Displaying reports 80821-80840 of 86123.Go to page Start 4038 4039 4040 4041 4042 4043 4044 4045 4046 End
Reports until 13:25, Tuesday 12 February 2013
H1 SEI
james.batch@LIGO.ORG - posted 13:25, Tuesday 12 February 2013 (5472)
Added HEPI Pump Controller to Slow Controls Network
Cyrus Reed, Jim Batch

Run Cat. 5e cable for HEPI pump controller in Mechanical room mezzanine. Connect pump controller to network switch, reconfigure network settings in the pump controller to connect to the slow controls network.  Controller was NOT rebooted or restarted during this reconfigure.

Rename pump controller to h1hpipumpctrll0, modify user accounts to conform to CDS system.  Mount /opt/rtcds, /opt/rtapps, and /opt/cdscfg directories from h1boot to the pump controller.

X1 DTS
james.batch@LIGO.ORG - posted 12:50, Tuesday 12 February 2013 (5471)
Reconfigure x1dc0 to use additional mx 10GE card
For x1dc0, removed the 3 slot PCIe riser card, installed a 4 slot PCIe riser.  Installed 3 10GE fiber cards, 1 IRIG-B card.  2 of the 10GE cards are configured for mx communication to the x1daq switch to allow testing of daqd software on multiple paths.  The x1daq switch is configured for 1 vlan for both 10GE fibers and all the front end computers.  Through experimentation, the following order of cards has been determined:

(top to bottom)

10GE mx :0
10GE eth2
10GE mx :1
IRIG-B

Also restarted x1nds0, wouldn't allow ssh login.
H1 SUS
arnaud.pele@LIGO.ORG - posted 10:57, Tuesday 12 February 2013 - last comment - 16:45, Friday 18 October 2013(5468)
B&K Hammer Measurement
Arnaud P. Betsy W. 

Did B&K hammer measurements on Friday feb 8th on the BeamSplitter that will be installed in BSC2. 
Config: BSC-ISI Unlocked, QUAD Unlocked, Baffles ON, Vibration Absorbers ON, Damping ON.

Attached, pictures describing the position of hammer impacts, and accelerometer + corresponding pulse files.

Non-image files attached to this report
Comments related to this report
stuart.aston@LIGO.ORG - 14:26, Thursday 21 February 2013 (5551)
Raw data has been exported from the B&K Pulse files, in accordance with the procedure outlined in the SUS Operations Manual (see How to do B&K Hammer Testing).

Exported ASCII data files have been committed to the SUS svn at the following location, ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/BandK$, these files include the following (n.b. files have been renamed to comply with convention detailed in the Op's Manual) :-

SimpleHammerDisplay3-BS-Bottom-SUSunlocked-ISIunlocked-VAfitted-Yimpact.pls
SimpleHammerDisplay3-BS-Bottom-SUSunlocked-ISIunlocked-VAfitted-Yimpact.txt
SimpleHammerDisplay3-BS-BottomLeft-SUSunlocked-ISIunlocked-VAfitted-Ximpact.pls
SimpleHammerDisplay3-BS-BottomLeft-SUSunlocked-ISIunlocked-VAfitted-Ximpact.txt
SimpleHammerDisplay3-BS-BottomRight-SUSunlocked-ISIunlocked-VAfitted-Ximpact.pls
SimpleHammerDisplay3-BS-BottomRight-SUSunlocked-ISIunlocked-VAfitted-Ximpact.txt
SimpleHammerDisplay3-BS-TopLeft-SUSunlocked-ISIunlocked-VAfitted-Ximpact.pls
SimpleHammerDisplay3-BS-TopLeft-SUSunlocked-ISIunlocked-VAfitted-Ximpact.txt
SimpleHammerDisplay3-BS-TopLeft-SUSunlocked-ISIunlocked-VAfitted-Yimpact.pls
SimpleHammerDisplay3-BS-TopLeft-SUSunlocked-ISIunlocked-VAfitted-Yimpact.txt
SimpleHammerDisplay3-BS-TopMiddle-SUSunlocked-ISIunlocked-VAfitted-Ximpact.pls
SimpleHammerDisplay3-BS-TopMiddle-SUSunlocked-ISIunlocked-VAfitted-Ximpact.txt
SimpleHammerDisplay3-BS-TopMiddle-SUSunlocked-ISIunlocked-VAfitted-Yimpact.pls
SimpleHammerDisplay3-BS-TopMiddle-SUSunlocked-ISIunlocked-VAfitted-Yimpact.txt
SimpleHammerDisplay3-BS-TopRight-SUSunlocked-ISIunlocked-VAfitted-Ximpact.pls
SimpleHammerDisplay3-BS-TopRight-SUSunlocked-ISIunlocked-VAfitted-Ximpact.txt
SimpleHammerDisplay3-BS-TopRight-SUSunlocked-ISIunlocked-VAfitted-Yimpact.pls
SimpleHammerDisplay3-BS-TopRight-SUSunlocked-ISIunlocked-VAfitted-Yimpact.txt

