bubba.gateley@LIGO.ORG - posted 15:48, Tuesday 19 February 2013 (5528)
Apollo crew
Moved cleanrooms in south bay per request from Betsy with approval from Jodi. Started ICC at BSC 10, documented chamber, pictures, wraped support tubes, covered RGA per instruction from Kyle. Ran compressor to blow out cobwebs and ready to start brushing tomorrow. John and I glued measurement spheres for reference before and after removal of coupon on sample beamtube and started setting up for coupon cut with plasma cutter.
H1 SEI
jim.warner@LIGO.ORG - posted 15:47, Tuesday 19 February 2013 (5527)
HAM2 dummy payload removed

HughR, JimW, some Apollo

This afternoon, after Jodi and Cheryl did their in-chamber cleanliness assessment, we removed the dummy payload from the HAM2 optical table (6x 50lb masses and 3 10kg masses). No other components were touched, so there maybe other components to be removed from the table before PR's are installed.

X1 SUS
jeffrey.bartlett@LIGO.ORG - posted 12:10, Tuesday 19 February 2013 (5526)
Phase 1b M1 Transfer Functions for I1-MC2
   Attached are the plots for the M1 level transfer functions for MC2. This is the first of the India HSTS suspensions to be tested. The plots look good. While Stuart Aston and Jeff Kissel are reviewing these results, we will install the AOSEMs and prep MC2 for the power spectra tests.      
Non-image files attached to this report
H1 SUS
betsy.weaver@LIGO.ORG - posted 10:49, Tuesday 19 February 2013 (5525)
PR3- M2 AOSEM Brackets swapped

Late last week, Deepak and I precariously swapped the problematic and AOSEM brackets described in my previous alog:

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=5499

 

I use the word precarious because the operation meant that tools, small fasteners, and hands were wedged inside of the suspension above the optic and extremely close to fragile wires in order to replace the 4 brackets.  This did not make me happy.  See some pictures below, but the collection is also posted  ResourceSpace: https://ligoimages.mit.edu/?r=23901

Images attached to this report
H1 SEI
hugo.paris@LIGO.ORG - posted 10:22, Tuesday 19 February 2013 (5524)
HAM3-ISI - Level 3 Controllers

HAM3-ISI level 3 controllers were designed on Jan 16th 2013. Controllers are shown in the first .pdf attahcement of this post, and saved in the SVN under: /seismic/HAM-ISI/H1/IMC_Test/Isolation_Filters/HAM3/

Those controllers were designed on in-air measurements. In-air VS In-Vacuum comparisons show that the major resonances we account for during ISO loops design are not affected by switching from in-air to in-vacuum.

Non-image files attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 16:56, Saturday 16 February 2013 (5522)
cdsfs0 and h1seih16

cdsfs0 was reset. I verified from the control room that I could recover this system "remotely" via the administration port. If it fails again before Tue I'll try to remotely recover it, but for now it appears to be a Saturday problem.

h1seih16 When I got to the control room at 15:30 I noticed that h1seih16 had been frozen from 13:15. I took it out of the Dolhin fabric and tried restarting the models, but no I/O cards are detected. I took a quick look at the IO Chassis and found it without power (front panel switch is ON, 24V power strip has +24V LED ON). It looks like  a power supply issue so I'm leaving this till Tuesday. I'm running the models to "green up" the EDCU, but no useful data is coming from HEPI HAM1.

H1 CDS
david.barker@LIGO.ORG - posted 11:54, Saturday 16 February 2013 (5521)
/ligo file system is in read-only mode

For the second saturday in a row the /ligo file system at LHO has issued a scsi error and switched to read-only mode. I'll drive to the site later this afternoon to reboot it. We will work on replacing the scsi controller card next week to see if we can fix this problem.

The error occurred at 08:06 today, at at 00:05 last sat.
H1 SEI
hugh.radkins@LIGO.ORG - posted 07:49, Saturday 16 February 2013 (5520)
LHO LVEA HEPI Piping Valves Closed for leak checks
This morning all the valves that could be closed were closed to isolate the piping for tracking the very slow downward trend in the pressure.  Since Wednesday afternoon there has been a drop of 3psi.  This is way too much to be temperature related.  Hopefully it will just be a loose fitting; wish me luck!
LHO General
patrick.thomas@LIGO.ORG - posted 18:58, Friday 15 February 2013 (5519)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot requested from 5 PM Feb. 14 to 5 PM Feb 15. Also attached are plots of the modes to show when they were running/acquiring data.

