kyle.ryan@LIGO.ORG - posted 16:15, Wednesday 21 November 2012 (4759)
Isolated BSC6' annulus ion pump from rest of annulus plumbing @ ~1100? hrs local
Pump controller should have come on-scale by now if gas load was due to O-ring flanges (now isolated from pump) -> Swapped controller -> leaving pump valved-out -> leaving aux. cart pumping annulus (1.3 x 10-6 torr)
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 12:10, Wednesday 21 November 2012 (4756)
H1 SUS ETMY M0 Phase 3b Transfer Functions
I've taken long-overdue damped and undamped, Phase 3b (with BSC6 at vacuum), transfer functions H1 SUS ITMY's main (M0) chain (formerly H2 SUS ETMY). Attached are the results: 2012-11-19 data is damped, and 2012-11-20 undamped. No surprises -- all mechanics look great / as expected. In processing these measurements, I've made improvements to the QUAD analysis scripts (see details below), so please svn up the QUAD corner of your local copies of the SusSVN. These were taken in-between Vincent's commissioning of BSC6-ISI, so I didn't press my luck to try and get reaction R0 chain measurements. We'll get 'em eventually.


Notes: 
- The damped transfer functions use the "final" set of filters and gains that were tuned / used during the H2 OAT, which look to be a little bit too aggressive, but it's a totally "by feel," qualitative assessment. With the newly fixed damped QUAD model, I intend to slap these filters and gains in (instead of the old "legacy" filters and arbitrary from LASTI which are in there now), and predict the test mass displacement -- specifically how much arises from sensor noise re-injected into the SUS vs. residual seismic noise. Stay tuned!

- The data was taken with freshly minted H1 SUS ETMY DTT templates, which can be found here:

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGM0/Data/
2012-11-19_1840_H1SUSETMY_M0_Mono_L_WhiteNoise.xml
2012-11-19_1840_H1SUSETMY_M0_Mono_P_WhiteNoise.xml
2012-11-19_1840_H1SUSETMY_M0_Mono_R_WhiteNoise.xml
2012-11-19_1840_H1SUSETMY_M0_Mono_T_WhiteNoise.xml
2012-11-19_1840_H1SUSETMY_M0_Mono_V_WhiteNoise.xml
2012-11-19_1840_H1SUSETMY_M0_Mono_Y_WhiteNoise.xml

(The same template is used for both damped and undamped transfer functions, so the date is the only thing one should need to change.)

- I've made several improvements to 

${SusSVN}/sus/trunk/QUAD/Common/MatlabTools/
plotquad_dtttfs.m
plotquad_matlabtfs.m
plotallquad_dtttfs.m
 
(1) I've added a few lines at the end of all three scripts which removes the individual plot .pdfs after they've been merged into the ALL.pdfs. They're just clogging up the svn, and were never use them anyways. 
For the "raw measurement" processing scripts, I've
(2) In the interest of getting all the gains right for predicting the damping loop performance, and because we now know the calibrations of the sensor and actuator chains well from independent measurements, I've changed the way the scripts calibrate the data. Namely, I explicitly calculate the [(sensor ct/drive ct) / (m/N)] (or [(sensor ct/drive ct) / (m/N.m)], [(sensor ct/drive ct) / (rad/N)], [(sensor ct/drive ct) / (rad/N.m)] as need be), instead of using the empirically measured value of 60. The number turns out to be 55.0708 [(sensor ct/drive ct) / (rad/N.m)], only an 8% difference, but it also aids in the understanding of improvement (3).
(3) I've added a switch inside the calibration step which -- based on a new, user-input, boolean, variable meas.sensCalib -- determines whether the OSEMINF "to_um" filter has been left ON during the measurement or not. Here's the new lines:

