Mark B. Per alog 5200, starting DTT TFs on ITMy. Will do M0 and R0 in parallel.


ITMy in BSC1 is now suspended. Mark is running a set of quick TFs to check for rubbing, and once deemed healthy, we are back to alignment for both SEI and SUS.
The H1 DAQ SATABOY disk raid system in the MSR failed at 01:27 local time Sunday morning (the Sunday gremlin?). From that time onwards h1fw1 has not been able to write frames. We will leave the system in its broken state for LDAS to do some forensics. This is the system that was upgraded to Sol11 on Thursday, we are investigating if that had anything to do with the failure.
Yesterday we measured again the MC2/MC3 crossover frequency. Again, tecnical problems prevented us from going all the way to the actual crossover frequency, but we were close enough to estimate confidently it to be close to 100 mHz. See attached plot.
Because of the peak right above 1 Hz and the observed instability if we try to increase the MC2 path gain, Matt designed a new filter to replace the elliptical one and roll off the gain before the offending peak (basically a LP filter at 1 Hz with at attenuation of at least 20 dB at 1.2 Hz, where the peak is). We then increased the MC2 loop gain by a factor to (0.005->0.01)
As a follow up to Hugh's post on Friday, I am posting some numbers to substantiate our claim that the BSC has not moved much from it's pre-move position. The attached DTT trends show the vertical CPS readouts from Jan 8th, after the chamber was vented, but prior to the initial ISI lock-up, up to our work on the 18th. Final cps numbers are kind of lost in the noise at the end, so final numbers are noted on the right side of each plot.
This weekend, I glued the second primary prism to the PR3 optic (the 3rd of its 4 prisms). I'll note here that the temperature of the room was higher than normal due to the fact that the original air bake oven was moved into the cleanroom and started for a 200 deg bake load over the weekend (Greg/TCS, see alog below). I used the Fluke probe and measured the RT to be 26.6 degC. Our optic bonds specify a 6 hour 34 degC air bake in the new custom oven, so we'll need to watch dor dualing air bake ovens in the future. I think we should start pulling work permits for this (and probably should have been in the past.)
The document contains a report on the recent measurements of hydrocarbons at the y end. The principal results are the attenuation of the hydrocarbon pressure with time and their significance for the future.
Test of an alog submission, reports of full disk problems.
Too many backups had accumulated. This has been rectified and a new backup routine will be implemented.
Test of an alog submission, reports of full disk problems.
[Paul, Cheryl, Giacomo]
Yesterday (Friday) evening the reading from WFS_A and WFS_B didn't quite seem to make sense, despite them having been aligned a few hours before by Cheryl. Paul and I went back to the IO table to do some more systematic testing. Bottom line is that quadrant 3 of WFS_A seems defective. It has a large offset and possibly a reduced sensitivity (although the fact that it has some sensitivity might be partially good news).
Note that this is the same unit that showed the anomalous heating described in entry 5131. The tests performed in that occasion were too superficial to notice the defect.
Although it might be initially possible to still use this sensor for some ASC test (by compensating for the offset and sensitivity in software), we will eventually need to remove WFS_A from the table and test it. To our knowledge, no spare is readily available.
This is the set of measurements we performed (values are in adc counts). We first (column 2) measured the dark current (note that for some reason the single quadrants have a sign inversion wrt the sum), then centered the beam on the WFS witht he IMC locked (column 3), then intentionally unlocked the IMC (column 4), then realigned the beam again (column 5) and finally re-locked the IMC (column 6). Note that the change in reading between IMC locked/unlocked in not necessarily due to beam wondering, as the shape of the beam itself is very different between the unlocked (mostly gaussian) and locked (mostly junk) states.