Data was taken from h1nds0.
1440.0 minutes of trend displayed
Non-image files attached to this report
H1 SUS
arnaud.pele@LIGO.ORG - posted 17:18, Friday 15 February 2013 (5515)
PRM Phase 2b

Attached are power spectra of PRM for Phase 2b checking.

-Damping seems to be working looking at 2013-02-14_1500_H1SUSPRM_**_ALL_Spectra.pdf

-Comparison between PRM L1 Phase 2a (Jan 2013) X1 (Sept 2012) and H1 (Feb 2013) has been plotted for damping on and damping off

(allhstss_2013-02-14_Phase2b_H1PRM_ALL_Spectra_Doff.pdf and allhstss_2013-02-14_Phase2b_H1PRM_ALL_Spectra_Don.pdf )

**Frequencies of the main DOFs for M1, M2 and M3 are matching the model and L1 power spectras.

**An extra peak appears at ~5Hz on several curves from L1 (ex : allhstss_2013-02-14_Phase2b_H1PRM_ALL_Spectra_Doff.pdf --> M1_DAMP_L_IN1 on page 7). Noisier environment there ?

**The amplitude of some power spectra from H1 PRM is higher than the ones from L1 (ex : allhstss_2013-02-14_Phase2b_H1PRM_ALL_Spectra_Doff.pdf --> M1_DAMP_Y_IN1 on page 12), and most of them are higher at low frequencies.

A reason would be that the PRM was uncovered during measurements (figured out afterwards) and "wind" could have made it moving. Will run power spectra again to check this, now the cover is back on.
 

Non-image files attached to this report
LHO General
dale.ingram@LIGO.ORG - posted 16:44, Friday 15 February 2013 - last comment - 11:47, Tuesday 19 February 2013(5518)
Friday Summary
Comments related to this report
arnaud.pele@LIGO.ORG - 11:47, Tuesday 19 February 2013 (5523)

Ran new power spectra over the week end, to confirm why the low frequency amplitude was high on Thursday's PRM power spectra (2013-02-14). Now the suspension is covered again, the power spectra looks better. See one of the two first attached documents (allhstss_2013-02-15) comparing L1 PRM power spectra (Jan 2013) H1 PRM uncovered (Feb 14th 2013) and H1 PRM covered (Feb 15th 2013), the difference can be clearly seen.

**the data have been commited on the svn and can be found here :
/ligo/svncommon/SusSVN/sus/trunk/HSTS/Common/Data/allhstss_2013-02-15_Phase2b_H1PRM_ALL_Spectra_Doff.pdf
/ligo/svncommon/SusSVN/sus/trunk/HSTS/Common/Data/allhstss_2013-02-15_Phase2b_H1PRM_ALL_Spectra_Don.pdf

/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Results/SAGM{1,2 or 3}/2013-02-15_1700_H1SUSPRM_M{1,2 or 3}_ALL_Spectra.pdf

 

**Only the "good" data (=Feb 15th 2013) will be added to the plotallhsts_spectra.m script. Will commit the script with new data right after this log.
 

 

 


 

Non-image files attached to this comment
H1 PSL
michael.rodruck@LIGO.ORG - posted 16:06, Friday 15 February 2013 (5517)
PSL plots

Weekly trends. Next week we may need to increase the current on pump diodes 3 and 4 as they've dropped to 90% of their nominal value, and the output power of the 35W laser has dropped below 95% of its nominal value.

Images attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 15:40, Friday 15 February 2013 (5516)
Replaced PT343B gauge head @ X-mid (indicated value not yet calibrated)
Kyle, Gerardo 
Replaced PT343B gauge head -> The 1.5" metal angle valve (in series with the 1.5" O-ring valve) was found to be over torqued (closed) as its depth indicator was "off scale" combined with the observation that nominal applied torque resulted in no perceivable stem rotation -> We couldn't demonstrate that this valve's over torqued knife-edge seal leaked appreciably after replacing PT343B -> the rate of pressure rise indicated by PT343B when isolated from the BT and the pump cart (while rising through the 10-6 - 10-5 torr range) did not change noticeably when the O-ring side of the re-closed metal valve was vented versus when it was under vacuum 

We helium leak tested all joints of X1-9 prior to opening to the BT (baseline 1.5 x 10-9 torr*L/sec)  

Note: the indicated pressure value is not calibrated -> we will use neighboring gauges/history to adjust new gauge when time permits
H1 SUS
betsy.weaver@LIGO.ORG - posted 14:26, Friday 15 February 2013 - last comment - 14:36, Friday 15 February 2013(5513)
Particle Counter Plot from in-side BSC1 during last vent

During the last few days of vent activity in BSC1 late last month for the ITMy alignment, I parked the BSC1 particle counter inside the chamber with us.  Attached is a plot noting the events that the particle counter witness (thx, Justin!).  Things to say about the plot:

1) The particle counter has small spikes to ~15 counts/cub.ft during the quiet nighttime hours while no activity was taking place anywhere in the LVEA.  Note, we'll take a second monitor into the chamber during our next study such that we can confirm counts.

