sheila.dwyer@LIGO.ORG - posted 16:50, Tuesday 30 April 2013 (6229)
Fiber transmission
I measured the transmission of the fiber at end Y:
coming out of fiber 35 uW
1.5uW towards trans PD
19uW in the wrong polarization
8 uW towards beamsplitter

It looks like we need to use the polarization adjuster box to fix this.  I will put a calibrtion of the PDs into the PLC.  

 
LHO General
cheryl.vorvick@LIGO.ORG - posted 16:03, Tuesday 30 April 2013 (6228)
Ops
- praxair
- bottled water
- sprague

- reboots to dust monitors - some red alarms - all cleared
- work in EX and EY caused some dust
- EY IOP State Word went red a few times
- PSL env. monitoring went white a few times
- no reboots that were run by me - except a reboot of the DAQ around 4PM by VIncent
- I discovered that HAM2 and HAM3 had offsets for ISI change yesterday - not me, not Vincent
- I put HAM2 and HAM3 optics at their correct slider values and have them damped for alignment check - I have no tests running
- lots of work at EY and EX
H1 IOO
cheryl.vorvick@LIGO.ORG - posted 13:59, Tuesday 30 April 2013 (6227)
Alignment in-air of IO to PRC:
Alignment in-air of IO up to PRC:

- MC1	
P	335um	 628 counts
Y	-795um	-2131 counts

- MC2	
P	505um	 946 counts
Y	250um	 670 counts

- MC3	
P	177um	 331 counts
Y	-894um	-2396 counts

- IM1	
P		 2330 counts
Y		-170 counts

- IM2	
P		-1880 counts
Y		-300 counts

- IM3	
P		 2850 counts
Y		 300 counts

- IM4	
P		-2100 counts
Y		-950 counts

- PRM - aligned	
P	-830um	-1556 counts
Y	-50um	-134 counts

- PRM - parked	
P	-330um	-618 counts
Y	-6100um	-16351 counts

- PR2 - best guess	
P	1400um	2625 counts
Y	900um	2412 counts
LHO General
patrick.thomas@LIGO.ORG - posted 20:34, Monday 29 April 2013 (6225)
plots of dust counts
Attached are plots of dust counts requested from 5 PM April 28 to 5 PM April 29.

The dust monitor at location 4 in the LVEA keeps stopping due to an unknown loss of power.
Non-image files attached to this report
H1 SUS
arnaud.pele@LIGO.ORG - posted 17:59, Monday 29 April 2013 (6223)
SUS medm screens USER model and IOP model DAC outputs finally populated!

[Dave Arnaud]
Following Stuart's update of medm screens at LLO, the previous aLogs, and the recent update of medm macro character limit (from 256 to 2048), Dave and I edited the changes on the SITEMAP for all suspensions* at LHO.

*except for ITMX/ETMX/TMSX/BSTST and HAUX

H1 IOO
cheryl.vorvick@LIGO.ORG - posted 16:27, Monday 29 April 2013 (6222)
IOT2L REFL path rework
I started the rework of the IOT2L layout today.  Changes were made after LLO had some experience with their table.  With the new layout, I found that our REFL PD and the new position for the WFS1 pico motor were incompatible, so I move the WFS1 pico motor toward it's pick-off be 3", and moved WFS1 by 3" to achieve the same path length as on the new layout of 290mm.  Pictures of REFL PD, WFS1 and WFS2 attached.  Also attached is a list of components and their status for the REFL path - i.e. which components are currently not on the table.
Images attached to this report
Non-image files attached to this report
LHO General
corey.gray@LIGO.ORG - posted 16:20, Monday 29 April 2013 (6221)
Ops DAY Summary
H1 SEI
hugo.paris@LIGO.ORG - posted 10:48, Monday 29 April 2013 (6218)
HAM2 HAM3 - ISIs Damped

The damping loops for HAM2 and HAM3 ISIs were turned ON, uppon SUS's request.

