camilla.compton@LIGO.ORG - posted 15:22, Wednesday 26 June 2024 (78688)
New MICH FF ready in FM5

Jennie, Camilla

After Jennie's 78629 measurements, we fit the MICH FF for hot OM2 with Gabriele's InteractiveFitting tool (SRCL done in 78632). It's loaded in FM5 and we plan to test it tomorrow morning during commissioning.

Images attached to this report
H1 SQZ (SQZ)
karmeng.kwan@LIGO.ORG - posted 15:20, Wednesday 26 June 2024 - last comment - 05:23, Thursday 04 July 2024(78686)
SHG2 Sinc Twin Sisters Rock Curve

Built a second SHG with the PPKTP crystal from MIT, did a measurement on the conversion efficiency and fit for the single pass nonlinear conversion efficiency Enl = 0.0055W-1. The single pass measurement of the PPKTP crystal give a nonlinearity deff = 5.41 pm/V. Generally deff of PPKTP is quoted around 9.3pm/V (Table 5.1 of Georgia's thesis)

Measurement of the phase matching curve with input power of 60 mW shows a dip around 35 celcius. The temperature controller reads in kOhm and is converted into celcius via the Steinhart-Hart equation:

A1 = 0.003354016
B1 = 0.0002569850
C1 = 2.620131e-6
D1 = 6.383091e-8

R25 = 10000
R = R_meas / R25
T = ( 1 / (A1 + (B1 * np.log(R)) + (C1 * np.log(R)**2) + (D1 * np.log(R)**3) ) ) - 273.15

Phase matching curve is plotted by using Equation 3.14, 3.20 and Table 3.2 from Sheila's thesis. I have fitted the sinc curve with T0 = 34.9 and i_max = 11.79 , 18.00 and 32.00.

Images attached to this report
Non-image files attached to this report
Comments related to this report
naoki.aritomi@LIGO.ORG - 15:45, Wednesday 26 June 2024 (78690)

Mount Saint Helens for our currently used SHG: 76239

nutsinee.kijbunchoo@LIGO.ORG - 05:23, Thursday 04 July 2024 (78858)SQZ

I found a single/double pass SHG study that was done for the Virgo squeezer by Leonardi et al. here https://iopscience.iop.org/article/10.1088/1555-6611/aad84d

Daniel pointed out that Eq.2 from this paper shows an "additional phase from the red/green dispersion in the rear mirror turn around path" in the double pass scheme. I've attached a couple plots as a function of arbituary x (this variable is related to delta T) at various phase mismatch delta phi. I think the phase mismatch between the red and the green in the double pass alone might explain most of the mountains we are seeing here (?). this might not be the answer to all the problems but it's a good place to start (Figure 7 also looks very interesting).

 

Maybe the mountains can be patched up if we have a capability of translating one of the mirrors.

Images attached to this comment
H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 15:08, Wednesday 26 June 2024 (78687)
Lockloss

Lockloss @ 06/26 22:04UTC - most likely from wind

Images attached to this report
H1 OpsInfo
thomas.shaffer@LIGO.ORG - posted 13:53, Wednesday 26 June 2024 (78685)
Small change to ALS guardians to avoid last night's issue

Last night the ALS_XARM node was stuck in a loop of tryin to go to increase flashes but Beckhoff was reporting some errors (PDH, PLL, others) so the node would jump to fault state (see Oli and Ryan C's alog78669). There were two issues I found: the unstall decorator that re-requested the node to jump out of FAULT only looks for Beckhoff error messages which might be temporarily not present, and the FAULT state has a jump transition in it to allow us to go to UNLOCKED. I have three possible solutions for this:

  1. Line 208 of ALS_ARM.py forces a jump transition to UNLOCKED while in the FAULT state if the target state is unlocked. Based off of a comment in the code there, I believe the intent was to allow us to still go to unlocked if ALS is shuttered. This isn't desireable because I can't really see another state that would be the target, so it will always jump out of this FAULT state. Changing this line from looking at the target state to the request state should allow it to stay in fault unless we want it to go to unlocked.
  2. Make the unstall node decorator smarter looking at more than just if there are any node notifications. In this case the notifications would only come from Beckhoff error messages, so this isn't good enough at times since the messages can flash by or temporarily go away.
  3. Create a state just before Increase_Flashes that does a check of the ALS Beckhoff errors and will wait here until they are cleared. I worry that this will not be a clear enough indicator that we are in an error state though. It also could create a way to get stuck here and force more user intervention.

