Displaying reports 83841-83860 of 89041.Go to page Start 4189 4190 4191 4192 4193 4194 4195 4196 4197 End
Reports until 12:55, Monday 04 February 2013
H1 CDS
david.barker@LIGO.ORG - posted 12:55, Monday 04 February 2013 (5361)
front end model and mx stream restarts

The INI change for the h1isietmy system precipitated a mini-restartfest. We restarted the models on h1seib2, h1susb6 an h1pemey (Dolphin related) and then restarted mx streams on h1susbstst, h1susauxb6 and h1susauxh2 (mx end point related).

H1 SEI
hugh.radkins@LIGO.ORG - posted 12:48, Monday 04 February 2013 (5360)
WHAM3 HEPI is now Unlocked---L4Cs being Leveled
Mind the signs--the HEPI is unlocked so the Blue Crossbeams are floating.  Do not step on anything if possible.  I should wrap this up today after which I will relock.
H1 SEI
greg.grabeel@LIGO.ORG - posted 11:31, Monday 04 February 2013 (5354)
HAM6 HEPI Install
The housings, crossbeams, and clamps have been installed on HAM6. It was a bit of a tight squeeze but with the help of Apollo we managed to get it done. Support tube positioning is almost complete, at which point I'll lock down the springs. One housing clamp needed a small modification, but is working well now.
Images attached to this report
H1 IOO
kiwamu.izumi@LIGO.ORG - posted 11:00, Monday 04 February 2013 (5359)
MC master screen updated

I have updated the IMC master screen, namely H1IOO-MC.adl, to the laest Livingston one this morning in order to enable links for some QPDs associated with the IMC.

H1 CDS
vincent.lhuillier@LIGO.ORG - posted 10:07, Monday 04 February 2013 (5358)
IPC error tripped watchdogs - H1SEIB6

The IOP watchdog of H1SEIB6 was tripped due to a IPC connection error between H1SEB6 and H1SUSB6 (cf attachment). An error rate of 10samples/s (64K model) will be allowed soon.

Images attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:28, Friday 01 February 2013 (5357)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot requested from 5 PM Jan. 30 to 5 PM Jan 31. Also attached are plots of the modes to show when they were running/acquiring data. Dust monitor 10 in the H1 PSL enclosure is still indicating a calibration failure.

Data taken from h1nds0.
T0=13-01-31-01-00-00; Length=86400 (s)
9780 seconds worth of data was unavailable on this server
1419.0 minutes of trend displayed
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:09, Friday 01 February 2013 (5356)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot requested from 5 PM Jan. 31 to 5 PM Feb. 1. Also attached are plots of the modes to show when they were running/acquiring data. Dust monitor 10 in the H1 PSL enclosure is still indicating a calibration failure.

Data taken from h1nds0.
T0=13-02-01-01-00-00; Length=86400 (s)
7740 seconds worth of data was unavailable on this server
1427.0 minutes of trend displayed
Non-image files attached to this report
H1 SEI
hugo.paris@LIGO.ORG - posted 17:55, Friday 01 February 2013 (5355)
IMC - ISI Isolation loops level 3 engaged

Design of isolation loops for HAM-ISIs go in 3 steps:
1) - Isolation loops level 1 :UGF=10Hz
2) - Isolation loops level 2: UGF=25Hz
3) - Isolation loops level 3: UGF=35Hz
The higher the step, the more sophisticated the control loops are.

Level 3 Isolation loops were designed, and installed, on HAM3-ISI a couple weeks ago. They were not used then.

The design of Level 3 isolation loops for HAM2-ISI was completed today. These control loops were installed and tested in cunjuction with their counterparts, running on HAM3-ISI:
- The IMC was locked right away (Gain=10dB, boost filter engaged) ~ 1.45pm PCT
- Spectra of the IMC length controls were taken, and compared with results obtained with the level 2 isolation loops (same blen filters used)

Improvements:
- Better performance in the 5Hz-10Hz range
- Better performance in low frequencies, below 200mHz

 

Notes:
- The IMC is still locked (5.41pm) and I am about to lower its loop gain to 0dB, just to make sure the servo does not damage anything if the IMC loses lock (requested by Giacomo & Cheryl)
- Ground motion is a bit favorable now, but not in the range of improvements, along the X-axis.
- Level 3 isolation loops will be left engaged over the weekend (see attached screenshots for Watchdog Values).

Images attached to this report
Non-image files attached to this report
LHO General
corey.gray@LIGO.ORG - posted 16:06, Friday 01 February 2013 (5353)
Ops Day Shift Summary

Giacamo/Cheryl worked out at IOT2R for the first part of the day with Laser Hazard (then after their work, we transitioned to Laser Safe).  This cleared up Hugo to do work on HAMISI & Barton to run measurements.

The Y Beam Manifold Spool was installed this morning.

Betsy worked on ITMy & Travis worked at Test Stand

EY BSC10 door was removed

Toppenish Middle School had an 8th Grade tour of the site (~100students)

H1 SUS
betsy.weaver@LIGO.ORG - posted 12:57, Friday 01 February 2013 (5352)
BSC1 closed out

This morning, I pulled the First Contact from ITMy-HR.  I then swapped in fresh witness plates for the ones I placed under the ITMy yesterday since I already saw particulate on them.  I did a final check over of the chamber and moved out all of my equipment.  The chamber is ready to close.

H1 SUS
betsy.weaver@LIGO.ORG - posted 12:48, Friday 01 February 2013 (5351)
BS Optic weight

For the record, here are the weights of the glass optic, compared to the weight of the dummy we used to tune the suspension:

BS optic = 14,251g

Dummy mass = 14,180g

 

So, the optic hangs a bit lower in the structure than the metal dummy mass - Travis confirms this with the position error of the top BOSEMs.  We will correct this if IAS measures that we need to.

