TITLE: 07/04 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY:
The SQZ-FIBR_TRANS_DC is just barely over the high power limit (Tagging SQZ)
I unmonitored the CSSQZ channel H1:SQZ-FIBR_LOCK_TEMPERATURECONTROLS_ON as it would periodically turn off and on at a high frequency without seemingly doing anything to the BEAT_FREQ, so this won't keep dropping us out of observing tonight
Ryan C, Sheila D
Summary: The input beam moved after the PSL incursion, alinging the IMC doesn't completely restore the input beam alignment to the IFO. Using IM4 QPD as a reference to move IM3 resulted in no beam on the ISS second loop, so we have reverted that for now.
Before Tuesday's PSL incursion, when the IMC was locked at 2W IM4 trans QPD was fairly well centered, we had 1.5 or 1.6 counts on the ISS second loop inner and outer loop sums, 310 counts on MC2 trans QPD, and 95 counts on the ISS second loop QPD. After Jenne relocked the IMC yesterday, we had 2W on IM4 trans, but the QPD was off center with ~0.3 pit and 1 in yaw, the second loop inner and outer sums were 1.46 and 1.6, 305 counts on MC2 trans, and 94 on ISS second loop QPD.
This morning Camilla and company moved IM3 to re-center the beam on IM4 trans, 78831, After our struggles with input alignment after the vent earlier this year, we learned that LLO uses IM4 QPD as a reference to adjust IM3 trans when needed, so we had centered IM4 hoping to use it as a reference in this way. However, doing this made the beam completely fall off the ISS second loop, with no power on it's QPD or the two PD sum channels. This may mean that we were close to clipping in the second loop before, so we should come back to this another day to think about how we can restore the input alignment to what it previously was, and make sure we don't clip on the ISS.
For now I reverted IM3 sliders to this morning, and Ryan is working his way through the initial alignment.
Along the way he also showed me that the X arm green transmission is extremely noisy, with high frequency fuzz. This might mean that we still have some electronics problems at EX after today's work. Sicne Ryan has been able to get past ALS locking tonight, we won't try to address this issue tonight.
Also, a note, that Ryan had trouble with SRY, but lowering the threshold for triggering allowed it to lock fine and run WFS. We might consider using lower thresholds here.
Currently relocking at TRANSITION_FROM_ETMX
Following a lockloss at LASER_NOISE_SUPPRESION, XARM started having PDH issues and looked extremly fuzzy. ALS_X PDH kept locking and unlocking. After a bit of letting guardian try and adjusting ETMX, TMSX and getting no gains (the DIFF beatnote was -14) I dropped to do a MANUAL_IA thinking that the input align might still be off. I ended up adjusting IM3 and IM4 again which reduced the fuzz and reduced the PDH unlockings frequency, touching PR2 further stabilized it. After lots of trying to walk the IMs, PR2, and PR3 (reverted after no gains) and XARMs signals still not being able to converge I skipped ahead to INPUT_ALIGN and ran into the same issue from earlier today at ACQUIRE_XARM_IR and I had to move IM4 more to more center it on POPA which got the automation to kick in and do the rest. I finished the IA to be safe and then I was able to lock ALS (XARM is still fuzzy but not nearly as much and the PDH didn't unlock) and move on finally.
I wonder if the DARK offsets need to be updated based off alog76982 which describes similar behavior to what I saw during this IA, light on LSC-TR_X when there shouldn't be during ACQUIRE_XARM_IR.
Lost lock LASER_NOISE_SUPPRESIOIN again right after the ISS 2nd loop turns on. XARM looks bad after each lockloss as well.
Jennie, Sheila, Keita, Oli, Daniel, Camilla
After observed temperature dependence 78703, and ALS X beatnote intermittency dropping 78806, 78745 and this mornings PSL fiber realignment 78839, the beatnote was -30dB.
Jenne, then Sheila, then myself went onto ISCTEX (photo) and measured:
We started with a -60dB peak on the spectrum analyzer, using the amplifier's "-1dB Mon" channel. We plugged the spectrum analyzer straight into the BBPD and saw a very similar signal.
We then plugged into the amplifier's "+13dB " channel that's being used as the output. Beatnote ws clearer and around -40dB, photo.