For now we'll try option #1 and see how that works. If we need to make it more sophisitcated we can test it out. The code with this change has been saved and will be reloaded when we drop out of Observing.

Images attached to this report
H1 General
oli.patane@LIGO.ORG - posted 12:32, Wednesday 26 June 2024 (78684)
Ops DAY Midshift Status

We are Observing at 154Mpc and have been Locked for 2.5 hours. Nothing to report.

H1 CDS
david.barker@LIGO.ORG - posted 11:27, Wednesday 26 June 2024 - last comment - 11:30, Wednesday 26 June 2024(78681)
h1susex DAC and Timing Card Temperatures

RCG5.3.0 reads out the FPGA chip temperatures for both the Timing Card and the new LIGO 28AO32 DAC card. These are available as EPICS channels and can be trended in ndscope.

The attached image shows the past 24 hour trend, and where you can find these temperatures on the RCG MEDMs.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 11:30, Wednesday 26 June 2024 (78682)

Note that because of heating concerns, Marc installed a third cooling fan on the h1susex IO Chassis utilizing the square hole in the front of the chassis which used to house the Columbia timing stack. The new DAC is centered on the 3rd Adnaco backplane, squarely in front of this fan.

H1 TCS
oli.patane@LIGO.ORG - posted 11:14, Wednesday 26 June 2024 (78680)
TCS Chiller Water Level Top-Off FAMIS

Closes FAMIS#27792, last checked 78496

TCSX: Originally at 29.6. Added 300mL to get to 30.1

TCSY: Already at 10.4. Nothing added.

No leak in water cup

H1 General
andrei.danilin@LIGO.ORG - posted 11:01, Wednesday 26 June 2024 (78679)
Bouncing modes in SQZ-FC_LSC_DOF2

Andrei, Sheila

We've observed that upon IFO switching its state to OBSERVING (H1:GRD-IFO_OK), we observe the so-called bounce modes of mirror suspencions at freqeuencies around 27.041 Hz in H1:SQZ-FC_LSC_DOF2 channel. These modes can be present in measurements for over 10 minutes. We have checked the occurances of these events over a few days, which will hopefully help us to determine the exact suspencion responcible for this behavior (Bouncemodes.png/ligo/home/andrei.danilin/Documents/Oscillations.xml).

 

Images attached to this report
H1 SYS
sheila.dwyer@LIGO.ORG - posted 10:56, Wednesday 26 June 2024 (78667)
looking for fast shutter checks for AS_C clipping in DRMI

TJ, Sheila

The fast shutter guardian runs a check in DRMI on AS_A and AS_B, it checks that the power on those PDs are above and below thresholds, which are set by the 'SYS-MOTION_C_SHUTTER_G_TRIGGER_LOW' and 'SYS-MOTION_C_SHUTTER_G_TRIGGER_HIGH' channels.   This test was passed when we had the pressure spikes, because the beam to those diodes wasn't clipped.

TJ and I have been discussing adding an additional check to try to catch the type of problem we had in our recent pressure spikes, where there was clipping on AS_C.  The table below shows values with DRMI locked, to see if we can detect the problem before fully locking the IFO.  It seems that a check on the power on AS_C would cause false alarms, because of the variablity of DRMI build ups.  A check on the ratio of AS_C to AS_A or AS_B seems more viable, but still would probably risk false alarms.  The difference between the lowest "good" ratio for AS_C/AS_A and the highest bad ratio is only 3.5%, for AS_C/AS_B that difference is only 7%. 

  AS_C NSUM (W in HAM6) AS_A NSUM AS_ B NSUM AS_C/ AS_A AS_C/ AS_B
6/6 20:46 UTC (bad) 0.046 3908 4240 1.17e-5 1.08e-5
6/7 2:30 UTC (bad) 0.049 4162 4515 1.17e-4 1.08e-5
6/7 3:20 UTC (bad) 0.048 4145 4488 1.15e-5 1.07e-5
6/6 12:08 (good) 0.052 4240 4433 1.22e-5 1.16e-5
6/6 7:10 UTC (good) 0.0506 4098 4267 1.23e-5 1.18e-5
6/6 5:21 UTC (good) 0.053 4361 4575 1.21e-5 1.16e-5
6/6 00:56 UTC (good) 0.048 3943 4105 1.21e-5 1.17e-5
6/5 23:44 UTC (good) 0.053 4319 4513 1.23e-5 1.17e-5

