Displaying reports 82661-82680 of 86345.Go to page Start 4130 4131 4132 4133 4134 4135 4136 4137 4138 End
Reports until 18:39, Thursday 09 August 2012
H1 TCS
aidan.brooks@LIGO.ORG - posted 18:39, Thursday 09 August 2012 (3789)
Ring Heater OFF

I turned off the ETM ring heater at 1:37:50 UTC.

H1 SEI
hugo.paris@LIGO.ORG - posted 18:14, Thursday 09 August 2012 (3788)
HAM2-ISI & HAM3-ISI -- models Updated and Installed

DaveB, JimB, HugoP

 

Models were recently updated at LLO so they can use Dolphin. Updates were transfered over to LHO. HAM3-ISI model was re-installed.

We also seized the opportunity to install HAM2-ISI model which is now running.

MEDM screens for HAM2-ISI were added to the VIDEO6 display of the control room, next to the ones of HAM3-ISI.

The arborescence, and the unit-specific testing-programs for HAM2 were created.

Coordinate transform matcices were filled for both ISIs.

X1 SEI
hugo.paris@LIGO.ORG - posted 18:08, Thursday 09 August 2012 - last comment - 09:37, Friday 10 August 2012(3786)
HAM-ISI Unit #7 - Assembly Validation Progress

CoreyG ,HugoP

Transfer functions ran overnight yesterday. Unwanted resonances are present in the vicinity of 130Hz, on all DOF. The usual suspect is then the 600lbs payload mass set on top of the ISI. One can hear it resonating when being hit. The washers it was sat on were too close from each other. Corey and I lifted this top mass with a fork lift and reset the washers. The mass would vibrate way less when being hit afterwards.

Transfer functions are running overnight.

Comments related to this report
hugo.paris@LIGO.ORG - 09:37, Friday 10 August 2012 (3801)

Moving the washers had the intended effect. It suppressed the unwanted resonances. 

Before/After plots are attached

Non-image files attached to this comment
LHO General
james.batch@LIGO.ORG - posted 17:51, Thursday 09 August 2012 (3785)
Video3 Mac Mini crash
video3, which displays the psl enclosure cameras in the control room, died spontaneously with a message in several languages stating it needed to be powered off.  So it was powered off and turned back on.  Someone who knows the passwords to the cameras will need to enter them to get the video to display again.
H1 TCS
aidan.brooks@LIGO.ORG - posted 16:47, Thursday 09 August 2012 (3783)
HWS noise floor improvement -

I'm concerned that trying to solve for higher order optical aberrations coupled with motion of the HWS beam is causing problems in the parameterization of the HWS data. I ammended the HWS code to limit the parameterization of the wavefront gradient measurement to only pitch/yaw, spherical and cylindrical power. Additionally, I lowered the threshold on the intensity of acceptable spots to centroid on the HWS, increasing the number from 24 to 45. The noise in the measured spherical power was significantly reduced as a result (mostly from the simplification of the parameterization).

A plot of the measured spherical power noise floor referenced to the ETM is attached. The scale may be off in absolute magnitude by up to 20% due to the lack of a measurement of the magnification of the optical system as installed; the plot assumes the nominal 20x magnification.

Non-image files attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 16:17, Thursday 09 August 2012 (3782)
Septum separating HAM5-HAM6 passes final annulus leak test
The HAM5 and HAM6 annulus ion pumps demonstrated their ability to maintain the annulus pressure (unassisted by aux. carts) for greater than 2 days with ion current values of 5 LEDs and 6 LEDs respectively.  This was done while the Vertex was under vacuum.  Additionally, no pressure communication was observed on the Vertex MTP CC gauge (@ 3 x 10-7 torr) when the HAM5-HAM6 annulus volume was vented.  
LHO General
jeffrey.garcia@LIGO.ORG - posted 16:07, Thursday 09 August 2012 (3779)
Ops Log
craning in LVEA in the morning
SEI crew near HAM3 for cabling and such
reboots of Simulink user models for FMY, ITMY, & ETMY
SURFs to the Mid-Y and End-Y stations
dome and door install on BSC9
LHO VE
kyle.ryan@LIGO.ORG - posted 16:06, Thursday 09 August 2012 (3781)
Leak testing of all of the conflat joints on the Vertex chambers BSC1, 2, 3, HAM4, 5, 6 and output MC tube is complete
A final tally of 7 ea. total conflat joints could not be made leak-tight in-situ and will need to be reflanged/repaired at some point following the vent.  A quick testing of the welds on the MC output spools will be done just prior to tomorrow's vent.
H1 FMP
jodi.fauver@LIGO.ORG - posted 15:09, Thursday 09 August 2012 (3778)
Xend Prep
The dome and two doors were returned to BSC9 this afternoon in preparation for the flooring install that is due to start next Wednesday.
H2 SUS
jeffrey.garcia@LIGO.ORG - posted 14:48, Thursday 09 August 2012 (3777)
H2 SUS FMY Simulink model updated
Updates were made to the FMY Simulink user model "h2susfmy" in incorporate the ISI to SUS transformation inputs to the BSFM_MASTER model. There were also three ISC control outputs to BSFM_MASTER that were removed.  The FMY model has been compiled, installed, and begun on 'h2susb78'.

