Displaying reports 79841-79860 of 86335.Go to page Start 3989 3990 3991 3992 3993 3994 3995 3996 3997 End
Reports until 11:58, Tuesday 11 June 2013
H1 SEI
hugh.radkins@LIGO.ORG - posted 11:58, Tuesday 11 June 2013 (6702)
WBSC9 SEI ISI Unit#5 is on the Test Stand
No issues to report here.  The ISI is on the Test Stand shifted south one set of holes (7".)  Like EndY, this is to accommodate the TMS installation.  Let us know soon if this is not appropriate.
LHO VE
john.worden@LIGO.ORG - posted 10:30, Tuesday 11 June 2013 (6700)
Pumpdown of vertex volume

This is a log-log plot with a 1/t curve superimposed with exponent of 0.85. Also shown is a zoom in of the last 10 days.

It appears that we have cleared up some virtual leaks(annuli?) in our pumping exercises.

Images attached to this report
H1 AOS
stefan.ballmer@LIGO.ORG - posted 10:16, Tuesday 11 June 2013 (6699)
Optical lever motion with and without green arm lock
Attached are plots of oplev signals of ETMY and ITMY, as well as the arm cavity reflected power (ALS-Y_REFL_B_LF_OUT).
Plot 1 shows the signals in lock.
Plot 2 is a time series in lock.
Plot 3 shows the same signals as plot 1, but out of lock.
Note that neither channel is properly calibrated yet. (TBD)

Conclusion:
- The limiting peaks are ~0.44Hz and ~0.55Hz.
- Both ETMY and ITMY show the motion.
- Our slow feed-back of the length signal to ETMY M0 makes them worse for ETMY in-lock.
Images attached to this report
H1 SUS
arnaud.pele@LIGO.ORG - posted 19:30, Monday 10 June 2013 - last comment - 08:15, Tuesday 11 June 2013(6696)
MC2 M2 to M2 transfer functions

Started transfer functions measurements with DTT on MC2 for M2 and M3 masses. ISI is damped. Lock filters and alignment offsets have been turned off.

Comments related to this report
arnaud.pele@LIGO.ORG - 08:15, Tuesday 11 June 2013 (6697)

Measurements completed successfully

H1 ISC
stefan.ballmer@LIGO.ORG - posted 19:15, Monday 10 June 2013 (6695)
Beating the corner ALS
(Alexa, Kiwamu, Daniel, Stefan)

Since the HAM1 was leveled, we first fine-tweaked the PR3 alignment to maximize the ALS-C_TRY_A_DC signal.
New PR3 alignment: P:-150, Y:125 (i.e. we moved -5ct in pitch). We have not re-tweaked the IR beam.

Then we build the beat node path on ISCT1. Daniel fixed the SHG TEC (I have not idea how). So far we only used Kiwamu's pre-calculated mode-matching solution, without fine-tweaking it. We had to steel a power supply diode from a neighboring table to power the 18V needed for the broad-band PD. (Needs its own power cable.)

With all that we got a nice beat-node up to 100mVpkk (out of about 600mVpkk that we guess from a back-of-the-envelope estimate). Still room for improvement. Most importantly though, the beam was fluctuating a lot. We need to revisit the ETM and ITM suspensions/ISIs.

Also I did fine-tweak the transmission monitor table (TMTS) alignment slightly in pitch to reduce the arm intensity fluctuations: from -14400 to -13820 counts.
The arm is still moving too much tough.

To do next:
- Stabilize the ETM and ITM to reduce arm motion
- Measure beam profile out of the corner SHG
- Measure beam profile out of the arm
- Wire the beat node PD's power cable
- Configure the electronics for feeding back to the input mode cleaner CM board.


On that note: We should really change our nomenclature for the "Common Mode Board". The name is purely historical. We have so many of those now, and most of them have very little to do with a "common mode". My proposal: the "Sigg Servo Board"...



LHO General
michael.rodruck@LIGO.ORG - posted 16:40, Monday 10 June 2013 (6693)
Ops summary
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:13, Monday 10 June 2013 (6692)
LHO EndX SEI HEPI System Fluid Analysis Report
The fluid analysis for EndX after flushing for almost 5 weeks can be found at T1300527.  All the LHO HEPI Fluid Analyses can be found at T1300521.
H1 SEI
hugo.paris@LIGO.ORG - posted 14:56, Monday 10 June 2013 (6691)
HAM Status
Here is the current status of the aLIGO SEI work regarding the HAM chambers. Everything in bold is to be completed for HIFO-Y. Everything in red is a change from last week's status. Everything in green is available.

 

·         HAM 1

o    HEPI unlocked and running
      Ongoing commissioing

·         HAM2

o   ISI: previously commissioned with HEPI locked (recent performance spectra), currently unlocked, in vacuum

o   HEPI: to be commissioned, currently locked, models and electronics ready. Commissioning could starts once the IMC locks again.