        if meas.sensCalib
                          % <-Sensor->   <---------- Actuator Chain ---------->;
                          %    OSEM                    Coil Driver Coil/Magnet ;
                          % Sensitivity       DAC       TransCond. Force Coeff.; 
                          %   [m/um]      [drive ct/V]    [V/A]      [A/N]   = [(m/um) . (drive ct/N)];
            calibration = (( (1/1e6) ) * ( (2^18/20)*(1/0.009943)*(1/1.694) ))^-1;
        else
                          % <----------------- Sensor Chain ---------------->    <--------- Actuator Chain --------->; 
                          %     OSEM                     SatAmp                              Coil Driver Coil/Magnet ;
                          %  Sensitivity                TransImp.    ADC            DAC       TransCond. Force Coeff.; 
                          %   [mm/uA]    [m/mm]  [uA/A]   [A/V]   [V/sens ct]   [drive ct/V]    [V/A]      [A/N]   = [(m/sens ct) . (drive ct/N)];
            calibration = (( (0.7/76.29)*(1/1e3)*(1e6/1)*(1/240e3)*(40/2^16) ) * ( (2^18/20)*(1/0.009943)*(1/1.694) ))^-1;
        end

Where, for the sensor chain, I've used the calibration as (best) described in LLO aLOG 4291, and for the drive chain, I've used the calibration as (best) described in LHO aLOG 4563 (though the force coefficient is different because HSTSs use 10Dx5T [mm] magnets, and QUADs, BSFMs, and HLTSs use 10Dx10T [mm] magnets on their top stage; the coil driver trans conductance is different because QUADs use QUAD TOP drivers, where HSTSs use Triple TOP drivers). Or, if you like pictures / diagrams, see T1100378. 

In case you're worried, we don't have to go back and re-run all of the old data. It's only an 8% change in the calibration, which we know can be less than the mechanical/electronics gain variation between suspensions. I will say though, I re-ran a few older measurements just to test it out, and it does put the measurements right smack on the model now for some of them (nice!).
Non-image files attached to this report
H1 SEI
jim.warner@LIGO.ORG - posted 11:55, Wednesday 21 November 2012 (4757)
BSC1 HEPI and ISI install progress
GregG, MitchR, JimW

Following the initial float of HEPI and Doug's follow up optical survey yesterday, HEPI was adjusted to fix the level of the the optical table this morning. The adjustment was relatively problem free, and the ISI is now level to within .1mm and is within .1 mm of the required elevation, at 244.1mm on Doug's ruler (see post 4752). After HEPI was adjusted, I locked the feet down while Greg and Mitch dropped cables down and plugged CPSes in. Unfortunately, a cable on a vertical sensor broke during install, so we will have to replace it, before proceeding with floating the ISI. We should be able to finish up by COB today, allowing SUSsers to resume work on Monday.
LHO General
patrick.thomas@LIGO.ORG - posted 09:26, Wednesday 21 November 2012 (4755)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot from approximately 6 PM Nov. 19 to 6 PM Nov. 20. Also attached are plots of the modes to show when they were running/acquiring data.

The plots of counts for the LVEA are missing. There were errors trying to plot them. They were not running for a time yesterday, (the power was unplugged, they probably glitched, and I didn't check for a while to see if they had come back). When they were being rebooted the channels for the calibrated counts were '-nan'. The edcu probably can not record this.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 09:08, Wednesday 21 November 2012 (4743)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot from approximately 6 PM Nov. 18 to 6 PM Nov. 19. Also attached are plots of the modes to show when they were running/acquiring data.
Non-image files attached to this report
H1 IOO
cheryl.vorvick@LIGO.ORG - posted 00:54, Wednesday 21 November 2012 (4754)
Mode Cleaner alignment:
- Keita, Kiwamu, Cheryl


Mode Cleaner:
The beam is centered as it comes through MC1 and centered on MC2.  We were able to center the beam on MC3 using the alignment sliders on MC2.  The beam made it back around to MC1 and is separated from the input beam by about 1cm.  Then it was time to go home.

The alignment was made using irises placed on HAM2 and HAM3 according to the dimensions of alignment tools that Luke made.

One thing we ran into was that one OSEM on MC2 was basically railed, so the watchdog kept tripping.  When MC2 tripped, it moved mostly in yaw which suggests it might be bumping into an EQ stop.


