Today we moved WFS2 back to its original position and moved the second lens after the steering mirror. The combination without a second lens gave a beam too small. The new measured alignment matrix is
Sensing matrix for PIT was:
WFSA = +0.411*POS -5.483*ANG
WFSB = +1.269*POS - 3.783*ANG
Sensing matrix for YAW was:
WFSA = +0.036*POS + 1.962*ANG
WFSB =-0.431*POS + 3.265*ANG
The inverse matrices are:
PIT={{-0.7002, +1.0148}, {-0.2349, +0.0761}}
YAW={{+3.3830, -2.0329}, {+0.4476, +0.0373}}
Christina and crew cleaned at HAM1/2 twice today in preparation for door removal by the SEI crew. Hugh has five HAM door covers to use as needed. An additional six HAM door covers are on the shelf and at least six more are in the laundry queue. Bubba and crew removed the short-sided cleanroom from over HAM3 and placed it next to BSC8.
Douglas Daniel, Joe DeRenzis, Thomas Vo We finished assembling two D1101714, High Quality Wedged 6in Viewport assemblies (double optic). This is the first few articles of this particular assembly and pictures are attached, proof testing and leak testing to be done tomorrow (awaiting test parts from C&B). One of these assemblies is meant to be installed on HAM1 for the main PSL laser beam, we hope to be ready to connect the light tube this week.
Note the new jig designed and fabricated by Tyler for holding these viewports during inspection.
Modifications to the QUAD L1 (UIM) and L2 (PUM) stage CoilOutF filter banks were made via Foton to reflect the latest State Machine Diagrams updated last week. The changes were saved to the filter text files, and filter coefficients were loaded via the "*_GDS_TP" medm. The Foton filter text files were committed locally to the "cds_user_apps" Repository checked out under: '/opt/rtcds/userapps/release/sus/h2/filterfiles/H2SUS*TMY.txt'
For each of the four L2 (PUM) stage Coil Output Filter banks, the differences in the Foton text file are as follows: Previously (before 08/31/2012): ################################################################################ ### ITMY_L2_COILOUTF_LL ### ################################################################################ # DESIGN ITMY_L2_COILOUTF_LL 0 zpk([129.973],[13],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 1 zpk([99.9877],[1],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 2 zpk([5;19.9999],[0.5;249.809],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 5 zpk([13],[129.973],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 6 zpk([1],[99.9877],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 7 zpk([0.5;249.809],[5;19.9999],1,"n") ### ### ITMY_L2_COILOUTF_LL 0 21 1 0 0 SimAcqOffL2 0.1022381444281 -0.9950269485578308 0.0000000000000000 -0.9513581602053965 0.0000000000000000 ITMY_L2_COILOUTF_LL 1 21 1 0 0 SimAcqOnL2 0.01018979855460631 -0.9996165783185160 0.0000000000000000 -0.9623720057438665 0.0000000000000000 ITMY_L2_COILOUTF_LL 2 21 1 0 0 SimLPL2 1.198428225279573 -1.9083200482101859 0.9083375891754886 -1.9904437581736589 0.9904583948159983 ITMY_L2_COILOUTF_LL 5 21 1 0 0 AntiAcqOffL2 9.781085186882086 -0.9513581602053965 0.0000000000000000 -0.9950269485578308 0.0000000000000000 ITMY_L2_COILOUTF_LL 6 21 1 0 0 AntiAcqOnL2 98.13736695981576 -0.9623720057438665 0.0000000000000000 -0.9996165783185160 0.0000000000000000 ITMY_L2_COILOUTF_LL 7 21 1 0 0 AntiLPL2 0.8344262751043912 -1.9904437581736589 0.9904583948159983 -1.9083200482101859 0.9083375891754886 ################################################################################ Currently (as of 09/04/2012): ################################################################################ ### ITMY_L2_COILOUTF_LL ### ################################################################################ # DESIGN ITMY_L2_COILOUTF_LL 0 zpk([12],[110],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 1 zpk([1.35],[80.5],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 2 zpk([6;20],[0.5;250],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 5 zpk([110],[12],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 6 zpk([80.5],[1.35],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 7 zpk([0.5;250],[6;20],1,"n") ### ### ITMY_L2_COILOUTF_LL 0 21 1 0 0 SimAcqOffL2 8.999262730598492 -0.9586809127066087 0.0000000000000000 -0.9954086141798147 0.0000000000000000 ITMY_L2_COILOUTF_LL 1 21 1 0 0 SimAcqOnL2 58.74299131244113 -0.9695955355155262 0.0000000000000000 -0.9994824154540793 0.0000000000000000 ITMY_L2_COILOUTF_LL 2 21 1 0 0 SimLPL2 0.9996062717429675 -1.9082531975983987 0.9082707513809170 -1.9900610320883918 0.9900785927850526 ITMY_L2_COILOUTF_LL 5 21 1 0 0 AntiAcqOffL2 0.1111202139481815 -0.9954086141798147 0.0000000000000000 -0.9586809127066087 0.0000000000000000 ITMY_L2_COILOUTF_LL 6 21 1 0 0 AntiAcqOnL2 0.01702330742200748 -0.9994824154540793 0.0000000000000000 -0.9695955355155262 0.0000000000000000 ITMY_L2_COILOUTF_LL 7 21 1 0 0 AntiLPL2 1.000393883340034 -1.9900610320883918 0.9900785927850526 -1.9082531975983987 0.9082707513809170 ################################################################################
For each of the four L1 (UIM) stage Coil Output Filter banks, the differences in the Foton text file are as follows: Previously (before 08/31/2012): ################################################################################ ### ITMY_L1_COILOUTF_LL ### ################################################################################ # DESIGN ITMY_L1_COILOUTF_LL 0 zpk([],[],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 1 zpk([9.99999],[1],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 2 zpk([9.99999],[1],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 3 zpk([9.99999],[1],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 5 zpk([324.58],[59.9974],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 6 zpk([1],[9.99999],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 7 zpk([1],[9.99999],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 8 zpk([1],[9.99999],1,"n") ### ### ITMY_L1_COILOUTF_LL 0 21 1 0 0 Unknown 1 0.0000000000000000 0.0000000000000000 0.0000000000000000 0.0000000000000000 ITMY_L1_COILOUTF_LL 1 21 1 0 0 SimLP1L1 0.1001725184293824 -0.9996165783185160 0.0000000000000000 -0.9961723865238130 0.0000000000000000 ITMY_L1_COILOUTF_LL 2 21 1 0 0 SimLP2L1 0.1001725184293824 -0.9996165783185160 0.0000000000000000 -0.9961723865238130 0.0000000000000000 ITMY_L1_COILOUTF_LL 3 21 1 0 0 SimLP2L1 0.1001725184293824 -0.9996165783185160 0.0000000000000000 -0.9961723865238130 0.0000000000000000 ITMY_L1_COILOUTF_LL 5 21 1 0 0 AntiAcqL1 0.1938898668876849 -0.9772519830087036 0.0000000000000000 -0.8826755757975039 0.0000000000000000 ITMY_L1_COILOUTF_LL 6 21 1 0 0 AntiLP1L1 9.982777868412679 -0.9961723865238130 0.0000000000000000 -0.9996165783185160 0.0000000000000000 ITMY_L1_COILOUTF_LL 7 21 1 0 0 AntiLP2L1 9.982777868412679 -0.9961723865238130 0.0000000000000000 -0.9996165783185160 0.0000000000000000 ITMY_L1_COILOUTF_LL 8 21 1 0 0 AntiLP2L1 9.982777868412679 -0.9961723865238130 0.0000000000000000 -0.9996165783185160 0.0000000000000000 ################################################################################ Currently (as of 09/04/2012): ################################################################################ ### ITMY_L1_COILOUTF_LL ### ################################################################################ # DESIGN ITMY_L1_COILOUTF_LL 0 zpk([],[],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 1 zpk([10.5],[1],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 2 zpk([10.5],[1],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 3 zpk([10.5],[1],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 5 zpk([300],[50],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 6 zpk([1],[10.5],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 7 zpk([1],[10.5],1,"n") # DESIGN ITMY_L1_COILOUTF_LL 8 zpk([1],[10.5],1,"n") ### ### ITMY_L1_COILOUTF_LL 0 21 1 0 0 Unknown 1 0.0000000000000000 0.0000000000000000 0.0000000000000000 0.0000000000000000 ITMY_L1_COILOUTF_LL 1 21 1 0 0 SimLP1L1 0.09541142041015412 -0.9996165783185160 0.0000000000000000 -0.9959813858777531 0.0000000000000000 ITMY_L1_COILOUTF_LL 2 21 1 0 0 SimLP2L1 0.09541142041015412 -0.9996165783185160 0.0000000000000000 -0.9959813858777531 0.0000000000000000 ITMY_L1_COILOUTF_LL 3 21 1 0 0 SimLP2L1 0.09541142041015412 -0.9996165783185160 0.0000000000000000 -0.9959813858777531 0.0000000000000000 ITMY_L1_COILOUTF_LL 5 21 1 0 0 AntiAcqL1 0.1744034418878165 -0.9810067536768792 0.0000000000000000 -0.8910959203698616 0.0000000000000000 ITMY_L1_COILOUTF_LL 6 21 1 0 0 AntiLP1L1 10.48092561352933 -0.9959813858777531 0.0000000000000000 -0.9996165783185160 0.0000000000000000 ITMY_L1_COILOUTF_LL 7 21 1 0 0 AntiLP2L1 10.48092561352933 -0.9959813858777531 0.0000000000000000 -0.9996165783185160 0.0000000000000000 ITMY_L1_COILOUTF_LL 8 21 1 0 0 AntiLP2L1 10.48092561352933 -0.9959813858777531 0.0000000000000000 -0.9996165783185160 0.0000000000000000 ################################################################################
Looks good; thanks Garcia!
The ITMY & ETMY M0&R0 top stage CoilOutF filter modules matched the State Machine Diagram for the TOP Coil Driver before making modifications on the lower stage filter modules. All filter modules for every ITMY,ETMY M0&R0 CoilOutF filter modules are identical and contain the following digital filters: ################################################################################ ### ITMY_M0_COILOUTF_F1 ### ################################################################################ # DESIGN ITMY_M0_COILOUTF_F1 1 zpk([10],[1],1,"n") # DESIGN ITMY_M0_COILOUTF_F1 5 zpk([0.9],[31],1,"n") # DESIGN ITMY_M0_COILOUTF_F1 6 zpk([1],[10],1,"n") ### ### ITMY_M0_COILOUTF_F1 1 21 1 0 0 SimLPM0 0.1001724184483297 -0.9996165783185160 0.0000000000000000 -0.9961723827035119 0.0000000000000000 ITMY_M0_COILOUTF_F1 5 21 1 0 0 AntiAcqM0 34.24722014515512 -0.9881817593982465 0.0000000000000000 -0.9996549138717927 0.0000000000000000 ITMY_M0_COILOUTF_F1 6 21 1 0 0 AntiLPM0 9.98278783211981 -0.9961723827035119 0.0000000000000000 -0.9996165783185160 0.0000000000000000 ################################################################################
Found controller inoperative -> Replaced. Unit failed in July-will likely need aux. pump cart assistance to get going again. Note: GV16 alarm resulted as signal is now off-scale "high". Beam Tube gate valve annulus pressures are monitored by alarm handler
After noticing difficulties with untripping the QUAD watchdogs, I realized that a more sophisticated process is required to restore the QUAD status after a watchdog trip now that there are gigantic P and Y offsets on the TOP stage. Bare with me, it's complicated and convoluted because we didn't imagine this scenario while installing the infrastructure, but it's now on the "to-do" list to get it changed / more straight forward in the future.
