Displaying reports 79661-79680 of 86376.Go to page Start 3980 3981 3982 3983 3984 3985 3986 3987 3988 End
Reports until 21:49, Friday 28 June 2013
LHO General
patrick.thomas@LIGO.ORG - posted 21:49, Friday 28 June 2013 (6927)
plots of dust counts
Attached are plots of dust counts requested from 5 PM June 27 to 5 PM June 28.
Non-image files attached to this report
H1 ISC
stefan.ballmer@LIGO.ORG - posted 21:47, Friday 28 June 2013 - last comment - 17:09, Sunday 30 June 2013(6928)
HIFOY Noise
(Kiwamu, Chris, Sheila, Daniel, Stefan)

We tweaked both acoustic noise sources and feed-back scheme today.
Result: 8Hz RMS down to 0.1Hz, 9Hz RMS down to 0.01Hz.

Details:
- turned off purge air escape noise and clean room HEPA fans (improved spectrum above 3Hz up to 6kHz.
- lowered the CARM feed-back gain by 42dB (new UGF is probably around 150Hz)
- added insane boosts at low frequency to squash arm motion
- there was also a loose connection at the PFD input, which was the reason for a low beat node strengh
- realigned the beat node beam splitter, we got 200mVpkk beat note

Still to do:
- there is some clipping on the doubler path and y-arm path - so we'll have to do a realignment.
- we need to attenuated the signal power at the new IR trans LSC PD
- need to do a noise characterization of the end station electronics, in particular we want the PFD noise and the PDH dark noise
- finish setting up the IR REFL demod signal.


In other news, we worked on the IR REFL path: installed a trigger PD and power source.
Non-image files attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 22:09, Friday 28 June 2013 (6929)
For the fun of it, we also measured the free spectral range by moving from one fringe to the next:

FSR:   37455.5Hz +-15Hz (VCO uncertainty)
Lengh: 4001.98m +-1.6m

And BTW: we are now locked for 70minutes and countig
stefan.ballmer@LIGO.ORG - 23:53, Friday 28 June 2013 (6930)
I forgot to mention that the above plots include Sheila's updated calibration for the detuned cavity pole. De factor this pushed all traced (including yesterday's) up at hight frequencies, but attenuated them somewhat around 100Hz.
kiwamu.izumi@LIGO.ORG - 15:57, Saturday 29 June 2013 (6931)

This is a video showing how the infrared transmitted light looks like when we were stabilising and bringing the PSL frequency to a resonance of the Y arm cavity.

It is clear that ALS provides us with a smooth control of the PSL frequency !

kiwamu.izumi@LIGO.ORG - 16:29, Saturday 29 June 2013 (6932)

We left the CARM at the half fringe of the arm. This stayed for approximately 5 hours from roughtly 4:00 to 9:00 in UTC. I am not sure why it lost the lock.

Images attached to this comment
stefan.ballmer@LIGO.ORG - 17:09, Sunday 30 June 2013 (6934)

Josh Smith and other folks from DetChar are pointing out that the 65-73 Hz signal that limits the RMS above 2Hz is coherent with HAM3 GS13s:

https://wiki.ligo.org/DetChar/HIFOYDetcharChallenge

 

Attached is also a DTT plot of the 60Hz-80Hz reagion including the GS13s on HAM3. Interestingly the full coherent region corresponds to a dip in the GS13 power spectrum.

Non-image files attached to this comment
H1 SUS
mark.barton@LIGO.ORG - posted 18:14, Friday 28 June 2013 - last comment - 11:48, Monday 01 July 2013(6926)
More SUS screen cleanup

I did a lot of refining of the SUS-AUX screens I created the other day in alog 6893, as well as the SITEMAP and related SUS screens:

* I created argument macro files for the new screens and adjusted the SITEMAP to use them: susauxham2_overview_macro.txt, susauxham34_overview_macro.txt, susauxham56_overview_macro.txt, susauxex_overview_macro.txt and susauxey_overview_macro.txt.

* While I was at it, I created macro files for BSTST and the IM overview: susbstst_overview_macro.txt and susimall_overview_macro.txt. (The text for BSTST that I transferred from SITEMAP lacked assignments for UTF1 etc, leading to whiteness on the screens, so I copied the ones for BS. This may well be wrong and the BSTST and QUADTST files need to be checked against the H2 circuit diagram.)

