Displaying reports 82461-82480 of 86303.Go to page Start 4120 4121 4122 4123 4124 4125 4126 4127 4128 End
Reports until 21:52, Wednesday 22 August 2012
H1 IOO
giacomo.ciani@LIGO.ORG - posted 21:52, Wednesday 22 August 2012 - last comment - 11:01, Tuesday 28 August 2012(3952)
HAUX build: structures ready
[Giacomo, Deepak]

After spending Monday collecting (chasing?) missing parts and Tuesday installing helicoils, today we were able to start (and finish!) some real assembly work. In particular we assembled:
- 6 HAUX towers, complete of almost all accessories
- 12 pairs of blades supports (including blades already paired for each suspension)
- 6 optic holders (excluding the magnets retro-fits)

We encountered virtually no problem. The quality of the attached picture is bad, but should be good enough to show the progress.

Tomorrow we will likely spend some time re-applying FC to the optics; then we'll proceed to the final steps of the assembly.

I'll refrain from optimistic forecasts about the completion of the job... :-)
Images attached to this report
Comments related to this report
giacomo.ciani@LIGO.ORG - 11:01, Tuesday 28 August 2012 (4011)
Sorry, numbers here are clearly wrong (proven by the pictures!). Correct ones:
- 5 HAUX towers, complete of almost all accessories
- 10 pairs of blades supports (including blades already paired for each suspension)
- 6 optic holders (excluding the magnets retro-fits) 
H2 ISC
bram.slagmolen@LIGO.ORG - posted 21:04, Wednesday 22 August 2012 - last comment - 16:40, Thursday 23 August 2012(3951)
OAT locked for the night.

[Alberto, Adam, Bram]

We locked the arm, with a jumpy RefCav. Starting time 21:04 local time, 22 August 2012.

The ETMY has the super sensor with the STS seismometer.

We did various WFS matirx measurements, came up with a matrix ... it looks wrong but seems to work. I set limits on the pit and yaw feedback signal and left them engaged for the night.

It is late, so more details later.

Comments related to this report
bram.slagmolen@LIGO.ORG - 22:04, Wednesday 22 August 2012 (3953)

Got home, check the locking status ... the arm had dropped lock .... I commanded 'caput H2:ALS-Y_REFL_SERVO_IN1EN 0' followed by 'caput H2:ALS-Y_REFL_SERVO_IN1EN 1'  and the cavity locked ... even more surprising it had a REFL power of 7000 ... and it started to move up automatically to 9200!! It seemed that the WFS are workingsmiley

Images attached to this comment
bram.slagmolen@LIGO.ORG - 00:59, Thursday 23 August 2012 (3954)

I tried to write an auto locker script but I hidiously failed. Although it may have something to do with a remote shell. I disengaged the REFL servo as it dropped lock and would not come back in the time I was trying to write the script.

alberto.stochino@LIGO.ORG - 09:46, Thursday 23 August 2012 (3957)

We centered the WFS and repeated the measurement of the sensing matrix. We did it in two ways: a) measuring the frequency response of the PIT and YAW outputs of both BFS A and B when exciting the POS and ANG mode of the cavity at about 4 Hz; b) introducing offsets in the cavity's POS and ANG degrees of freedom and measuring the displacement of the PIT and YAW output of the WFS.

The first method gave us almost degenerate sensing matrix. The second one seemed a bit better. The measured matrix M was:

M =
    0.0157   -0.7306         0         0
    0.0708   -0.6684         0         0
         0         0    0.0598    0.1663
         0         0   -0.0210    0.3363

The PIT and YAW inverted matrices were:

iP =
  -16.2163   17.7263
   -1.7176    0.3814
iY =
   14.2483   -7.0453
    0.8899    2.5339

These are the matrices used for the overnight arm cavity locking.