2) The highest counts seem to be during the soft cover activity.  My guess is that the settled particulate in the chamber gets quickly stirred up by the soft cover (or has even collected in the soft cover since that is the direction of "out") and gets re-tossed around in the chamber.

3) There is a longer than expected ringdown of particulate counted for the hours after people have left the chamber and the soft cover had been restored to the door.  It takes many hours for the particulate to settle back to the floor or horizontal surfaces after getting kicked up from traffic.

4) The overall counts of ~100 cnts/cu.ft are in line with what Robert reported in his in-chamber particulate measurement last month:

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=2071

 

For the record, I wiped the flooring in the chamber as I exited the chamber (not shown on the plot), pulling from the far side towards the door with many IPA saturated wipes.

Non-image files attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 14:36, Friday 15 February 2013 (5514)

Below are pictures of the witness plates and optics which I left in the chamber under the ITMy and in the beam tube section just +y of the BSC1 chamber.  There is also a picture us performing B&K Hammer testing of the ITMy which happens to show the placement of the particle counter (blac box with red dot on the elevated foil to the right of the ITMy).

Images attached to this comment
H1 SEI
hugh.radkins@LIGO.ORG - posted 11:44, Friday 15 February 2013 (5512)
WHAM2 ISI ***Locked***
Apollo got the doors off HAM2 and I followed with locking the ISI--no difficulties.
I took a few photos, mainly focused on the cabling coming off Stage0 to the electrical feedthrus.  Lot's of work to do in this department; the NW corner is pretty good but the others, not so much.  The last image is from the East (right) side and shows the PR mirror's dummy masses that will need to be removed.
Images attached to this report
H1 SEI
james.batch@LIGO.ORG - posted 10:05, Friday 15 February 2013 (5510)
Minor configuration changes on h1hpipumpl0
Minor administrative changes to hpi pump controller h1hpipumpctrll0, configured resolv.conf to allow other computers on network to be found by name, and started the ntp daemon to keep the time up to date.  Time was reset to current time (it was off by a few minutes).
H1 SEI
hugo.paris@LIGO.ORG - posted 15:51, Thursday 14 February 2013 - last comment - 11:23, Friday 15 February 2013(5497)
HAM3 Picture Survey

We pulled the soft cover off the North side of HAM3, and took a series of pictues in the chamber. 

These pictures will be used to asses the state of the ISI payload when we measured the ISI transfer functions for the Viton Pads Efficiency Investigation.

Images attached to this report
Non-image files attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 11:23, Friday 15 February 2013 (5511)

Cheryl, Hugo,

The attached .pdf file shows what was installed on HAM3-ISI as of yesterday, which is the configuration we ran the IMC test under. All the small optics mentionend in the top-level drawing are installed here

Non-image files attached to this comment
H1 SUS
mark.barton@LIGO.ORG - posted 15:00, Tuesday 12 February 2013 - last comment - 09:49, Friday 15 February 2013(5473)
PR3 TFs
Deepak and Bubba report they're done for the day, so commencing Matlab TFs on PR3.
Comments related to this report
mark.barton@LIGO.ORG - 07:14, Wednesday 13 February 2013 (5481)
Data taken, apparently successfully, plots pending.

Undamped: ^/trunk/HLTS/H1/PR3/SAGM1/Data/2013-02-12-1044746361_H1SUSPR3_M1_0p01to50Hz_tf.mat

Damped: ^/trunk/HLTS/H1/PR3/SAGM1/Data/2013-02-12-1044766428_H1SUSPR3_M1_0p01to50Hz_tf.mat
mark.barton@LIGO.ORG - 09:49, Friday 15 February 2013 (5509)
Plots finally - all good. This is a pass for Phase 2b TFs. Phase 2b spectra were waiting on some adjustments to the M3 OSEMs per alog 5499 (since fixed) and will be taken soon.
Non-image files attached to this comment