Reports until 14:31, Friday 28 June 2013
LHO General
john.worden@LIGO.ORG - posted 14:31, Friday 28 June 2013 (6921)
Clean rooms over HAM1,2 3

Two large clean rooms were turned off at the request of the HIFO crew.

HAM1,2 cleanroom and HAM3 cleanroom.

Time of occurrence ~ 14:06 local time.

The two small clean rooms in the same area are on temporary power and may be turned off for short periods ~1 or 2 hours. They are currently ON.

 

 

 

LHO VE
kyle.ryan@LIGO.ORG - posted 03:55, Friday 28 June 2013 (6918)
CP6 PID slow to respond to delivery Thursday -> will make adjustments as necessary


			
			
H1 ISC
kiwamu.izumi@LIGO.ORG - posted 00:37, Friday 28 June 2013 - last comment - 12:02, Friday 28 June 2013(6915)
HIFO: veterx noise hunting, SHG inspection and REFL alignment work

[Stefan, Chris, Kiwamu]

We spent some time today at ISCT1 to locate the forest-type noise at around 1 kHz which we saw in the ALS CARM signal (see alog 6900) and also did some hardware works.

We did find a couple of suspicious optics on the table although we are still studying how they pollute the ALS CARM signal. We have stick foam in the mount of every reflective optic on the table to help their mechanical damping ability. The work continues.

 

Noise hunting at ISCT1

To do noise hunting on ISCT1 we did a speaker technique --- we hooked up a small speaker at the output of the common mode servo while keeping the green beatnote within the PLL's readout range by ezcaservo acting on the ALS_COMM VCO. The ALS CARM noise sounded mostly high frequency-ish although we didn't confirm how exactly high the frequency was. Then we bought the speaker close to every optic to see if they resonate due to the acoustic (positive) feedback at exactly the same frequency as that of the ALS CARM noise. We found a couple of optics which do resonate with the CARM sound. They are :

We are suspicious about these optics. They may be the ones introducing the forest noise at around 1 kHz. We have stick foam in the mount of every reflective optic to damp unwanted mechanical vibration. We will take another noise spectrum tomorrow to see how this improves it.

 

SHG mystery

There has been a mystery that somehow the SHG efficiency dropped by  a factor of 4 or so at some point (approximately from 0.5 mW to 0.1 mW level) and it didn't come back to the high value. As a part of the ISCT1 works we inspected the doubling oven to see if there is an obvious clipping or something stupid. However we didn't find a thing. We did the following things:

After all these works we measured the SHG power again and it was measured to be 0.140 uW which is still low compared with the past. It is still unclear what happened and we are not quite sure how this can be related to the ALS CARM noise.

 

REFL alignment

To evaluate the residual noise in the PSL frequency we needed a length sensor of the Y arm, namely the interferometer reflection (REFL) RFPD. We started rearranging the optics to guide the REFL beam to the RFPD. The work is ongoing. Currently the REFL beam is dumped. To prevent a damage on the RFPD due to an accidental power increment we need the trigger function of the mechanical shutter working.

Comments related to this report
kiwamu.izumi@LIGO.ORG - 00:49, Friday 28 June 2013 (6916)

As for the SHG power measurement,the SHG power is consistent with the monitor PD signal. I think the low power at 0.1 mW level is real. On the other hand I was unable to measure the incident 1064 nm power on the doubling crystal --- the Ophir power meter didn't give us a reasonable number when the filter was put on the head. I tried to measure the power without the filer but this simply saturates the signal, indicating the power is more than 100 mW. I will try measuring this power with another power meter.

christopher.wipf@LIGO.ORG - 12:02, Friday 28 June 2013 (6917)
A video to show how we did the ISCT1 noise hunting:

H1 SUS
mark.barton@LIGO.ORG - posted 20:59, Thursday 27 June 2013 - last comment - 13:13, Friday 28 June 2013(6914)
HTTS (Tip-Tilt) Models added

 

I created a case of the Mathematica model TwoWireSimpleBlades to represent the HTTP (Tip-Tilt) in the SVN at
 
^/trunk/Common/MathematicaModels/TwoWireSimpleBlades/20130627TipTilt
 
and a matching Matlab parameter set at
 
^/trunk/Common/MatlabTools/SingleModelProduction/httsopt_test.m
 
in the SVN. There's also a wiki page with parameters, a mode frequency table and mode shape plots: 
 
https://awiki.ligo-wa.caltech.edu/aLIGO/Suspensions/OpsManual/HTTS/Models/20130627TipTilt
 
I used parameters from P1100090-v5 = Rev. Sci. Instrum. 82, 125108 so it should be close to reality, although there are a few minor issues of interpretation that will hopefully be cleared up in the next few days.
 
I also renamed the Matlab HAUX parameter set in the same directory from hauxtest.m to hauxopt_test.m to parallel other such files, and edited generate_Single_Model_Production.m to define short names hauxtest and httptest.
Comments related to this report
mark.barton@LIGO.ORG - 13:13, Friday 28 June 2013 (6919)

Bram clarified that 'pendulum length' in P1100090 was exclusive of dpitch, whereas yesterday's version assumed it was equivalent to tl0 which includes dpitch.