 

Also, FYI - a BS shipping cake tin weighs = 22,538g

H1 AOS
jason.oberling@LIGO.ORG - posted 08:55, Friday 01 February 2013 (5348)
BSC1 ITMy Alignment (from Wednesday)

Fogot to post this Wednesday.  These are the pitch/yaw numbers after Travis locked the quad pitch adjustor set screws Wednesday morning.

H2 SEI
eric.allwine@LIGO.ORG - posted 07:55, Friday 01 February 2013 (5347)
BSC8 HEPI Actuator Removal
All BSC8 HEPI actuators have been removed.  These may be used for BSC3 after replacing the left(NW,SE) return vertical flexible pressure lines from 30" to 41".
H1 SUS
mark.barton@LIGO.ORG - posted 02:18, Friday 01 February 2013 - last comment - 07:53, Friday 01 February 2013(5345)
IM1 TF test
Attempting undamped TFs on IM1 using new script. Commissioning switch should go on and off automatically.
Comments related to this report
mark.barton@LIGO.ORG - 07:53, Friday 01 February 2013 (5346)
Done for now.
H1 IOO
cheryl.vorvick@LIGO.ORG - posted 20:13, Thursday 31 January 2013 - last comment - 09:28, Friday 01 February 2013(5344)
IMC power budget completed tonight:

- Giacomo, Cheryl

Alignment of the IMC, and IM3 and IM4, increased IFO REFL from 106mW earlier this week to 147mW today, giving 90% power coupled into the IMC.  In our first measurement, the IMC alignment had drifted away from optimum, and the the IFO REFL beam was clipped on the baffle in front of IM4.

Power budget: 

Location Power (mW) Time      
PSL before 210       alog #5100, 14 January 2013
PSL 178.3 1043721378   84.90% of the PSL "before"
IMC Refl Unlocked 178 1043720171   99.83% of the PSL beam
IMC Refl Unlocked PosB 2.11 1043719839   1.19% of the REFL beam
IMC Refl Locked (estimated) 15.18     8.53% of the unlocked beam
IMC Refl Locked PosB 0.18 1043719643   8.53% of the unlocked beam
IM1 Trans 0.072 1043719495      
IM4 Trans FWD 0.0216 1043718853      
IM4 Trans BWD 0.33 1043718853      
Park 147 1043717883   90.29% of the power coupled in the IMC

 

Comments related to this report
cheryl.vorvick@LIGO.ORG - 09:28, Friday 01 February 2013 (5349)
I should add that before this power budget was made I aligned the IMC and got IMC REFL down to 48 " counts"', and after the IMC broke lock and relocked IMC REFL was at 34 "counts"', which is a big improvement from our previous low of 50 "counts". To get this low IMC REFL I was down to aligning MC1, MC2, and MC3 at the level of +/-1 on the offsets that control the pitch and yaw of the mirrors, which means the alignment is close to optimum by human servo. The IMC stayed locked overnight, and temperature oscillations drove IMC REFL up and down, and throughout the night the low returned to 34 counts.
LHO General
corey.gray@LIGO.ORG - posted 16:29, Thursday 31 January 2013 (5334)
Day Summary
H1 SEI
vincent.lhuillier@LIGO.ORG - posted 16:16, Thursday 31 January 2013 (5343)
HEPI - ITMY - Sensors

The sensors used by HEPI-ITMY look functional. The attached plot shows the spectra of the L4Cs and the STS-2 (ground instrument).
STS-2 signals from HEPI-BSCs are broad-casted to the other chambers via a STS-2 distribution chassis (D0900351).
STS-2 signals seen by HEPI-HAM2 et HEPI-ITMY are identical (cf spectra).

Images attached to this report
H1 AOS
arnaud.pele@LIGO.ORG - posted 17:20, Wednesday 30 January 2013 - last comment - 15:04, Thursday 31 January 2013(5322)
B&K Hammer Measurement

Betsy W. and Arnaud P.

We took B&K hammer measurements on the QUAD installed on BSC1. The configuration during the measurement was BSC1 locked  QUAD unlocked and Vibration Absorbers ON.
The position of the accelerometer and the direction of axis were chosen from LLO measurements, cf picture attached to post 6022.
As for LLO, the hammer trigger threshold was set to 10N.

Two configurations of measurement have been recorded. For each of them, the 3 directions (X Y and Z) were saved from the accelerometer :
-excitation (hammer hit) along the X axis
-excitation (hammer hit) along the Y axis

The TF plots generated by Pulse Labshop have been directly exported to excel then pdf (enclosed). Each figure is showing phase (plot above) and magnitude (plot below) 

Comparing the results to the ones from LLO  (cf post 6022), the only particular thing to mention is the anti-resonnance at 25Hz for the two measurements. 
Otherwise, for the X impact-X response (first pdf, blue curve, 2nd plot), as for LLO we find peaks at 75Hz, 125Hz and 150Hz.
For the Y impact-X response (second pdf, blue curve,2nd plot), as for LLO we find a peak at 75Hz and an anti-resonnance at around 125Hz.

A bit of investigation will be needed before validating that step. 




 
 

Non-image files attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 21:28, Wednesday 30 January 2013 (5331)

Images attached to this comment
arnaud.pele@LIGO.ORG - 15:04, Thursday 31 January 2013 (5342)


		
		
Non-image files attached to this comment
Displaying reports 83841-83860 of 89041.Go to page Start 4189 4190 4191 4192 4193 4194 4195 4196 4197 End