The top level custom model is committed to the CDS SVN locally in:
'/opt/rtcds/lho/h2/userapps/release/sus/h2/models/'

The common library part "BSFM_MASTER" is saved locally in:
'/opt/rtcds/lho/h2/userapps/release/sus/common/models/'

H1 IOO
dale.ingram@LIGO.ORG - posted 11:31, Thursday 09 August 2012 (3776)
MC2 Installation Photos
MC2 went into HAM3 on 8/6/12.  View the photo collection in ResourceSpace.
Images attached to this report
H1 DAQ
james.batch@LIGO.ORG - posted 10:51, Thursday 09 August 2012 (3775)
Restarted daqd process on h1fw1
Found that the daqd process had quit on h1nds1.  Last error message in the log file:

Invalid broadcast received; seq=17427618 tp_seq=17427618 gps=1028550222 tp_gps=1028550222 gps_n=62500000 tp_gps_n=125000000

Restarted daqd process.

Note that the daqd process failed in a similar manner on h2nds0 August 6, 2012
H2 AOS
jeffrey.kissel@LIGO.ORG - posted 09:12, Thursday 09 August 2012 (3773)
New Calibration installed into Optical lever path
J. Kissel, T. Vo

Now that we've [cleaned up/corrected] our analysis of the optical lever calibration (see LHO aLOG 3758), I've installed the new numbers into the appropriate gain field in the optical lever path, H2:SUS-${OPTIC}_L3_OPLEV_${DOF}_GAIN.

The optical levers need centering before new spectra of the calibrated channels can be taken, though.

BUT, the calibration factor has been reduced by 
DOF        Before / After
ITMY P         22.359
ITMY Y         22.382
ETMY P         30.556
ETMY Y         30.544
because we fixed the controller counts to translation stage calibration (from 0.6 [mm/ct] to 6 [um/ct]), used more accurate lever arms (2*L, from 70 [m] and 6 [m] to 56.4 [m] and 6.6 [m]), and threw out some outlier data to get a better linear fit.

Reducing the expected RMS spot motion (on the ETMY, in Pitch, see LHO aLOG 3727 for full explanation of calculation) to 

| dx | = | dTheta_E * L * g / (1 - g^2) + dTheta_I * L / (1 - g^2) |
       = (50e-6/30.556) [rad] * 4e3 [m] * -0.8 [] / (1 - (-0.8 [])^2 ) + (5e-6/22.359) [rad] * 4e3 [m] / (1 - (-0.8 [])^2)
       = 0.012 [m]

or 1.2 [cm], which albeit still large from a performance stand point, is much more believable given what is visible on a camera.
H1 TCS
aidan.brooks@LIGO.ORG - posted 06:59, Thursday 09 August 2012 (3770)
ETMY Ring Heater ON at 30W

I just turned on the ETMY ring heater to 630mA for each segment to measure the thermal lens with the Hartmann sensor beam.

X1 SUS
jeffrey.garcia@LIGO.ORG - posted 21:43, Wednesday 08 August 2012 (3769)
X1 MC3 SAGM1 WhiteNoise TFs with damping ON & OFF
The first attachment contains plots of all DoFs on MC3 SAGM1 taken last week with DAMPING OFF.  The second attachment plots data from last night with SAGM1 DAMPING ON.   
Non-image files attached to this report
H1 SUS
betsy.weaver@LIGO.ORG - posted 19:42, Wednesday 08 August 2012 - last comment - 16:06, Thursday 09 August 2012(3767)
HAM2 install work

Today, Filiberto re-routed the external MC2 (and the 1 shared PR2 cable) from the chamberside test area to the chamber feed thru.  From there we spent a little time finding a cable swap and remedying.  ( I *think* the switch is related to the callout of "flooring" positions of the cabble connectors in the cable table brackets.)  We then set the 6 TOP BOSEMs to 50% OLV.  We can now run TFs to kick off SUS Phase 3a testing here.  Not entirely sure who will do this - possibly me when I get in midday.