| Dark | IMC Locked, centered | IMC Unlocked | IMC Unlocked, centerd | IMC locked | |
| WFSA_SUM | -1215 | 500 | 9700 | 9350 | 750 |
| WFSA_Q1 | -0.5 | -450 | -1200 | -2750 | -650 |
| WFSA_Q2 | -3.75 | -450 | -6600 | -3000 | -225 |
| WFSA_Q3 | 1220 | 875 | -1200 | -1000 | 925 |
| WFSA_Q4 | -0.3 | -400 | -600 | -2600 | -900 |
| WFSB_SUM | 21 | 2000 | 11250 | 11250 | 2250 |
| WFSB_Q1 | -10.75 | -500 | -2750 | -3350 | -550 |
| WFSB_Q2 | -5.5 | -500 | -5050 | -2300 | -300 |
| WFSB_Q3 | -3 | -475 | -2650 | -3050 | -650 |
| WFSB_Q4 | -1.75 | -475 | -725 | -2350 | -750 |
I measured the noise spectra of both DC and RF channels with no light on the sensors (IOT1 enclosure closed and lightpipe shutter closed). The defective channel doesn't show any noticeable excess noise (although some other wierdness is going on in the RF channels of WFS_B).
Also, we found the test document of the "defective" WFS_A unit (LIGO-S1203264-v2) and realized that it shows a dark current of quadrant 3 much higher (~45 mA) than all the others quadrants of both this and its twin (~1 mA). This is not quiet the factor ~1000 difference wrt the other quadrants that we observe now, but I guess a small offset somewhere could easily change that ratio.
The question at this point is if this offset has been deemed acceptable at some point, and we should just consider the unit as "normal"...
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot from approximately 5 PM Jan. 17 to 5 PM Jan. 18. Also attached are plots of the modes to show when they were running/acquiring data. Dust monitor 10 in the H1 PSL enclosure is still indicating a calibration failure. The plots of the status gave a 'No data output' error, but I'm not sure what it means, since plots were generated and look reasonable.
The airbake oven in the LSB Optics Lab is baking 10 of the Nichrome wrapped glass formers. These will be baking over the weekend and are sort of precariously stacked. If you are in the Optics Lab and need to move the oven please contact me before jostling anything around.
Jim & I moved one stack of the Trim Mass & Damping Assemblies (D1003161) 5" +Y. Next we removed 0.75kg from each of two Assemblies to compensate for the strut that SUS has added to the Quad. These two Assemblies are located at A27,B48 & A36,B48 (D1001989 sht3.) At this point, Travis came into the chamber and removed the SUS protection pieces and the IAS CornerCube; he did not remove the Teflon Stops and the SUS remains locked. Next, Jim unlocked Stage2 and the CPS numbers settled down suggesting that when the Teflon Stops are removed, all corners will look pretty good. Corner 1 is a little low and removing those stops should lift that side of Stage2. Then Jim unlocked Stage1 and the CPS numbers look comfortably close to the pre/vent & ISI lock time at the start of the year. So next step is to back off the HEPI locks--they are very lightly engaged. Check the optical table level. Have IAS check X position, adjust as required with HEPI. Unlock the SUS and check pitch & yaw; adjust as required.
[Giacomo, Matt, Lisa, Cheryl, Keita, Kiwamu, Paul]
With the mode cleaner locking easily again, we were able to measure the open loop transfer function at the IMC servo board. Three such transfer functions are shown in the first attached plot here ('IMC_OLTFs.pdf), with these settings common to each transfer function:
And these settings specific to each transfer function:
Low gain 'lock acquisition' mode
High gain mode
High gain mode + notch filter
And now a bit of explanation:
From low gain mode to the high gain mode, we engaged the first common mode boost filter on the servo board, and ramped the gain up in steps, all the while looking at the OLTF up to maybe 500kHz. From this we expected that we should be able to push the UGF up quite a bit past 100kHz, but when we got past 24dB common gain, the loop became unstable (despite apparently having enough phase margin at the UGF. We looked out to a little higher frequency and saw the feature at 730kHz, which at 24dB was just poking above 0dB and apparently causing the instability. To cure this problem we tried implementing a notch + low pass filter at the servo input. This succeeded in squashing the 730kHz peak, but also lost us a few precious degrees of phase margin at the UGF. As a result, we still saw instability above 25dB common mode gain. The notch filter is no longer in the circuit, but will reside in Cheryl's office for a while in case someone finds it useful later on, or wants to modify it e.g. to make the notch Q higher. We discussed possible causes for the 730kHz feature - it may be related to the feature in the FSS OLTF measurement shown in entry 5093, though we couldn't be sure of the frequency axis in the attached plot. We have also reduced the common mode gain for now to 20dB, to keep the phase margin around 45deg. This leads to our new 'standard' locked high gain mode:
'Standard' High gain mode
Maybe once we get an autolocker script running we can have the above settings as the final state (for now).
