We've checked the status of viewports that are necessary for HIFO in the LVEA in the morning. We haven't checked if correct viewports are in, only the number and positions of the viewports.
We've found that total of 10 viewports are still missing.
Also, since we don't have ITM baffle, it might help to add a camera viewport for IY (BSC1) from the HR side just under the illuminator, i.e. G2. In OAT we couldn't tell from the spool camera view if the beam is centered on ITMY or not simply because the camera on the IY Adapter was too far (though a good zoom lens would have helped).
Tomorrow Joe will go through the inventory and hopefully find the right ones. We'll also have a look at EY viewports.
Edit: It's already tomorrow from yesterday's point of view, and we confirmed that EY viewports are all there.
HAM1: All good, 7 called for / 7 installed. Note that HAM1W and HAM1E doors are physically labeled 'HAM2W' and 'HAM2E' for historical reasons. I'll use Sharpie to correct the problem if it's not fixed soon.
HAM2: All good, 18/18. HAM2W and HAM2E doors are physically labeled 'HAM1W' and 'HAM1E' bla bla. Sharpie bla.
HAM3: All good, 4/4.
WAMCA1 (MC tube attachment by HAM2): 2/3. One missing. Also one is using a different location.
WAMCB1 (MC tube attachment by HAM3): 2/7. Five missing.
IY Adapter WA-1F: 2/3. One missing.
BSC2 (BS): 1/3. Two missing.
BSC1 (IX): 1/2. One missing.
Modified capacitive position sensors per E1300251 for BSC2. This was to address a high frequency oscillation in the return path. Filiberto Clara
CPS Coarse: SN 13201, 13183, 13419, 13528, 13454, and 12953 Resistor R55 was replaced with 51.1 Ohm. CPS Fine: SN 13230, 13238, 13418, 13439, 13450, and 13452 Resistor R55 was replaced with 51.1 Ohm. Resistor R81 was replaced with 1.47K Ohm.
Looking at PR2 transfer functions ran yesterday night, an extra resonnance appears at 2.8 Hz for M1 pitch to pitch transfer function when comparing it to the model and phase 3a testing transfer functions ran on december 2012.
Betsy and Travis are investigating to find its source.
Attached is the pdf with all DOF and comparisons with LHO measurements ( "allhstss[...]") with the following legend :
The second pdf ("2013-04-10[...]") shows -in addition to the comparison between measurement and model for every DOF- the coupling between DOF and individual OSEMs which might be helpful for understanding what's going on.
We decided to approve phase 3a for PR2, and postpone the investigation for next time the chamber we'll be open.
For the 35W beam.
Found BOTH cds file servers in read-only bad states this morning. Powered off and disconnected power from cdsfs0 and cdsfs1, then powered back up. This is the only way we've found to reliably reset the RAID controller on these computers.
Here are the crash times:
| cdsfs0 | 09:42 |
| cdsfs1 | 00:03 |
It appears that cdsfs1 crashed while rsync'ing cdsfs0 (cron job runs at midnight), and that cdsfs0's crash was coincidental.
I attach photos showing the serial number side of the ITMY elliptical baffle and the ITMX elliptical baffle, respectively, with the beam splitter in the background to document their orientation.
As a result of the power increment [1] we now have 4.76 mW of the infrared light at the field rack, which used to be 2.4 mW in the morning [2]. Yeah.
- - - - Measured Beam Powers
Incident on the refcav 21.4 mW
Incident on the fiber = 8.91 mW
The fiber power at the field rack = 4.76 mW
[1] LHO alog 6017 "Power into reference cavity increased"
[2] LHO alog 6103 "Coupling into ALS fiber on PSL table"
Gerardo, Gerardo Jr., Symon, Keita, Sheila, Kiwamu
We moved ISCT1 closer to HAM1 at its west side, installed a beam duct and confirmed that the PSL sample beam nicely goes through the viewport to ISCT1.
We are ready to align the optics on ISCT1 for the doubling test to generate the green light.
ISCT1 shift:
The ISCT1 enclosure which had been put afar from the HAM1 chamber was rolled closer to HAM1. Before moving it the clean room was also rolled toward south to accommodate ISCT1 as the clean room was too close to let ISCT1 go in. At the moment the distance between HAM1 and ISCT1 is that one person can just get through between the HEPIs and the enclosure. Also, as a part of the preparation of the laser barriers we put two black metal panels at the north side of the enclosure. The panels were wiped before they got in the clean room.
Beam spot position check :
Then we transitioned the LVEA to laser hazard for checking the spot position at the lower right viewport and the enclosure hole. At the HAM1 viewport the beam was at almost the center of the guillotine guard (as we aligned the in-vac mirror the other day) and slightly off in mainly the horizontal direction by 1 cm toward north, which is small enough comparing with the viewport diameter. At the enclosure hole it was off from the center by 4-ish cm toward south and by 4-ish cm higher. This is fine as the hole diameter is 10". We are satisfied with this alignment and hence there is no need to steer the beam with the in-vac steering mirror. At the moment the beam doesn't hit the upper periscope mirror in the ISCT1 enclosure but the beam height looks already perfect. So we just need to translate the periscope by ~ 4 cm to catch the beam, which is within our expectation.