Jenne and Sheila improved this by touching ALS-M1 and ALS-M2 (layout D1800270) we needed ot walk these two mirrors to make improvements. We also adjusted ALS-M3 as the DC power started to reduce on the BBPD. Once we got to -20dB on the spectrum anaylizer (in progress photo here), we plugged back in the main cable and using the ndscope beatnote, got back to -17dB. Although we are not happy, this was much better than the -30dB we started with and the PLL can lock. Leaving here for the day. Expect that if we had plugged back into the MON channel or straight into the BBPD we'd have seen -40 to -35dB, but we didn't...
We had a spare BBPD (EE shop ISC cabinet) but didn't try it. Daniel's view is that the coming and going bad signals is a sign or an amplifier or other electronics failing.
Reduced beatnote minimum to -40 so we shouldn't have overnight issues.
There is a power adjustment stage after the beam that measured 62mW of laser power. The nominal power on the broadband PD should be around 2mW. This is what the FIBER_A_DC_POWER is indicating as well. If 0.5mW exits the fiber, about 0.2 to 0.25mW should make it to the broadband PD. This would result in a 10-12% jump, when the fiber is blocked.
The expected beat note is sqrt(2mW * 0.2mW)=0.6mW, if the mode overlap is maximum. With a ~2K transimpedance gain and a 0.09A/W efficiency, we should see a beat note strength of -6dBm minus the overlap mismatch. The RF preamplifier nominally adds +13dB of gain. However the expected +7dBm would be about 2dB above the 1dB compression point of the RF amplifier.
I have put labels in front of the MC2, PRM and PR2 camera blue-boxes to show that these cameras have been temporarily removed as part of viewport work.
LouisD, SheilaD, FranciscoL
On Thursday, June 13 2024, we made simuline measurements after changing DHARD pitch and yaw gains. We see a change in the sensing function from a 50% increase of the DHARD pitch and yaw gains.
Routine calibration measurements done at 2024-06-13 15:46 UTC (78409). We increased (in magnitude) H1:ASC-DHARD_Y_GAIN from -40 to -60, and H1:ASC-RPC_DHARD_Y_GAIN from -30 to -45 -- a 50% increase -- and ran a second calibration measurement at 2024-06-13 16:56 UTC. The trend dhard_gain.png shows the values from these channels within the calibration measurements time window. The DHARD gains were reverted around 2024-06-13 17:40 UTC.
Plotting the transfer function of both measurements on out.png shows a significant change in the sensing function in the low frequency (<10 Hz). The uncertainty is below 2% for most of both measurements as seen in unc.png. These plots were produced using compare_measurements.py
(full path: /ligo/home/francisco.llamas/CAL/sensing_function/20240621_plot_sensing_measurements/compare_measurements.py).
We had to run git config --global safe.directory='*'
where the '*'
should be the changed by the name of the report that the script was unable to find.
Follow up analysis and plots to come.
J. Oberling, R. Short, J. Driggers
Summary available at this alog.
Background
Our PMC Reflected Power (PMC Refl) has been slowly increasing for several months, roughly starting in mid-March. There was an unexplained PMC Refl increase near the beginning of the year, but things were mostly calm until the middle of February; we were able to correct this with a remote alignment tweak on Feb 27, 2024, but this is the final time an alignment tweak made any real improvement. We had been able to recover PMC Refl to just under 17.0 W by slightly tweaking the operating currents of the amplifier pump diodes back in April (changing beam quality but maintaining output power), but this did not stop the slow increase in PMC Refl. At the end of May Ryan S. and I went into the enclosure and made some measurements around the PMC. We found the visibility measured at ~91%, while our PMC throughput was down around ~83%; we also inspected the optics between Amp2 and the PMC and found no issues except some residue on mirror M11. We drag wiped this mirror until it was clean but this caused no change in PMC behavior. This indicates a potential issue with the PMC itself, and is very similar to the symptoms LLO saw with the original, glued PMCs back in the O1/O2 era. Oddly enough, after our incursion PMC Refl jumped by ~1.3W, from ~19.7W to ~21.0W, and we could again find no explanation for this jump. Since we could find no other cause for the slow increase in PMC Refl (not alignment, not mode matching, not dirty optics, etc.) we decided at the time to watch how things developed, with the understanding we would likely have to swap in the spare soon (mystery loss was already at almost 8%). The PMC Refl increase flattened out for a couple weeks but started increasing again in the latter half of June, and at a quicker rate than previous, so we decided it was time to swap in the spare; Tuesday morning, right before we started the spare swap, we found PMC Refl had already increased past 23 W (Ryan took that last set of trends during his EVE shift on 7/1).