* I edited the SITEMAP, the screens created the other day, and linked screens several deep, to call linked screens via macro files: SUS_AUX_HAM2_OVERVIEW.adl, SUS_AUX_HAM34_OVERVIEW.adl, SUS_AUX_HAM56_OVERVIEW.adl, SUS_AUX_EX_OVERVIEW.adl and SUS_AUX_EY_OVERVIEW.adl, quad/SUS_AUX_QUAD_OVERVIEW.adl, bsfm/SUS_CUST_BSFM_MONITOR_OVERVIEW.adl, hxts/SUS_CUST_HXTS_MONITOR_OVERVIEW.adl, omcs/SUS_CUST_OMCS_MONITOR_OVERVIEW.adl and tmts/SUS_AUX_TMTS_OVERVIEW.adl.

Every call from the SITEMAP should now look like (viewing the .adl file in a text editor)

        name="$(USERAPPS)/sus/common/medm/SUS_AUX_EY_OVERVIEW.adl"

        args="%(read $(USERAPPS)/sus/common/medm/susauxey_overview_macro.txt),USERAPPS=$(USERAPPS),SITE=LHO,site=lho,IFO=H1,ifo=h1"

and every call from another screen should look like

        name="$(USERAPPS)/sus/common/medm/hxts/SUS_CUST_HXTS_MONITOR_OVERVIEW.adl"
        args="%(read $(USERAPPS)/sus/common/medm/susmc1_overview_macro.txt),USERAPPS=$(USERAPPS),SITE=$(SITE),site=$(site),IFO=$(IFO),ifo=$(ifo)"

* I cleaned LLO-specific and apparently unused cruft out of the individual IM macro files: susim1_overview_macro.txt, susim2_overview_macro.txt, susim3_overview_macro.txt and susim4_overview_macro.txt.

* I made generic an LLO-specific call to SUS_CUST_QUAD_OVERVIEW in SUS_AUX_QUAD_OVERVIEW.

* I added a button from bsfm/SUS_CUST_BSFM_MONITOR_OVERVIEW.adl to SUS_CUST_BSFM_OVERVIEW.adl, as for QUAD, TMTS and OMCS. I looked at doing the same for hxts/SUS_CUST_HXTS_MONITOR_OVERVIEW.adl but came up against the problem that it would have to point to different screens depending on the suspension type (HSTS/HLTS).

All the above changes were committed to the SVN. I was careful to make all new stuff generic, so if LLO svn up's the lot it _shouldn't_ break anything. However there were a few isolated LLO-specific references that I weeded out, so care will be required. Odds will be better if the LLO SITEMAP uses the idiom illustrated above.

Comments related to this report
mark.barton@LIGO.ORG - 11:48, Monday 01 July 2013 (6937)

I proofed susbstst_overview_macro.txt and susquadtst_overview_macro.txt.

The quadtst one was mostly right but had one typo (one case of RRT should have been URRT), leading to two white fields on the R0 subscreen.

The U* arguments that I added to the bstst file on Friday were all wrong, but I the equivalent ones without U (for the IOP rather than user model) were correct, so I was easily able to adapt them.

I committed the corrected files.

H1 CDS
cyrus.reed@LIGO.ORG - posted 16:59, Friday 28 June 2013 (6925)
Multicast routing enabled in core network
I have enabled multicast routing in the core switch to allow multicast streams to be routed to the ops network from the auxilliary network (between VLAN 20 and 106) - this is to support the upcoming digital video system.  The Loopback0 interface has been created in the switch to act as the PIM RP[1] for the CDS network, with address 172.17.2.1/32.  Interfaces Vlan20 and Vlan106 are configured to use 'ip pim sparse-dense-mode'.  No other VLANS are currently configured to route multicast traffic.

[1] Protocol Independent Multicast Rendezvous Point
H1 SEI
vincent.lhuillier@LIGO.ORG - posted 16:48, Friday 28 June 2013 (6924)
State of the ISI to set the feedforward filters

The feedforward control is used as a complement of the feedback control mainly to reduce the motion around 10Hz (created by the HEPI piers). The L4Cs installed in the HEPI boots are used to feed the stage 1 actuators.