The notch filter design, made by Matt, is attached, along with a picture of the box itself, in case anyone wants to use this in future and wonders what it looks like.
Mark B. Deepak centered the OSEMs on PRM and PR3 so I rechecked settings and got the damping working. I noticed that the WD thresholds had not been set nor the filters enabled, so I fixed that and redid the safe.snap files. Damped and undamped TFs for both will commence shortly and continue through the night. The respective Measurement Status indicators will light when a measurement is in progress.
Mark B. The PRM TFs went fine: Undamped: 2013-01-18-1042586592_H1SUSPRM_M1_0p01to50Hz_tf.mat Damped: 2013-01-18-1042606494_H1SUSPRM_M1_0p01to50Hz_tf.mat Plots look good. The PR3 TFs aborted due to a dumb typo of mine in the top-level script and were restarted at 11:01 am on 1/21.
The IMC lost lock tonight at about 4:00 AM local time. It is not clear why (no big drift in the control channels).
We had trouble recovering lock this morning, unitl we discovered that there were problems with the windows machine controlling the slow digital system.
After we reset the system, restore the working settings on the common mode board and readjusted the delay line value (I'm stressing this as the default setting after a reset of the system results in almost all the signal being in the Q quadrature, with a consequently unusable error signal... good to keep in mind!), we were able to reacquire lock very easily.
For future reference, the delay line pahse is set to 243.42 Deg (and can be read by the H1:IMC-REFL_A_PHASE_PHASEDEG channel)
Giacomo, Paul, Keita, Hugo, Matt, Lisa The IMC is locked and happy. The stability problems were due to the ISI, Hugo put it in a configuration which allowed us to recover a stable lock. We measured the open loop TF of the whole system, it was stable up to 30 kHz UGF. We also measured the cross-over VCO/MC2_M3: it is about 15 Hz (it can be stable as high as 100 Hz). The MC2_M3/M2 cross over is well below 1 Hz. A detailed entry with the measured transfer functions and gain settings will follow. We also centered the WFSs on IOT2 and found that a 90/10 beam splitter was used instead of a 50/50 in front of WFS_A, explaining the factor 10 power difference between the two WFSs. We leave the IMC locked for the night, and we should be able to start checking the WFSs signal path tomorrow.
We were trying to get a direct measurement of the M2/M3 cross over..we will try again tomorrow. Clean data starting at 1042513275 .
Paul has implemented a notch filter to push the UGF further up. He has measured the OLTF again and will post the new data in another entry.
The fast/slow path crossover frequency was measured by injecting an excitation signal before the MC2_M3 lock filters (H1:SUS-MC2_M3_LOCK_L_EXCMON) and taking the ratio of the signals immediatly before and after the injection point. With the settings of the relevant parameters specified below, the crossover is between 10 and 20 Hz (15 Hz? the shape of the TF is a bit funny there...). See attached plot.
Fast path gain (H1:IMC-REFL_SERVO_FASTGAIN): -2 dB
MC3 lock filters gain (H1:SUS-MC2_M3_LOCK_L_GAIN): -1000
MC3 lock filters enabled: FM5 (150:4) and FM8 (CLP100)
We used a similar setup to measure the MC3/MC2 crossover frequency, injecting an excitation signal before the MC2_M2 lock filters (H1:SUS-MC2_M2_LOCK_L_EXCMON). With the settings fo the relevant parameters specified below, the TF is well below unity at 1 Hz. See attached plot.
MC2 lock filters gain (H1:SUS-MC2_M2_LOCK_L_GAIN): 0.005
MC2 lock filters enabled: FM3 (0.1:1), FM4 (100:1) FM5 (0.01:0.1) and FM8 (ELP70)