The above B&K data has been processed using v12 of the "BandK_plot.m" Matlab script, available in the /ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools$ directory.

The merged plot attached below shows:-
pg1 - Y response of the structure to Y hammer impact excitations at various locations, from 1Hz to 400Hz.
pg2 - X response of the structure to X hammer impact excitations at various locations, from 1Hz to 400Hz.
pg3 - X response of the structure to X hammer impact excitations at various locations, ZOOMED IN from 50Hz to 400Hz.

n.b. hammer impact locations are viewable in the attachment to the original aLOG entry above see "Hammer_Impacts.pdf".   
Non-image files attached to this comment
arnaud.pele@LIGO.ORG - 18:27, Wednesday 25 September 2013 (7873)

For acceptance review, I reprocessed the data for the beamsplitter, after seeing a legend mismatch between the plotted results and the raw data from PULSE software.
Therefore the attached results below are the ones to look at, and are following the accelerometer axis convention represented on the last attachement

(1) BandK_results_X_Exc.pdf

(2) BandK_results_Y_Exc.pdf

(3) Picture of BS with axis convention and hammer impact location

The X and Y hits have been chosen to correspond to the "Top Middle" hits on the picture

Non-image files attached to this comment
arnaud.pele@LIGO.ORG - 16:45, Friday 18 October 2013 (8173)

Those results in X to X (blue of 1st pdf) and Y to Y (green of 2nd pdf) are not showing any high Q resonnances below 150Hz, meaning the vibration absorbers are working as expected, and the test passed succesfully.

LHO General
patrick.thomas@LIGO.ORG - posted 19:06, Monday 11 February 2013 (5467)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot requested from 5 PM Feb. 10 to 5 PM Feb 11. Also attached are plots of the modes to show when they were running/acquiring data.

Data was taken from h1nds0.
1440.0 minutes of trend displayed
Non-image files attached to this report
H1 DAQ
david.barker@LIGO.ORG - posted 17:22, Monday 11 February 2013 (5466)
h1fw1 back after Sunday Afternoon crash

Dan M investigated the MSR SATABOY failure which occured at 15:23 Sunday afternoon. The system was performing a weekly maintenance task and crashed, it is a mystery why this happed this weekend. He took opportunity of the stopped system to perform the same firmware upgrades on the Sun box h1ldasgw1 as he did with h1ldasgw0 last week. The h1fw0 system is back up and running.

We noticed a mismatch in min trend saving periods, 60 mins for h1fw1 and only 30 mins for h1fw0. I changed h1fw0 to use 60 mins which will be applied on the next daq restart.

H1 PSL
michael.rodruck@LIGO.ORG - posted 17:02, Monday 11 February 2013 (5463)
Fans back on

I turned the HEPAs, AC units, and make up air back to 100%. I increased the temperature of the AC units from 20 C to 21 C as this is the temperature the room seemed to settle at. We'll try another test in the future with this new setting to see how the room responds.