Preferred version is now Mathematica 20130628TipTilt or Matlab httpopt_test.m r5013 of 6/28/13. Wiki page is

https://awiki.ligo-wa.caltech.edu/aLIGO/Suspensions/OpsManual/HTTS/Models/20130628TipTilt

LHO General
patrick.thomas@LIGO.ORG - posted 19:51, Thursday 27 June 2013 (6913)
plots of dust counts
Attached are plots of dust counts requested from 5 PM June 26 to 5 PM June 27.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:46, Thursday 27 June 2013 (6912)
plots of dust counts
Attached are plots of dust counts requested from 5 PM June 25 to 5 PM June 26.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:42, Thursday 27 June 2013 (6911)
plots of dust counts
Attached are plots of dust counts requested from 5 PM June 24 to 5 PM June 25.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:38, Thursday 27 June 2013 (6910)
plots of dust counts
Attached are plots of dust counts requested from 5 PM June 23 to 5 PM June 24.
Non-image files attached to this report
H1 ISC
sheila.dwyer@LIGO.ORG - posted 19:00, Thursday 27 June 2013 (6909)
PD and temporary camera set up on ISCEY
There is a camera on the IR transmission on ISCETY, and the PD is aligned.  

I turned the periscope by 90 degrees, and removed two unlabeled TCS optics that were on the periscope.  (part of the Hartman reference path).  There are still the other optics from that path that need to be removed, and a better beam dump is needed.  

I took the power for the camera from the Green refl camera (the second connector on that cable is a different connector) Filiberto connected the signal to the blue cable on CB7-050-0005, which is now connected to channel B on the lower of the monitors in the front of the control room. It would be good to add a longer focal length lens and an ND filter.  

The reason for adding the camera was that this morning we were locking on a first order mode, but could not tell from the control room.  

LHO General
patrick.thomas@LIGO.ORG - posted 17:14, Thursday 27 June 2013 - last comment - 09:04, Tuesday 09 July 2013(6907)
Ops Summary
8:50 Pablo and Colin to H2 PSL laser enclosure
Corey informed me that he, Virginio and Keita would be working on and off in the end X transmon lab
10:00 Michael R. to H2 PSL laser enclosure
10:54 electric man-lift pickup
well sampling
CP6 filled
Dave rebooted the DAQ for Vincent
1:29 Pablo, Colin, Michael R. and Rick going into H2 PSL laser enclosure
Cyrus took down a network switch, which took down the H1 PSL Beckhoff, H1 PSL video cameras and communication to the dust monitor in the diode room. Switch was rebooted and restored.
all left the H2 PSL laser enclosure
Comments related to this report
patrick.thomas@LIGO.ORG - 09:04, Tuesday 09 July 2013 (7020)
I believe there was also talk of tightening bolts on a spool piece and installing HEPI electronics at end X in the morning meeting.
H1 DAQ
james.batch@LIGO.ORG - posted 17:01, Thursday 27 June 2013 (6908)
Reconfigure h1fw0 raw minute data
Cyrus, Dave, Jim

Attached a new SSD RAID to h1fw0.  This RAID is to be used for storage of raw minute data that was formerly written to the SATAboy hard drive array in LDAS.  Reconfigured the h1fw0 daqd to write raw minute data to /trend/minute_raw instead of /frames/trend/minute_raw.  Reconfigured h1nds0 to read raw minute data from both /frames/trend/minute_raw and /trend/minute_raw.  The raw minute data in /frames/trend/minute_raw is now in two subdirectories of /frames/trend/minute_raw, and is considered archive data while still being available for viewing via h1nds0.

Note that frame files written to /frames/full, /frames/trend/minute, and /frames/trend/second are not affected by this change.

The benefit of this change is a remarkable decrease in the amount of time required to write raw minute data, allowing it to be written much more often.  Hopefully this will help make h1fw0 more stable, as the daqd process was having difficulty writing files in the time allocated for the task.  The downside is the raw minute data will have to be copied to the archive as the SSD RAID fills up, which is a maintenance task to be performed a few times per year.
LHO VE
kyle.ryan@LIGO.ORG - posted 16:16, Thursday 27 June 2013 (6905)
Helium removal
Valved-out YBM turbo @ 1600 hrs. -> 4.0 x 10-7 torr*l/sec indicated
H1 CDS
cyrus.reed@LIGO.ORG - posted 15:34, Thursday 27 June 2013 (6904)
Emergency switch reboot (sw-lvea-aux0)
I had to do an emergency reboot of sw-lvea-aux0 today at 14:51 local time, to correct some copy-paste induced errors in the config.  The reboot was (unfortunately) the quickest way to restore the working configuration.  It should be functioning normally now.
H1 COC
gerardo.moreno@LIGO.ORG - posted 17:46, Wednesday 26 June 2013 - last comment - 16:17, Thursday 27 June 2013(6895)
PUM-ETM04 Prism Update

(Betsy W, Gerardo M, Gerardo A. M)
Prism was removed today, finally. It took about 7 days of the common process of soaking the prism joint in acetone, then working on the joint by hand with a razor blade along with some acetone as a lubricant.
2 photos attached, one is where the prism used to be, second photo is the removed specimen.

