corey.gray@LIGO.ORG - posted 12:02, Saturday 22 June 2024 (78590)
Saturday H1 Calibration Measurement Run (broadband headless + simulines)

Coordinated with LLO & Virgo a few times for this--3hrs & 15min (via TeamSpeak) before the Calibration.  And then about 2min before 1830utc (1130amPT), I spoke with each operator for a final reminder and then jumped into it.

NOTE:  So, I knew about this measurement (which I'm fairly new at still) because of our Operator Checksheet, where this measurement is listed as 1130amPT.  Also, on the LHO Control Room whiteboard, Saturday at 1130amPT there is a note.  For a more official document for O4b Calibration measurements, Jenne pointed me to the document (L2400036).  In this document the times for the calibration measurements are listed in Sec3.3.  In the Ops Wiki Calibration Instruction page, old times were listed (mainly the wednesday dates).  For O4b, we now run these calibrations on Thursdays at 830amPT & Saturdays at 1130amPT---I updated the wiki to show this.

Measurement NOTES:

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:22, Saturday 22 June 2024 (78591)
Sat CP1 Fill

Sat Jun 22 10:08:35 2024 INFO: Fill completed in 8min 32secs

 

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 07:36, Saturday 22 June 2024 - last comment - 08:26, Saturday 22 June 2024(78587)
Sat DAY Ops Transition

TITLE: 06/22 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
OUTGOING OPERATOR: Ibrahim
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 6mph Gusts, 4mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.06 μm/s
QUICK SUMMARY:

H1's been locked the last 7.5hrs and it's very quiet seismically.  Today's forecast high is around 98degF.

Nuc33's gwistat webpage needed to have the tab/webpage reloaded.

Comments related to this report
corey.gray@LIGO.ORG - 08:26, Saturday 22 June 2024 (78589)CAL

Oh and if all goes well, plan to run the Saturday Calibration in about 3hrs (at 1830utc).  Have sent post on mattermost and pokes via TeamSpeak to LLO & Virgo.

LHO General
ryan.short@LIGO.ORG - posted 01:00, Saturday 22 June 2024 (78586)
Ops Eve Shift Summary

TITLE: 06/22 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Observing at 155Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: One candidate event and three locklosses from observing this shift; one from an EQ and two that weren't obvious as to a cause. We had a few hours of downtime this shift just from locklosses in random places that I can't seem to explain (states like ALS, FIND_IR, DRMI, and one in TRANSITION_FROM_ETMX). Eventually H1 made it back to NLN and has been observing for about an hour.

LOG:

Start Time System Name Location Lazer_Haz Task Time End
18:36 SAF - LVEA YES LVEA is laser HAZARD 05:15
17:54 sqz karmeng opticslab yes.local sqz work 23:38
23:34 CAL Francisco PCal Lab n Packing up equipment 23:44
H1 General (Lockloss)
ryan.short@LIGO.ORG - posted 20:43, Friday 21 June 2024 - last comment - 00:07, Saturday 22 June 2024(78583)
Lockloss @ 03:22 UTC

Lockloss @ 03:22 UTC - link to lockloss tool

No obvious cause; ground motion was calm at the time.

Comments related to this report
ryan.short@LIGO.ORG - 22:22, Friday 21 June 2024 (78584)Lockloss

H1 was back to observing at 05:19 UTC after having to do some work to lock DRMI, but as I type this H1 lost lock again (observing for one minute) at 05:20 UTC. No immediate cause for this lockloss.

ryan.short@LIGO.ORG - 00:07, Saturday 22 June 2024 (78585)

H1 again back to observing as of 07:06 UTC

H1 General (Lockloss, SEI)
ryan.short@LIGO.ORG - posted 18:42, Friday 21 June 2024 - last comment - 20:23, Friday 21 June 2024(78581)
Lockloss @ 01:17 UTC

Lockloss @ 01:17 UTC - link to lockloss tool

Looks like this was some kind of ground motion according to Picket Fence and the 30-100mHz BLRMS, possibly a M5.1 earthquake from the Philippines, but there was no alert from Seismon or a transition to EQ mode. Unsure why we would be so sensitive to ground motion this weak.

H1 is already relocking automatically up to ENGAGE_ASC after going through PRMI.

Comments related to this report
ryan.short@LIGO.ORG - 20:23, Friday 21 June 2024 (78582)

H1 back to observing as of 02:15 UTC. Fully automated relock.