PR2 glass install chamberside was stalled another day as we discovered contamination on the AR surface in many places (smudges as well as FirstContact overspray?).  We will need to spend some time drag wiping this tomorrow and and then re-attemp the install.

UFl and SEI should feel free to spend some morning time working on table payload if they want/need.  Any MC2 TFs in-progress will be posted or announced.

Images attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 19:44, Wednesday 08 August 2012 (3768)

Hugh and Mitch adding Ballast Masses to HAM3-West.

Images attached to this comment
hugh.radkins@LIGO.ORG - 07:48, Thursday 09 August 2012 (3771)
Thanks Betsy--We added the first layer of 10kg masses (D0901075) at nine locations per D1000907-v1.  These are all on the West side to aide in cable routing.  Apologies for the interference for some that these will present.  These masses are not bolted down but they are accurately placed.  We will add the second layer soon to locations deemed out of the way and to others when work needing better access is complete.
filiberto.clara@LIGO.ORG - 16:06, Thursday 09 August 2012 (3780)
Here is a list where the cables were landed for MC2 and PR2 to the feedthrus. 

Feedthru D6-1C1 MC2 BOT H1:SUS_HAM-20
Feedthru D6-1C2 MC2 TOP H1:SUS_HAM-1
Feedthru D6-2C1 MC2 MID H1:SUS_HAM-19
Feedthru D3-1C1 MC2/PR2 H1:SUS_HAM-2
Feedthru D3-1C2 MC2 BOT H1:SUS_HAM-26
Feedthru D3-2C1 MC2 TOP H1:SUS_HAM-3
Feedthru D3-2C2 MC2 MID H1:SUS_HAM-25

Documents that show the feedthrus and cabling: D1002874 and D1000599.
H2 ISC
bram.slagmolen@LIGO.ORG - posted 18:22, Wednesday 08 August 2012 - last comment - 19:21, Thursday 09 August 2012(3764)
OAT locking performance

Attached is a spectrum from last night (7 August 2012), starting a ~23:30h.

There seems to be a narrow spike at 700mHz, while the 2.74 Hz peaks are still there. I guess we nudging downwards ...

Images attached to this report
Comments related to this report
bram.slagmolen@LIGO.ORG - 19:21, Thursday 09 August 2012 (3790)

I added the RMS to the latest spectrum.

Images attached to this comment
H2 ISC
jaclyn.sanders@LIGO.ORG - posted 09:31, Wednesday 08 August 2012 - last comment - 08:05, Thursday 09 August 2012(3746)
Cavity Characterization: Preliminary Results

This is the transfer function between the phase-frequency discriminator and the FET IQ demodulator while the cavity is locked. The blue trace is "initial" conditions, i.e., with a well-aligned cavity and standard modulation sidebands. The green "sb shift" trace was taken with the RF modulation sideband frequency tuned 200 Hz higher than its initial value. The red "alignment shift" trace was taken with the ITM yaw misaligned. 

The FSR is 37.512 kHz, with a higher-order FSR peak at 75.018 kHz. Given this FSR, the cavity length is 3995.95 m.

The peaks due to the RF modulation sidebands are at 54.432 kHz and 58.098 kHz in the initial trace. These peaks shift 200 Hz in the green trace.

Additional structure is observed at 46.301 kHz, 55.325 kHz, 57.252 kHz, and 66.229 kHz. The peaks at 46.301 kHz and 66.229 kHz increase for the case of yaw misalignment and are thus likely to be (1,0) modes. 

The separations between these peaks are:

75.018 - 66.229 = 8.789 kHz

66.229 - 57.252 = 8.977 kHz

46.301 - 37.512 = 8.784 kHz

55.325 - 46.301 = 9.024 kHz

The mean modal spacing is 8.8935 kHz.

From this modal spacing, the g-factor is 0.540532, corresponding to approximate mirror radius of curvature of 2302.86 m. 

The FWHM of the FSR peak is approximately 94 Hz. Finesse is thus 37512/94 = 399.064. This would occur for a reflectivity of about 99.2%.

There's a follow-up of this in the works for characterizing cavity properties during ring heater use.

Images attached to this report
Non-image files attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 08:05, Thursday 09 August 2012 (3772)
The RF frequency is 24.515730 MHz and was shifted to 24.515930 MHz for the second measurement. Making the ansatz

f_SB = (N - 1) * f_FSR + f_mease 

with f_FSR ~ 37.51kHz, N an integer, and f_meas = 58.098 kHz, we determine 

N = 653

Now, we can go back and recalculate f_FSR = 37511.71 Hz with a few ppm precision. This then yields L_arm = 3995.985m.
Displaying reports 82661-82680 of 86345.Go to page Start 4130 4131 4132 4133 4134 4135 4136 4137 4138 End