TITLE: 07/11 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 3mph Gusts, 2mph 5min avg
Primary useism: 0.01 μm/s
Secondary useism: 0.06 μm/s
QUICK SUMMARY: Locked for 9 hours. Planned calibration and commissioning today from 830-1200PT (1530-1930 UTC).
We're running a patched version of simuLines during the next calibration measurement run. The patch (attached) was provided by Erik to try and get around what we think are awg issues introduce (or exacerbated) by the recent awg server updates (mentioned in LHO:78757). Operators: there's is nothing special to do. just follow the normal routine as I applied the patch changes in place. Depending on the results of this test, I will either roll them back or work with Vlad to make them permanent (at least for LHO).
Simulines was run right after getting back to NOIMINAL_LOW_NOISE. Script ran all the way until after Commencing data processing
, where it then gave:
Traceback (most recent call last):
File "/ligo/groups/cal/src/simulines/simulines/simuLines.py", line 712, in
run(args.inputFile, args.outPath, args.record)
File "/ligo/groups/cal/src/simulines/simulines/simuLines.py", line 205, in run
digestedObj[scan] = digestData(results[scan], data)
File "/ligo/groups/cal/src/simulines/simulines/simuLines.py", line 621, in digestData
coh = np.float64( cohArray[index] )
File "/var/opt/conda/base/envs/cds/lib/python3.10/site-packages/gwpy/types/series.py", line 609, in __getitem__
new = super().__getitem__(item)
File "/var/opt/conda/base/envs/cds/lib/python3.10/site-packages/gwpy/types/array.py", line 199, in __getitem__
new = super().__getitem__(item)
File "/var/opt/conda/base/envs/cds/lib/python3.10/site-packages/astropy/units/quantity.py", line 1302, in __getitem__
out = super().__getitem__(key)
IndexError: index 3074 is out of bounds for axis 0 with size 0
All five excitations looked good on ndscope during the run.
Also applied the following patch to simuLines.py before the run. The purpose being to extend the sine definition so that discontinuities don't happen if a stop command is executed late. If stop commands are all executed on time (the expected behavior), then this change will have no effect.
diff --git a/simuLines.py b/simuLines.py
index 6925cb5..cd2ccc3 100755
--- a/simuLines.py
+++ b/simuLines.py
@@ -468,7 +468,7 @@ def SignalInjection(resultobj, freqAmp):
#TODO: does this command take time to send, that is needed to add to timeWindowStart and fullDuration?
#Testing: Yes. Some fraction of a second. adding 0.1 seconds to assure smooth rampDown
- drive = awg.Sine(chan = exc_channel, freq = frequency, ampl = amp, duration = fullDuration + rampUp + rampDown + settleTime + 1)
+ drive = awg.Sine(chan = exc_channel, freq = frequency, ampl = amp, duration = fullDuration + rampUp + rampDown + settleTime + 10)
def signal_handler(signal, frame):
'''
Here's what I did:
cp /ligo/groups/cal/src/simulines/simulines/newDARM_20231221/settings_h1_newDARM_scaled_by_drivealign_20231221_factor_p1.ini /ligo/home/vladimir.bossilkov/gitProjects/simulines/simulines/settings_h1.ini
]./simuLines.py -i /opt/rtcds/userapps/release/cal/common/scripts/simuLines/logs/H1/20240711T234232Z.log
]No special environment was used. Output:
2024-07-12 14:28:43,692 | WARNING | It is assumed you are parising a log file. Reconstruction of hdf5 files will use current INI file.
2024-07-12 14:28:43,692 | WARNING | If you used a different INI file for the injection you are reconstructing, you need to replace the default INI file.
2024-07-12 14:28:43,692 | WARNING | Fetching data more than a couple of months old might try to fetch from tape. Please use the NDS2_CLIENT_ALLOW_DATA_ON_TAPE=1 environment variable.
2024-07-12 14:28:43,692 | INFO | If you alter the scan parameters (ramp times, cycles run, min seconds per scan, averages), rerun the INI settings generator. DO NOT hand modify the ini file.
2024-07-12 14:28:43,693 | INFO | Parsing Log file for injection start and end timestamps
2024-07-12 14:28:43,701 | INFO | Commencing data processing.