LHO VE
kyle.ryan@LIGO.ORG - posted 16:21, Monday 11 February 2013 (5462)
~1130 hrs. local -> Started "slow" vent of HAM2-HAM3 volume
HAM2-HAM3 volume 9.1 x 10-7 torr before venting
H1 SUS
betsy.weaver@LIGO.ORG - posted 16:18, Monday 11 February 2013 - last comment - 10:10, Tuesday 12 February 2013(5461)
PR3 optic suspended

With the help of Gerardo 1 and 2, and Deepak, we used the ergo arm to stuff the PR3 optic into the suspension.  We then suspended the mass, adjusting roll and height to within the 1mm tolerance and 1mm.  Official height numbers coming shortly.  Deepak will tweek the top stage BOSEMs into center tomorrow and then we're ready for Phase 2b TFs.

Comments related to this report
betsy.weaver@LIGO.ORG - 10:10, Tuesday 12 February 2013 (5470)

We measured the diameter of the optic to be 265.1mm, while the vendor data posted on the CIT Nebula website shows 264.91 so we're in pretty good agreement.  We tweeked the height of the optic via adding 20g of mass to the top of the top mass, setting the bottom of the optic 26.6mm from the table surface.  This sets the center line of the optic at 158.75mm off of the table surface.  Nominal is 158mm as per the optomech layout drawing for PR3 on HAM2.

LHO General
justin.bergman@LIGO.ORG - posted 16:10, Monday 11 February 2013 (5456)
Ops Summary
LVEA laser safe all day.

Ongoing H1 PSL enclosure environmental alarms all day relating to Robert Schofield's aLog entry from Sunday. Recall that HEPA and AC units are offline in the enclosure. Low differential pressure (LVEA<->PSL anteroom 0.00 inchesH20) and periodic high dust counts (briefly approached 1000 cts for 0.3 microns in the anteroom this morning, now at zero. No dust data for the laser room.)

0845-1000 - Paul F taking power spectra on IMC.
0845 - Doug D D working near H2 enclosure.
0900 - Corey G working around HAM6/Squeezer bay.
0910 - HFD onsite working on fire alarm systems in OSB and LSB, users should receive additional notification before alarms activated.
0930-1530 - Eric A and Chris (Apollo) in LVEA inspecting and working on valving and piping for HEPI systems. (HAM4/6 and BSC3).
1000-1500 - Gregorio to Pasco.
1000 - Apollo moving ERGO arm over beam tube to South Bay.
1030 - Filiberto running cables HAM1-HAM3.
1030 - Patrick and Justin reset remote dust alarm threshold for DST_16 to 1000cts (local alarm threshold unchanged).
1300 - First cleaning of HAM3-BSC2 spool. Justin to LVEA to investigate 80,000 ct (.3) dust alarm at DST_15. Vacuum cleaner had been running next to monitor.
1345 - Corey G to EY.
1430 - Keita pulling a length diode on IOT2L (H1 PSL shutter is closed). 
1545 - Justin reset remote alarm threshold for DST_16 to default values (minor>100, major>200).


H1 CDS
keita.kawabe@LIGO.ORG - posted 15:49, Monday 11 February 2013 - last comment - 17:11, Monday 11 February 2013(5457)
IMC WFS and Length DC interface are not working as they're supposed to

I turned off the LSC RFPD interface chassis (D1102060) for IMC length diode using the switch at the back panel, disconnected the length diode cable, connected a DB9 break out board at the front panel without connecting anything else (but the back panel was still connected to the ADC), switched on/off the chassis (again using the switch at the back) and measured how the +-18V supply for the diodes behave.

To my disappointment, every time I did this test, for about 1ms to 1.5ms there was a window where the negative power was -18V but the positive was basically non-existent (below 5V). It seems as if the negative voltage goes live immediately. See the first picture, the scale is 5V and 1ms/div.

This is the unit that we've been using since the start of IMC installation.

