Reports until 16:02, Wednesday 02 January 2013
LHO VE
kyle.ryan@LIGO.ORG - posted 16:02, Wednesday 02 January 2013 (5016)
HAM2-HAM3 pumpdown
1600 hrs. local 

2.1 x 10-6 torr @ turbo inlet -> Foreline @ 3.7 x 10-3 torr 

NOTE: temporary pump system used for this pump-down is ~1/4 the pump speed of the nominal MTP

*Venting adjacent volume today (BSC2....etc) did not communicate to gauge on HAM3, HAM3 annulus is vented* 
H1 SUS
james.batch@LIGO.ORG - posted 15:10, Wednesday 02 January 2013 (5015)
h1susbstst I/O chassis is dead
It appears the I/O Chassis for the h1susbstst computer (in the LVEA) has died.  I can not get it to power up, after disconnecting the power cord and reconnecting, turning on the power switch results in a momentary flash of LED's, then everything remains dark.
H1 SUS
james.batch@LIGO.ORG - posted 14:34, Wednesday 02 January 2013 (5014)
Restareted h1susim
Timing went bad on IOP model running on h1sush2b computer about 10:48 PST this morning.  Restarted h1susim and h1iopsush2b models to reset timing.  Checked with the usual suspects, but no one claims credit for this event.
H1 FMP
jodi.fauver@LIGO.ORG - posted 13:40, Wednesday 02 January 2013 (5013)
Y Arm and Y End status
The baling crew worked on clearing a second lane from the mid-station to the end. The road to the end is passable and both mid and end nitrogen storage tanks are accessible, with turn-around space for trucks. 

Bubba and I checked on the status of preparations for the vinyl installer, who is due on-site tomorrow. The floor in front of BSC6 is clear and ready. 
LHO VE
kyle.ryan@LIGO.ORG - posted 12:21, Monday 31 December 2012 (5012)
HAM2-HAM3 pumpdown
1200 hrs. local 

2.4 x 10-6 torr @ turbo inlet -> Foreline @ 3.9 x 10-3 torr 

Y-mid is now accessible -> Mechanical gauge @ tank 8514372 indicates 68" WC of LN2 

Tumbleweed crew working toward Y-end.  

1225 hrs. local -> Leaving site now
LHO VE
kyle.ryan@LIGO.ORG - posted 11:00, Saturday 29 December 2012 (5011)
HAM2-HAM3 pumpdown
1040 hrs. local 

2.7 x 10-6 torr @ turbo inlet -> Foreline @ 4.1 x 10-3 torr 

Domestic water storage tank @ 43", raw water storage tank > 60" 

BT roads still not passable -> tumbleweed crew working towards Y-mid 

1100 hrs. local -> Leaving site now
H1 CDS
david.barker@LIGO.ORG - posted 15:15, Friday 28 December 2012 (5010)
Rack relocation work complete

We have completed the removal of the two infrastructure racks in the H2 Building, with their contents now relocated in the MSR. All items went into the right side two MSR racks with the exception of:

the Qlogic switch which was moved to the DTS DAQ rack (previously the H2 DAQ rack)

the GC switch which was relocated into the DTS computer rack

the conlog machine which was relocated to the H1 DMT rack, this will become an H1 FE computer

The cdswiki machine was finally made to boot via a manual grub startup. This machine looks like it lost one of its LVM2 drives. Since it will be replaced with the new Debian box next week, we will hope it holds together until then.

The backup file server died again, we suspect a bad boot drive. It is scheduled for a reinstall on the second boot drive soon.

H1 CDS
david.barker@LIGO.ORG - posted 10:59, Friday 28 December 2012 (5009)
Rack relocation

Work continues on the rack relocation from the H2 Building to the MSR. Today we are fixing the cdswiki problems, moving the conlog machine into the H1 DMT rack, getting all services restarted and gutting the old H2 racks. Access to the DTS is down while we reconfigure the GC network in the H2 Building.

Attached is a picture of the two new MSR racks. They are the computer racks next the the two UPS racks.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 18:13, Thursday 27 December 2012 (5008)
CDS shutdown for server rack relocation

WP 3615, Dave B and Jim B

We shutdown all the servers in the H2 Building, starting at 9am today. All machines were re-racked in the MSR. The original network switches were moved along with the computers. All were connected to the Raritan Paragon KVM system.

We powered the machines on in order of importance: file and boot servers, admin servers, ifo servers, web and login servers.

