Reports until 11:50, Friday 12 April 2013
H1 SUS
betsy.weaver@LIGO.ORG - posted 11:50, Friday 12 April 2013 - last comment - 11:57, Friday 12 April 2013(6054)
BS-HR FC has major problems

Today, Travis pulled the FC sheet on the BS optic, in prep for final SUS pointing measurements now that the SEI actuator housings have been attached.  However, the sheet did not come off cleanly and there are numerous bits of very thin FC in the center of the optic, specifically where the thin windows were.  As well, there is a full circle of haze where one of the thinner FC windows was pulled off at the 3 o'clock position.  So, we sprinted to get the BS FC spray cone cleaned (no time for full class B at this point, but these are a tool that do not touch hardly anything so we're going with it) and will attempt a recleaning this afternoon.  Note, I can't leave the FC sheet on because IAS/AOS need to see through the BS in order to look at the position of the elliptical baffle boxes (shown in the back ground of many pictures linked below).

Recall that the FC-HR sheet originating from CIT many months ago looked like this:

Images attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 11:53, Friday 12 April 2013 (6055)

And here's after the FC was removed (using many minutes of N2 deionizing flow for particulate reduction):

Images attached to this comment
betsy.weaver@LIGO.ORG - 11:56, Friday 12 April 2013 (6056)

And here's the picture of the ~3" circle of FC residue (???) at the 3" position.  Interestingly, there was another 3" window at the center of this window and we could not see any such haze left from that window!  There are also a few strips of FC shown at the edge of the optic in this picture.

Images attached to this comment
betsy.weaver@LIGO.ORG - 11:57, Friday 12 April 2013 (6057)

Note, I do not anticipate the FC coning to go smoothly this afternoon since Margot, Kate and I ran into some issues with the small cone we used in HAM2/3 and this is a new unit which is being used for the first time for the BS.

H1 AOS
keita.kawabe@LIGO.ORG - posted 11:01, Friday 12 April 2013 (6053)
EY viewports are good

I and Joe went to EY and checked the viewports there, and everything is good.

BSC6: 4/4, all good.

H2 EY adapter A-17B: 5/4, we have one viewport more than we need.

H1 SUS
arnaud.pele@LIGO.ORG - posted 11:00, Friday 12 April 2013 (6051)
MC1 Phase 3a passed

MC1 transfer functions ran last night before closing HAM2 chamber look very good.

Measurements can be found attached :

The svn will be updated by the end of the day when measurements will be done

Non-image files attached to this report
H1 ISC
sheila.dwyer@LIGO.ORG - posted 01:10, Friday 12 April 2013 (6050)
ISCT1 work
Tonight Kiwamu and I started aligning the doubling path on ISCT1, first Kiwamu locked down the table legs and I moved the periscope about 2 inches to the north, and centered the beam as well as I could on the mirrors and leveled it.  The beam was large enough to clip on the one inch mirrors so we put a f=600  2 inch cvi lens right after the bottom periscope mirror.  We noticed that there are ghost beams coming from both the 5% reflector and the mirror after it; changing the polarization did not seem to change the power in the ghost beams.  
After adding an iris we tried to measure the beam profile using the pick off for the DC PD path, but saw that the beam is non gaussian. We checked the beam profile right after the 2 inch lens to make sure the 1 inch mirrors are not at fault, and the beam is still non gaussian when there are no 1 inch mirrors in the path.   

H1 SUS
arnaud.pele@LIGO.ORG - posted 20:23, Thursday 11 April 2013 - last comment - 18:18, Friday 12 April 2013(6049)
MC1 MC2 MC3 PRM PR3 Phase 3a transfer functions

Starting several rounds of transfer functions overnight for phase 3a testing prior closing HAM2 HAM3 chamber.
Measurements will run until tomorrow afternoon, and will be paused if needed to go in chamber.

Comments related to this report
arnaud.pele@LIGO.ORG - 18:18, Friday 12 April 2013 (6070)

all suspensions passed phase 3a testing prior to ham2/ham3 close up. plots will be updated on monday

H1 SUS
travis.sadecki@LIGO.ORG - posted 19:56, Thursday 11 April 2013 (6048)
SUS closeout work in HAM2 and 3

Arnaud P., Travis S., Betsy W.

Today, we removed First Contact from the HR surfaces of  PRM, MC1, MC2, and MC3.  We then resuspended these suspensions, with the addition of resuspending PR3 which had been locked only for SEI work.  All EQ stops and lock nuts were set.  Arnaud is running Phase 3a TFs overnight.  