Other work in HAM2:
The beam from the PSL had to be adjusted from inside the PSL, because the centering on the upper periscope mirror was off.  After centering on the upper periscope mirror, the periscope had to be rotated to align the beam to the lower periscope mirror.  The rotation was maybe 1-2 degrees.  The position and angle of AROM RH1 and ROM RH1 were adjusted.  The clamp on ROM RH1 was moved 180 degrees, after seeing that the screw in the clamp was at the far end of the slot, and after finding available space on the top level HAM2 layout drawing.
H1 SUS
gerardo.moreno@LIGO.ORG - posted 21:39, Tuesday 20 November 2012 (4753)
PR3-01

(Margot P, Gerardo M)

Both primary prisms were finally removed from PR3-01, the adventure started on Wednesday, 11/14/2012.  After roughly 32 hours of soaking (in acetone, a very rare commodity around LHO lately), both primary prisms are off.

The only secondary prism was removed on Thursday, within 9 hours of soaking.

PR3-01 is now ready for its prisms to be glued.

H1 AOS
douglas.cook@LIGO.ORG - posted 18:43, Tuesday 20 November 2012 (4752)
BSC1 level and elevation measurements
Transferred wall target 501 elevation to new location for better line of sight for the autolevel. I named it 501B
I mounted a scale vertical next to 501B (501B = -26.9mm below Z0 at BSC2, beam tube centerline) and centered the scales 300mm line with the new wall target horizontal line.
I set the autolevel zero on the vertical scale at 500mm (200mm above 501B)
Panning over to BSC2 to the elevation height gage, the scale mounted to the precision rod which Jim W. held against the ISI optical table surface, the autolevel zero read 244.0mm near to the south side of the table.
Note: the distance down from the ISI table requirement is 1661.7mm to the beam tube centerline. So height gage length = 1488.6mm [1244.6mm (49.0") + 244mm on scale = 1488.6mm] + 200 on wall target + -26.9 = 1661.7mm 

Results:

HEIGHT: AVERAGE FROM SCALE 243.45mm (244mm = PERFECT ELEVATION)REQUIREMENT +/- 1.0mm FOR BEAM CENTERLINE so the closer the better (<1.0mm ?)

LEVEL REQUIREMENTS: ACCURACY REQUIREMENT:+/- 100urads (0.1mm DIFFERENTIAL HEIGHT) 

SCALE READINGS:
SE CORNER: 243.0 RAISE UP 1.0mm 
SW CORNER: 243.0 RAISE UP 1.0mm
NE CORNER: 243.6 RAISE UP 0.4mm
NW CORNER: 244.2 LOWER DN 0.2mm
H2 DAQ
david.barker@LIGO.ORG - posted 17:54, Tuesday 20 November 2012 (4751)
Test of DAQ upgrade to solaris11 on H2 DAQ

WP#3574

Greg, Dan, Dave.

LDAS upgraded the QFS writer for the H2DAQ primary system (h2ldasgw0 machine) to Solaris11.0 this afternoon. I have just remounted this file system on h2fw0 and h2nds0. The h2fw0 is writing frames to the QFS file system.

A bad 2GB mem DIMM was found in h2ldasgw0, this was replaced with a spare. Also, one of the fibre channel cards is showing a fault and we are running on the second card.

H1 CDS
david.barker@LIGO.ORG - posted 17:40, Tuesday 20 November 2012 (4750)
BSC1 front end code started

WP#3571

The SUS and ISI models to support BSC1 install work were started today. These were non-standard installs due to the following constraints:

Both of these limitations are temporary. When we upgrade to RCG2.6 the IPC limit will be raised. Tomorrow I will receive more memory for the H1DAQ (most probably wont install till next Tuesday).

I created IOP models for the SUS and SEI BSC1 frontends (h1susb123 and h1seib1). These were copies of the H2 equivalents minus the Dolphin IPC.

I copied H1SUSETMY model to become H1SUSITMY. The appropriate DCUID/computer changes were made and all Dolphin IPC was removed.