Th eigenvectors of these matrices are:

VP =
   -0.9931   -0.7741
   -0.1177   -0.6331

VY =
    0.9968    0.5341
    0.0795    0.8454

keita.kawabe@LIGO.ORG - 16:38, Thursday 23 August 2012 (3963)

(see below)

keita.kawabe@LIGO.ORG - 16:40, Thursday 23 August 2012 (3962)

This doesn't look crazy, though the two WFS heads are not optimally placed and the table astigmatism is not minimal either.

PIT sensing matrix that Bram posted in the above elog entry actually means this:

|WFSA| = |0.0157  -0.7306| x |POS| = |-0.7306  0.0000| x |-0.021  1| x |POS|
|WFSB|    |0.0708  -0.6684|    |ANG|    | 0.0000 -0.6684|   |-0.110  1|   |ANG|

The columns correspond to POS and ANG excitation, and the rows represent the WFS heads. (Sorry for the crappy formatting, I hope you get that I'm trying to write a matrix equation.)

POS refers to the translation of the cavity axis caused by the rotation of ETM and ITM in the opposite direction by the same amount. ANG refers to the rotation of the cavity axis by the rotation of the ETM and ITM in the same direction by the same amount.

For WFSA, ANG PIT generates a factor of 50-ish bigger signal than POS PIT. For WFSB, ANG IT is about a factor of 10 bigger.

Similarly, if you take the YAW matrix it's this:

|WFSA| = | 0.0598 0.1663| x |POS| = |0.1663 0.0000| x | 0.36 1| x |POS|
|WFSB|    |-0.0210 0.3363|    |ANG|    |0.0000 0.3363|   |-0.06 1|   |ANG|

If you look at the YAW numbers (not shown here but see the above entry by Bram), WFSA is a factor of 3-ish more sensitive to POS YAW than ANG YAW, and for WFSB this is a factor of 16.

Because of the cavity geometry (see below) ANG naturally produces a factor of 3 larger signal than POS. That means that, in terms of Gouy shift from the center of the cavity, WFSA for example is located at atan(-0.021*3) = -3.6 degrees away for PIT. Note that there's an uncertainty of n times pi that is common to all DOFs, and also the sign is sort of arbitrary though it should be consistent for both WFSs.

Anyway, below is the table of Gouy shift: from the waist of the arm in degrees (the above caveat about uncertaintly applies).

           PIT         YAW 
WFSA |  -3.6 deg | +47   deg|
WFSB | -18   deg | -10.6 deg|

PIT and YAW difference in WFSA looks kind of suspiciously large, but I would say that the crappy beam quality on the table could be blamed. It's not the TMS telescope (if it is, we'll see the same thing in WFSB too).

All in all the WFS locations could be adjusted better, and certainly the beam on the table is not passing through the center of lenses, but if the servo works (which we'll find eventually) I'll leave it.

 

----

Why a factor of 3 naturally?

Because we're using ETM substrate for both ETM and ITM, ROC of both is about 2300 m (2312 for EY, 2307 for IY).

Waist (w0=11.5mm for green) is at the center of the cavity, and the divergence angle is theta0=14.6 urad.

If we rotate both of the mirrors by the same amount (theta) as if one is the mirror image of the other, the cavity axis is purely translated by 2000m*theta. In terms of the higher order mode excitation, this is equivalent of

Normalized POS = 2000m * theta / w0 = 1.7e5 * theta.

ANG: If we rotate both of the mirrors by the same amount (theta) in the same direction, the cavity axis is purely rotated around the waist by (2300m * theta * 2)/600m. This is equvalent of

Normalized ANG = (2300m * theta * 2)/600m/theta0 = 5.3E5 * theta.

Therefore a factor of 3.

LHO General
patrick.thomas@LIGO.ORG - posted 19:43, Wednesday 22 August 2012 (3949)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Non-image files attached to this report
H1 IOO
david.feldbaum@LIGO.ORG - posted 19:09, Wednesday 22 August 2012 (3947)
IO FI alignment in PSL

This morning we noticed that the magnetic rotator is not in full contact with its mount. Cheryl identified the problem as due to the fact that the thru-holes drilled in the restraining Omega-shaped rings are not well matched to the corresponding screw-holes in the mount. I gave her the restraining rings for adjustment.