All came back except for cdswiki, which appears to have a disk error. We will continue to work on this tomorrow, but for tonight there is no CDS web services: medm snapshots, web pages, work permit, cds wiki. If we cannot get cdswiki working tomorrow, we will put a temporary web server in place to serve the medm screen shots.

Staff with login account should be able to use their accounts now.

We check that the DAQ is acquiring the Vacuum controls and FMCS signals. All front ends were unaffected by this move.

All Ubuntu workstations in the control room needed a power cycle to get operational, we suspect DHCP issues.

I'll post a more detailed alog later.

LHO VE
kyle.ryan@LIGO.ORG - posted 13:11, Thursday 27 December 2012 - last comment - 13:12, Thursday 27 December 2012(5006)
HAM2-HAM3 pumpdown
1300 hrs. local 

3.3 x 10-6 torr @ turbo inlet -> foreline @ 4.4 x 10-3 torr
Comments related to this report
kyle.ryan@LIGO.ORG - 13:12, Thursday 27 December 2012 (5007)
Tumbleweed crew are working their way to Y-mid
H1 CDS
james.batch@LIGO.ORG - posted 11:32, Wednesday 26 December 2012 - last comment - 12:21, Wednesday 26 December 2012(5004)
h1boot restarted
The h1boot computer had a kernel panic Dec. 25 in the morning.  Rebooted at 11:19 PST Dec. 26. 
Comments related to this report
david.barker@LIGO.ORG - 12:21, Wednesday 26 December 2012 (5005)

logs suggest that h1boot became unresponsive at 01:55am Christmas Morning. 

LHO VE
john.worden@LIGO.ORG - posted 11:24, Monday 24 December 2012 - last comment - 11:27, Monday 24 December 2012(5002)
HAM3-HAM2 Pumpdown

HAM3 pressures as of Dec 24,  11:00 am

Cold Cathode - 5.6 e-6

Pirani - 5.6 e-3

 

Not a typo - both gauges read 5.6 but 3 decades apart.

Comments related to this report
john.worden@LIGO.ORG - 11:27, Monday 24 December 2012 (5003)

Tumbleweed baling continues.

The buildings are relatively clear now. One lane has been opened to XMID, the crew expects this lane to be done to XEND at the end of today.

Wednesday they will start on the YARM - we need access for LN2 and work planned for the YEND station in early January. They expect to work

through the holidays except for Dec 25.

LHO VE
kyle.ryan@LIGO.ORG - posted 13:45, Sunday 23 December 2012 (5001)
Energized CC gauge -> Gauge has yet to fire -> foreline 6.6 x 10-3 torr
1345 hrs. local -> Leaving site now
LHO VE
kyle.ryan@LIGO.ORG - posted 13:12, Sunday 23 December 2012 (5000)
1315 hrs. local -> Arriving to connect gauge and check on pump down
Expect to be here 30 mins.
LHO VE
kyle.ryan@LIGO.ORG - posted 11:18, Saturday 22 December 2012 (4999)
Switched HAM2-HAM3 pumping over to Turbo
1030 hrs. local -> HAM2-HAM3 @ 1.2 x 10-1 torr -> Relatively fast rough-down (scroll pump) due to 2" hose connection to 2.5" Vent/Purge valve as opposed to pumping through deenergized turbo pump (observed ultimate pressure of this particular scroll pump is 3 x 10-3 torr).  

Tumbleweed crew bailing near Y-arm penetration.  

1115 hrs local -> Leaving site now.
LHO VE
kyle.ryan@LIGO.ORG - posted 10:18, Saturday 22 December 2012 (4998)
1015 hrs. local -> Arriving to check on pumps -> Expect to be here 30 mins


			
			
H1 CDS
david.barker@LIGO.ORG - posted 17:17, Friday 21 December 2012 (4997)
rebuilt the backup server

The CDS backup disk server cdsfs1 crashed late last night and would not reboot today. We could not recover its boot disk, so we reinstalled Ubuntu 10.04LTS. The backup raid contents were preserved, so no need to rsync everything from /ligo and h1boot again. We are now re-installing the backup scripts and linking the tape backup system.

cdsfs1 had become very flakey lately, hopefully the rebuild will fix this.

Displaying reports 84121-84140 of 89002.Go to page Start 4203 4204 4205 4206 4207 4208 4209 4210 4211 End