Displaying reports 80201-80220 of 86139.Go to page Start 4007 4008 4009 4010 4011 4012 4013 4014 4015 End
Reports until 20:48, Wednesday 17 April 2013
LHO General
patrick.thomas@LIGO.ORG - posted 20:48, Wednesday 17 April 2013 (6119)
plots of dust counts
Attached are plots of dust counts requested from 5 PM April 15 to 5 PM April 16.

I have not included plots of the counts in the optics labs, because of the 'nan' in the data when I rebooted the IOC to test a new version of the code. I did this starting at 3:06 PM April 16. The modified code should fix this bug and is scheduled to be installed next Tuesday.
Non-image files attached to this report
H1 IOO
cheryl.vorvick@LIGO.ORG - posted 19:46, Wednesday 17 April 2013 (6118)
IMC not flashing, but it's due to the covers on the HAM2 doors pushing the ISI
Door covers are so tight the touch the ISI on both sides of HAM2.

IO closeout still to do::
- check beam on psl wall 
- flash IMC
- align REFL to HAM1 - needs coordination with ISC crew
- align HAM2 QPD
- check all baffles
- check POP/ALS path in HAM3
- align West side of HAM2 beams with viewport simulator.

Viewport simulater was crammed in the HAM2 clean room across the steps, so had to be moved, and will need to be wiped again before hanging on an open HAM2 door.

H1 TCS
greg.grabeel@LIGO.ORG - posted 18:38, Wednesday 17 April 2013 - last comment - 14:37, Friday 19 April 2013(6117)
BSC2 Steering Mirror Assemblies
The two steering mirror assemblies, D1101851, are installed in BSC2. They went in fairly smoothly. One hitch is where the support bracket attaches to the chamber's lower bracket; the weld from the lower bracket to the chamber wall kept the two surfaces from mounting flush.

The two mirrors are NOT installed yet. They oxidized during their bake and I am still working on figuring out if anything should be done about that. The mirrors shed a little, but it seems as though they are not shedding anywhere near the level that the chamber itself is.
Images attached to this report
Comments related to this report
greg.grabeel@LIGO.ORG - 14:37, Friday 19 April 2013 (6143)
Went in today to get better pictures. Specifically you can see where the mating to the chamber is somewhat inhibited by the weld.
Images attached to this comment
H1 AOS
hugo.paris@LIGO.ORG - posted 16:07, Wednesday 17 April 2013 - last comment - 15:11, Friday 19 April 2013(6116)
HAM3-IS - Viton Pads Test

We set up Viton Pads under HAM3-ISI balancing masses. The size of those pads is the same as the size of LLO's. However we set those pads under 1/2 the mass LLO uses, in order to rise the corner frequency of the mass+Viton stack.

Comparison before/after is attached.

The Viton Pads improve the 310Hz peak in V efficiently, by a factor > 5 without any drawback to it. Results are satisfying enough for now. We may try other configurations next time the chamber is open.

Non-image files attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 15:11, Friday 19 April 2013 (6142)

This Viton Pads Efficiency Test was plotted in the cartesian basis. Results are attached.

Best improvements can be seen along RX and RY, in the 310Hz region. Suspension modes can be seen there and they are known to be coupling with the ISI. 

Plots show that the Viton Pads we used helped limiting the impact of SUS/SEI couplings, on the ISI's Transfer Functions.

Having those viton pads should also facilitate the design of control loops, and eventually allow pushing the performance a bit further, as more gain margin will be available.