2024-07-12 14:28:55,745 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20240711T234232Z.hdf5
2024-07-12 14:29:11,685 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20240711T234232Z.hdf5
2024-07-12 14:29:20,343 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20240711T234232Z.hdf5
2024-07-12 14:29:29,541 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20240711T234232Z.hdf5
2024-07-12 14:29:38,634 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20240711T234232Z.hdf5
Seems good to me. Were you guys accidentally using some conda environment when running simulines yesterday? When running this I was in " cds-testing
" (which is the default?!). I have had this error in the past due to borked environments [in particular scipy which is the underlying responsible code for coherence], which is why I implemented the log parsing function.
The fact that the crash was on coherence and not the preceding transfer function calculation rings the alarm bell that scipy is the issue. We experienced this once in LLO with a single bad conda environment that was corrected, though I stubbornly religiously ran with a very old environment for a long time to make sure that error doesn't come up,
I ran this remotely so can't look at PDF if i run 'pydarm report'.
I'll be in touch over teamspeak to get that resolved.
Attaching the calibration report
There's a number of WAY out there data points in this report.
Did you guys also forget to turn off the calibration lines when you ran it?
Not marking this report as valid.
right, there was no expectation of this dataset being valid. the IFO was not thermalized and the cal lines remained on. The goal of this exercise was to demonstrate that the patched simulines version at LHO can successfully drive calibration measurements. And to that end the exercise was successful. LHO has recovered simulines functionality and we can lay to rest the scary notion of regressing back to our 3hr-long measurement scheme for now.
The run was probably in done in the 'cds' environment. At LHO, 'cds' and 'cds-testing' are currently identical. I don't know the situation at LLO, but LLO typically runs with an older environment than LHO.
Since it's hard to stay with fixed versions on conda-forge, it's likely several packages are newer at LHO vs. LLO cds environments.
TITLE: 07/11 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Observing at 154Mpc
INCOMING OPERATOR: Tony
SHIFT SUMMARY: Observing at 154Mpc and have been Locked for 2.5 hours. The wind looks to be dying down, but I did get a weather warning that the wind is supposed to pick up, so hopefully it's not too bad.
One lockloss during my shift (79012). When I first started relocking, ALSX was having issues giving high enough flashes, and I was seeing the fuzzy noise in the channel that indicates an issue with the crystal. While this was happening, ALS_XARM wasn't going into the FAULT or CHECK_CRYSTAL_FREQ states, so I just started adjusting ETMX and TMSX and as the flashes got higher, the fuzzy noise and crystal issues stopped.
Relocking took forever because of the high wind and earthquake, but once we finally got past FIND_IR, we were able to go the rest of the way up without issue. There had been a user message on the SQZ PMC guardian at 07/11 01:13 UTC (25 mins after LL) that said, 'PMC_REFL_RF35 demod error', and then kept trying and failing to lock the PMC, resulting in another message: 'Cannot lock PMC. Check SQZ laser power'. I contacted Daniel about this error once we were on our way up to NOMINAL_LOW_NOISE, but all he had to do was re-request the PMC to LOCKED and it unstalled and locked without issue.
LOG:
23:00 Observing and locked for 14.5 hours
00:50 Lockloss
- CPSFF is oscillating and big but peakmon is only at 70 so I'll start an initial alignment
- Some small issues locking ALSX
- The flashes were ~0.5 and the fuzzy noise that indicates something wrong with the crystal was happening every few seconds (attachment)
- ALS_XARM wasn't going to the CHECK_CRYSTAL_FREQ or FAULT states
- I just aligned ALSX by hand and as flashes got better, it stopped having the bad fuzzy noise
01:26 IA done, relocking
- Lockloss from FIND_IR x 3
02:20 Took us to down to run a manual initial alignment for INPUT_ALIGN X and Y arms
02:27 Back to DOWN and waiting out earthquake
03:53 Initial alignment
04:29 Started relocking
05:18 NOMINAL_LOW_NOISE
05:21 Observing
Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
---|---|---|---|---|---|---|
00:18 | PCAL | Rick, Francisco | PCAL Lab | y(local) | PCALin | 00:57 |
Just started an initial alignment.