This means that the magnetic rotator is not secured in its mount at the moment. I will not be placing any optics (TGGs and Quartz) inside the magnet until it is secured (required for steps 20-on of the procedure in E0900301).

I have gone through steps 1 thru 19 of E0900301 (at low powers only).

Steps 16-17, s-pol extinction by the 1st Calcite Wedge Polarizor:

s-pol extinction by 1st CWP
incident trans s-pol extinction
1 W 0.59 µW 62.2 dB
5 W 0.13 mW 45.8 dB
10 W 0.26 mW 45.8 dB

Step 19, s-pol extinction by both CWPs:

s-pol extinction by both CWPs
incident trans s-pol extinction
9.85 W 0.313 mW 45.0 dB

Some more adjustment is needed to get to the required extinction of 50 dB.

H1 SEI
hugo.paris@LIGO.ORG - posted 18:11, Wednesday 22 August 2012 - last comment - 10:23, Wednesday 29 August 2012(3948)
HAM2-ISI - Testing progress

Electronics were troubleshooted.

SEI and SUS models were arranged to allow un-tripping HAM2-ISI Payload Watchdogs.

HAM2 model was re-compiled, installed and re-started after that. It is now running.

Matrices were filled

Input and output filters are loaded

The latest version (Version_2) of the unit-specific control scripts were copied from LASTI. They were made ready for use on HAM2. 

Spectra were taken on the ISI tilted. It is the worse configuration for GS13s and they all appear to be working fine (see attached plot).

Transfer function measurements are running overnight.

Images attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 16:45, Thursday 23 August 2012 (3965)

The transfer functions measured last night had features that are typical to mis-connected sensors/actuators. Deeper analysis allowed narrowing it down the the GS13s. 

We made a program to check for "cross-coupling transfer functions" (e.g. drive on H1, response on H2). It revealed that:

H1-GS13 was read on the channel of H3-GS13 
H2-GS13 was read on the channel of H1-GS13
H3-GS13 was read on the channel of H2-GS13
V1-GS13 was read on the channel of V3-GS13 
V2-GS13 was read on the channel of V1-GS13
V3-GS13 was read on the channel of V2-GS13

We checked our model and did not find a cause for such behaviour there. We moved on the the electronics rack and spotted the issue: GS13 In-field cables were connected to the wrong inputs on HAM2 sensor interfaces.

We ran a quick TF measurement between 500mHz and 5Hz. It confirmed that the sensors were now all correctly connected. This quick measurement is also in good accordance with what we measured on HAM-ISIs in the past which is encourraging.

TF measurement are running overnight on HAM2. They will be over by 7am. 

 

Note: A blinking notification was recently added to HAM-ISI overview MEDM screens (see attachement). It turns the green "measurement" button to blinking yellow when a TF is running. HAM2 overview screen can be seen on the Video6 monitor of the Control Room. 

Images attached to this comment
hugo.paris@LIGO.ORG - 10:23, Wednesday 29 August 2012 (4025)

Hugh and I added screwdriver tips under the top payload mass of HAM2-ISI last week, before the chamber was closed. They helped prevent this big mass of ~600lbs from causing unwanted resonances. Befoire/After comparison plots are attached.

We compared the latest transfer functions with the ones taken on LLO HAM2-ISI during the same phase of testing (Intitial In-Chamber Testing). Plots are attached. Accordance is good. We are confident that the unwanted resonance seen at 96Hz comes from the top mass. We plan on ajusting its boundary conditions with the optical table once the doors of HAM2 chamber are open again. 