I did the same test for WFS interface (D1101865), and it was only marginally better than the length interface (second picture, same scale as the first one).

This is the unit that replaced the broken unit, but since this one was put into service WFS was connected/disconnected hot.

Switching off was much better for both of these units, basically both of the rails came down slowly at the same time (the last picture, note the slower 4ms/div scale).

During these tests, the only things powered by the chassis were the DC interface cards in the chassis and of course the power protection board itself. 

I don't know if the units are broken, we'll test them further though the change Rich Abbott made to diode boxes will hopefully make this behavior harmless.

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 17:11, Monday 11 February 2013 (5465)

I also tested the LSC interface for LSC (not for IMC), which was never used but was installed in the rack.

This is better than the used units, but the negative power comes in faster than the positive.

Images attached to this comment
H1 PSL
michael.rodruck@LIGO.ORG - posted 15:39, Monday 11 February 2013 (5459)
PSL plots (taken with HEPAs off)

These are taken with the HEPAs in the anteroom and laser room off, with the make up air fan turned to 30%. AC units are off as well.

Non-image files attached to this report
LHO General
bubba.gateley@LIGO.ORG - posted 15:28, Monday 11 February 2013 (5458)
Apollo crew
We flew the ergo arm to the south bay for Betsy. Disassembled the E module and moved to the north side of ham 4, started disassembly of the work platform that was around bsc 1 for install at bsc 2. Need to remove (with approval granted from Hugh) the horizontal hepi accuators on the south side of bsc 3 to allow installation of the work platform section between bsc 2 & 3. These will be unbolted and rolled down will still being secured with the current hepi bolts. (This same thing was done on bsc 2 for some clearance issues.) Also assisted Hugh/Eric with hepi install. 
H1 PSL
michael.rodruck@LIGO.ORG - posted 14:50, Monday 11 February 2013 (5454)
Frontend power monitor fixed

A month ago when we restarted the laser we noticed the frontend power monitor was reading only 6W. This was tracked down to a gain setting that was modified and not entered into the safe.snap file, so when we rebooted the computer frontends for the 2.6 code upgrade the incorrect gain value was entered. I've changed back to the correct setting and updated the safe.snap file, and we are now reading 31W.

H1 IOO
paul.fulda@LIGO.ORG - posted 14:01, Monday 11 February 2013 - last comment - 12:48, Thursday 31 October 2013(5452)
Pre-vent IMC length/frequency noise spectrum

[Kiwamu, Paul]

Just before the vent today we measured new noise spectra for the frequency and length feedback paths.

The 'whitening filters' in the IMC_X path (see Giacomo's LHO alog entry 5311) were not engaged. They were put in the model at LLO in an attempt to combat the digital noise in IMC_X above ~50Hz (see Anamaria's LLO alog entry 5821) but need to be taken account of when plotting the data.

We corrected the IMC_F frequency to length calibration to give the equivalent motion of MC2, instead of the equivalent round trip length change. This has now been edited in the filter bank for the IMC_X path; the FtoL filter has been changed to a DC gain of 5.8465e-14 (dX=df x lambda/(2FSR)). 

Relevant paramters during the measurement:

Common mode gain 20dB

Common mode filters: Compensation and 1st Boost

Fast gain -2dB

Slow path bypassed offsets and filters

MC2 M3 lock gain -1000, engaged filters: 150:4 and CLP100

MC2 M2 lock gain 0.06, engaged filters: 0.01:0.1, 0.03:1, Stab8:2, 300:1 and ELF80

Damping filter: resg and Ellip50 (the filter in IMC_X path was switched to the wresg filter to reflect this change)

Non-image files attached to this report
Comments related to this report
paul.fulda@LIGO.ORG - 15:50, Wednesday 13 February 2013 (5488)

Jeff quite rightly pointed out that there are actually 2 more filter banks in the length path for the IMC which I didn't mention in the above post.

One of these is the H1:IMC_L bank, with the following 3 filters engaged and with Gain=1: antiWhite, roll3notch and bouncenotch.