LHO General
patrick.thomas@LIGO.ORG - posted 18:42, Thursday 11 April 2013 (6047)
plots of dust counts
Attached are plots of dust counts requested from 5 PM April 10 to 5 PM April 11.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 18:28, Thursday 11 April 2013 (6046)
dust monitor at end X
I drove out to end X this morning to investigate why communication was lost with the dust monitor there yesterday afternoon. While I was there I turned off the audible alarms for it. It is in the clean room over BSC5, but the clean room is off. I ended up having to restart the IOC to restore communication.
H1 SEI
hugo.paris@LIGO.ORG - posted 18:21, Thursday 11 April 2013 - last comment - 10:50, Thursday 18 April 2013(6045)
HAM2-ISI - Lockers/Balancing

Mitch, Jim, Hugo,

HAM2-ISI was repayloaded, rebalanced, and its lockers (all) were adjusted. We gave HAM2 back to SUS so they can proceed with testing.

 CPS readouts (counts) with the ISI locked, and unlocked, are displayed below.

  Locked Unlocked Shift
H1 -3355 -2861 494
H2 -2622 -2604 18
H3 -121 -713 592
V1 344 709 365
V2 -436 -534 98
V3 -364 -820 456

Even though they are a bit mis-centered (away from 0cts), CPS Targets are far from contacting the sensor. We will leave the CPSs un-zeroed and use a bias in the control loop, as we have done so far.   

Cables rubbing against the chamber/support tubes could be an issue for HEPI commissioning. We took care of dressing the cables away from the chamber and the support tubes, as we could without unplugging anyone (See attached Pictures). It is good practice to always adjust installed cables so they are cleanly dressed, away from the chamber and the support tubes, before connecting them to a feedthrough.

Images attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 10:50, Thursday 18 April 2013 (6125)

Aluminium straps tend to come off. Mitch replaced them with peak zip ties. Picture attached

Images attached to this comment
H1 CDS
david.barker@LIGO.ORG - posted 17:43, Thursday 11 April 2013 (6044)
h1seib3 connected to IO Chassis and IOP model ran for the first time

WP 3803

We powered up the SEI BSC3 IO Chassis for the first time this afternoon. DC power, Timing and One Stop cables were attached.

I created a h1iopseib3 model (copy of h1iopseib2) and we ran this model after verifying the correct number of ADC, DAC and BIO cards were being seen. The system as added to the Dolphin master's configuration.

I have added h1iopseib3 to the CDS Overview MEDM screen. The raw ADC counts MEDM screens can now be used by Ben, Richard and Filiburto for tomorrow's rack checkout work.

I'll keep this workpermit open until this system has been connected to: the DAQ; the alarm system; burt safe.snap; and its IOP SUS Watchdog function has been tested.

H1 SEI
jim.warner@LIGO.ORG - posted 17:19, Thursday 11 April 2013 (6042)
BSC2 HEPI Actuators done

GregG, JimW

BSC2's HEPI actuators were finished up today. Dial indicators suggest a uniform change in height of ~+.1mm and a small cw rotation from our good position on the 9th, and overall not much worse than yesterdays numbers. We still need to set up IPS's (a quick adjustment of a few dials) , but otherwise HEPI is done.

H1 AOS
keita.kawabe@LIGO.ORG - posted 16:53, Thursday 11 April 2013 - last comment - 10:56, Friday 12 April 2013(6036)
Viewport (non)readiness for HIFO test in the LVEA (Joe DeRenzis, Keita)

We've  checked the status of viewports that are necessary for HIFO in the LVEA in the morning. We haven't checked if correct viewports are in, only the number and positions of the viewports. 

We've found that total of 10 viewports are still missing.

Also, since we don't have ITM baffle, it might help to add a camera viewport for IY (BSC1) from the HR side just under the illuminator, i.e. G2. In  OAT we couldn't tell from the spool camera view if the beam is centered on ITMY or not simply because the camera on the IY Adapter was too far (though a good zoom lens would have helped).

Tomorrow Joe will go through the inventory and hopefully find the right ones. We'll also have a look at EY viewports.

Edit: It's already tomorrow from yesterday's point of view, and we confirmed that EY viewports are all there.


HAM1: All good, 7 called for / 7 installed. Note that HAM1W and HAM1E doors are physically labeled 'HAM2W' and 'HAM2E' for historical reasons. I'll use Sharpie to correct the problem if it's not fixed soon.


HAM2: All good, 18/18. HAM2W and HAM2E doors are physically labeled 'HAM1W' and 'HAM1E' bla bla. Sharpie bla.


HAM3: All good, 4/4.


WAMCA1 (MC tube attachment by HAM2): 2/3. One missing. Also one is using a different location.


WAMCB1 (MC tube attachment by HAM3): 2/7. Five missing.


IY Adapter WA-1F: 2/3. One missing.


BSC2 (BS): 1/3. Two missing.


BSC1 (IX): 1/2. One missing.

Comments related to this report
keita.kawabe@LIGO.ORG - 16:58, Thursday 11 April 2013 (6037)

WAMCA1 pictures. First one is taken from the East, showing that nothing is there though there should be video PR2 at least.

 The second one is from the West, showing Video MC2 (middle) and OptLev HAM3 (displaced from the east bottom to the west bottom).