After the lockloss (79012), wind was above 30mph and stayed that high for the next hour, and I believe that might be the reason why while trying to relock in FIND_IR, we would get XARM up but then lose lock before being able to try getting YARM up. In the past we have been able to relock with the winds this high, but I guess not today. While trying to troubleshoot this, we had a large earthquake hit us from the Phillipines (at 02:26 UTC), and just a few minutes ago the ground calmed enough for me to start another initial alignment.
Something strange that may or may not be related to the issues getting through FIND_IR is that after the lockloss and initial alignment, the DCPDs started growing (attachment). This growth in noise seems to turn 'on' and 'off' as the detector was trying to get past FIND_IR.
It's seemed to start increasing again while locking green arms in my current initial alignment.
Lockloss @ 07/11 00:50 UTC from sudden ground motion and also probably the sudden spike in wind.
05:21 UTC Observing
New OMC filter module configuration (new filter turned on) accepted in sdf
Ibrahim, Erik, Jeff
The third installation in our new rebuilt BBSS TF saga. See alog 79005 for context.
Now, since our model and BBSS are both reliably working, Oli and I will take TFs and post them in the next/a new alog.
TITLE: 07/10 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 65Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY: Locked for almost 15 hours. Rahul found some good damping settings for ITMY Mode 5 violin and it is damping very nicely. There are a few pending changes that should be loaded on a lock loss or out of observing time.
Pending changes:
H1LSC model has an unloaded filter which is to due Camilla PRCL FF that she will test tomorrow in the morning.
lscparams.py has the ITMY mode 5 violin mode updated but needs to be loaded into the guardian
IMC_LOCK needs a reload to take in notification changes
OMC DCPD Test bank needs the new anti whitening filters engaged for A1,B1,A2,B2
LOG:
Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
---|---|---|---|---|---|---|
16:25 | PCAL/FAC | Tony, Karen | PCAL lab | - | Tech clean and PCAL lab work | 16:58 |
17:54 | PCAL | Rick, Francisco, 2 visitors | PCAL lab | local | Lab tour | 20:19 |
18:29 | FAC | Chris | EY | n | Pickup equipment in fan room | 18:30 |
Following TFs on alog 79004, we have been diagnosing the noisy TFs and have come to the simple realization that the DAC is not working and that we were simply not actuating due to a broken IOP Model DAC. All the noise was simply the natural dynamic modes as they were hanging in the clean room. We're getting in contact with the CDS team to fix the issue. Stay tuned.
Oli's Quick partial investigation: Oli plotted multiple channels that the excitation goes through to see if we could narrow down causes (L, T, V, and R). Here are the results with ss of the ndscopes to help compare.
Viewing the January vs July attachments requires a caltech login, so here are the attachments for those without a caltech login:
L
T
V
R
Following up from alog78667 where Sheila compared AS_{A,B,C} powers and some of their ratios during our bad alignments and our good ones, I've done the same thing but at the ISC_LOCK state of Prep_DC_Readout_Transition (500). Just like before, the difference between the lowest good AS_C/AS_A ratio and the highest bad ratio is still pretty low. About the same actually.
AS_C NSUM (W in HAM6) | AS_A NSUM | AS_ B NSUM | AS_C/ AS_A | AS_C/ AS_B | |
6/6 20:53 UTC (bad) | 0.0724 | 6156 | 6670 | 1.176e-5 | 1.086e-5 |
6/7 2:42 UTC (bad) | 0.0759 | 6544 | 7063 | 1.160e-5 | 1.075e-5 |
6/7 3:29 UTC (bad) | 0.0763 | 6566 | 7082 | 1.162e-5 | 1.077e-5 |
6/6 12:19 (good) | 0.0862 | 7109 | 7335 | 1.213e-5 | 1.175e-5 |
6/6 7:20 UTC (good) | 0.0793 | 6540 | 6792 | 1.213e-5 | 1.168e-5 |
6/6 01:11 UTC (good) | 0.0797 | 6569 | 6781 | 1.213e-5 | 1.175e-5 |
6/5 10:59 UTC (good) | 0.0765 | 6292 | 6547 | 1.216e-5 | 1.169e-5 |
7/10 08:15 UTC (good) | 0.0790 | 6392 | 6771 | 1.236e-5 | 1.167e-5 |
7/9 20:51 UTC (good but with lower range) | 0.0789 | 6383 | 6754 | 1.236e-5 | 1.168e-5 |
TITLE: 07/10 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 18mph Gusts, 12mph 5min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.05 μm/s
QUICK SUMMARY:
Observing at 150Mpc and have been Locked for 14.5 hours. Winds going up a bit but not too bad.