·         HAM 3

o   ISI: previously commissioned with HEPI locked (recent performance spectra), currently unlocked, in vacuum

o   HEPI: To be commissioned, currently locked, model and electronics ready. Commissioning could start once the IMC locks again.

·         HAM 4 

o   ISI: In chamber, Previously tested during assembly validation, currently locked, no suspension installed, in-vac cables not connected, chamber temporarily closed.
     Electronics ready, in field cables ready, in-rack cables 90%

o   HEPI: Currently locked, to be commissioned
     Electronics ready, in field cables ready, in-rack cables 90%

·         HAM 5

o   ISI: In Chamber, Previously tested during assembly validation, currently locked, no suspension installed, in-vac cables not connected, chamber temporarily closed.         
    Electronics ready, in field cables ready, in-rack cables 90%

o   HEPI: Currently locked, to be commissioned     
     Electronics ready, in field cables ready, in-rack cables 90%

·         HAM 6

o   ISI: in a container. Need to be retrofitted with aLIGO censors (GS13, CPS) and to receive a new set of Actuator Cables. Cables and inertial sensors will be tested prior to installation. All this will happen chamber-side prior to installation in chamber. Commissioning will follow.
    Electronics and cables started, the rest is ordered

o   HEPI: Currently locked, to be commissioned

     Electronics ready, in-rack cables 90%Here is the current status of the aLIGO SEI work regarding the HAM chambers. Everything in bold is to be completed for HIFO-Y. Everything in red is a change from last week's status. Everything in green is available.

 

·         HAM 1

o    HEPI: To be commissioned, currently locked
       Electronics and cables ready

 

·         HAM2

o   ISI: previously commissioned with HEPI locked (recent performance spectra), currently unlocked, in vacuum

o   HEPI: to be commissioned, currently locked, models and electronics ready. Commissioning could starts once the IMC locks again.

·         HAM 3

o   ISI: previously commissioned with HEPI locked (recent performance spectra), currently unlocked, in vacuum

o   HEPI: To be commissioned, currently locked, model and electronics ready. Commissioning could start once the IMC locks again.

·         HAM 4 

o   ISI: In chamber, Previously tested during assembly validation, currently locked, no suspension installed, in-vac cables not connected, chamber temporarily closed.
     Electronics ready, in field cables ready, in-rack cables 90%

o   HEPI: Currently locked, to be commissioned
     Electronics ready, in field cables ready, in-rack cables 90%

·         HAM 5

o   ISI: In Chamber, Previously tested during assembly validation, currently locked, no suspension installed, in-vac cables not connected, chamber temporarily closed.         
    Electronics ready, in field cables ready, in-rack cables 90%

o   HEPI: Currently locked, to be commissioned     
     Electronics ready, in field cables ready, in-rack cables 90%

·         HAM 6

o   ISI: in a container. Need to be retrofitted with aLIGO censors (GS13, CPS) and to receive a new set of Actuator Cables. Cables and inertial sensors will be tested prior to installation. All this will happen chamber-side prior to installation in chamber. Commissioning will follow.
    Electronics and cables started, the rest is ordered

o   HEPI: Currently locked, to be commissioned
     Electronics ready, in-rack cables 90%

H1 SEI
greg.grabeel@LIGO.ORG - posted 14:52, Monday 10 June 2013 (6690)
HEPI status

HEPI Actuator status:

Bleed Mode Run Mode
HAM 2 HAM 1
HAM 3 BSC 1
HAM 4 BSC 2
HAM 5 BSC 6
HAM 6  
BSC 3  
BSC 9  


BSC 9 was put into bleed mode Friday afternoon (6/7). The float level had to be adjusted as the pressure went up. The end X pump station was set to run ~80psi.

H1 SEI
hugh.radkins@LIGO.ORG - posted 14:27, Monday 10 June 2013 (6689)
WHAM1 Support Tble/Optical Leveling--Done
See my notes attached if you wish.

The Support Table was level to within 0.3mm.  I am using a different reference although they are tied together but the elevation it self is ~1mm higher than the elevation from 1 October.  Still, I think most will say this can be ignored.  So, we did not do any Support Table leveling with HEPI.

Moved up to look at the Optical Table, out of level about the same as yesterday, reasonable.  Removed 5kg of 'extra mass', that is, part of the mass I added to account for the to-be-installed components back in October.  There still remains some 14 kg of extra mass, to-be-removed later when more components are installed onto the Optical Table.  We shifted this mass around to level the table and got the level to +-0.1mm at -185.7mm local or -199.8 global, about ~0.5mm higher than in October and within 0.2mm of spec -200mm per D0901821.

The Extra Mass is not bolted down.  It consists of one 10kg D0901075 with 2 stacks adjacent each consisting of one D080001 & four D080002 masses.  The Extra Mass is located close to the East side of the Optical Table just South of mid-way.
Non-image files attached to this report
H1 SEI
hugo.paris@LIGO.ORG - posted 11:12, Monday 10 June 2013 (6688)
HAM1-HEPI

Bias switched were turned ON on HAM1-HEPI to allow adjusting alignment, if needed, with offsets applied by the actuators.

