20:34, Monday 22 July 2013 (7171)
Ops Shift Summary

Today's acitvities reported to the operator:
- Kyle R to LVEA to soft close GV5.
- Corey G and Keita K, working at End-X, TMS related work.
- Thomas V to work on ITM-Y OpLev, maintenance. Shutter between PSL enclosure and HAM01 was locked while work was done.
- Scott S, Mitch R and Lisa A,  AOS/SLC Team to LVEA, End-X ACB build up.
- Betsy W and Travis S, End-X SUS work.
- Kiwamu I, to LVEA, check ISC table contents.
- Pablo D, Colin S and Craig C, work in the H2 PSL enclosure.
- Patrick T to both End stations, dust monitor work.
- Thomas V to remove lock from light pipe.
- Kyle R, to open GV5.

LHO General
patrick.thomas@LIGO.ORG - posted 19:49, Monday 22 July 2013 - last comment - 12:44, Wednesday 31 July 2013(7170)
dust monitors in LVEA
The dust monitors in the LVEA are NOT currently being recorded. It appears swapping the dust monitor in the H1 PSL enclosure has broken the communications.
Comments related to this report
patrick.thomas@LIGO.ORG - 09:45, Tuesday 23 July 2013 (7177)
Upon startup the IOC communicates correctly with each dust monitor until it gets to location 16 (the one that was swapped yesterday). After this it starts reporting back errors of the form:

Error: ../commands.c: 49: Sent command � not echoed
Received ?
patrick.thomas@LIGO.ORG - 10:54, Wednesday 24 July 2013 (7205)
I powercycled the Comtrol this morning. It worked after location 16 for a little while, but the error has returned.
patrick.thomas@LIGO.ORG - 17:58, Wednesday 24 July 2013 (7210)
Robert says he swapped the dust monitor in the H1 PSL laser enclosure.

First one dust monitor was disconnected from the breakout box outside the entire H1 PSL enclosure. If I recall correctly, the dust monitor at location 16 was then still found by the IOC. The communication errors persisted. The first dust monitor was plugged back in and the other one disconnected. The IOC still found the dust monitor at location 16, but the communication errors went away. The dust monitor at location 16 reported calibration errors.

It may be that the wrong dust monitor was swapped, leading to two set at the same location number, but this would not explain why the communication errors persisted after the first one was disconnected.

As it stands, one of the dust monitors in the H1 PSL enclosure is disconnected. The dust monitor at location 16 is reporting calibration errors. I am not sure where the dust monitor at location 16 is. The dust monitor at location 10 is not found by the IOC. The remainder of the dust monitors in the LVEA are running again.
patrick.thomas@LIGO.ORG - 12:44, Wednesday 31 July 2013 (7302)
Sheila swapped the dust monitor in the anteroom with one programmed at location 10. The one she removed from the anteroom is labeled 'H'. It had no charge left in the battery when I got it.

There was no change in the status. The dust monitor at location 10 is still unseen, and the dust monitor at location 16 is still giving calibration errors.

This leads me to believe that:
The dust monitor at location 16 is in the laser room and has calibration errors.
The dust monitor at location 10 is in the anteroom and is unplugged at the breakout box outside the enclosure.
H1 PSL
robert.schofield@LIGO.ORG - posted 19:44, Monday 22 July 2013 (7169)
PSL activities

Today we installed 2 more accelerometers on the PSL table, one by where the water enters the high-power amplifier and the other by the PMC. We also removed the cover from the PMC. In addition we switched out the dust monitor which has been giving a calibration error message for some time (the 300 and 500 nm cutoffs may not be well calibrated).  And we put up some signage related to switching between commissioning and science mode.

H1 SEI
jess.mciver@LIGO.ORG - posted 16:30, Monday 22 July 2013 - last comment - 16:21, Monday 29 July 2013(7159)
6.8 Hz line found in top stage ITMY BOSEMs traced to stage 2 of the ISI

Daniel Halbe, Jess McIver

Daniel has shown a strong, persistent line at 6.8 Hz in all DOFs of the top stage BOSEMs of the ITMY since at least June 12. 

As a follow up to his study, I looked for this line in the ITMY ISI and found it in stage 2: very sharply in RX, strongly in RY, somewhat fainter in Z, and much quieter in X, Y, and RZ. 

The line is not seen in any DOF in stage 1, looking at the T240s. 

Normalized spectrograms of representative DOFs are attached. 

Images attached to this report
Comments related to this report
daniel.halbe@LIGO.ORG - 02:28, Tuesday 23 July 2013 (7173)
I have discovered a line very similar to this at Livingston and it occurs at 7 Hz.  This line is found in Roll (very strongly) and not as strong in pitch.  It appears to only show up in those two degrees of freedom and only in the top SUS mass.  It does not show up in the ISIWIT channels or the top stage of the ISI.  Also it does not show up in any of the other suspension stages.
Images attached to this comment
jess.mciver@LIGO.ORG - 16:21, Monday 29 July 2013 (7273)

I looked at spectrograms, time series, and ASDs for the CPS sensors on ST2 of the H1 ITMY ISI in all global degrees of freedom, but saw no evidence for a line at 6.8 Hz. An ASD of each CPS DOF during this time is attached in .fig form. 