LHO VE
kyle.ryan@LIGO.ORG - posted 17:21, Sunday 28 April 2013 (6217)
1725 hrs. -> Leaving site now


			
			
LHO VE
kyle.ryan@LIGO.ORG - posted 16:48, Sunday 28 April 2013 (6216)
Pumping Vertex for an hour or two while I work on misc.


			
			
H1 CDS
daniel.sigg@LIGO.ORG - posted 11:04, Sunday 28 April 2013 (6215)
TwinCAT systems

Both the corner and EY Beckhoff systems were updated to the most recent versions. Apart from some cleanup a number of channel names changed to bring the slow controls system in line with the real-time system:

This will require some changes with medm screens. This version now has a complete set of hardware links with the excpetion of the rotation stages.

The EPICS gateways for the corner PLC1 channels are currently not running due to the lareg numbers of channels.

LHO VE
kyle.ryan@LIGO.ORG - posted 23:54, Friday 26 April 2013 (6214)
16 hrs day today -> I'm going home now -> will resume pumping YBM+BSC1-3+HAM2-3 on Monday


			
			
H1 IOO
kiwamu.izumi@LIGO.ORG - posted 18:17, Friday 26 April 2013 (6213)
IOT2L in place again

[Patrick, Keita, Sheila, Kiwamu]

 The IOT2L enclosure was rolled close to HAM2. So now IOT2L is at the official permanent place again.

The two light pipes between HAM2 and IOT2L are back on.

Currently the west area of HAM1 and 2,  where IOT2L and ISCT1 reside, are isolated by the black curtain-ish laser barriers.

H1 CDS
kiwamu.izumi@LIGO.ORG - posted 17:47, Friday 26 April 2013 (6212)
sitemap changed

The LSC, ASC and ALS pull down tabs were moved from the right side to the left as they don't necessarily belong to a particular location (i.e. LVEA and EY). The attached is the curent view of SITEMAP.adl.

Images attached to this report
LHO General
gerardo.moreno@LIGO.ORG - posted 16:23, Friday 26 April 2013 (6211)
Ops Shift Summary

- Apollo "crew" torqued some doors and viewports, and cleared/checked other items, see entry by Jodi.
- Betsy did a walk around input chambers/LVEA area this morning, final check before pump down.
- Michael and Joe, Viewport final check, LVEA, before pump down.
- Travis to work around HAM2 and HAM3, camera work.
- Kyle started pump down of YBM+BSC01+BSC02+BSC03+Inputtube-HAM01, see his entry.
- Keita, et.al., moved/set IOT2L in place.
- Cheryl to LVEA to work in IOT2L.
- King soft water to visit LSB RO system, charcoal work.

LHO VE
kyle.ryan@LIGO.ORG - posted 12:56, Friday 26 April 2013 (6210)
~1145 Began pump down process of YBM, BSC1-3 and HAM2-3 combined volumes
Dew point of "blow down air" < -25C
H1 INS
jodi.fauver@LIGO.ORG - posted 12:48, Friday 26 April 2013 (6209)
HIFO Close-out-LVEA Update
There were a couple of items from the list to clear up this morning: torquing of bolts at HAM3 and check to see that all ports have some pump-down worthy covering. In addition, Kyle had a couple of items for the Apollo crew to attend to. I added those items to the bottom of the list. 