The Swap
We began by taking a transfer function of PMC SN007 (the old PMC), shown in the first picture. The UGF is a little high (the new PMCs like to be at ~1kHz), but I recall this being the best we could do at the time (we don't have enough electronic gain control to get the UGF to 1kHz by itself, we have to lower the light level on the locking PD to lower the optical gain; this has to be balanced with the dark voltage on the PD, making sure the locked voltage is above the dark voltage). All in all the TF looks normal. We then shut off ISS and FSS, unlocked the PMC, turned off the PMC temperature control loop, and turned off the PMC PZT high-voltage power supply. Time to go into the enclosure.
Once inside we used the High Power Attenuator assembly to lower the power incident on the PMC to 100mW, the typical power level used for alignment; this was done as a "just in case" for laser safety reasons. We then unwrapped and inspected the new PMC; it is SN004. Everything, for the most part, looked really good. We did find a small bit of something on the main output mirror (2nd picture), but were able to successfully drag wipe it away without leaving and residue that we could see (3rd picture). We did have to move the insulated cover for the PMC's terminal block from SN007 to SN004 (to keep someone from accidentally touching the PZT high-voltage connector), and had to slightly re-route the PZT wires so they were not on the spot where the damping clamps sit. That done we were ready to swap the PMCs. The new PMC fit nicely into the magnetic base and everything looked nice and even. We installed the damping clamps with the bolts only finger tight to start, plugged in the 2 wires (voltage supply for the heater and PZT), turned on the PZT high-voltage power supply, and proceeded with recovering the PMC. Pictures 4 through 6 show, in order, the old PMC SN, the new PMC SN, and the new PMC freshly installed on the PSL table.
The Recovery
To get enough light on the PMC locking PD to actually lock the PMC we have to raise the incident power to 10 W (and this is pushing it), so we did so. On our first attempt to lock the PMC it would not lock, but we did see a small bit of TEM00 flashing through on the PSL Quad display as the PZT ramped. We routed our spare Lemo cable bundle into the PSL enclosure so we could access the ramp signal, and fired up an oscilliscope to look at the signal on the locking PD. Once we had it triggering on the PZT ramp we could see several smaller peaks flash through, but one slightly larger one that could be our TEM00. I did an extremely small yaw adjustment on mirror M12 (my guess is less than 1/32 of a turn, as it barely moved under my fingers) and the suspected TEM00 peak immediately grew by a large amount. We figured, why not, and tried to lock the PMC; it locked right up without issue, transmitting ~3.5 W out of the 10 W incident. Success! Or so we thought.
We fired up the picomotors on mirrors M11 and M12, and Ryan proceeded with tweaking alignment into the PMC. However, the best he could get was 7.5 W out of the incident 10 W. We measured the visibility at ~95%, while our power throughput was only 75%. Well then.