Images attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 12:19, Thursday 27 June 2013 (6902)

The prism will be reglued (into a new position that corrects for the ear placement error) during the early part of the week of July 8th.  The PUM will then be packed up and sent to LLO for use in their ETMx monolithic suspension.

norna.robertson@LIGO.ORG - 16:17, Thursday 27 June 2013 (6906)
This timing for regluing depends on our having resolved the likely cause of the PUM crack and how to avoid it happening again during future welds.
H1 SUS
mark.barton@LIGO.ORG - posted 12:26, Wednesday 26 June 2013 - last comment - 10:34, Thursday 27 June 2013(6890)
TMTS channels added to DAQ

Per a request of Jeff K, I made an additional update to the TMTS_MASTER.mdl, to add DAQ requests for the 6 ...M1_DAMP_*_IN2 channels. I then rebuilt and restarted h1sustmsy.mdl.

In the process I noticed that there were error messages being generated from the following lines in the safe.snap (these may have been there yesterday, see alog 6883, but I don't recall), so I manually edited the file and removed the second half of each line.

H1:SUS-TMSY_M1_DAMP_P_STATE_GOOD 1 H1:SUS-TMSY_M1_DAMP_P_STATE_GOOD 0
H1:SUS-TMSY_M1_DAMP_R_STATE_GOOD 1 H1:SUS-TMSY_M1_DAMP_R_STATE_GOOD 0
H1:SUS-TMSY_M1_DAMP_T_STATE_GOOD 1 H1:SUS-TMSY_M1_DAMP_T_STATE_GOOD 0
H1:SUS-TMSY_M1_DAMP_V_STATE_GOOD 1 H1:SUS-TMSY_M1_DAMP_V_STATE_GOOD 0
H1:SUS-TMSY_M1_DAMP_Y_STATE_GOOD 1 H1:SUS-TMSY_M1_DAMP_Y_STATE_GOOD 0

Chris Wipf then reported that sometime in the last few days, the setting for the alignment offset gains in the safe.snap had been reset to 1 (whereas they are supposed to be magic numbers that convert mrad of desired offset to counts of actuation). So I transplanted the following lines from an hourly backup from 6/20/13:

H1:SUS-TMSY_M1_OPTICALIGN_P_OFFSET 1 -8.950000000000000e+01
H1:SUS-TMSY_M1_OPTICALIGN_P_GAIN 1 1.583586000000000e+02
H1:SUS-TMSY_M1_OPTICALIGN_Y_OFFSET 1 1.899000000000000e+02
H1:SUS-TMSY_M1_OPTICALIGN_Y_GAIN 1 5.171050000000000e+01

The updated master model and safe.snap have been committed.

Comments related to this report
arnaud.pele@LIGO.ORG - 10:34, Thursday 27 June 2013 (6901)

This first error probably happened after the snapshot update I made for the "STATE_GOOD" channels of every suspension with a generic script (cf aLog 6813) and the second  because I didn't update the safe snapshot after applying the changes to the TMTS alignment offset gains (cf aLog 6749)

H1 SUS
betsy.weaver@LIGO.ORG - posted 10:02, Sunday 23 June 2013 - last comment - 12:56, Thursday 27 June 2013(6858)
Violin mode measurements of ETMx monolithic silica fibers

Giles report from yesterday's work:

(Travis, Mark, Jason, Doug, Giles)

 

After leaving the PUM hanging overnight there was no further development of the crack. We then proceeded to re-lock the PUM and hang the ETM to perform modal measurements. Using the autocollimator we measured the longitudinal, pitch and yaw modes. We then setup and optical lever to measure the transverse, bounce and roll modes. Finally we measured the 4 fundamental violin modes. The modal data gathered was:         

 

Longitudinal    0.656 Hz

Pitch  1.09 Hz

Yaw  1.09 Hz

Transverse 0.656 Hz

Bounce 6.75 Hz (this will be sqrt(2) higher when the PUM is free)

Roll 9.6 Hz (this will be sqrt(2) higher when the PUM is free)

 

FR  505 Hz

FL  506.5 Hz

BR  506.5 Hz

BL  505 Hz

 

We finally installed the fibre guards and covered the entire lower stage.

Comments related to this report
betsy.weaver@LIGO.ORG - 10:25, Wednesday 26 June 2013 (6889)

Serial Numbers of fibers on the suspension now:

 

FL S1300183

FR S1300191

BL S1300190

BR S1300193

 

S1300186 was trashed during the welding as it was installed and then cut out as noted above.

travis.sadecki@LIGO.ORG - 12:56, Thursday 27 June 2013 (6903)

Correction: BR is actually S1300173.