1.	Done-Remove Walking Plates from BSC 2 (Place in E-Mod Staging Cleanroom)
2.	Done-Replace dome on BSC2 (Check with SEI first: unlock ISI check cables)
3.	Done-Place hard cover on BSC2/HAM3 spool openings
4.	Done-Install curtains on HAM3 cleanroom
5.	Done-Move BSC cleanroom to beamtube by East Bay pipe bridge
6.	Done-Dis-assemble Work Platform (Place on floor by ?????)
7.	Done-Move HAM3 cleanroom north as far as possible
8.	Done-Close gaps in cleanroom to contain BSC2 spool area
9.	Done-Move SEI related electronics over center of spool area
10.	Done-Insert small spool piece
11.	Done-Insert large spool piece
12.	Done-Install HAM3 east door
13.	Done-Move cleanroom from pipe bridge area to HAM4-plug in-turn on
14.	Done-Call for HAM4 cleaning
15.	Done-Install HAM2/1 east doors
16.	Done-Install HAM 2/3 west doors
17.	Done-Install BSC1 viewports
18.	Done-Remove HAM4 north door
19.	Done-Install blank on septum plate between BSC2 and HAM4
20.	Done-Install HAM4 north door
21.	Done-Torque all bolts (except HAM1 and HAM4-4 bolts only)
22.	Done-Check for holes
23.     Done-Remove the "hinged" HAM4 bellows retraction tie-rods per Kyle
24.     Done-Remove, inspect and re-flange (using LIGO hardware) the 10" CFF blank that is in the 2 o-clock position on the MC tube-HAM3 adapter and which is labeled as "not leak tested" per Kyle
25.     Done-Return HAM4 bellows tie-rods per John     ;-)

As far as I know, all Apollo tasks are complete in preparation for HIFO pump-down.
H1 CDS
james.batch@LIGO.ORG - posted 12:41, Friday 26 April 2013 (6208)
Configure network settings of HPI pump controller at EY
Configured HPI pump controller at EY for eventual connection to network.  It now appears as "h1hpipumpctrley" instead of "localhost", and it's IP address is set up for connection to the 10.105 VLAN.  The EPICS channel names still need to be changed in a similar fashion to the corner station controller.  This does allow a slightly modified laptop to be connected to it to view the MEDM screen at the controller, so the resource-hungry desktop manager doesn't have to be run on the controller.

Vincent and I left the controller running, with the system pressurized.
H1 General
keita.kawabe@LIGO.ORG - posted 17:32, Thursday 25 April 2013 - last comment - 15:15, Monday 29 April 2013(6207)
Viewports are good (Thomas, Sheila, Keita)

BSC2, IY adapter, HAM1, HAM2 and HAM3 have all viewports necessary for the full IFO.

BSC1 is good for HIFO but one viewport for CO2 laser should be installed in the future.


For video and illuminator viewports, no inspection was made except to confirm that something was installed.

For viewports that receive 1064nm and/or 532nm beam, we made a visual inspection to see the color of the surface, and all seemed to have some AR. No attempt was made to tell 1064/532 combo AR from so-called "high quality" optic (iLIGO 1064nm viewports?).

Thomas looked at oplev viewports and confirmed that they are the correct ones.


Following is a list of what is installed and what is not. Viewport numbers are based on https://dcc.ligo.org/T1000746.

BSC1 (IY): Illumination (G3), IY alternative video (G2), IY CP video (G11).

CO2 laser viewport (C0G5) is going to have to be installed in the future, but not this time.

BSC2 (BS): Oplev IN/OUT (G2), Video BS (G8), Illuminator (G9)

IY adapter A-1: Oplev IY OUT (VP1), IY Video (VP2), Oplev IY IN (VP4).

FTIMY-related viewports (VP3, 5B, 6) are not installed as we don't have H2.

HAM1: Video (A2F1) and Illuminator (A2F4) on the east door. IR PSL (A1F5), ALS green (A1F4) and POP/REFL (A1F3) on the west door.

HAM2: Faraday input video (A2F1), General video(A2F2), "IO trans mon & PRC MM mon beam" (A2F3), "IO trans mon & PRC MM mon beam" (A2F4), PRM video (A2F5) on the east door.

General video (A1F2), Illuminator (A1F1), MC1 Video (A1F3), MC REFL (A1F4), SM1 TRANS (A1F5) on the west door.

MC3 video (D7), Faraday output, SM1 and SM2 video (C1) and REFL parking (D8) on top.

It doesn't make sense that both A2F4 (left on the east door) and A2F3 (middle) are specified to use 1064/532nm combo viewport for the same purpose. There are two beams coming through SM2 (IM4) but both of them come out of A2F3.