H1 SQZ
naoki.aritomi@LIGO.ORG - posted 16:26, Friday 21 June 2024 (78579)
FC backscatter projection

For FC backscatter projection, I excited the FC length signal. I basically followed the LLO's FC backscatter estimation in 65120.

The excitation result is shown in the first attachment. The FC length is excited between 4 Hz and 400 Hz and the DARM excess noise is seen between 20 Hz and 200 Hz. In the plot, the FC length signal is not calibrated and the DARM is calibrated to displacement. Note that there is no coherence between the excited FC length signal and excited DARM so this is not a linear coupling.

The FC backscatter noise is estimated using the following formula.

DARM_FC_backscatter = FCL_no_exc * sqrt(DARM_exc^2 - DARM_no_exc^2)/sqrt(FCL_exc^2 - FCL_no_exc^2)

The projection is shown in the second attachment. The projected FC backscatter is below DARM by a factor of more than 40.

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 16:25, Friday 21 June 2024 (78566)
Fri Ops DAY Shift Summary

TITLE: 06/21 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: RyanS
SHIFT SUMMARY:

H1 had a fairly straightforward time.  Needed an alignment to get it back to NLN both times.  Highlight of the afternoon was (3) gravitational wave candidates in less than 3hrs!
LOG:

H1 CDS
erik.vonreis@LIGO.ORG - posted 16:13, Friday 21 June 2024 (78578)
Filter Cavity Spectrogram script installed and running

[Andrei, Erik]

Andrei's script to create a spectrogram of these channels

 

H1:IOP-LSC0_MADC5_TP_CH8

H1:SQZ-FC_LSC_DOF2_OUT_DQ

 

Every ten minutes is now running. 

 

The script and its outputs are in /ligo/gitcommon/FC

Output is retained for 28 days.

 

The script is running on cdsvmscript1.

 

To turn it off, log in as root, then run

systemctl stop filter_cavity_spectrogram

systemctl disable filter_cavity_spectrogram

 

To turn it back on,

systemctl start filter_cavity_spectrogram

systemctl enable filter_cavity_spectrogram

LHO General
ryan.short@LIGO.ORG - posted 16:05, Friday 21 June 2024 (78577)
Ops Eve Shift Start

TITLE: 06/21 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Observing at 150Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 14mph Gusts, 9mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.05 μm/s
QUICK SUMMARY: H1 has been locked and observing for just over 5 hours.

X1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 14:12, Friday 21 June 2024 - last comment - 14:09, Thursday 27 June 2024(78574)
Status update: A+ HRTS assembly and characterization work for O5

Ryan C, M Robinson, R Kumar

Given below is the summary of work done in the triples lab in the last two months regarding assembly of A+ HRTS suspension for O5 (refer to alog 76635 which gives the details about the first assembly in March 2024- assembly s/n 02). We have assembled four new suspensions (assembly s/n 03, 08, 01, 11), which brings the total number of assembled (with BOSEMs) and characterized suspension in the lab to five. All five assembly till now has been for the FREESTANDING version (only the base differs- which is as per D1900287).

In this round of assembly and testing procedure of HRTS we have made two new improvements as listed below,

1. Class B PEEK wire install tool (top mass to PUM - as shown in the picture attached) - This new PEEK part has been designed by the RAL team after we had wire breaking issues in the first round of assembly. Using this new tool we can safely and quickly install the wires between top mass and PUM outside the cage on the optical bench.

2. Vibration Isolation set up as shown in view01 and view02 - While running transfer function measurements, the HRTS suspension was strongly coupling-in with the lab/building environment (ground vibrations, doors, HVAC etc). To partially isolate the SUS, we now have an optical bench (12in by 18in, Thorlabs Nexus Breadboard) sitting on a 1inch thick viton pads (placed at the four corners of the bench). Also, Chris fabricated a hard top transparent cover for us to protect against the turbulent air flow in the lab.

Cage S/N 03 (April 2024)

Suspended masses (as per specifications):-

Top Mass = 749gm, Penultimate mass = 803gm, Dummy optic = 300gm

BOSEM S/N       OLC     offsets (-OLC/2) Gain (30,000/OLC)
S1900810 30629 15314.5 0.979464
S1900795 31353 15676.5 0.956846
S1900754 29884 14942 1.003882
S1900809 24739 12369.5 1.21266
S1900782 23231 11615.5 1.291378
S1900626 30032 15016 0.998934

Transfer function measurements for HRTS assembly S/N 03 is attached here.

