Displaying reports 8141-8160 of 84686.Go to page Start 404 405 406 407 408 409 410 411 412 End
Reports until 11:04, Wednesday 03 July 2024
H1 CDS
david.barker@LIGO.ORG - posted 11:04, Wednesday 03 July 2024 (78836)
Reminder of expected EX Timing System error

A reminder that the current EX Timing System error is expected due to a mismatch in the timing card firmware version for h1susex's timing card. To verify that this is the only timing error at EX, I have added a check in the CDS STAT system. It will report an error is an additional timing error occurs.

I have annoted the timing system top level MEDM with this information, and included a related display button to open the CDS STAT MEDM (see attached).

When the timing system is updated to expect the new firmware version and remove the EX error, I will remove these temporary measures.

Images attached to this report
LHO FMCS
tyler.guidry@LIGO.ORG - posted 09:59, Wednesday 03 July 2024 (78833)
LEXC Exhaust Fans
The exhaust fans that serve the LEXC bathrooms were not commanding on. We searched for any sign of power local to the fan and none could be found. All circuits that serve the fan were not tripped. At this time we have manually forced them on at the FMCS. We suspect the failed AHU in LEXC zone 2 sets the occupancy schedule for these fans. The fans will continue to be operated manually until PHP-02 (dead Daiken) is repaired.

B. Gateley E. Otterman T. Guidry 
LHO General
tyler.guidry@LIGO.ORG - posted 09:54, Wednesday 03 July 2024 (78832)
Site Glycol Makeup
MX, EX, MY all received approximately 130 gallons of glycol between the 3. Line pressures were set to their desired levels.

T. Guidry E. Otterman C. Soike
H1 ISC
camilla.compton@LIGO.ORG - posted 09:24, Wednesday 03 July 2024 - last comment - 17:25, Wednesday 03 July 2024(78831)
IM3 adjusted 450urad in Yaw to center beam on IM4 trans.

Sheila, Tony, Jenne, Camilla. Details in 78828.

Comments related to this report
camilla.compton@LIGO.ORG - 17:25, Wednesday 03 July 2024 (78847)

Ryan, Jenne, Camilla

We tried aligning ASC-POP_A with IM4 adn then ASC-X_TR_A with PR2 but couldn't get the X arm locked.

We then reverted IM3, IM4 and PR2 so that the x-arm could lock.

Ryan slowly moved IM3 back to this position and the servos followed along! 

H1 CDS (SUS)
erik.vonreis@LIGO.ORG - posted 08:44, Wednesday 03 July 2024 - last comment - 11:16, Wednesday 03 July 2024(78827)
h1sush2b had timing glitch caused by h1sush2a DAC replacement

At 14:44 UTC h1sush2b suffered a timing error and had to be restarted. 

The timing error happened when work was being done in the same rack in the CER, see https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=78823.

The timing error was a "long cycle" of 50 milliseconds.

 

 

Comments related to this report
david.barker@LIGO.ORG - 11:16, Wednesday 03 July 2024 (78838)

Restart log for this morning's work:

Wed03Jul2024
LOC TIME HOSTNAME     MODEL/REBOOT
05:30:57 h1sush2a     ***REBOOT*** 
05:33:09 h1sush2a     h1iopsush2a 
06:45:01 h1sush2a     ***REBOOT***
06:47:12 h1sush2a     h1iopsush2a
07:18:01 h1sush2a     ***REBOOT***
07:20:13 h1sush2a     h1iopsush2a
07:35:51 h1sush2a     ***REBOOT***
07:38:04 h1sush2a     h1iopsush2a
07:38:17 h1sush2a     h1susmc1  
07:38:30 h1sush2a     h1susmc3 
07:38:43 h1sush2a     h1susprm 
07:38:56 h1sush2a     h1suspr3
07:59:25 h1sush2b     ***REBOOT***
08:01:07 h1sush2b     h1iopsush2b
08:01:20 h1sush2b     h1susim   
08:01:33 h1sush2b     h1sushtts
 

H1 AOS
bubba.gateley@LIGO.ORG - posted 08:30, Wednesday 03 July 2024 (78826)
Well Pump Running
Started well pump to top off fire water tank. Pump will run for 4 hrs and auto off.
H1 General
anthony.sanchez@LIGO.ORG - posted 07:48, Wednesday 03 July 2024 (78824)
Wednesday Ops Shift Start