 

LHO VE
david.barker@LIGO.ORG - posted 10:52, Wednesday 26 June 2024 (78678)
Wed CP1 Fill

Wed Jun 26 10:09:07 2024 INFO: Fill completed in 9min 3secs

Gerardo confirmed a good fill curbside.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 10:44, Wednesday 26 June 2024 - last comment - 10:51, Wednesday 26 June 2024(78676)
LIGO 28AO32 h1susex DAC Test MEDM

I've written a python program which genenerates a DAC_TEST MEDM. It is accessible from the SITEMAP via the WD pull down (the CDS pull down is full).

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 10:51, Wednesday 26 June 2024 (78677)

Currently the first 8 DAC channels are routed to the ADC on h1pemex (first 8 channels). This is achieved using a custom DB25 cable, which connects to one of the 4 DAC inteface plates on the back of the IO Chassis and splits these channels into 8 BNC cables which are connected to the first 8 channels of the PEM AA chassis.

Note that this is a standard PEM AA chassis, with a gain of 10.

By moving this cable between the IO Chassis interface/header connectors, the new DAC's channels can be tested 8 at a time.

The h1susetmx DAC_MTRX permits any signal to be routed to these ADC channels.

H1 CDS
david.barker@LIGO.ORG - posted 10:38, Wednesday 26 June 2024 (78671)
CDS Maintenance Summary: Tuesday 25th June 2024

WP11928 Install New LIGO-DAC in h1susex

Richard, Marc, Fil, Erik, EJ, Dave:

A new LIGO 28bit DAC card was installed in h1susex. The current 18 and 20 bit DAC drives can be tee'ed to the new DAC via a selection matrix. The first 8 DAC channels are being read back by an ADC in h1iscex, by the h1pemex model.

h1susex was moved from the production RCG 5.1.4 boot server (h1vmboot1) to the new RCG 5.3.0 boot server (h1vmboot0).

h1susauxex was powered down during this install.

The h1iopsusex model was modified to add the new DAC. h1susetmx was modified to drive the new DAC with any combination of the four production DACs it is driving (two are 18bit, two are 20bit).

A DAQ restart was required. Due to a DAQ configuration issue the 0-leg was offline for about an hour.

WP11937 New Cal models

Louis, Joe, Dave:

New h1cal[cs, ex, ey] were installed. A DAQ restart was needed.

WP11944 New Seiproc model

Jim, Dave:

A new h1seiproc model was installed. A DAQ restart was required.

DAQ Restart

Jonathan, Erik, Dave:

As mentioned above this was a messy restart because the new boot server rewrote the DAQ master file to only include the h1susex system. Our brief h1pemmx test yesterday did not pick this up since we did not do a DAQ restart.

The issue was found on the 0-leg, so did not impact the control room while we identified the problem as resolved it. The 1-leg restart went ahead with no issues.

After the DAQ was back up and running, we noticed that FW0 frame write times were sometimes 10-20 seconds longer than FW1's, and sometimes about the same. This situation persisted for about an hour and then resolved itself.

3IFO Dewpoint Sensor for HAM3

Bubba, Fil, Dave:

Fil investigated the HAM3 3IFO dewpoint sensor. It looks like a failed sensor.

Roof Camera

Fil, Marc, Dave:

Fil and Marc went onto the roof and restored the camera which attaches to the viewing platform. This camera is now working again.

h1sush2a DAC high quarter error

Erik, EJ, Dave:

We discovered that all the h1sush2a DACs had been in high-quarter-fifo error since 9th April 2024 (last day of O4 break). This frontend controls MC1, MC3, PRM, PR3.

We restarted the models and the DACs are now good.

See Erik's alog for details.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 10:34, Wednesday 26 June 2024 (78675)
h1susex IO Chassis running with Beckhoff Timing Error

The Beckhoff timing system is reporting an error at the EX station following the new DAC install yesterday, which required a timing card with an updated firmware version. This error is actually just an informational message acknowlegding the firmware version difference on the timing card attached to the fourth port (port3) of the EX timing fanout.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 10:30, Wednesday 26 June 2024 (78672)
CDS Overview Shows Front Ends Built With Other RCG

While h1susex is running on RCG5.3.0 I have modified the CDS overview to show this so we don't forget that these models need a special build.