We began checking everything we could think of: optic cleanliness, beam alignment, took a look at the control loop, PD alignment. Ultimately, we found the beam was misaligned on the locking PD. Once this was fixed Ryan was able to get PMC Trans up to 8.4 W, but that was it. So while better, we still had a throughput of only 84%, and still could find no explanation for the discrepancy between visibility and power throughput. At this point we called Jenne for a consult, get the whole PSL team together. She suggested we check to make sure our locked PD voltage was above our dark voltage, and sure enough it wasn't. I increased the light on the PD until the locked voltage was about double the dark voltage, but this didn't improve the ~10% discrepancy between visibility and power throughput. At this point we figured we had 3 options:
Ultimately, we decided on option 3. Assuming we were able to get to full power (spoiler alert, we were able), this would then give us a valuable piece of information: Does the new PMC exhibit the same behavior as the old PMC (the slow increase in PMC Refl)? If it does, then the problem likely isn't with the PMC (although I still struggle to explain the discrepancy between visibility and power throughput in this scenario). At this point we had already overrun the maintenance window by an hour, so we began increasing the power incident on the PMC in steps, checking mirrors for bright spots along the way; we did this slowly out of an abundance of caution, as we did not want to damage this PMC (we don't have a spare for our spare). At each step we measured the visibility (this time properly accounting for the 15 mV of dark voltage on this PD) and power throughput; we only tweaked alignment at the first 10W step and at the final full power step. Power In and Power Out were both measured with our roving water-cooled power meter; the locking PD unlocked voltage was adjusted to approximately -1 V at each power up (the locking PD outputs a negative voltage). The steps:
Power In (W) | Power Out, Initial (W) | Power Out, Final (W) | Visibility (%) | Power Throughput (%) |
10.0 | 3.5 | 8.4 | 94.8 | 84 |
20.0 | 17.3 | 17.3 | 96.0 | 86.5 |
30.0 | 26.2 | 26.2 | 95.0 | 87.3 |
40.1 | 34.7 | 34.7 | 96.1 | 86.5 |
60.1 | 52.2 | 52.2 | 96.1 | 86.9 |
80.2 | 68.7 | 68.7 | 94.9 | 85.7 |
100.0 | 84.9 | 84.9 | 93.7 | 84.9 |
128.1 | 104.4 | 105.1 | 89.6 | 82.0 |
At 20 W incident power I noticed a bright spot forming on the PMC input mirror. I kept an eye on it as we powered up, but at 80 W it started to make me uncomfortable so I did a quick drag wipe of that mirror to see if the spot went away. It did not and the PMC behavior was completely unchanged. Ah well.
To end the PMC recovery we took a TF of the new PMC, as shown in the 7th and final picture. Intially we had a UGF of ~2.5 kHz, but this was with our locking PD unlocked voltage still set at 1V; at this setting we had ~ -110 mV on the PD while the PMC was locked, so plenty of room to lower the optical gain. In the end we had a locked voltage of -0.061 V and an unlocked voltage of -0.453 V; this is a visibility of 86.5%, so we definitely have some more optimization to do here (PMC transmission was unchanged after lowering the light on the locking PD). I did not notice this yesterday, but the TF of the new PMC starts getting noisy around 500 Hz, while the old one was pretty smooth all the way to 100 Hz; I also did not notice the difference in y-axis scales until just now as I was uploading these pictures. More indication that we have further optimization work to do here. Finally, we measured PMC Trans and PMC Refl with our roving water-cooled power meter and recalibrated the PD readings in the PMC MEDM; these measured at 105.1 W and 23.0 W respectively. At this point the new PMC was up and running, so we started recovering the other PSL subsystems (chiefly the FSS RefCav).
We started by trying to lock the RefCav, and it would not lock. Dreading the results, I looked at the alignment into the RefCav on our handy alignment iris and yup. Alignment was off. We informed Jenne that RefCav alignment was off, indicating the PMC output was at a slightly different alignment than the old one. This means beam alignment into the IMC (and out of the IMC, as it turns out) and onto ISCT1 was also going to be off, especially as these are both 10s of meters from the PMC (the RefCav is only a few meters from the PMC). Our best guess as to the cause is the mirrors of the new PMC being at slightly different angles compared to the old; this also explains the small yaw shift I had to do to initially lock the new PMC. So Jenne and Sheila worked on recovering the IMC and ISCT1, respectively, while Ryan and I started realigning the RefCav. At this point we were almost 3 hours past maintenance end, so we settled on getting the FSS working under a best effort basis with the understanding we would have to go back in during the next maintenance window to completely tune it up (we have more PMC optimization to do so we already have to go back in on July 9th anyway). In the end we had a single-pass diffraction efficiency for the FSS AOM of 71.7%, a double-pass diffraction efficiency of 69.0%, and a RefCav TPD of just over 0.7 V; we have 263.0 mW input to the FSS AOM and 130.3 mW incident on the RefCav. Not great, but it's working. We forgot, however, to tweak the alignment into the ALS/SQZ fiber pickoff; Sheila was able to temporarily bypass that by lowering locking thresholds for both ALS and SQZ subsystems, and Jenne and I went into the enclosure this morning and tweaked that alignment.