TITLE: 07/03 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 16mph Gusts, 12mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.08 μm/s
QUICK SUMMARY:
DIAG_MAIN says : CONNECTION ERRORS, See SPM DIFFS for dead channels.
CDS_OVERVIEW shows:
H1OPSUSHA is clearly having a hardtime as described in Oli's alog: 78823 . Erik is saying that this is a bad 18 bit DAC.C

Images attached to this report
H1 CDS (OpsInfo, SUS)
oli.patane@LIGO.ORG - posted 05:56, Wednesday 03 July 2024 - last comment - 10:06, Wednesday 03 July 2024(78823)
H1IOPSUSH2A error

Erik, Oli

Got a call from IFO_NOTIFY - there was ground motion that caused the HAM2 ISI (11:56:26 UTC), SEI SW (11:56:28 UTC), and Hepi (11:56:31 UTC) watchdogs to trip. Along with/causing this (or by coincidence?) is an error with H1IOPSUSH2A, and the GDS screen was showing 'LTDS' in red. The front end needs to be either power-cycled, or possibly a card replaced, so Erik will be heading into site in a bit to see about fixing the errors. I manualed ISC_LOCK into IDLE, and either me or the DAY operator will get the ifo back up once the CDS issue is resolved.

Images attached to this report
Comments related to this report
erik.vonreis@LIGO.ORG - 07:46, Wednesday 03 July 2024 (78825)

[Erik, Richard]

The third 18-bit DAC (DAC 2) on h1sush2a failed.  It no longer appeared on the PCI Bus.

Richard replaced the DAC and we restarted the front end.

I originally misdiagnosed the problem as a bad timing card, since the DAC failure caused cascading timing errors on other cards, so we also replaced the timing card with serial number S2101122

erik.vonreis@LIGO.ORG - 09:11, Wednesday 03 July 2024 (78830)

Serial number of the failed DAC is:

101208-06

jim.warner@LIGO.ORG - 10:06, Wednesday 03 July 2024 (78834)

The ground motion plotted here is very unlikely to have caused a seismic watchdog trip. The ham2 trip was almost certainly caused by the sush2a failure.

H1 General (CDS, PSL)
ryan.crouch@LIGO.ORG - posted 01:01, Wednesday 03 July 2024 (78817)
OPS Tuesday EVE shift summary

TITLE: 07/03 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Oli
SHIFT SUMMARY: Spent most of the shift down from the high winds. Currently relocking at DHARD_WFS

Lock 1: Alignments and PRC1 bypass
Lock2: Windy, 42mph Gusts, 33mph 5min avg
General:

LOG:                                                                                                                                  

Start Time System Name Location Lazer_Haz Task Time End
16:08 SAF LVEA LVEA YES LVEA IS LASER HAZARD 10:08
00:58 pem Robert LVEA Y Move a camera to a different view port 01:07
Images attached to this report
H1 General
ryan.crouch@LIGO.ORG - posted 00:02, Wednesday 03 July 2024 (78822)
PRC1/DRMI lockloss trending

I did some trending of the some LSC and ASC signals during the 3 DRMI locklosses from earlier. Here we have the 1st, 2nd, and 3rd lockloss and an example of a good lock from the last long lock before maintenance. I can see that the LSC INMON signals looked maybe twice as strong now compared to before. ASC_PRC1_YAW looks especially different than it did last night, ASC_PRC1_PIT_OUTMON seems to have changed sign to negative from positive. The PRM OSEMS don't look particularly different, a good lock from yesterday, DRMI LL from today.

Images attached to this report
H1 General (Lockloss)
ryan.crouch@LIGO.ORG - posted 19:55, Tuesday 02 July 2024 - last comment - 20:07, Tuesday 02 July 2024(78820)
02:53 UTC lockloss

https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1404010437

The wind has picked up a decent amount since the last lock aquisition so ALS will most likely have trouble staying locked. Gust are  >= 40 mph

Comments related to this report
ryan.crouch@LIGO.ORG - 20:07, Tuesday 02 July 2024 (78821)

From the windy.com forecast, the wind storms at its peak right now and will start to calm down around 07-08UTC / 23-01 PST.

H1 PSL (ISC)
jenne.driggers@LIGO.ORG - posted 17:47, Tuesday 02 July 2024 - last comment - 09:23, Wednesday 03 July 2024(78816)
Alignment of IMC, ISCT1, IFO in response to PMC swap today. PSL -> fiber distribution needs alignment tweak still

[Jenne, Sheila, Tony]

The PMC swap work earlier today (alog 78813) resulted in a slight shift of the alignment of the beams coming out of the PMC. 

