H1 PSL
michael.rodruck@LIGO.ORG - posted 14:28, Tuesday 05 February 2013 - last comment - 16:25, Tuesday 05 February 2013(5374)
PSL Plots

For the 35W laser

In investigating the ISS noise, I tried unlocking the FSS so the mode cleaner had no input to the PSL and took a spectrum. The noise is still there, so I think this rules it out as a noise source, unless they installed some hardware in the outside racks which is loudly humming at 60 Hz. I tried disabling the heater on the PMC which did help clear up the noise around 50 Hz but did not affect the peaks (iss_rpn-005). However, the noise does appear in the HV signal of the PMC when it's unlocked and locked. The peak around 4 kHz shows up in this signal as well, although its position moves by 1-2 kHz. So it looks like it is not the mode cleaner but the PMC causing this noise, maybe in the HV signal.

On the DBB: Rick and I several months back adjusted the lenses in the box to improve the mode matching, using the medm interface. However, we did not save these settings to the safe.snap file and when the DBB was burtrestored it moved the lenses to their old positions. I've updated the values and wrote a new safe.snap file.

Images attached to this report
Non-image files attached to this report
Comments related to this report
michael.rodruck@LIGO.ORG - 16:25, Tuesday 05 February 2013 (5378)

It looks like it is the HV that is carrying the 60 Hz noise. I unlocked the PMC again and disabled the ramp input and temperature loop so there was (I believe) no input to the high voltage, and took a time series plot. There is a clear 60 Hz signal present on this channel I haven't seen before. I do not know where this could be coming from, but I will check with IO/ISC people to see if they installed anything near the rack.

Images attached to this comment
H1 ISC
kiwamu.izumi@LIGO.ORG - posted 14:27, Tuesday 05 February 2013 (5377)
Realignment of the ALS-PSL fiber launcher setup

[Max and Kiwamu]

A few days ago, we found that there was almost no light coming out from the ALS-PSL fiber [1]. This was thought to be a misalignment in the launcher setup on the PSL table.


Today we entered the PSL room and realigned the setup. Although we screwed up the previous alignment at the beginning due to the lack of a right measurement device, at the end we became able to couple 40% of the incident light (Pin ~ 4.6 mW) into the fiber. Note that the best coupling efficiency in the past was 60% and therefore we maybe able to squeeze some more power from it, but we are satisfied with this number at the moment.

[1] LHO alog 4721 "PSL reference cavity transmission picked-off and launched into ALS fiber"
 

H1 CDS
cyrus.reed@LIGO.ORG - posted 14:20, Tuesday 05 February 2013 (5375)
Switch Firmware Updates Complete
The network switch firmware updates scheduled for today under work permit #3697 are complete.  The following switches/updates were applied:

sw-msr-core: Sup7E upgraded to latest maintenance train release IOS-XE 3.4.0 from 3.2.0 (deferred).  Rommon upgraded from 15.0(1r)SG2 to 15.0(1r)SG7.

sw-msr-ops: Upgraded to IOS 15.0(2)SE1 from 12.2(53)SE2, (includes ucode update).

sw-msr-gc: Upgraded to IOS 15.0(2)SE1 from 12.2.(55)SE3, (includes ucode update).

sw-lvea-aux0: Upgraded to IOS 15.0(2)SE1 from 12.2.(55)SE3, (includes ucode update).

sw-msr-servers: Switch installed, (v 15.0(2)SE1).
H1 CDS
david.barker@LIGO.ORG - posted 12:40, Tuesday 05 February 2013 (5373)
Maintenance summary

WP3698: change of h1iopseib6 model to permit up to 10 IPC errors per second from h1susb6. Completed, required restart of h1hpietmy and h1isietmy as well as h1iopseib6.

DAQ was restarted. This caused some 0x2bad mx_stream errors which resulted in a restart of mx_stream on h1sush34, h1susauxh2,h1seib1 and h1susauxb6. h1psl0 data was seen to go bad during these restarts.

The DAQ restart allowed the configuring of the new H1EDCU_ASCIMC.ini file which has the duplicate GAIN channels removed.

Investigation of DC offset to chan adc_1_7 on h1ascimc is proceding.