For now, the process is as follows:
(1) Turn off the master switch.
(2) Untrip any relevant watchdogs.
(3) Change the gain in the P2P and Y2Y DriveAlign matrix filter banks to 0.00 (you can do this from the screen, or since you (currently) need a terminal open for the next step anyways, you can caput / ezcawrite it too). For example, if you're doing ITMY, that's
]$ caput H2:SUS-ITMY_M0_DRIVEALIGN_P2P_GAIN 0
]$ caput H2:SUS-ITMY_M0_DRIVEALIGN_Y2Y_GAIN 0
(4) Change the ramp time in the P2P and Y2Y DriveAlign matrix filter banks to 10 sec. (The link to the "full" screen is currently broken, so you'll have to do a "caput" or "ezcawrite" or whichever). For example, if you're doing ITMY, that's
]$ caput H2:SUS-ITMY_M0_DRIVEALIGN_P2P_TRAMP 10
]$ caput H2:SUS-ITMY_M0_DRIVEALIGN_Y2Y_TRAMP 10
(5) Turn ON the P and Y offsets to the desired value (if they're not on already); turn ON the damping loops (if they're not on already)
(6) Turn ON the MASTER SWITCH
(7) Change the gain of the P2P and Y2Y DriveAlign matrix filter banks back to one. Now that there's a ramp time in the signal chain, it'll slowly ramp up the offsets (and the P and Y damping loops), so the watchdogs won't trip.
--------------------------
The items on the "to do list" in order of difficultly/level of hackiness (from easiest / hackiest to most difficult / do-the-right-thingiest)
(1) Fix the DriveAlign Matrix sub-screen such that
(a) The "FULL" button works, and it opens the full filter bank (may just require an userapps svn up...)
(b) Add the TRAMP epics read/write to every element of the the upper level DriveAlign screen-
(2) Update the auto-damping script to include the above sophistication
(3) Offload what offsets you can to ISI and/or HEPI
(4) Make a model change such that the P and Y alignment offsets can be ramped (e.g. make the DCDRIVECAL gain a full filter bank, or add a ramp to the MASTER SWITCH, or something)
(5) Ask CDS to make the cdsEpicsIn block generate a TRAMP channel as well as a value channel on compile.
Garcia has volunteered to take on items (1) and (2) for now.
The auto-damping script for the H2 QUADs has been updated and committed to the "cds_user_apps" SVN repository. The updates include a gain-ramping of 10s for the P2P and Y2Y DriveAlign matrix elements. This will smoothly ramp the large DC M0 Pitch and Yaw offsets used for beam alignment. The script is committed to the SVN locally under: '/opt/rtcds/userapps/release/sus/common/scripts/' filenames: "sus_auto_damp_quad.txt", "sus_auto_UNdamp_quad.txt"
The previously-broken links in the "SUS_CUST_QUAD_M0_DRIVEALIGN.adl" file have been repaired.
The auto-generated filter module medms created by the RCG have had their filenames adjusted to a format resembling:
"H2SUSITMY_ITMY_M0_DRIVEALIGN_L2L.adl"
as opposed to a format previously used: "H2SUS_ITMY_M0_DRIVEALIGN_L2L.adl"
The generic files are located locally:
"/opt/rtcds/lho/h2/medm/h2susitmy/H2SUSITMY_ITMY_M0_DRIVEALIGN_*2*.adl"
The custom medm file for the DRIVEALIGN overview ("/opt/rtcds/userapps/trunk/sus/common/medm/quad/SUS_CUST_QUAD_M0_DRIVEALIGN.adl") was edited to point to the correct filenames.