Non-image files attached to this comment
H1 General
andres.ramirez@LIGO.ORG - posted 16:02, Wednesday 17 April 2013 (6115)
Day Shift Events
08:00 Reset all the alarm handlers 
09:30 Start measurements (Transfer Functions) on HAM 3 ISI – Hugo P
10:45 Start/Continue assembly work on H2 LAE PCAL – Pablo
12:10 Work (Inspection)on LVEA main crane – John Worden
13:45 Cable work by HAM 4 on the LVEA – Filiberto C.
14:49 LVEA Transitioned to Laser Hazard - Cheryl
15:00 IO Alignment on HAM2/HAM/3 in the LVEA – Cheryl
H1 DAQ
david.barker@LIGO.ORG - posted 15:23, Wednesday 17 April 2013 - last comment - 15:32, Wednesday 17 April 2013(6113)
DAQ restart, add h1seib3 models and Beckhoff ecat msr channels

Restarted the DAQ at 15:14 and 15:17. Added all h1seib3 systems (IOP, ISIITMX and HPIITMX). Also added back the ECATC1.ini EDCU file to support slow controls commissioning.

Needed two starts, three of the Beckhoff channels do not seem to exist and were commented out.

Comments related to this report
david.barker@LIGO.ORG - 15:32, Wednesday 17 April 2013 (6114)

the DAQ restart glitched data from the following front ends: h1susb6, h1susauxb6, h1sush56, h1susauxh34.

MX streamers were restarted on all, DAQ status became GOOD on all.

H1 SEI
hugo.paris@LIGO.ORG - posted 12:34, Wednesday 17 April 2013 (6112)
HAM3-ISI - Measurements Done

Measurements are complete on HAM3-ISI. The Apollo crew can proceeed there.

H1 INS
jodi.fauver@LIGO.ORG - posted 08:07, Wednesday 17 April 2013 (6110)
Apollo work for 16 April 2013
Crane work continued:bearings for main crane arrived, one installed and packed; still working on X End crane.
HIFO-related viewport checklist being worked.
Test Stand cleanroom transported from Y End to X End. Frame re-assembled.
H1 AOS
douglas.cook@LIGO.ORG - posted 07:53, Wednesday 17 April 2013 - last comment - 10:31, Thursday 18 April 2013(6109)
BSC2 Status
Gerardo finished up the optical lever periscope for the BS.
The  Y-arm baffle is aligned. 
The  Y-arm baffle needs to have the brackets removed to fully suspend it...do not forget this
The  X-arm is not aligned due to the mounting bolt pattern issue he encountered
The platform remains inside under the X baffle
IAS needs to finish breaking down our equipment and stowing it
Comments related to this report
gerardo.moreno@LIGO.ORG - 00:56, Thursday 18 April 2013 (6120)
BS optical lever periscope installed, is set 7.5 degrees below horizontal.  3 photos attached, BS elliptical baffle from AR side, a comparison of the BS optical lever periscope (before and after photos), and a view of the installed periscope.
Images attached to this comment
thomas.vo@LIGO.ORG - 10:50, Wednesday 17 April 2013 (6111)
Jim W. Thomas V.

We have removed the locking brackets on the ITMY Elliptical baffle so it is fully suspended (and rather vulnerable).  We left the ITMX Elliptical baffle with the brackets still attached in case any other alignment work or modifications needed to be done.  If it is decided that ITMX's brackets should be taken off, it will be done as well.
jim.warner@LIGO.ORG - 10:31, Thursday 18 April 2013 (6123)

While I was in chamber for Thomas' work, I did a survey to see if any tools had been left in any of the usual nooks and crannies. I didn't find anything, so I think the chamber is clear for close up. I will be in again, probably tomorrow, to wipe down the floor and will do another check.

H1 SEI
jim.warner@LIGO.ORG - posted 16:12, Tuesday 16 April 2013 (6105)
SEI experiment at HAM3, please be careful

Seismic is currently running an experiment at HAM3 to determine whether we want to use more viton on the HAM ISI. This means there are 3x 10kg masses that are not bolted down on the optical table. These masses are sitting on viton pads, while Hugo runs a transfer function. If sub-systems are entering HAM3, please watch out for these stacks, as moving them could disturb the balance of the ISI. The relevant stacks are pretty obvious as I put the old mounting bolts in the top masses, to keep the weight properly distributed, as pictured.