LHO VE
john.worden@LIGO.ORG - posted 10:09, Monday 10 June 2013 (6687)
LVEA Pumpdown - 40 days

After many changes to the pumping configuration we appear to be on a downward curve again. During the last 20 days of this pumpdown we have valved in main ion pumps, pumped and leak tested numerous annuli, valved in and out the main turbo and leak tester, changed out a few annulus ion pumps, and cycled the beam tube valves.

So far Kyle has not seen a significant response to helium testing. It is possible that we are now seeing the outgassing of all the assemblies in the vertex volume - 1xBSC, 1xITM, 3xHAM

 

Images attached to this report
H1 SUS
mark.barton@LIGO.ORG - posted 13:10, Sunday 09 June 2013 - last comment - 19:12, Monday 10 June 2013(6685)
Resuming MC1/MC2/MC3 TFs

Arnaud started MC1/MC2/MC3 M2/M3 TFs on Friday, but they were interrupted by Saturday commissioning activity. It appears they were in the middle of MC1 M3 when they were stopped, so I'm restarting them there shortly. Commissioning has priority so text/email me if you need them shut down.

Comments related to this report
mark.barton@LIGO.ORG - 07:35, Monday 10 June 2013 (6686)

Progress checked at 7:30 am - had finished at 4:37 am. MC1, 2, 3 are available for commissioning work.

arnaud.pele@LIGO.ORG - 19:12, Monday 10 June 2013 (6694)

Transfer functions went through, but are showing a lack of coherence. As it is the first time M2 to M2 and M3 to M3 transfer functions are running for the mode cleaner suspensions with a matlab script, input parameters as the drive amplitude need to be twicked to get better results. For now, I will simply use the dtt templates from LLO (see aLog 7247 ) to run them.

H1 ISC
stefan.ballmer@LIGO.ORG - posted 21:07, Saturday 08 June 2013 - last comment - 22:31, Saturday 08 June 2013(6683)
HAM1 work
(Daniel, Kiwamu, Chris, Stefan)

- Using PR3 we pointed the green beam to the center of the septum view port. some pointing references for PR3:
   PIT: -145, Yaw: 125  Center of septum view port, we left it there
   PIT clips at -85 and -206
   Yaw clips at +75 and +198

- Kiwamu moved the top periscope mirror in HAM1 up until the green beam was centered on it. The periscope yaw position agreed well with the center of view port. He then guided both the green ALS beam and the POB beam (actually IR, but we used green as alignment proxy) to ISCT1. Note that the POB beam does not yet have all its hardware, but we suspect it might be useful later. We dumped all stray beams on ISCT1, and put the green beam on H1:ALS-C_TRY_A_DC to have a reference.

- For the red beam - unlike yesterday -we were not able to get IM4 TRANS pitch to zero (using a MC move), possibly due to falling off the WFS sensors. For now we ignored this. 

- We then realigned the red beam following the same procedure as yesterday. (PR3/PR2 walk keeping fringes, putting PR3 to its desired spot. PR2/IM4 walk to optimize transmitted fringes). This actually gave us a signal in the POB quads (H1:ASC-POP_A_SUM_OUT and H1:ASC-POP_B_SUM_OUT)

- Finally we also hunted and found the PRM alignment. Power recycling fringes with a power gain of about 3 are visible on both POB quadrant diodes and as stray light on the ITM cage.

- The attached alignment snapshot reflects the fully aligned power recycling cavity (incl PRM).




Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 22:31, Saturday 08 June 2013 (6684)
The power of the green beam on ISCT1 was measured to be 2.8 mW.
H1 IOO
stefan.ballmer@LIGO.ORG - posted 12:46, Saturday 08 June 2013 - last comment - 15:04, Saturday 08 June 2013(6680)
Who is measuring stuff on the MC SUS?
I found the MC alignment offsets off and a measurement in progress when I got in, but I have no idea who is measuring, as I am the only one one site. Please call the control room.

Stefan
Comments related to this report
arnaud.pele@LIGO.ORG - 14:52, Saturday 08 June 2013 (6681)

I was measuring consecutively MC1/MC2/MC3 M2 to M2 and M3 to M3 transfer functions over the week end. The script can be killed by closing matlab windows on workstation 2, and overwriting the current excitation with awggui.

I will make sure to post an aLog next time.

christopher.wipf@LIGO.ORG - 15:04, Saturday 08 June 2013 (6682)
Sorry, Stefan.  Arnaud told me in advance that he wanted to do this and I forgot to pass the word along.
Displaying reports 79841-79860 of 86335.Go to page Start 3989 3990 3991 3992 3993 3994 3995 3996 3997 End