The following table reports the frequency of all resonances as measured from TF and PSDs.
| IM1 | IM2 | IM3 | IM4 | |
|---|---|---|---|---|
| Yaw | 0.707 | 0.723 | 0.740 | 0.701 |
|
P/L 1 (mostly P) |
0.939 | 0.893 | 0.910 | 0.926 |
| P/L 2 (mostly L) | 1.041 | 1.006 | 1.021 | 1.035 |
| Trans | 0.996 | 0.996 | 0.996 | 0.996 |
| Bounce | 6.19 | 6.17 | 6.14 | 6.18 |
| Roll | 9.03 | 9.02 | 9.03 | 9.03 |
HAUX have no explicit fine adjustment to exactly match any of the resonances. However, Yaw is affected by the horizontal distance of the blade tips, can vary a bit during alignment is not usually checked agaist any reference. According to the model, 1 mm of difference in that distance translate in about 0.03 Hz of differece in Yaw resonance. If we have time, we can try playing with the blades to bring the yaw resonances closer...
Friday we re-installed ECD on all suspensions, adjusted the DC pitch of IM4 (that changes when you install ECDs) and run an OSEM calibration (using the same optical lever used for pitch balancing). We plan to do the same with the remaining suspensions Today, and have them ready for more (and possibly final) TF and PSDs tonight.
They were changed from the settings determined on the staging building test stand (first number) to:
H1:SUS-MC1_M1_OSEMINF_T1_OFFSET (-12980) -12987 GAIN (1.156) 1.155
H1:SUS-MC1_M1_OSEMINF_T2_OFFSET (-14639) -14642 GAIN (1.025) 1.024
H1:SUS-MC1_M1_OSEMINF_T3_OFFSET (-13929) -13821 GAIN (1.077) 1.085
H1:SUS-MC1_M1_OSEMINF_LF_OFFSET (-13879) -13761 GAIN (1.081) 1.090
H1:SUS-MC1_M1_OSEMINF_RT_OFFSET (-12265) -12104 GAIN (1.223) 1.240
H1:SUS-MC1_M1_OSEMINF_SD_OFFSET (-12570) -12666 GAIN (1.193) 1.184
I will run TFs next with the Top BOSEMs and then plug in the lower AOSEMs to set their offsets/gains.
Same known login problem... this wasn't me. It should have Betsy signature, I believe... :-)
Attached are plots of dust counts > .5 microns in particles per cubic foot.
I and Daniel measured the WFS sensing matrix by a very slow (0.1Hz) excitation. This is because POS signal is much smaller (it's naturally smaller for a given mirror angle, and WFS placement is unfortunately such that both WFSA and WFSB are more sensitive to ANG).
Originally before the beam path change, I think Bram and Arberto measured the sensing matrix by giving a large offset to either ANG or POS. I also briefly tried this, but in order to have anything for POS, the offset needed to be so huge that the beam almost comes inside one segment, so I decided that this is not a good method.
Anyway, at 0.1Hz I was able to have a very good coherence for both PIT and YAW, POS and ANG. (Data file is /ligo/home/controls/keita.kawabe/OAT_2012/WFS_sens_20120831.xml)
Sensing matrix for PIT was OK:
WFSA = -0.313*POS -5.056*ANG
WFSB = +0.620*POS - 3.930*ANG
Sensing matrix for YAW was hopeless:
WFSA = +0.139*POS + 2.754*ANG
WFSB=+0.091*POS + 3.751*ANG
Thing is, for YAW, the sign of POS signal for WFSA and WFSB are the same, and in order to subtract large ANG signal we also need to subtract a large portion of POS, making the POS signal even smaller.
We think that the problem is that the beam parameters on the table is different from what was assumed when designing the Gouy telescope. We might try something on Tuesday.
In the mean time, I inverted the sensing matrix and put them in the input matrix:
PIT = [-0.9004, 1.1580; -0.1420, -0.0717]
YAW = [14.5307, -11.2063; -0.3703, 0.5656]
We turned PIT on and it seems to be doing fine. Didn't bother to do YAW.
Checking the beam path for WFS2 we noticed that the beam is fairly astigmatic. This beam path employs a converging lens which produces a focus ahead of a second diverging lens in order to pick up Gouy phase. There is a clear focus vertically. However, it appears that the horizontal focus would be behind the second lens. The beam is also still too large on WFS2. The easiest solution would be to remove the second lens altogether and make sure there is a focus in the horizontal plane. The beam may be somewhat small, but WFS2 can be moved backwards to compensate.