A2F4 is valuable as a video viewport, so we can proceed with this configuration, but somebody needs to confirm my suspicion that VP800 is good enough for A2F3,  and then T1000746 should be updated.

HAM3: PR2 video (A2F3) on the east door. Illuminator (A1F3), MC2 Trans (A1F4) and MC2 Video (A1F5) on the west door.

WAMCA1 attachment by HAM2: PR2 Video (VP3), Oplev HAM3 in/out (VP7, not VP5 as specified by T1000746), Video MC2 (VP9).

WAMCB1 attachment by HAM3: MC3 video (VP3), Oplev HAM2 IN/OUT (VP5), Oplev PR3 IN (VP7), PRM Video (VP9), MC1 Video (VP10), Oplev PR3 out (VP11), PR3 Video (VP12).

Comments related to this report
keita.kawabe@LIGO.ORG - 15:15, Monday 29 April 2013 (6220)

Correction:

"It doesn't make sense that both A2F4 (left on the east door) and A2F3 (middle) are specified to use 1064/532nm combo viewport for the same purpose. There are two beams coming through SM2 (IM4) but both of them come out of A2F3.

A2F4 is valuable as a video viewport, so we can proceed with this configuration, but somebody needs to confirm my suspicion that VP800 is good enough for A2F3, and then T1000746 should be updated."

The above should read:

"It doesn't make sense that both A2F4 (middle on the east door) and A2F3 (left) are specified to use 1064/532nm combo viewport for the same purpose. There are two beams coming through SM2 (IM4) but both of them come out of A2F3."

A2F4 is valuable as a video viewport, so we can proceed with this configuration, but somebody needs to confirm my suspicion that VP800 is good enough for A2F4, and then T1000746 should be updated."

H1 SUS
arnaud.pele@LIGO.ORG - posted 09:45, Monday 15 April 2013 - last comment - 12:42, Monday 29 April 2013(6081)
BeamSplitter phase 3a (pre)testing

Beamsplitter transfer functions have been running over the weekend in order to fix any issues during the day if needed.

The attached pdfs show :

  1. Comparison between last TF damping on and model
  2. Comparison between last TF damping off and model
  3. Comparison between LHO damping on/off and LLO phase 3a (feb 2013) TFs
  4. Zoomed version of 3.

Vertical degree of freedom is noisier than expected between 1.5 and 3Hz (3rd page of each pdf).

Non-image files attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 15:10, Monday 15 April 2013 (6087)

Gerardo went into the chamber, checked the EQ stops, and nothing is apparently touching. When the chamber will be free tomorrow during the day, I will run quick DTT measurements for the vertical degree of freedom, between 1 and 3Hz and see if it's still noisy. There were no need of taking the night for full measurements since the other DOFs are fine. I let the night to Vincent for ISI tfs if needed.

arnaud.pele@LIGO.ORG - 13:44, Monday 22 April 2013 (6158)

I ran a DTT transfer function on the vertical degree of freedom of the beamsplitter this morning

New TF looks nicer than the old one from April 12th, meaning the beamsplitter is healthy and passed Phase 3a testing

Will run a full set of TF tonight, for our record.

Data of the DTT measurement has been saved in a matlab structure named :M1VtoM1V_20130422.mat under SusSVN/sus/trunk/BSFM/H1/BS/SAGM1/Data and has been commited to the svn

Non-image files attached to this comment
arnaud.pele@LIGO.ORG - 12:42, Monday 29 April 2013 (6219)

Last measurement on the beamsplitter has been taken monday night April 22nd with damping on and off, before pumping down BSC2 chamber.

One thing to notice :

Vertical degree of freedom remains noisy around 2Hz, as on April 12th, even though dtt transfer function from aLOG 6158 doesn't show any issues. It could be that when taking TF with matlab, the drive for that frequency band is not high enough. I will try with higher gains in the MATLAB_TFs.m script and see if it changes anything. 