H1 SUS
jeffrey.kissel@LIGO.ORG - posted 06:58, Tuesday 05 February 2013 (5372)
H1SUSMC2.txt Foton File Copied to the Userapps Repo
In order to help investigate / model the recent problems with IMC closed loop TF changes (see LHO aLOGs 5279, 5294, and 5367), I've copied over the foton file for H1SUSMC2 into the userapps repo and committed,
/opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSMC2.txt

Note, though it's been verbally agreed upon during a few CDS software calls, most of these filter files are *not* hard links to the userapps repo. We should really get this decision in a CDS requirements document, and make sure all sub-systems obey -- because now we're in an awkward state where the chans folder is full of original files, soft links, hard links, and it's not clear at any point if the repository or the chans folders is the right place to go for currently-in-use filter files.
LHO General
justin.bergman@LIGO.ORG - posted 06:58, Tuesday 05 February 2013 (5362)
Monday Ops Summary
LVEA laser safe all day
Doug C and Jason working on alignment in LVEA
Apollo crew working at EY most of the morning.

0800 - PSL diode chiller water refilled by Michael and Justin
0845 - Carolyn P working at both MX and MY
0915-1115 - Michael R working on FSS in HI PSL
0945 - Hugh working on HAM3 L4C leveling; will coordinate with IMC folks (not currently locked)
1100 - Dale escorting tour group of middle school educators around site, including control room and LVEA. 
1245 - Betsy to LVEA working on BS, Dale photographing
1400 - Vincent taking measurements on BSC6.
H1 IOO
kiwamu.izumi@LIGO.ORG - posted 21:20, Monday 04 February 2013 (5371)
offset at ASC_ADC_1_7 seems from the AA board

During the QPD connection check, I found that the segment #4 of the MC2_TRANS showed a big offset of approximately 4300 counts. According to the 10 min trend, this offset has been there from the beginning (Jan. 16th [1]). I disconnected the signal chain at various points to find out which electronics is causing the offset. It seems that the AA board [1][2] is the one. I disconnected the SCSI (which connects the AA board and ADC) to see if it removes the offset and indeed the offset went to zero with the SCSI off. I will have a close look at the AA board tomorrow and hence may need to pull the chassis out of the rack if necessary. Note that because of this investigation the IMC was intentionaly unlocked from approximately 8PM to 9PM.

[1] LHO alog 5127
[2] D0902783
[3] S1102790

H1 SUS
betsy.weaver@LIGO.ORG - posted 19:40, Monday 04 February 2013 (5369)
SUS BS re-alignment and more re-alignment

Travis, Betsy, Jason, Doug

After the jinxing at the morning meeting regarding how easy the Beamsplitter alignment was going, we proceeded to walk the pitch and yaw DOFs all over the place for most of the day.  LIGO Lesson #239: Never assume that things are going well.  Lesson #240: Never announce that things are going well in a meeting.

Yesterday, we had the pitch and yaw alignment close albiet at the ends of adjustment ranges in both DOFs.  We had a bit of a differential pitch between the top mass and the optic which meant we were unable to center the BOSEMs once pitch and yaw had been aligned.  So, after chasing tails a bit, we bit (!) the bullet and used the pushers to adjust the yaw, while keeping the BOSEMs all in range.

We left with yaw and pitch back to being close, but need to finish OSEM alignment in the morning.  Then, on to a quick TF set, followed by baffle alignment, as was the plan today.

LHO General
patrick.thomas@LIGO.ORG - posted 19:16, Monday 04 February 2013 (5368)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot requested from 5 PM Feb. 3 to 5 PM Feb 4. Also attached are plots of the modes to show when they were running/acquiring data. Michael R. swapped out the dust monitor in the H1 PSL enclosure (location 10 in the LVEA), but the one I gave him to replace it with has stopped counting.

Data taken from h1nds1.
660 seconds worth of data was unavailable on this server
1440.0 minutes of trend displayed

Dataviewer gave a 'No data output.' message retrieving the data for the counts > .5 microns.
Non-image files attached to this report
H1 IOO
keita.kawabe@LIGO.ORG - posted 18:30, Monday 04 February 2013 - last comment - 08:36, Wednesday 06 February 2013(5367)
MC OLTF peak is not a peak in the FSS

Somehow the hypothesis has been that the peak in the MC OLTF is the structure in FSS and we should be able to mitigate that guy if we retune the FSS notch.

That was attempted today, but the problem is that the peaks the FSS notch is notching out are at about 780 kHz, and MC "peak" we're talking about is a rather broad thing at around 710 kHz. We could move the FSS notch to there, but if we do that the FSS structures are almost totally out of the notch. See attached. Note that the MC OLTF was measured without Evans Notch (TM).