(Keita K., Daniel S.) We changed the reflection path towards the wavefront sensors on the ALS table. Previously, they were picked up through the rejected return beam out of the Faraday isolator. Unfortunately, this Faraday isolator uses a wedged calcite as a polarizer which generates numerous ghost beams which were impossible to separate. Instead, we placed a 10% beamsplitter just before the first PZT mirror to pick-up a fraction of the return beam. We then duplicated the lens in the return path and steered the beam towards the wavefront sensor setup. The beam size on the two wavefront sensors was still too large, so we moved them as close to the last steering mirror as we could. Hopefully, this will yield a more reproducible sensing matrix.
This means that the injected beam power was reduced by 90%.
Everything in the Hartman sensor path including the REFL_B_PWR diode is receiving 90% smaller light.
Offset of the REFL_B_PWR was adjusted so that it becomes zero when the cavity was unlocked.
Faraday-rejected light see the 90% splitter twice, and PDH diode is the only thing that receives 0.9^2 = 81% smaller light.
Using the picomotors interferes with cavity locking and seems to introduce glitches which are clearly visible in the cavity power (see circled regions in the attachment).
[Alex, Cheryl, Deepak, Giacomo]
Yesterday morning we couldn't work to the suspensions due to drilling going on in the LVEA. We used the morning to debug the binary IO: now it is working properly and both the LP status and the Coil Output can be enabled and disabled from the front-end as expected.
In the afternoon we carried a large HxTS barrel from the staging building, changed the disposition of HAUX and cover all of them with the barrel, to ease the effect of air turbulence when taking transfer functions and PSDs. The suspensions were left covered and undamped (and no ECD)for the night. Note that we found the position of many of the OSEMs to be offset by couple hundreds um (or more), while they were initially set to be centered better (sometimes much better) than 100 um. Later investigation (this afternoon) suggested that this was due to a combination of:
- the table not being completely leveled (or flat), so that when you move the suspensions around the position of the optics slightly changes
- the frames being unevenly clamped (we only used 3 clamps yesterday as we didn't know where to find others...)
- the OSEM being not very well tightened, so some of them may have moved during handling of the cables and the suspensions to fit them under the barrel.
We also found that leaving the uninstalled ECD close to the base (instead of putting them further away) did not noticeably affect the position of the optic, as initially suspected (however, installing the ECD does change the pitch, as observed before).
Today we adjusted the pitch of all suspensions to 0+-0.5 mrad (assuming the table levelled to this precision, that we were unable to check) using an optical lever (actually IM4 should be adjusted to +4.1 mrad, but since all the suspensions will need to be balanced again once we put he ECD in, we didn't bother).
We centered the OSEMs (intial centering was well within +- 50 um, but after moving them around it degraded to a little better than +-80), cleaned the setup a bit, clamped the suspensions with 4 clamps each and left them under the barrel.
I took TF of Y, P and L (attached), applying small actuation offsets to make the OSEM work around the central position. The transfer functions show no sign of problems, although the peaks are not exactly all in the same place (as already observed at LLO and expected, as the HAUX design does not include any mechanism to fine tune the resonances' position).
At about 22:05 I left the suspensions quiet and with damping off for the night, so tomorrow we can retrieve data for PSDs.
Throughout the day, the CDS group performed multiple updates (cf Dave & Vern ALOG for details). When the computers were handed back to the users, I encountered some difficulties to restore HEPI BSC6. First, I was surprised by the large offsets on the position sensors (>10K counts ~ 15mils). Then, I realized that the pump was turned off. But after turning the pump back on, the HEPI did not come back to its nominal position. Some tests are currently being performed to understand what’s wrong with the HEPI at the end station.
Decent matrix with too small a beam >> Hopeless matrix with a decent size beam.