There is another suspected failure of the power supply at the Staging building fire panel. This is supervisory alarm that will also trigger a local alarm at the OSB FACP. Johnson Controls has been made aware of the issue as has our monitoring provider. Given the nature of the alarm, there should be no triggering of any bells/horns/strobes etc., nor interruption to HVAC. Should the panel across the hall from the CR signal an alarm, please simply acknowledge (ACK) to silence. T. Guidry
Ibrahim, Oli, Betsy
Context:
The first article BBSS was built late 2023 and TFs taken for the first time 01/05/2024. These can be found in alog 75787 among other places in the X1 logbook. Transfer functions largely agreed with the dynamical model with a few changes outlined in alog 76381.
Last few months:
Following RAL's most recent trip, we have rebuilt the BBSS with the following major changes:
The Present:
As of 07/03, M1 OSEMs have been reconnected, centered and the second round of TFs taken on 07/03 (attachment 1). In comparison with 01/05 results (attachment 2), they seem extremeley noisy. Diagnostics in the following alog.
The following settings seems to be working for now and I will commit it in the lscparams after a couple of IFO lock stretches.
New settings (ITMY05/06):- FM5 FM6 FM7 FM10 Gain +0.01 (new phase -90 degree), might increase the gain later on depending upon how slow the damping is.
Nominal settings (ITMY05/06): FM6 FM8 FM10 Gain +0.02 (phase -30deg)
Given below are settings I tried this morning and it did not work,
1. no phase, 0.01 gain - increase
2. -30 phase, -0.01 gain - increase
3. +30 phase, 0.01 gain - increase
4. -30 phase, 0.01 gain - IY05 decreasing (both filters) IY06 increasing (both filters)
5. -60 phase, 0.01 gain - IY05 decreasing (both filters) IY06 increasing (only in narrow filter)
---
After talking to TJ, I have set the gain to zero on lscparams and saved it but not loaded it since we are OBSERVING. Will load it once there is a target or opportunity.
DARM spectra attached below shows that both the modes are slowly decreasing, next I will try and bump up the gain to 0.02.
ITMY 05/06 - FM5 FM6 FM7 FM10 Gain +0.02 has been saved in lscparams and violin mode Guardian has been loaded for the next lock.
We made a PRCL excitation we should later be able to use to create a PRCL FF, saved in lsc/h1/scripts/feedforward/PRCL_excitation.xml and exported .txt files.
I didn't taken PRCLFF injections, but the same high pass is used in MICH as PRCL, both fed to ETMY, so I used the last MICHFF injections for this.
Used NotItter_PRCL_FF_PrepareData.ipynb and InteractiveFitting to make a first go at a PRCLFF fit. See attached. This is ready for h1lsc load coefficients and then will be in FM1 as 7-10-24.
Daniel, Nutsinee
I was intrigued by the Twin Sisters Rock feature in the brand new spare SHG Terry and Karmeng put together so I did a little bit of digging. A quick summary is that we believe the Twin Sisters Rock feature were caused by the phase mismatch between the red and the green inside of the SHG cavity. We believe the dichroic coating of the SHG back mirror might be a suspect since the coating specifications can not be found. However, the phase mismatch doesn't neccessary explain the Mount Saint Helens in the 6 year-old SHG we are currently using.