In https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=6768, the feedforward filters were set-up using transfer functions measured while the ISI was damped.  I evaluated how the ideal feedforward filters would change if the ISI was “feedback controlled”. I compared the ideal feedforward filters obtained in the two configurations: Damped vs feedback controlled (attachment shows the feedforward filter for the X direction).
Above 1Hz (super sensor dominated by the inertial sensor), the two filters are almost identical. The ground path and the force path are modified in the same manner by the feedback control.
Regarding these results, it doesn’t seem essential to measure transfer functions with the ISI “feedback controlled” to set the feedforward controllers.

Images attached to this report
LHO General
jeffrey.bartlett@LIGO.ORG - posted 15:48, Friday 28 June 2013 (6923)
Ops Summary
Apollo removing door bolts on HAM5/6
Greg and Apollo craning optics tables into East Bay enclosure
Michael & Pablo in H2-PSL enclosure
Kyle replacing annulus ion pump on GV1
Betsy working around ITM-X Test Stand

LHO VE
kyle.ryan@LIGO.ORG - posted 15:33, Friday 28 June 2013 (6922)
Helium removal -> Valved-out MTP turbo @ 1500 -> 2.8 x 10-7 torr*L/sec indicated


			
			
LHO General
john.worden@LIGO.ORG - posted 14:31, Friday 28 June 2013 (6921)
Clean rooms over HAM1,2 3

Two large clean rooms were turned off at the request of the HIFO crew.

HAM1,2 cleanroom and HAM3 cleanroom.

Time of occurrence ~ 14:06 local time.

The two small clean rooms in the same area are on temporary power and may be turned off for short periods ~1 or 2 hours. They are currently ON.

 

 

 

LHO VE
kyle.ryan@LIGO.ORG - posted 03:55, Friday 28 June 2013 (6918)
CP6 PID slow to respond to delivery Thursday -> will make adjustments as necessary


			
			
H1 ISC
kiwamu.izumi@LIGO.ORG - posted 00:37, Friday 28 June 2013 - last comment - 12:02, Friday 28 June 2013(6915)
HIFO: veterx noise hunting, SHG inspection and REFL alignment work

[Stefan, Chris, Kiwamu]

We spent some time today at ISCT1 to locate the forest-type noise at around 1 kHz which we saw in the ALS CARM signal (see alog 6900) and also did some hardware works.

We did find a couple of suspicious optics on the table although we are still studying how they pollute the ALS CARM signal. We have stick foam in the mount of every reflective optic on the table to help their mechanical damping ability. The work continues.

 

Noise hunting at ISCT1

To do noise hunting on ISCT1 we did a speaker technique --- we hooked up a small speaker at the output of the common mode servo while keeping the green beatnote within the PLL's readout range by ezcaservo acting on the ALS_COMM VCO. The ALS CARM noise sounded mostly high frequency-ish although we didn't confirm how exactly high the frequency was. Then we bought the speaker close to every optic to see if they resonate due to the acoustic (positive) feedback at exactly the same frequency as that of the ALS CARM noise. We found a couple of optics which do resonate with the CARM sound. They are :

We are suspicious about these optics. They may be the ones introducing the forest noise at around 1 kHz. We have stick foam in the mount of every reflective optic to damp unwanted mechanical vibration. We will take another noise spectrum tomorrow to see how this improves it.

 

SHG mystery

There has been a mystery that somehow the SHG efficiency dropped by  a factor of 4 or so at some point (approximately from 0.5 mW to 0.1 mW level) and it didn't come back to the high value. As a part of the ISCT1 works we inspected the doubling oven to see if there is an obvious clipping or something stupid. However we didn't find a thing. We did the following things:

After all these works we measured the SHG power again and it was measured to be 0.140 uW which is still low compared with the past. It is still unclear what happened and we are not quite sure how this can be related to the ALS CARM noise.

 

REFL alignment

To evaluate the residual noise in the PSL frequency we needed a length sensor of the Y arm, namely the interferometer reflection (REFL) RFPD. We started rearranging the optics to guide the REFL beam to the RFPD. The work is ongoing. Currently the REFL beam is dumped. To prevent a damage on the RFPD due to an accidental power increment we need the trigger function of the mechanical shutter working.