Installation of duct:
We installed a beam duct and it now connects the viewport and the enclosure hole. This is exactly the same duct style as that we installed for IOT2L. The yellow cover of the viewport was removed and put right under the HAM1 door. We didn't remove the guillotine because we didn't find the dust cover which is supposed to cover the guillotine slit when it is absent. Although we found one dust cover in the stash nearby HAM3, this looked too big. So we left the guillotine in.
ISCT1 HEPA
We wiped the interior of the table before the enclosure was moved. We let the HEPA of ISCT1 run at its lowest speed to avoid sending dusts from the inside of the enclosure. Since the enclosure is almost entirely in the clean room probably it may not need to have the HEPA running. If people think it is doing nothing but blowing up dusts we can shut the HEPA off.
Attached are plots of dust counts requested from 5 PM April 9 to 5 PM April 10. Odd drop off in counts in the beer garden (LVEA 5) at around 1 AM.
Figure 1 shows beam spot views associated with the BS. I use these to look for potential scattering problems; the camera and flash is placed very close to the center of the optic where the beam spot will be. The flash mimics the scattering of interferometer light from the beam spot and lights up regions that will retroreflect interferometer light back to the beam spot, where it can recombine with the main beam to produce scattering noise. Of course the technique is limited by different angular distributions of scattered IFO light and light from the flash, as well as by color differences, but it gives a rough idea. I worry a bit about how bright the ITMY cage is, as viewed from the BS beam spot.
Kyle and I left a GNB bellows inside one of the small cleanrooms in the LVEA, located by the North wall of the East bay. Please do not remove from under cleanroom, if this item is on the way please let us know.
I updated the h1cds alarm handler files to include the front ends which have been added recently. The alh config files alarm on CPU MAX for IOP and user models, and STATE_WORD for the IOP model. Not all iop safe.snaps have been completed to set the STATE_WORD alarms.
I also updated the h1alarmmanager.db EPICS database for the alarm manager system, and its associated MEDM screen (see attached image).
Kiwamu, Michael R
We increased the power going into the ref cav to get more light into the ALS fiber pick off. We now have about 23 mW going in. We ran a transfer function and found a lot of noise around 380 kHz, very close to the UGF. To get rid of this we decreased the common gain to 2 dB, giving a gain margin of 2dB. The UGF is now at 200 kHz.
Additionally, the PD in transmission of the ref cav was saturating, so I put an ND 0.3 filter infront of it. This was the lowest one I could find, and it is now reading ~ 3V.
I found the FSS couldn't recover from an oscillation event and had to decrease the fast gain to 6 dB for it to get back.
Kate G, Margot P, Travis S, Betsy W
MC2 has had its blade tip EQ stops replaced with the new shorter version. HAM2 and 3 have been fully photographed for contamination control efforts. Spray cones for both the HSTS and HLTS were assembled after some minor modifications were made on the fly. MC2 has had its first spray on First Contact layers applied. This required moving the baffle in front of the suspension in order to get the spray cone in place and to make room for a hand and spray bottle. Its position was marked with extra dog clamps and will be returned upon completion of cleaning. This work will continue tomorrow with First Contact being sprayed onto the remaining MC and PR suspensions in both chambers. Additionally, the BS has had its IAS thin-coated First Contact reinforced for its upcoming removal necessitated by baffle alignment.
Betsy writing: Note, we are only FC cleaning the 3 MC-HR surfaces, and the PRM-HR surface, as per COC instruction.
Attached are plots of dust counts requested from 5 PM April 8 to 5 PM April 9. There seems to be a large spike in > .3 micron counts at end Y from ~ 2 AM - 3 AM, and a smaller corresponding spike at end X.
The times appear to be wrong towards the ends of these plots. There should be a gap in the data due to a DAQ restart. This can be seen from the fact that the number of minutes does not go to 1440. This was realized in comparing these plots to those produced by dataviewer.
WAMCA1 pictures. First one is taken from the East, showing that nothing is there though there should be video PR2 at least.
The second one is from the West, showing Video MC2 (middle) and OptLev HAM3 (displaced from the east bottom to the west bottom).
WAMCB1 pictures. The first one is the east side showing nothing, but there should be OptLev PR3 OUT, Video MC1, Video PRM and OptLev PR3 IN.
The second one is the west side showing two of three viewports that should be there. The one missing is Video PR3 at the top.
IY adapter pictures. The first one is from the north side showing OPTLEV ITMY-IN at the bottom, which is good.
The second one is the south side which shows OPTLEV ITMY-OUT at the top, but not ITMY Video viewport in the middle.
BSC2 pictures. It's kind of hard to see, but the four pictures show four viewport columns in NE, NW, SW, SE.
NE has OptLev BS, which is good.
NW is totally closed, which is how it should look.
SW is supposed to have illumitator at the top and BS Video in the middle, but they're not there.
SE is totally closed, which is how it should look.
BSC1 picture from the south side. Illuminator is at the top left, which is good.
ITMY-CP Video is missing from the middle right. It's not a tragedy if we don't have this one for HIFO.