Non-image files attached to this comment
LHO General
michael.rodruck@LIGO.ORG - posted 16:27, Wednesday 22 August 2012 (3946)
Ops summary
H2 SEI
vincent.lhuillier@LIGO.ORG - posted 15:48, Wednesday 22 August 2012 (3943)
Sensor correction at HEPI-BSC6 - First try

I have implemented the sensor correction at HEPI-BSC6. Sensor correction improves the isolation performances of the HEPI in the X, Y and Z directions. In attachment, spectra of the L4C installed in the HEPI boots are presented in different configurations:

Non-image files attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 15:45, Wednesday 22 August 2012 (3944)
WHAM2 Post IAS ISI Elevation Set
JimW CoreyG HughR

With IAS signing off on position yesterday, we did a final check on elevation/leveling and did need to make some vertical adjustments.

We ended up with the Optical Table 0.1mm high at -240.3mm and level to 100urad (+-0.1mm)

These vertical adjustments barely moved the system horizontally--based on Dial Indicators the sw & se corners moved 1 & 2 mils (<0.05mm).

So we have locked up the HEPI and are now doing ISI measurements.  We will continue with ISI testing, then attached HEPI Actuators, followed by a post install (actuators) IAS check if dial indicator readings suggest it is warranted.

Attached is the surveying and dial indicator readings logbook page.
Non-image files attached to this report
H2 CDS
bram.slagmolen@LIGO.ORG - posted 15:14, Wednesday 22 August 2012 (3942)
SNAP files

[Jeff G., Bram]

Made new safe.snap files for ISCEY, ETMY, TMSY and ITMY.

LHO VE
kyle.ryan@LIGO.ORG - posted 14:52, Wednesday 22 August 2012 (3940)
Soft-closed GV5


			
			
H1 SUS
jeffrey.garcia@LIGO.ORG - posted 14:19, Wednesday 22 August 2012 - last comment - 14:45, Wednesday 22 August 2012(3936)
H1 SUS HAM2 user models broadcasting manufactured errors
The H1 suspensions on HAM2 are currently broadcasting a constant "0" as the watchdog state to other FrontEnds on the Dolphin network via an IPC library part. This value satisfies the HAM-ISI Simulink model condition for a "0" input in order to prevent the triggering of the "DACKILL" functionality. To further complicate the issue, the error signal from the receiving IPC part on the HAM-ISI model is currently reading out a non-zero error, meaning their is a communication issue on the Dolphin network.  A bypass on the receiving model ("h1isiham2") in the form of a constant "0" for the communication error will enable the functionality of actuation from the HAM-ISI user model.

The true watchdog signal from the SUS models will be broadcast as soon as the Dolphin network communication issue is resolved.



Comments related to this report
hugo.paris@LIGO.ORG - 14:45, Wednesday 22 August 2012 (3939)

h1isiham2.mdl was modified to apply a constant at the error input of the HAM2_PAYLOAD block (see attached picture). The constant value is 0. It corresponds to the Dolphin communication error value for the state of SUS model running

Modifications were commited to the SVN. The model was re-compiled, installed, and re-started.

It allowed untripping the ISI. Actuation is now possible. Actuators respond on all corners, and they appear to be correctly wired.

 

This modification of h1isiham2.mdl will have to be reversed when rcg is updated on site (planned for 08/28/2012). 

The modifications applied to SUS's models will need to be reversed when suspensions are installed on the ISI.


		
		
Images attached to this comment
Logbook Admin Feature Requests
jeffrey.garcia@LIGO.ORG - posted 14:04, Wednesday 22 August 2012 - last comment - 14:25, Wednesday 22 August 2012(3935)
Requests
Ability to log out a user out and not have the previous users info saved, so I can log him out and log myself in without clearing cookies. This is not Jeff Garcia.

Also, I'd like to be able to add captions to attached files.
Comments related to this report
jonathan.hanks@LIGO.ORG - 14:25, Wednesday 22 August 2012 (3937)
The logout issue is a known limitation with the LIGO.ORG authentication on shared workstations.  You need to completely close/kill the browser, or open a different browser (not just a different browser window).