I've used the sliver between the filter-status and the ipc-status to show this.

Images attached to this report
H1 General
ryan.crouch@LIGO.ORG - posted 10:00, Wednesday 26 June 2024 - last comment - 10:33, Wednesday 26 June 2024(78669)
Morning IA issues

This morning it seems XARM was having some issues related to the PLL (seen yesterday in alog78660) beatnote. This caused the XARM to keep jumping from unlocked -> increase_flashes -> fault, as seen in the log. After a bit it was able to fix itself and the GREEN_ARMS section of IA finished in about ~30 minutes, the rest of IA went fine and only took 15 minutes. The longer GREEN_ARMS time caused the H1_MANAGER IA timer of 40 minutes to expire and IA got stuck in INIT_ALIGN_FINISHED and SRC_ALIGN_OFFLOADED for ALIGN_IFO.

Images attached to this report
Comments related to this report
oli.patane@LIGO.ORG - 10:33, Wednesday 26 June 2024 (78674)

ALS_XARM was going into FAULT(state 14) every time INCREASE_FLASHES was tried due to issues with PLL, PDH, VCO, and the beat note strength. Trending some channels, it looks like the fault was corrected when the laser head crystal frequency went down and ALS-X_FIBR_DEMON_RFMON went back to above -10dB.

Images attached to this comment
H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 09:05, Wednesday 26 June 2024 - last comment - 10:15, Wednesday 26 June 2024(78666)
Lockloss

Lockloss @ 06/26 16:04 UTC unknown cause

Comments related to this report
oli.patane@LIGO.ORG - 10:15, Wednesday 26 June 2024 (78670)

17:14 Observing

 

H1 SQZ (DetChar, DetChar-Request)
camilla.compton@LIGO.ORG - posted 09:04, Thursday 20 June 2024 - last comment - 10:34, Wednesday 26 June 2024(78549)
SQZ Laser is Glitchy since May 20th, CLF ISS gltihcy since O4b start.

Vicky, Begum, Camilla: Vicky and Begum noted that the CLF ISS and SQZ laser is glitchy.

Vicky's plot shows CLF ISS glitches started with O4b, attached.

Timeline below shows SQZ laser glitches started May 20th and aren't related to TTFSS swaps. DetChar - Request : Do you see these gltiches in DARM since May 20th?

  • Pre-April 25: no glitches
  • 25 April:  TTFSS issues, Removed Chassis S2300258, Installed Chassis S2300259 (alog 77418); also caused SQZ rack glitch: 77424 / FRS 31061
  • 25 April - 7 May: no glitches apart from on Tuesday April 30th
  • 7 May: Reinstalled repaired TTFSS. Removed Chassis S2300259, Installed Chassis S2300258 (77688)
  • 7 May - May 20th: Glitches stay small
  • May 20th 22:00UTC (Monday): First glitch shown on detchar summary page /20240520/sqz/glitches/
    • Day shift summary: 77941 included PR2 spot move, but don't expect glitches could be  IFO alignment dependent.
  • Lots of glitches since May 20th.  These glitches aren't constant and seem to get better and worse on different days, in general got worse since May 20th.

Summary pages screenshots from: before glitches started, first glitch May 20th (see top left plot 22:00UTC), bad glitches since then.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 12:25, Monday 24 June 2024 (78626)

Missed point:

  • 9 May: TTFSS issues, Removed Chassis S2300258, Installed Chassis S2300259, 77734  later saw the issues were from fiber polarization not the chassis.
andrei.danilin@LIGO.ORG - 14:08, Monday 24 June 2024 (78627)

In addition to previous report, I must note that glitches started on May 9th and continued for several times even before to May 25th.
Glitches are usually accompanied by the increased noise in H1:SQZ-FIBR_EOMRMS_OUT_DQ and H1:SQZ-FIBR_MIXER_OUT_DQ channels.

Images attached to this comment
andrei.danilin@LIGO.ORG - 10:34, Wednesday 26 June 2024 (78673)

Andrei, Camilla

Camilla swapped the TTFSS fiber box 78641 on June 25th in hopes that this will resolve the glitches issue.

However, it made no difference: Figure (see from 20:40 UTC, as it is when TTFSS box was swapped).

Images attached to this comment