The other bank is the H1:LSC-IMC bank, with 1 blank filter engaged with Gain=1. I'm not sure yet what the purpose of this bank is but would happy to know if someone else does! I'll try to get  a signal flow chart up here soon, though it may be a little trickier from off-site.

paul.fulda@LIGO.ORG - 12:48, Thursday 31 October 2013 (8337)

I was revisiting this measurement and I thought it might be useful to add the PSL frequency noise requirement line for comparison (see attached).

Non-image files attached to this comment
LHO FMCS
david.barker@LIGO.ORG - posted 11:53, Monday 11 February 2013 - last comment - 14:48, Monday 11 February 2013(5451)
FMCS IOC restarted

The FMCS IOC needed a restart, presumably due to the failure of /ligo on Sat morning.

Comments related to this report
patrick.thomas@LIGO.ORG - 14:48, Monday 11 February 2013 (5453)
I burtrestored it to 2013/02/01/00:00.
H1 PSL
robert.schofield@LIGO.ORG - posted 22:32, Sunday 10 February 2013 - last comment - 11:21, Monday 11 February 2013(5448)
PSL running in science mode

I shut down the HEPAs in the ante room and in the laser room, shut down the 2 ACs (though I could not see their effect, so they could be left on) and set the makeup air at 30%. Overnight the temperature on the table increased by a couple to several degrees. The IMC was still locking, though very poorly. Paul tuned up the alignment  of the IMC and the REFL_DC level returned to better than it had before the change (about 50 counts). The figure shows a comparison of IMC_F  and the accelerometer at the top of the periscope in the two modes.

Non-image files attached to this report
Comments related to this report
jan.poeld@LIGO.ORG - 02:44, Monday 11 February 2013 (5449)
How much overpressure is in the PSL laser room when you run the makeup air at 30%? Do you see an effect from the makeup air at different speed? When I reduced it at LLO I did not see any difference in MC_F.
michael.rodruck@LIGO.ORG - 11:21, Monday 11 February 2013 (5450)

I saw 0.013" of water overpressure from the laser room to ante room.

H1 SEI
hugo.paris@LIGO.ORG - posted 11:02, Friday 08 February 2013 - last comment - 17:30, Tuesday 12 February 2013(5427)
HAM-ISI - Viton Pads Efficiency Test

Viton pads are usually set under the balancing masses of the HAM-ISIs in order to damp resonances at high frequencies (above 100Hz).

The SEI team would like to asses the improvements that the Viton Pads help achieving. To do so, we decided to have viton pads under the balancing masses of the ISIs of LLO's IMC, and to try without those pads here at LHO.

Transfer functions were measured ovenight on LHO HAM3-ISI. We compared those transfer functions with the ones measured at LLO under an equivalent state:

Comparative plots are attached.

Non-image files attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 17:19, Monday 11 February 2013 (5464)

The script which produced the plots mentioned above was re-checked. The curves it displays match with the ouput of the generic commissioning scripts, for both LLO and LHO. 

Data in the 5Hz-200Hz range was retreived and added to the plot. Results are attached.

Non-image files attached to this comment
hugo.paris@LIGO.ORG - 17:30, Tuesday 12 February 2013 (5477)

The results presented above were calibrated and transposed into the cartesian Basis, as performed during the step 3 of the commissioning process of HAM-ISIs.

Narrow peaks can still be seen on LLO's transfer functions. We held off on the installation of the Scraper Baffles here, while they were already on the ISI at LLO, at the time of the measurement. It could be the cause of it.

Once HAM3 chamber is open, we will look at the items installed on the ISI. It should help clarifying the cause those peaks that we did not witness here.

I attached a picture of HAM3 chamber taken on Dec 6th 2012. Pumpdown started on Dec. 21st.

Non-image files attached to this comment
Displaying reports 80821-80840 of 86123.Go to page Start 4038 4039 4040 4041 4042 4043 4044 4045 4046 End