I copied the H1ISIETMY model to become H1ISIITMY. Again DCUID was changed and Dolphin IPC was removed. We had some confusion about the ADC distribution between HEPI and ISI. The models we have been using give ISI the first three ADCs and HEPI the fourth. Drawings indicate the opposite, HEPI getting the first ADC and ISI the last three. We will work on resolving this with team SEI.

As stated earlier, no H1DAQ changes were made. None of the BSC1 channels are being recorded by the DAQ.

LHO VE
kyle.ryan@LIGO.ORG - posted 16:32, Tuesday 20 November 2012 (4749)
Installed 2.5" all-metal UHV valve @ H1 ouput MC vent/purge port


			
			
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 13:30, Tuesday 20 November 2012 - last comment - 15:01, Tuesday 20 November 2012(4745)
Taking (More) H1 SUS ETMY Transfer Frunctions
Remotely; will be finished by ~5:30p, regardless of whether I'm actually done or not!
Comments related to this report
jeffrey.kissel@LIGO.ORG - 15:01, Tuesday 20 November 2012 (4747)
Transfer functions complete, restored ETMY with damping ON.
H1 AOS
douglas.cook@LIGO.ORG - posted 12:25, Tuesday 20 November 2012 (4744)
BSC2 BS cartridge positions_LHO location vs LLO
(Doug, Jason)
We took some quick measurements of the BS on TS2 to determine its postion in order to help resolve the interference between the strut mounting and the trim masses locations verses those at LLO.
Distance;
We measured to H1 BS position in relation to TS2-18 monument back  sighting to TS2-25 monument.
The required distance is 3734.9mm +/-3.0mm from the TS2-18 monument to the AR side of the optic with the glass mass installed. however, the metal dummy mass was installed for this measurement.
Note: the glass mass is 60.0mm+/-.0.5 thick verses 57.09mm +/- 0.5mm. So to adjust for the difference the distance measurement is shorter by 1.46mm (60.0 - 57.09 = 2.91/2 =1.46mm).
Measured distance was total station EDM to corner cube = 3694mm; corner cube to BS AR face = 49.4mm=> 3743.4mm => - 1.46mm correction for the dummy mass = 3742.mm total = 7.04mm error (long)

Translation:
Total Station set over the TS2-18 monument total station pointing at 45deg, 6min, 17 sec (perpendicular to AR)
Measured angle to the left edge of structure frame = 41deg,29min, 53sec. (3deg 37min,24sec from centerline)
Measured angle to the right edge of structure frame =48deg, 42min,54sec (3deg 36min 37sec from centerline).
Note: for calculation purposes needing the distance to the structure face where the edge measurement were taken we added: 3694mm (TS - CC) + 10mm (reference plain to CC mnt) + 4.90mm (mount thickness) =3708.9mm
Results: tan[3.6067-3.6103]/2 * 3708.9 =-0.1mm (right) (requirement is +/- 1.0mm

The 7.04mm is not the whole story I don't think
We should revisit templates? Changes in rev number of templates? Same version used in LLO?
LHO General
patrick.thomas@LIGO.ORG - posted 09:18, Tuesday 20 November 2012 (4741)
dust monitor in OSB optics lab
Yesterday I swapped the dust monitor in the optics lab labeled 'N', which was intermittently giving calibration alarms, for the one labeled 'U'.
H1 SUS
travis.sadecki@LIGO.ORG - posted 09:16, Tuesday 20 November 2012 (4740)
MC2 status

First Contact has been removed from the previously troublesome HR side of the MC2 optic.  The optic has been released and is now fully suspended. 

LHO FMCS
kyle.ryan@LIGO.ORG - posted 16:19, Monday 19 November 2012 - last comment - 16:32, Monday 19 November 2012(4738)
High return water temp for Y-mid

Cheryl notified me of a high temp alarm for the Y-mid supply ~74F return ~78F -> I confirmed that the chilled water circulating pump was running and noted 20psi was indicated at the pump inlet.  There were no alarms on the chiller control panel and the the display showed "Auto" and "Local".  The compressor did not run while I was present.  I walked through the building and the temp seemed "normal" i.e., not noticeably warm.  