After Ryan and Jason finished getting the ref cav aligned and locked, the IMC alignment looked poor.  I was able to mostly get it back by hand-moving the sliders for the PZT at the PSL periscope.  I touched MC2 a tiny bit, and then the IMC was able to lock.  I lowered the IMC WFS thresholds (eg  H1:IMC-IMC_TRIGGER_THRESH_ON and _OFF) so that it would take over alignment.  Once the alignment was pretty nearly finished, I used the IMC_LOCK guardian to offload the IMC WFS.  I saved in the safe.snap file for IMCASC the PZT offsets that had been offloaded.

In parallel, Sheila worked on the ALS system.  The initial goal was to check and adjust the PSL pickoff portion of the COMM beatnote, however Sheila noted that the ALS Xarm couldn't lock, since the end station PLLs weren't getting enough light from the PSL.  Sheila lowered the threshold of H1:ALS-C_FIBR_INTERNAL_DC_LOW from 0.05mW to 0.02mW, and also lowered H1:ALS-X_FIBR_LOCK_FIBER_LAUNCHLIM from 0.3 to 0.2 .  After this, the ALS Xarm was able to lock, and Sheila went out to ISCT1 and got the COMM beatnote up to about -1 dBm.  We then convinced ALS Yarm to lock after lowering H1:ALS-Y_FIBR_LOCK_FIBER_LAUNCHLIM from 0.3 to 0.2.  Sheila also changed H1:SQZ-FIBR_TRANS_DC_LOW from 0.2 to 0.05 mW and H1:SQZ-FIBR_LOCK_FIBER_LAUNCHLIM from 0.3 to 0.15, after which she was able to get the squeezer all locked up, so it seems like the squeezer should work fine when we get to that point this evening. 

Attached is the SDF screenshot that Sheila took for the squeezer thresholds.  The other ALS thresholds were also accepted in their safe.snap files.  All of these will need to be accepted in the Observe.snap SDFs in order for us to get to Observing. 

I helped the initial alignment a bit, by moving IM4 and PR2 a bit for the Input_align, and then moving PRM for PRC_align.  After that, initial alignment seemed to finish on its own. 

Particularly since we have been having ALS beatnote issues lately (see alog 78806 for some notes), we will almost certainly want to go into the PSL tomorrow to tweak the alignment of the optic that directs the beam to the fiber for the fiber distribution box, so that we can undo all these threshold changes.  Jason makes the good point that the longest part of doing that tweak will be garbing up for going into the PSL, so it should be quite easy.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 18:09, Tuesday 02 July 2024 (78818)

[RyanC, Jenne]

We lost DRMI lock 3 times in a row at the same place (without losing ALS lock), so it seemed like we had some DRMI alignment issues.  It turns out that we are barely on POP A QPD, which is not at all the same place that the offsets are set to.  For now, it seems to work well to take PRC1 out of the loop.  We'll need to take a look at it in the morning though.

jenne.driggers@LIGO.ORG - 18:17, Tuesday 02 July 2024 (78819)

Our 2W power recycling gain, before full IFO alignment is complete, is already above 60.  Usually in this state it is as high as 58, so this is unusually good.

We are very near the edge of IM4 trans, so dividing by a too-small number, which then makes our PRG artificially high.  That makes more sense, particularly since the arm transmissions aren't higher than usual.

camilla.compton@LIGO.ORG - 09:23, Wednesday 03 July 2024 (78828)

After Tony and I brought alignment sliders from HAM2 WD trip back 78823, the IMC locked and we moved IM3 (alot) to center the beam back on IM4 trans. Plot attached, IM3 sliders moved 450urad in Yaw, 40urad in Pitch. Jaosn is currently in the PSL so temperature changes may mean we need to readjust again later. May need to pico once we're at full lock with good range.

Usually with the IFO down and IMC locked, we have 1.91 on the IM4 trans nsum and centered beam (0.04 P, 0 in Y), plot. After the PSL alignment change yesterday we had 1.69 on the IM4 trans nsum and the beam mis-centered, mainly in yaw (0.3 P, 1 in Y) plot. See overall change here.

Images attached to this comment
H1 PSL (PSL)
ryan.crouch@LIGO.ORG - posted 17:28, Tuesday 02 July 2024 (78815)
Rotation Stage Calibration

After we finished up IA I ran the Rotation stage calibration following alog76890 and ran the python script to generate PSL_rotStageCalib_02July2024.txt (attached) and I accepted the new calibration values in SDF.

 

  Power in (W) D B (Minimum power angle) C (Minimum power)
Old Values 99.253 1.990 -24.830 0.000
New Values 102.488 1.990 -24.801

0.000

Images attached to this report
Non-image files attached to this report