Cage S/N 08 (April 2024)

Suspended masses (as per specifications):-

Top Mass = 755gm, Penultimate mass = 803gm, Dummy optic = 301gm

BOSEM S/N       OLC     offsets (-OLC/2) Gain (30,000/OLC)
S1900701 30772 15386 0.974912
S1900716 31514 15757 0.951958
S1900713 31407 15703.5 0.955201
S1900705 23915 11957.5 1.254443
S1900700 26432 13216 1.134988
S1900712 31165 15582.5 0.962618

Transfer function measurements for HRTS assembly S/N 08 is attached here.

Cage S/N 01 (May 2024)

Suspended masses (as per specifications):-

Top Mass = 752gm, Penultimate mass = 804gm, Dummy optic = 300gm

BOSEM S/N       OLC     offsets (-OLC/2) Gain (30,000/OLC)
S1900646 28515 14257.5 1.052078
S1900705 30408 15204 0.986582
S1900612 32048 16024 0.936096
S1900653 24963 12481.5 1.201779
S1900669 23010 11505 1.303781
S1900655 32286 16143 0.929195

Transfer function measurements for HRTS assembly S/N 01 is attached here.

Cage S/N 11 (May 2024)

Suspended masses (as per specifications):-

Top Mass = 750gm, Penultimate mass = 803gm, Dummy optic = 301gm

BOSEM S/N       OLC     offsets (-OLC/2) Gain (30,000/OLC)
S1900645 25810 12905 1.16234
S1900649 29934 14967 1.002205
S1900683 31808 15904 0.943159
S1900629 27963 13981.5 1.072846
S1900689 23763 11881.5 1.262467
S1900634 28063 14031.5 1.069023

Transfer function measurements for HRTS assembly S/N 11 is currently under processing and the latest plots will be attached soon.

Conclusions: - The transfer function measurements ties-up nicely to the model, however we do see some low frequency coupling and unwanted peaks. The cross coupling and unwanted peaks are due to environmental noise which is difficult to fully isolate in the lab.

I will also post a plot comparing the transfer function measurement results for all five suspension that we have tested.

Images attached to this report
Non-image files attached to this report
Comments related to this report
rahul.kumar@LIGO.ORG - 14:09, Thursday 27 June 2024 (78706)SUS

Attached below are the transfer function measurement results for Freestanding suspension SN_11. I see some strong cross coupling in Vertical dof, possible combing from R dof.

Non-image files attached to this comment
H1 ISC
sheila.dwyer@LIGO.ORG - posted 11:02, Friday 21 June 2024 - last comment - 14:07, Friday 21 June 2024(78573)
script to heat up OM2 early Monday morning

I've set up a script to start heating up om2 TSAMS at 5:30 on Monday morning, so that it will be thermalized in time for our 8:30 pacific commissoning time. 

The script is at /ligo/gitcommon/labutils/beam_spot_raster/om2_stepper.py

It is running on cdsws39:

sheila.dwyer@cdsws39:/ligo/gitcommon/labutils/beam_spot_raster$ tconvert 1403267418 -l
Jun 24 2024 05:30:00 PDT
sheila.dwyer@cdsws39:/ligo/gitcommon/labutils/beam_spot_raster$ python om2_stepper.py -s 1403267418
Waiting for start time...

 

Comments related to this report
camilla.compton@LIGO.ORG - 14:07, Friday 21 June 2024 (78576)

We put this into a tmux session, this should mean that the command completes on even if the terminal is closed or computer logged out.

  • Set-up using 'tmux new-session' and then type command by usual. "Detach" from the session using CTRL-B then D.
  • To check on it, use command 'tmux attach'. "Detach" from the session using CTRL-B then D.
LHO VE
david.barker@LIGO.ORG - posted 10:28, Friday 21 June 2024 (78572)
Fri CP1 Fill

Fri Jun 21 10:08:00 2024 INFO: Fill completed in 7min 57secs

Gerardo confirmed a good fill curbside.

Images attached to this report
H1 SUS
corey.gray@LIGO.ORG - posted 09:05, Friday 21 June 2024 - last comment - 11:35, Friday 21 June 2024(78568)
Back To Observing, ACCEPTED an ETMX L2L Drive Align Gain

Had an SDF Diff for "ETMX_L3_DRIVEALIGN_L2L_GAIN"  (now 187.3792660000, was 187.3792260000); looks like this change is from work yesterday (alog 78555, and also screenshot).  ACCEPTED new gain.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 11:35, Friday 21 June 2024 (78575)

OK, Sheila said it was a type in guardian for this, so reverted back to the original gain value (screenshot of what I ACCEPTED...after Sheila updated guardian).  This was for the current lock.