Images attached to this report
LHO General
cheryl.vorvick@LIGO.ORG - posted 16:07, Tuesday 16 April 2013 (6102)
Ops:
- praxair
- DAQ reboot
- IAS in BSC2
- viewports going on the spool near HAM3 - work will continue tomorrow/this week
- AOS in BSC2
- oplevs working in BSC2
- dust monitor 14 restarted for H2 PSL enclosure
- dust monitor code upgrade being tested on OSB optics lab dust monitors
- pcal work in H2 PSL enclosure - done for today
H1 AOS
douglas.cook@LIGO.ORG - posted 15:55, Tuesday 16 April 2013 - last comment - 18:04, Tuesday 16 April 2013(6104)
BS Baffle alignment issues
The Y-Arm elliptical baffle is aligned within spec. < 3mm lateral and vertical

However, the X-arm continues to give us mounting errors. This may require the mounting base to have existing holes elongated in order to mate up with the threaded holes on the stage "0" or at least an investigation into why we are unable to fit it up in its aligned location. 

If holes need to be slotted we will loose a week with the dissembling, modifications, clean and baking reassembly and installation.
A week longer for the spool to be out.

Another option may be that we can remove the baffle modify it and reinstall and align it just prior to installing the ITMx while we have an open path.

I will notify Calum, Lisa, Mike Smith, Mike Landry and Brian as LLO may see the same problems
Comments related to this report
gerardo.moreno@LIGO.ORG - 17:54, Tuesday 16 April 2013 (6106)
Items to remove from ITMY elliptical baffle:
- 1 Variable Height Adjustment Bracket (D1102321)
- 1 Transport, Locking, ACB (D1101285)
- 10 1/4 x 20 bolts and washers, holding both items above

The ITMY elliptical baffle was left locked, due to the possibility of staff going in chamber in the near future, the flexure that suspends the baffle is very small and fragile, vulnerable to twisting forces.
Images attached to this comment
gerardo.moreno@LIGO.ORG - 18:04, Tuesday 16 April 2013 (6107)
Photos of issue with ITMX Elliptical baffle, photos were taken as the baffle sat within tolerance, but there was no clearance for the mounting bolts, since we only see a little bit of the mounting holes.
Images attached to this comment
H1 AOS
keita.kawabe@LIGO.ORG - posted 13:22, Tuesday 16 April 2013 (6101)
Does HAM3 oplev mirror interfere with POP/ALS path? Probably not.

Memo to self:

Since the HAM3 oplev mirror was installed after the POP/ALS path alignment was done, and since Thomas wasn't aware that there is a beam path there when he installed the oplev mirror, I asked Cheryl to check if the oplev mirror mount is occulting the POP/ALS path next time she goes to HAM3.

If both oplev mirror and POP/ALS steering mirror are at the location specified by D0901094, it should be OK.

H1 SEI
hugo.paris@LIGO.ORG - posted 10:04, Tuesday 16 April 2013 - last comment - 10:15, Tuesday 16 April 2013(6099)
HAM3-ISI - Recent Transfer Functions Look Good

We ran transfer functions on HAM3-ISI over the weekend. They look good and clean. They are in good agreement with what we measured prior to the IMC test in December 2012. 

Transfer functions are attached.

Note: one can notice that the amplitude is going up in higher frequencies, on the most recent measurements (GS13s). This is due to the fact that the sample rate at which the Actuation Signals are stored on the DAQ was divided by two (now 2k), while it remained the same on the GS13s (4k), since previous measurements. 

Non-image files attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 10:15, Tuesday 16 April 2013 (6100)

Scrapper Baffles were installed for the transfer functions that ran over past weekend.

Displaying reports 80201-80220 of 86139.Go to page Start 4007 4008 4009 4010 4011 4012 4013 4014 4015 End