The ambient temp outside is unseasonably warm today.  Neither Ski nor John are here today and I am not privy on the current FMCS settings etc. so, I'll not jump to rock the boat unless the building temperature rises noticeably.
Comments related to this report
john.worden@LIGO.ORG - 16:32, Monday 19 November 2012 (4739)

I found that both YMID and XMID had their heaters set to one stage on (8ma) in manual control. In the recent past these were in auto but now I notice that XMID is responding incorrectly when placed in auto. For the time being I have turned off the heaters in both buildings (4ma). This should bring the temperatures down.

A few weeks ago the chilled water setpoints were adjusted for winter operation - this, along with the additional heat load of the heaters, should explain the high chilled water temperatures.

H1 SUS
travis.sadecki@LIGO.ORG - posted 16:12, Monday 19 November 2012 - last comment - 09:40, Tuesday 20 November 2012(4737)
MC2 First Contact removal

With SEI continuing work on BSC1, I had the afternoon free to get a jump start on HAM3 work that Cheryl will be doing tomorrow.  The optic was locked and (after swapping controllers on the nitrogen due to non-functionality), I began pulling First Contact.  The AR side of the optic came off with no problems.  However, moving to the HR side, I noticed as I began pulling the PEEK tab that it had not be FC'd all the way to the edge of the FC area (about 5mm from the edge in fact).  After pulling hard enough to rip a few strands of the PEEK with no success on pulling down the FC, I resorted to applying more FC to the tab such that it is connected at the edge.  I'll try again in the morning.  Current state: optic is locked, AR is naked, HR is drying.  Side note: Before beginning, I noticed that SEI had 'testing in progress' signs posted on the chamber.  After consulting with the operator (Cheryl), attempting to contact Hugo by phone, talking to Vincent, checking the aLog, and physically checking that the ISI was locked down myself, it was decided that the signs were false and that I could work in the chamber.  Apologies if I did interrupt any measurements.

Comments related to this report
hugo.paris@LIGO.ORG - 09:40, Tuesday 20 November 2012 (4742)

The signs do not necessarily mean that measurements are currently running.

They are here to remind that the ISI is in testing state which implies that:

- Things can be broken if someone steps on the ISI while it is unlocked
- If someone makes changes to the ISI without notifying the SEI team, SEI ends up spending time troubleshooting while changes are obvious to the one who performed them.
- If measurements are running they will be interrupted.
- No matter how small the changes made are, it is always an interruption in the commissioning process and time is needed to get back up.

Like Travis did, it is important to always check with the operator/SEI before touching the ISI. Please follow the checklists on the sign to make sure that it is safe to work on the ISI (e.i. ISI is locked, suspensions are damped, no measurement running, ...) and that you leave everything like it should be (ISI unlocked for testing, SUS damped, no tools on the ISI, covers inflated, no rubbing cable....).

It is important to always leave an aLog, even short, describing the state the ISI was found, and left in.

The sign and the aLogs will also be helpful to our visitors that are not necessarily aware of the state/needs of the platform.

H1 SUS
jeffrey.kissel@LIGO.ORG - posted 11:51, Monday 19 November 2012 - last comment - 15:04, Tuesday 20 November 2012(4730)
H1 SUS ETMY Infrastructure Completion
I have filled out H1 SUS ETMY's new infrastructure, including
(1) Filling in the ISI to SUS WIT and SUS to ISI OFFLOAD paths, installed as was described for H1 SUS PR2 in LHO aLOG 4553. Nothing new -- same exact filters -- just using the H2 SUS ETMY (yes, H2 -- the SUS hasn't moved yet) matrices from
/opt/rtcds/userapps/release/isc/common/projections/ISI2SUS_projection_file.mat

(2) Installing the OPTICALIGN alignment offset calibration gain, as described in LHO aLOG 4563. Here, for this and all QUADs, the gain is