The equation used to fit the data came from Gonzalez, Nieh, and Steier 1973 equation1. The equation looks similar to the usual sinc^2 function we know and love except that it's taken the phase mismatch between 532 and 1064 and the air dispersion into account in the cos^2 term. This paper also shows that the experimental data doesn't necessary match the model (Fig.3). The problem is we have to related deltaK*l term to temperature. This was done using Kato and Takaoka 2002. This left us with K_0. The only unknown-ish term here is the nonlinear coefficient d_eff inside of K_0. We used d_eff = 10pm/V as suggested by Leonardi et al 2018. After I wasn't able to get a sensible result Daniel pointed out that unit in K_0 doesn't add up. We replaced K0 with equation1 from Arie et al 1997.
The function is also very sensitive to polling length of the crystal. Since we don't have the exact number of the polling length, we picked a polling length such that deltaK is 0 at 34.6 C (optimal phase match condition). The polling length we got was 8.99608um. I believe the crystal polling length according to Raicol is 9um.
The function in the end looks like this. I was able to fit Karmeng's Twin Sisters Rock using sensible parameters (d_eff = 10pm/V, circulated 1064 power of 2W, Boyed-Kleinman focusing parameter = 0.9, and a phase shift of Pi/2). Other variations of the spare SHG plots can be explained by shifting this phi variable.
We suspect the coating of the SHG back mirror might be to blame. None of the SHG plots found in SURF reports (Nathan Zhao, Andre Medina) look symmetric like they should.
The zip file of the python code is also attached.
If the coating is not to blame, I wonder if it's time we think about redesigning a SHG that is more tolerant to the assembly line errors.
For people who are too lazy to read the paper: The dispersion that matters is between the first path and the second path in the crystal. In a simple dual path system, green light will be generated in phase with the red light in the first path, then the two frequencies propagate in air towards the rear mirror, where they are reflected with potentially different phases, and then propagate back to the crystal. According to Gonzalez et al. the dispersion in air for 1064/532 is 27.4°/cm (double passed). Our SHG length is about 5 cm long with a 1 cm crystal. So, the in-air path is of order 4 cm. You need a 90° phase shift to explain the double peak. However, the phase difference of our mirror reflectivity is unknown.
Daniel Nutsinee
We futher fit a single pass measurements with following parameters:
d_eff = 9pm/V
input power = 60mW
Boyd-Klienman factor = 0.35 (corresponds to w0 = 70um according to Karmeng this is what he sent into the cavity)
The measured power was so low a dark noise is required to offset the model to fit the data correctly. This value is 0.8 uW.
A factor of 1/2 has been added inside of sinc and cos term to convert from double pass to single pass. This agrees with Sheila's equation 3.14.
We also added a factor of 4 to the original function used to fit the double peak measurement to take into account the double pass (4 times the single pass power). A newly acquired Boyd-Klienman factor is 0.56 (corresponds to w0 = 55um, a beam waist dictates by the known cavity parameters). I recalculated circulated power taken into account loss measurement from the escape efficiency. The model suggests 1.7W. I managed to fit using 1.5W. We don't know the modulation depth used to generate the locking signal so this number can be wiggled around a bit. The facator of 4 can also be wiggled around a bit as we don't really know the green loss as it emerges from the cavity.
According to Karmeng the data was taken through a green Bandpass filter with 9% green loss. The data has been multipled by a factor of 1.09 to compensate for this loss.
In summary, our model fits both the Twin Sisters and the single pass measurements.
The first attachment shows spectra (GDS CALIB STRAIN clean, so with calibration corrections and jitter cleaning updated and SRCL FF retuned) with OM2 hot vs cold this week, without squeezing injected. The shot noise is slightly worse with OM2 hot, while the noise from 20-50Hz does seem slightly better with OM2 hot. This is not as large of a low frequency improvement as was seen in December. The next attachment shows the same no squeezing times, but with coherences between PRCL and SRCL and CAL DELTAL. MICH is not plotted since it's coherence was low in both cases. This suggests that some of the low frequency noise with OM2 cold could be due to PRCL coherence.
The optical gain is 0.3% worse with OM2 hot than it was cold (3rd attachment), before the OMC swap we saw a 2% decrease in optical gain when heating OM2 in Decmeber 74916 and last July 71087. This seems to suggest that there has been a change in the OMC mode matching situation since last time we did this test.