Non-image files attached to this comment
H1 General
robert.schofield@LIGO.ORG - posted 18:46, Sunday 21 July 2013 - last comment - 08:43, Tuesday 23 July 2013(7150)
Vibration coupling to HIFO-Y

Summary: The HIFO-Y feature at 70 Hz is produced by both ALS periscopes on ISCT1. The features below 1 Hz are coherent with ground motion and OSEM sensors. We did not identify the dominant source of noise between 0.8 and 2 Hz, though this band contributes little to the HIFO-Y RMS. We may be able to reduce the RMS by using cylindrical periscopes that have resonant frequencies closer to 250 Hz, but we will also likely get a free factor of about two reduction in RMS (in the 60-80 Hz band) after noisy installation activities cease.

Vibration coupling to HIFO-Y was reduced by establishing a science mode and a commissioning mode for PSL air handling (Link). There remain two frequency bands that contribute significantly to the HIFO-Y RMS, 60-80 Hz, and 0.3-0.7 Hz.

Figure 1 shows spectra for the PEM sensors that we recently installed whose signals have the highest coherence with the HIFO-Y signal above 1 Hz. The PSL was operating in science mode. The accelerometer that we mounted temporarily on one of the two similar ALS telescopes on ISCT1 (red trace), the one that carries infrared light, has high coherence with and similar shape to the 50-100 Hz band noise in HIFO-Y (red and black traces). Further excitation tests on the ISCT1 table confirmed that the 70 Hz feature is associated with the lowest resonant frequencies of both ALS periscopes. Neither the green nor the infrared periscope appears to dominate, and I could find no particular source of, e.g., backscattering noise. It may be that the noise is associated with the differential motion of the two periscopes in the locked path.

The other coherence features in the spectrum are, at about 180 Hz, one of the higher-Q resonances of the PSL periscope – perhaps driven by vibrations at the 60 Hz harmonic. These 180 Hz vibrations may be smaller after installation, and if they are not suffieciently smaller, we may be able to damp at this frequency. The 12 and 13 Hz coherence regions are produced by table sway resonances of ISCT1. I am less certain about the feature between 5 and 6 Hz, but there is a building resonance at that frequency excited by wind. The seismometers, some distance from the PSL and ISCT1, also show strong coherence with HIFO-Y at 5.5 Hz, supporting the building resonance interpretation.

Coherences with features in the low frequency region are shown in Figure 2. Seismometer and OSEM signals have high coherence with the HIFO-Y signal, except in the band between 0.8 and 2 Hz. We did not find the source of noise in this region.

It may be useful for the DetChar group to look for coherence in this 0.8-2 Hz band (I only guessed the most important channels) and, if none is found, search for upconversion between the 0.1-0.7 Hz band and, say, the 1.2-1.8 Hz band.

It may be possible to reduce the ALS RMS by replacing the periscopes with periscopes that have higher resonant frequencies. We can probably get from 70 Hz to about 250 Hz by using the cylindrical periscopes from iLIGO. Stefan also suggested that we use a single periscope for both the red and green beams, reducing differential motion. I placed an accelerometer on the double periscope, also on ISCT1, and found the lowest resonance to be about 60 Hz. It is not clear to me whether putting both beams on a 60 Hz periscope or keeping them separate on 250 Hz periscopes, would result in the better RMS.

We may get a free factor of about 2 reduction in RMS contribution from the periscope motion after installation activities cease, because Figure 3 shows that ground motion in this band was about a factor of 2 lower during S6. After installation we would expect the ground motion to drop back down to the S6 level, reducing the need to change periscopes.

Figure 4 is a photo of the cylindrical periscopes from iLIGO that we gathered together near the squeezer bay with Corey’s help. None of them are complete, some parts would probably have to be remade.

Robert Schofield, Stefan Ballmer, Emily Maaske, Terra Hardwick, Vincent Roma, Brian Dawes, Tristan Shoemaker

Images attached to this report
Non-image files attached to this report
Comments related to this report
michael.coughlin@LIGO.ORG - 08:43, Tuesday 23 July 2013 (7175)
I have computed the coherence between H1_ASC-Y_TR_A_NSUM_OUT_DQ and many seismic and suspension channels in the 0.1-2 Hz band. As Robert noted, there is significant coherence between many of the seismic channels and the output channel. There are also a few suspension channels that also indicate high coherence in the 0.6-0.8 Hz band. I can also broaden my scope if there is interest. This is a slightly random channel list, and if there are channels that people would think could be interesting, I am happy to include them.
Images attached to this comment