OPTICALIGN GAIN [cts/urad] = ( DAC [V/ct] * Coil Driver [A/V] * Coil/Magnet [N/A] * HSTS M1 to M3 [rad/N.m] * 1e9 [nrad/rad] )^-1
                           = ( (20/2^18)  * 0.009943          * 1.694             * 0.033514 (for Pitch)    * 1e9            )^-1
                           = 0.023219 [cts/nrad] for Pitch

                           = ( (20/2^18)  * 0.009943          * 1.694             * 0.015055 (for Pitch)    * 1e9            )^-1
                           = 0.051689 [cts/nrad] for Yaw

Note that I've gone with nanoradians instead of microradians (as was done for PR2), because the alignment offsets needed to align (at least the H2OAT) were already quite large (~75% of the M0 BOSEM range), so calibrating this gain into microradians (or any gain larger than 1, really) would have saturated the DAC. This provides for annoying large EPICS values, (retaining the -3027 and +5405 [ct] offsets needed for the H2OAT, means that these offsets are 58562 and 232783 [nrad]), but I think we can deal. I still need to adjust the OPTICALIGN screen to account for this difference (make the sliders have bigger default range and step size, as well as changing the legend to match).

(3) With further quantitative assessment pending, I've installed Rana's 2k to 16k anti-imaging filter in the 

L3_ISCINF_P
L3_ISCINF_Y

filter banks, in order to filter any imaging noise that arises from the inter-process-communication between the ASC model (running at 2k) and the SUS model (running at 16k). I attach a bode plot of the filter as installed (again, identical to Rana's).
Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 11:56, Monday 19 November 2012 (4731)
As of this entry, I've updated and committed H1 SUS ETMY's safe.snap here,
${userapps}/sus/h1/burtfiles/etmy/h1susetmy_safe.snap

as well as saved and committed the updated foton filter here,
${userapps}/sus/h1/filterfiles/H1SUSETMY.txt.

For both, I've checked that they're obeying the new schema, in which 
/opt/rtcds/lho/h1/target/h1susetmy/h1susetmyepics/burt/safe.snap
and
/opt/rtcds/lho/h1/chans/H1SUSETMY.txt
are soft links to the above userapps locations.
jeffrey.kissel@LIGO.ORG - 14:30, Tuesday 20 November 2012 (4746)
S. Aston, J. Kissel

Stuart was double checking my work (hooray!) and found several problems with my implementations of the OPTICALIGN offsets and gains.

(1) There's a typo in the labelling of the calculation (I wrote "for Pitch" twice, when one should be Yaw). The corrected statement is 

"For this and all QUADs, the gain is

OPTICALIGN GAIN [cts/urad] = ( DAC [V/ct] * Coil Driver [A/V] * Coil/Magnet [N/A] * HSTS M1 to M3 [rad/N.m] * 1e9 [nrad/rad] )^-1
                           = ( (20/2^18)  * 0.009943          * 1.694             * 0.033514 (for Pitch)    * 1e9            )^-1
                           = 0.023219 [cts/nrad] for Pitch

                           = ( (20/2^18)  * 0.009943          * 1.694             * 0.015055 (for Yaw)      * 1e9            )^-1
                           = 0.051689 [cts/nrad] for Yaw


(2) In my haste, I'd installed these gains exactly backwards (0.023 for YAW and 0.052 for Pitch). In fact, even further, I had calculated the offsets to-be-restored with the gains exactly flipped as well. Whoops! I've now corrected the gains, and changed the stored offsets to

Pitch: -3027 [ct] / 0.023219 [cts/nrad] => -132302 [nrad]  
Yaw:   +5405 [ct] / 0.051689 [cts/nrad] =>  104548 [nrad]


I'm Currently taking measurements, but I'll take a new safe.snap once I'm finished.
jeffrey.kissel@LIGO.ORG - 15:04, Tuesday 20 November 2012 (4748)
New safe.snap has been captured and committed to the userapps repo, as of version 3401:
/opt/rtcds/userapps/release/sus/h1/burtfiles/etmy/h1susetmy_safe.snap 