The authentication is not handled by the application, it is handled by the LSC auth project login server (login.ligo.org).  Clicking aLOG log-out button does in fact clear all state in the application associated with your session.  The issue is that the aLOG does not have a way to affect the state of login.ligo.org.

So this is a known issue, it will be fixed at some point.  The benefit in account and password management of using the LIGO.ORG credentials appears (by far) to outweigh the inconvenience of having to kill the browser when you work at a shared workstation.
jeffrey.kissel@LIGO.ORG - 14:25, Wednesday 22 August 2012 (3938)
The first of your requests has been a request since last summer, see LHO aLOG 1000. I know Jonathan Hanks is working on this.
H2 CDS
david.barker@LIGO.ORG - posted 13:28, Wednesday 22 August 2012 - last comment - 15:04, Wednesday 22 August 2012(3934)
EY front ends restarted, new h2tcsetmy model installed

We had a timing glitch at EY which required a restart of all EY front ends. I took the opportunity to install the new h2tcsetmy model for the ring heater.

I did a manual burt restore of the safe.snap files and found problems with

I'll fix the ones marked *

Comments related to this report
bram.slagmolen@LIGO.ORG - 15:04, Wednesday 22 August 2012 (3941)

I restored ISCEY, ETMY and TMSY to 3am, 22 August 2012.

H2 SEI
vincent.lhuillier@LIGO.ORG - posted 11:43, Wednesday 22 August 2012 (3933)
CPS-L4C-T240 in the 250mHz stage 1 blend

I have attached 2 plots:

LHO_ISI_ITMY_Calibration_Check_Stage_1_Sensors_201208022.fig shows the calibrated transfer function from the Y drive to CPS, L4C and T240 on ITMY. Calibration is OK. LHO_ISI_ITMY_Calibration_Check_Super_Sensor_201208022.fig shows the contribution of each sensor in the stage 1 250mHz blend in the Y direction. The calibrated TFs are slightly different in the 2 figures due to the introduction of the calibration correction gain to improve the blend  (amplitude - phase).

H2 AOS
jeffrey.kissel@LIGO.ORG - posted 09:29, Wednesday 22 August 2012 (3932)
Re-restore ITMY Optical Lever Calibration
After Robert's presentation on magnetic coupling today at the Systems meeting, I wanted to double check that the calibration in place were the final numbers that Thomas and I had calculated, having remembered that the incorrect numbers were stored in the safe.snap, and were restored incorrectly a few weeks ago.

When there is down time in the cavity commissioning: please turn off the suspension and grab a new safe.snap.


ETMY's numbers are confirmed to be correct.
H1 PSL
michael.rodruck@LIGO.ORG - posted 16:33, Monday 20 August 2012 - last comment - 16:00, Wednesday 22 August 2012(3898)
DC power connected

Filiberto, Richard, Michael R

The PSL was moved off of the temporary power supplies for 24, 18 and 12V and is now running on the DC power supplies in the H1 electronics room. For the moment, we are still running on the temporary power supplies for high voltage (400V for PMC/ILS, and 180V for FSS), however they were moved into the PSL rack to free up room. The purple cables in the electronics room were redressed as well.

The PSL servos and laser were shutdown for this work, and the key from the control box was removed to make the laser and ante room laser safe (to make David Feldbaums work easier). I plan on turning the laser on tomorrow morning, so it will be off for the night. If all goes well with David's work we may go to high power tomorrow as well.

Comments related to this report
michael.rodruck@LIGO.ORG - 16:00, Wednesday 22 August 2012 (3945)

Laser was restarted yesteday, with the FSS and PMC servos running. The ISS is off because it keeps glitching with work on the table. Watchdogs are on.

Displaying reports 82461-82480 of 86303.Go to page Start 4120 4121 4122 4123 4124 4125 4126 4127 4128 End