Images attached to this comment
keita.kawabe@LIGO.ORG - 17:01, Thursday 11 April 2013 (6038)

WAMCB1 pictures. The first one is the east side showing nothing, but there should be OptLev PR3 OUT, Video MC1, Video PRM and OptLev PR3 IN.

The second one is the west side showing two of three viewports that should be there. The one missing is Video PR3 at the top.

Images attached to this comment
keita.kawabe@LIGO.ORG - 17:06, Thursday 11 April 2013 (6039)

IY adapter pictures. The first one is from the north side showing OPTLEV ITMY-IN at the bottom, which is good.

The second one is the south side which shows OPTLEV ITMY-OUT at the top, but not ITMY Video viewport in the middle.

Images attached to this comment
keita.kawabe@LIGO.ORG - 17:14, Thursday 11 April 2013 (6040)

BSC2 pictures. It's kind of hard to see, but the four pictures show four viewport columns in NE, NW, SW, SE.

NE has OptLev BS, which is good.

NW is totally closed, which is how it should look.

SW is supposed to have illumitator at the top and BS Video in the middle, but they're not there.

SE is totally closed, which is how it should look.

Images attached to this comment
keita.kawabe@LIGO.ORG - 17:17, Thursday 11 April 2013 (6041)

BSC1 picture from the south side. Illuminator is at the top left, which is good.

ITMY-CP Video is missing from the middle right. It's not a tragedy if we don't have this one for HIFO.

Images attached to this comment
thomas.vo@LIGO.ORG - 10:56, Friday 12 April 2013 (6052)
The HAM3 OptLev does receive the output beam out of VP7 on WAMCA1 so that works fine. 
H1 CDS
patrick.thomas@LIGO.ORG - posted 17:45, Tuesday 26 March 2013 - last comment - 17:51, Thursday 11 April 2013(5893)
troubleshooting h1ecatc1
Chris, Daniel, Patrick

In short: Swapping the real time Ethernet card in the h1ecatc1 computer appears to have resolved a problem with it periodically crashing and restarting.


Last week and possibly the week before, the computer running the EtherCAT system at the corner station, h1ecatc1, had been spontaneously crashing and restarting. Each time this occurred there was a message upon login that Windows had recovered from an unexpected error.

My first inclination was that one of the installed programs, OpenOffice.org, which periodically asked for Java updates, was causing the problem. To this end I removed this application. I also removed some others that I can not recall at this time. However, the problem persisted.

Looking at the Windows minidump file, it appeared that the issue was with one of the TwinCAT processes. The system manager was also reporting CRC errors and lost frames. I attempted to narrow down the problem by systematically disconnecting EtherCAT chassis. I removed the fiber connected to the test setup of end X in the MSR. This fiber was broken on one end, and I destroyed it. I also disconnected the fiber to end Y. I tried various combinations of the remaining chassis in the H1 electronics room. At one point suspecting the ISC Common Chassis, I swapped it with one from H2. While it may have appeared at one point that things were running better with fewer chassis attached, the problem eventually returned.

I also tested the fiber connection from the MSR to the H1 electronics room. I removed the fiber connection from the ISC Common Chassis in the H1 electronics room and attached it to a communications tester that Daniel had made. With this setup, the h1ecatc1 computer was connected to the Corner MSR Chassis and this was connected by the existing fiber to the communications tester. This appeared to work. Nevertheless, the problem persisted after reconnecting to the chassis. However, it was realized that the orange multi mode fiber patches from the Beckhoff chassis in the MSR and H1 electronics room did not match the type of fiber running between these rooms. These patches along with the fiber in the chassis itself should be swapped for 50/125 (aqua). This has not been done yet.

Last Friday (March 23) I looked closer in the system manager at the diagnosis for just the Realtime Ethernet card. I had the impression that it may have been reporting errors itself, and decided to try and swap it. I replaced it from the slow computer in the rack in the computer user's room. It appeared to fix the CRC errors and I left it running over the weekend. It was still running on Monday morning and appears to have done the trick.

Caveat: My memory is somewhat fuzzy and the above steps may not have occurred in exactly the order described.
Comments related to this report
patrick.thomas@LIGO.ORG - 17:51, Thursday 11 April 2013 (6043)
My handwritten notes:

1:00 PM lost PSL environment channels, H1ECATC1 restart?
jucheck.exe, Oracle America, Inc.
"C: Program Files  Common Files  Java  Java Update  jucheck.exe"
 -auto -scheduled
H1:SUSH34 <- not sure what this means, if even related
restarted again trying to browse to EPICS target directory
C: Windows  Minidump  030513-30139-01.dmp
C: Users  controls  AppData  Local  Temp  WER-55941-0.sysdata.xml
 removing OpenOffice.org 3.3
 remove Java 7 Update 11
 remove Adobe Flash Player 11 ActiveX

burtrestored 2013/03/04/00:00