It's clear that the "peak" we're talking about is not the FSS peak per se, it's either a simple gain peaking or something that is not there in FSS. Keeping Evans Notch (TM) sounds fine to me, but if somebody feels the need to put move it out on the option board in the common mode board, please feel free.

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 08:36, Wednesday 06 February 2013 (5388)

Correction: Both the OLTF of MC without (middle) and with (bottom) the notch in the MC path are in the plot.

H1 SEI
hugh.radkins@LIGO.ORG - posted 16:51, Monday 04 February 2013 (5366)
WHAM3 HEPI L4C Leveling 3/4 Complete--HEPI ***FLOATING***
Still need to do the NE Corner to close out.  HAM3 HEPI is currently FLOATING.
H1 PSL
michael.rodruck@LIGO.ORG - posted 16:47, Monday 04 February 2013 (5365)
TTFSS/RF work

Michael, Keita, Dick G

We received the 4 port RF combiner today and were able to install it in the H1 electronics room. I measured 17.3 dBm going into the TTFSS LO inside the laser room with no attenuation. The common gain was lowered from 18 to 15 dB to give a UGF at 415 kHz with 55 degrees of phase margin.

We then tried to adjust the notch at 790 kHz but in the process I appeared to have crushed the variable capacitor and had to replace it. While tuning the notch back to 790 kHz with the new capacitor we noticed a peak around 1.6 MHz with a notch just off it at 1.8 MHz. We brought the notch to 1.6 MHz to compensate for this peak using a variable capacitor labeled in the attached picture.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 12:55, Monday 04 February 2013 (5361)
front end model and mx stream restarts

The INI change for the h1isietmy system precipitated a mini-restartfest. We restarted the models on h1seib2, h1susb6 an h1pemey (Dolphin related) and then restarted mx streams on h1susbstst, h1susauxb6 and h1susauxh2 (mx end point related).

H1 SEI
hugh.radkins@LIGO.ORG - posted 12:48, Monday 04 February 2013 (5360)
WHAM3 HEPI is now Unlocked---L4Cs being Leveled
Mind the signs--the HEPI is unlocked so the Blue Crossbeams are floating.  Do not step on anything if possible.  I should wrap this up today after which I will relock.
H1 SEI
greg.grabeel@LIGO.ORG - posted 11:31, Monday 04 February 2013 (5354)
HAM6 HEPI Install
The housings, crossbeams, and clamps have been installed on HAM6. It was a bit of a tight squeeze but with the help of Apollo we managed to get it done. Support tube positioning is almost complete, at which point I'll lock down the springs. One housing clamp needed a small modification, but is working well now.
Images attached to this report
H1 IOO
kiwamu.izumi@LIGO.ORG - posted 11:00, Monday 04 February 2013 (5359)
MC master screen updated

I have updated the IMC master screen, namely H1IOO-MC.adl, to the laest Livingston one this morning in order to enable links for some QPDs associated with the IMC.

H1 CDS
vincent.lhuillier@LIGO.ORG - posted 10:07, Monday 04 February 2013 (5358)
IPC error tripped watchdogs - H1SEIB6

The IOP watchdog of H1SEIB6 was tripped due to a IPC connection error between H1SEB6 and H1SUSB6 (cf attachment). An error rate of 10samples/s (64K model) will be allowed soon.

Images attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:28, Friday 01 February 2013 (5357)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot requested from 5 PM Jan. 30 to 5 PM Jan 31. Also attached are plots of the modes to show when they were running/acquiring data. Dust monitor 10 in the H1 PSL enclosure is still indicating a calibration failure.

Data taken from h1nds0.
T0=13-01-31-01-00-00; Length=86400 (s)
9780 seconds worth of data was unavailable on this server
1419.0 minutes of trend displayed
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:09, Friday 01 February 2013 (5356)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot requested from 5 PM Jan. 31 to 5 PM Feb. 1. Also attached are plots of the modes to show when they were running/acquiring data. Dust monitor 10 in the H1 PSL enclosure is still indicating a calibration failure.

Data taken from h1nds0.
T0=13-02-01-01-00-00; Length=86400 (s)
7740 seconds worth of data was unavailable on this server
1427.0 minutes of trend displayed
Non-image files attached to this report