Comments related to this report
kiwamu.izumi@LIGO.ORG - 00:49, Friday 28 June 2013 (6916)

As for the SHG power measurement,the SHG power is consistent with the monitor PD signal. I think the low power at 0.1 mW level is real. On the other hand I was unable to measure the incident 1064 nm power on the doubling crystal --- the Ophir power meter didn't give us a reasonable number when the filter was put on the head. I tried to measure the power without the filer but this simply saturates the signal, indicating the power is more than 100 mW. I will try measuring this power with another power meter.

christopher.wipf@LIGO.ORG - 12:02, Friday 28 June 2013 (6917)
A video to show how we did the ISCT1 noise hunting:

H1 SUS
mark.barton@LIGO.ORG - posted 20:59, Thursday 27 June 2013 - last comment - 13:13, Friday 28 June 2013(6914)
HTTS (Tip-Tilt) Models added

 

I created a case of the Mathematica model TwoWireSimpleBlades to represent the HTTP (Tip-Tilt) in the SVN at
 
^/trunk/Common/MathematicaModels/TwoWireSimpleBlades/20130627TipTilt
 
and a matching Matlab parameter set at
 
^/trunk/Common/MatlabTools/SingleModelProduction/httsopt_test.m
 
in the SVN. There's also a wiki page with parameters, a mode frequency table and mode shape plots: 
 
https://awiki.ligo-wa.caltech.edu/aLIGO/Suspensions/OpsManual/HTTS/Models/20130627TipTilt
 
I used parameters from P1100090-v5 = Rev. Sci. Instrum. 82, 125108 so it should be close to reality, although there are a few minor issues of interpretation that will hopefully be cleared up in the next few days.
 
I also renamed the Matlab HAUX parameter set in the same directory from hauxtest.m to hauxopt_test.m to parallel other such files, and edited generate_Single_Model_Production.m to define short names hauxtest and httptest.
Comments related to this report
mark.barton@LIGO.ORG - 13:13, Friday 28 June 2013 (6919)

Bram clarified that 'pendulum length' in P1100090 was exclusive of dpitch, whereas yesterday's version assumed it was equivalent to tl0 which includes dpitch.

Preferred version is now Mathematica 20130628TipTilt or Matlab httpopt_test.m r5013 of 6/28/13. Wiki page is

https://awiki.ligo-wa.caltech.edu/aLIGO/Suspensions/OpsManual/HTTS/Models/20130628TipTilt

LHO General
patrick.thomas@LIGO.ORG - posted 19:51, Thursday 27 June 2013 (6913)
plots of dust counts
Attached are plots of dust counts requested from 5 PM June 26 to 5 PM June 27.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:46, Thursday 27 June 2013 (6912)
plots of dust counts
Attached are plots of dust counts requested from 5 PM June 25 to 5 PM June 26.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:42, Thursday 27 June 2013 (6911)
plots of dust counts
Attached are plots of dust counts requested from 5 PM June 24 to 5 PM June 25.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:38, Thursday 27 June 2013 (6910)
plots of dust counts
Attached are plots of dust counts requested from 5 PM June 23 to 5 PM June 24.
Non-image files attached to this report
H1 ISC
sheila.dwyer@LIGO.ORG - posted 19:00, Thursday 27 June 2013 (6909)
PD and temporary camera set up on ISCEY
There is a camera on the IR transmission on ISCETY, and the PD is aligned.  

I turned the periscope by 90 degrees, and removed two unlabeled TCS optics that were on the periscope.  (part of the Hartman reference path).  There are still the other optics from that path that need to be removed, and a better beam dump is needed.  

I took the power for the camera from the Green refl camera (the second connector on that cable is a different connector) Filiberto connected the signal to the blue cable on CB7-050-0005, which is now connected to channel B on the lower of the monitors in the front of the control room. It would be good to add a longer focal length lens and an ND filter.  

The reason for adding the camera was that this morning we were locking on a first order mode, but could not tell from the control room.  

Displaying reports 79661-79680 of 86376.Go to page Start 3980 3981 3982 3983 3984 3985 3986 3987 3988 End