This concludes yesterday's PMC swap saga. I'm keeping WP 11947 open as we still have optimization to do on the new PMC; we also still have to completely tune the FSS path. During this week we will keep an eye on PMC Refl to see if this new PMC exhibits the same behavior as the old one.
TITLE: 07/03 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY:
The IFO has been unlocked all day due to a HAM2 DAC failure and for PSL and ALS adjustments left over from yesterday's maintenence.
The Beat note at End X was touched up by Jenne Camilla and Sheila. This started in the morning and ended shortly before 4.
We started an Initial Alignment, but got stuck in Find X arm IR.
LOG:
Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
---|---|---|---|---|---|---|
16:08 | SAF | LVEA | LVEA | YES | LVEA IS LASER HAZARD | 10:08 |
15:10 | FAC | Karen | Optics Lab | N | Technical cleaning | 15:46 |
15:33 | PSL | Jason & Jennie | PSL Enclosure | YES | Touching up alignment of ALS FC2 | 17:16 |
17:19 | PEM | Robert Carlos Milly | Along arm Y | No | Testing a Seismometer in the dirt | 20:19 |
17:21 | ISC | Richard | LVEA HAM6 | Yes | Checking out some racks near HAM6 | 17:31 |
17:24 | ASL | Jenne, Sheila, Camilla, Ollie | X Arm | Yes | Transitioning to LASER HAZARD to adjust ALS | 21:01 |
18:07 | PCAL | Karen & Francisco | PCAL Lab | Yes | Technical cleaning & escort. | 18:22 |
21:03 | ALS | Camilla | LVEA | Yes | Getting power meter | 21:22 |
21:14 | VAC | Gerardo | FTCE | N | Getting parts and checking Vacuum | 21:41 |
21:23 | ASL | Camilla, Jenne, Sheila | EX | Yes | Realigning ALS X fiber | 23:30 |
21:29 | CDS | Jonathan fil | CER | N | Unplugging cat 5 cables to restart cameras | 22:32 |
23:10 | PEM | Robert | LVEA | Yes | Setting up shaker | 23:30 |
TITLE: 07/03 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 12mph Gusts, 10mph 5min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.08 μm/s
QUICK SUMMARY:
I had a lockloss at LASER_NOISE_SUPPRESION but now XARMs PDH keeps locking and unlocking and looks very fuzzy and the DIFF beatnotes bad, -14
TITLE: 07/03 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
CURRENT ENVIRONMENT:
SEI_ENV state: SEISMON_ALERT
Wind: 6mph Gusts, 4mph 5min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.08 μm/s
QUICK SUMMARY:
After Erik replaced the HAM2 DAQ.
There was a timing error on another chassis h1sus2b, which required a restart. see Eriks alog.
I then put all the Optics in safe mode to restart that chassis & reset the ISI and HPI watchdogs.
There was a DAC Kill i also had to reset to reset the ISI and HPI watchdogs.
We are now trying to get an initial alignment in. But the IMC is not locking. This may be due to the fact that the IMC is in the HAM that tripped this morning.
Taking ISC_LOCK to IDLE
Trending the Sliders back before the earthquake for the IMC.
Camilla and I touched up MC1, MC3, PRM, IM2, IM4 back to the slider values before the tripped chassis and recovery and IM3 see Camilla's Alog.
Jason and Jenne went into the PSL room to adjust the ASL_FC2. When they came out Jenne said that an ASL adjustment at End X was next.
Jenne Sheila Camilla & Ollie are at EX working on ALS fiber alignment.