Images attached to this comment
H1 CDS
david.barker@LIGO.ORG - posted 16:56, Tuesday 11 June 2024 - last comment - 16:56, Friday 21 June 2024(78378)
CDS Maintenance Summary: Tuesday 11th June 2024

WP11914, WP11918 Install ADC in h1iscex for h1pemex readout

Fil, Marc, Erik, Jonathan, Dave

In preparation for testing the new LIGO DAC card in h1susex, an ADC was installed in h1iscex which will read the new DAC's signals.

This ADC belongs to PEM, it was purchased to expand the number of accelerometers.

The ADC, its ribbon cable and interface card were installed in the h1iscex IO Chassis (see drawing). A PEM AA-Chassis was installed and connected to the ADC.

Two models were changed:

h1iopiscex: add 5th ADC

h1pemmx: readout the 5th ADC, route all 32 channels into filter modules with the names H1:PEM-EX_ADC_4_CHAN_n where n=0-31

DAQ restart was needed.

Add WAP channels to DAQ

Erik, Dave:

We took the DAQ restart as an opportunity to use the latest H1EPICS_WAP.ini which adds the missing corner station WAPs. EDC and DAQ restart needed.

Add IRIG-B signals back to end station CAL models

Keita, Fil:

The CNS-II Clock GPS receivers independent IRIG-B signals were reattached to the h1isc[ex,ey] AA chassis.

DAQ Restart

Dave, Jonathan:

The DAQ was restarted for the above model and EDC changes. There were several issues:

gds0 needed a second restart

FW1 spontaneously restarted itself after 728 seconds.

 

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 10:35, Wednesday 12 June 2024 (78388)

Tue11Jun2024
LOC TIME HOSTNAME     MODEL/REBOOT
09:00:01 h1iscex      ***REBOOT***  <<< Add 5th ADC
09:01:42 h1iscex      h1iopiscex   <<< new model
09:01:55 h1iscex      h1pemex    <<< new model
09:02:08 h1iscex      h1iscex  
09:02:21 h1iscex      h1calex 
09:02:34 h1iscex      h1alsex 


09:11:04 h1daqdc0     [DAQ]  <<< 0-leg restart
09:11:15 h1daqfw0     [DAQ]   
09:11:15 h1daqtw0     [DAQ]  
09:11:16 h1daqnds0    [DAQ] 
09:11:24 h1daqgds0    [DAQ] 
09:12:07 h1daqgds0    [DAQ] <<< 2nd GDS0 restart


09:12:12 h1susauxb123 h1edc[DAQ]  <<< EDC for WAP channels


09:16:20 h1daqdc1     [DAQ]      <<< 1-leg restart
09:16:31 h1daqfw1     [DAQ]     
09:16:32 h1daqtw1     [DAQ]    
09:16:33 h1daqnds1    [DAQ]   
09:16:41 h1daqgds1    [DAQ]  
09:27:57 h1daqfw1     [DAQ] <<< Spontaneous FW1 restart
 

keita.kawabe@LIGO.ORG - 16:56, Friday 21 June 2024 (78580)

IRIB-B code was restored at gps=1402156961 for EX and 1402159619 for EY.

I checked H1:CAL-PCALX_IRIGB_DQ and H1:CAL-PCALX_IRIGB_DQ starting at 1402159619 for 20 seconds using /ligo/svncommon/CalSVN/aligocalibration/trunk/Common/Scripts/Timing/irig_check.sh and the IRIG-B code agreed with the timestamp of the data after the leapsecond correction (which the script automatically does).

H1 was running w/o independent IRIG-B from gps=1400946722 to 1402156961 for EX, from gps=1400947702 to 1402159619 for EY.

IRIG-B codes were confirmed good right before disconnection of the IRIG-B cables and right after the restoration.

The timing system behaved w/o any suspicious behavior during the IRIG-B outage, see the attached plot. Top: X and Y and timing error. 2nd from the top: Duotone zerocross check (not the full duotone fit) for iopiscex, ey, iopsusex and ey. 3rd from the top: Duotone zercross check for h1iopomc0. Bottom: h1iopiscex and ey DAC.

Glitch of the OMC duotone at day 7th (Tue June 04) should be Jeff's test during maintenance (alog 78238), and glitch at EX on day 14 is the rebood described in the parent alog of this.

During this period, we had 3 significant LVK GW public alerts, S240531bp, S240601aj and S240601co.

Images attached to this comment
Displaying reports 8401-8420 of 84707.Go to page Start 417 418 419 420 421 422 423 424 425 End