The last attachment shows our sensitivity (GDS CALIB STRAIN CLEAN) with squeezing injected. The worse range with OM2 hot can largely be attributed to worse squeezing, the time shown here was right after the PSAMs change this morning 78636 which seems to have improved the range to roughly 155Mpc with cleaning; it's possible that more psams tuning would improve the squeezing further.
Times used for these comparisons (from Camilla):
Side point about some confusion caused by a glitch:
The first attachment shows something that caused me some confusion, I'm sharing what the confusion was in case this comes up again. It is a spectrum of the hot no sqz time listed above, comparing the spectrum produced by dtt with 50 averages, 50% overlap, and BW 0.1 Hz (which requires 4 minutes at 15 seconds of data), compared to a spectrum produced by the noise budget code at the same time. The noise budget uses a default resolution of 0.1Hz and 50% overlap, and the number of averages is set by the duration of data we give it which is most often 10 minutes. The second screenshot shows that there was a glitch 4 minutes and 40 seconds into this data stretch, so that the spectrum produced by the noise budget shows elevated noise compared to the one produced by dtt. The third attachment shows the same spectra comparison, where the noise budget span is set to 280 seconds so the glitch is not included and the two spectra agree.
Comparison of sensitivity with OM2 hot and cold wihtout squeezing:
The next two attachments show spectra comparisons for no sqz times with OM2 hot and cold, (same times as above), the first shows a comparison of the DARM spectrum, and the second shows the range accumating as a function of frequency. In both plots, the bottom panel shows the difference in accumulated range, so this curve has a positive slope where the sensitivity of OM2 hot is better than OM2 cold, and a negative slope where OM2 hot is worse. The small improvement in sensitivity between 20-35 Hz improves the range by almost 5Mpc, then there is a new broad peak at 33Hz with OM2 hot which comes and goes, and again a benefit of about 4Mpc due to the small improvement in sensitivity from 40-50 Hz.
From 90-200 Hz the sensitivity is slightly worse with OM2 hot. The coupled cavity pole dropped from 440Hz to 424Hz while OM2 warmed up, we can try tuning the offsets in AS72 to improve this as Jennie and Keita did a few weeks ago: 78415
Comparison of with squeezing:
Our range has been mostly lower than 160 Mpc with OM2 hot, which was also true in the few days before we heated it up. I've picked a time when the range just hit 160Mpc after thermalization, 27/6/2024 13:44 UTC to make the comparison of our best sensititivites with OM2 hot vs cold. This is a time without the 33Hz peak, we gain roughly 7 Mpc from 30-55 Hz, (spectra and accumulated range comparisons) and loose nearly all of that benefit from 55-200 Hz. We hope that we may be able to gain back some mid frequency sensitivty by optimizing the PSAMs for OM2 hot, and by adjusting SRM alignment. This is why we are staying with this configuration for now, hoping to have some more time to evaluate if we can improve the squeezing enough here.
There is a BRUCO running for the 160Mpc time with OM2 hot, started with the command:
python -m bruco --ifo=H1 --channel=GDS-CALIB_STRAIN_CLEAN --gpsb=1403531058 --length=400 --outfs=4096 --fres=0.1 --dir=/home/sheila.dwyer/public_html/brucos/GDS_CLEAN_1403531058 --top=100 --webtop=20 --plot=html --nproc=20 --xlim=7:2000 --excluded=/home/elenna.capote/bruco-excluded/lho_excluded_O3_and_oaf.txt
It should appear here when finished: https://ldas-jobs.ligo.caltech.edu/~sheila.dwyer/brucos/GDS_CLEAN_1403531058/
(Jenne, Jordan, Gerardo)
On Monday June 24, I noticed an increase on pressure at HAM6 pressure gauge only. Jordan and I tried to correlate the rise on pressure to other events but we found nothing, we looked at RGA data, but nothing was found, then Jenne pointed us to the OM2 thermistor.
I looked at the event on question, and one other event related to changing the temperature of OM2, and the last time the temperature was modified was back on October 10, 2022.
Two events attached.
Some more analysis on pressure vs OM2 temperature in alog 78886: this recent pressure rise was smaller than the first time we heated OM2 after the start of O4 pumpdown.