[Vlad, Louis] We were taking a look at the GDS FIR Filter plots (pg. 21+) in the calibration reports at LHO (H1_calibration_report_20240601T183705Z.pdf) and LLO (L1_calibration_report_20240518T183037Z.pdf) side by side. We noticed several features in the GDS FIR filter comparison plots that we don't understand. 1. res_corr_comparison.png: the LHO res corr comparison (I think this stands for "residual correction comparison") starts to run away at low frequencies (<8 Hz), while it's flat at LLO. 2. ratio_res_corr_comparison.png: LHO's "Ratio of Res Corr comparison" plot has a low frequency ripple that is not present in LLO's reports. 3. ratio_res_corr_no_cc_pole_comparison.png: same as above for the "Ratio of Res Corr No CC Pole Comparison" plots 4. ratio_tst_corrections_comparison.png: There are resonances present in LHO's "Ratio of TST corrections comparison" plots that 1.) don't appear in LLO's reports and 2.) don't match up with the violin modes at 500 Hz and 1kHz. The same is true for the PUM (ratio_pum_corrections_comparison.png) and UIM (ratio_uim_corrections_comparison.png) stages. The biggest concern is whether these discrepancies are outside of nominal for the GDS FIR pipeline, which would mean that we are introducing additional errors in the GDS pipeline. Could it be an issue in our model of DARM somewhere along the way? Or a mismatch between CAL-CS and the model?
Sheila, Tony, Jenne, Camilla. Details in 78828.
Ryan, Jenne, Camilla
We tried aligning ASC-POP_A with IM4 adn then ASC-X_TR_A with PR2 but couldn't get the X arm locked.
We then reverted IM3, IM4 and PR2 so that the x-arm could lock.
Ryan slowly moved IM3 back to this position and the servos followed along!
Calibration sweep taken today at 2106UTC in coordination with LLO and Virgo. This was delayed today since we were'nt thermalized at 1130PT.
Simulines start:
PDT: 2024-06-29 14:11:45.566107 PDT
UTC: 2024-06-29 21:11:45.566107 UTC
GPS: 1403730723.566107
End:
PDT: 2024-06-29 14:33:08.154689 PDT
UTC: 2024-06-29 21:33:08.154689 UTC
GPS: 1403732006.154689
I ran into the error below when I first started the simulines script, but it seemed to move on. I'm not sure if this frequently pops up and this is the first time I caught it.
Traceback (most recent call last):
File "/var/opt/conda/base/envs/cds/lib/python3.10/multiprocessing/process.py", line 314, in _
bootstrap
self.run()
File "/var/opt/conda/base/envs/cds/lib/python3.10/multiprocessing/process.py", line 108, in r
un
self._target(*self._args, **self._kwargs)
File "/ligo/groups/cal/src/simulines/simulines/simuLines.py", line 427, in generateSignalInje
ction
SignalInjection(tempObj, [frequency, Amp])
File "/ligo/groups/cal/src/simulines/simulines/simuLines.py", line 484, in SignalInjection
drive.start(ramptime=rampUp) #this is blocking, and starts on a GPS second.
File "/var/opt/conda/base/envs/cds/lib/python3.10/site-packages/awg.py", line 122, in start
self._get_slot()
File "/var/opt/conda/base/envs/cds/lib/python3.10/site-packages/awg.py", line 106, in _get_sl
ot
raise AWGError("can't set channel for " + self.chan)
awg.AWGError: can't set channel for H1:SUS-ETMX_L1_CAL_EXC
One item to note is that h1susex is running a different version of awgtpman since last Tuesday.
This almost certainly failed to start the excitation.
I tested a 0-amplitude excitation on the same channel using awggui with no issue.
There may be something wrong the environment the script is running in.
We haven't made any changes to the environment that is used to run simulines. The only thing that seems to have changed is that a different version of awgtpman is running now on h1susex as Dave pointed out. Having said that, this failure has been seen before but rarely reappears when re-running simulines. So maybe this is not that big of an issue...unless it happens again.
turns out i was wrong about the environment not changing. according to step 7 of the ops calib measurement instructions, simulines has been getting run in the base cds environment...which the calibration group does not control. That's probably worth changing. In the meantime, I'm unsure if that's the cause of last week's issues.
The CDS environment was stable between June 22 (last good run) and Jun 29.
There may have been another failure on June 27, which would make two failures and no successes since the upgrade.
The attached graph for June 27 shows an excitation at EY, but no associated excitation at EX during the same period. Compare with the graph from June 22.
On Jun 27 and Jun 28, H1:SUS-ETMX_L2_CAL_EXCMON was excited during the test.