ryan.crouch@LIGO.ORG - posted 18:38, Tuesday 18 June 2024 (78530)
Weekly In-lock charge measurement

Last checked in alog78384

Closes FAMIS 28358

While the SUS_CHARGE guardian LOG shows no errors in the measurement, ITMX, and ITMY failed to be processed. ITMX complained of bad coherence and or failed measurements:

" UserWarning: Cannot calculate alpha/gamma because some measurements failed '             'or have insufficient coherence!
  warn("Cannot calculate alpha/gamma because some measurements failed ' \ "

ITMY had the following error when trying to load the data:

"ValueError: no Fr{Adc,Proc,Sim}Data structures with the name H1:SUS-ITMY_L3_ESDAMON_DC_OUT_DQ"

 

Images attached to this report
H1 SQZ
naoki.aritomi@LIGO.ORG - posted 16:52, Tuesday 18 June 2024 (78529)
Optimal SQZ angle depends on OPO PZT voltage

As shown in the attachment, SQZ unlocked for unknown reason at 2024/6/18 23:12:09 UTC and the range got much worse after it relocked. We ran the SCAN_SQZANG and the range was recovered. The optimal SQZ angle changed from 225 to 203 after relocking and it seems due to the different OPO PZT voltage.

Images attached to this report
LHO General
thomas.shaffer@LIGO.ORG - posted 16:26, Tuesday 18 June 2024 (78509)
Ops Day Shift End

TITLE: 06/18 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 122Mpc
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY: Quieter maintenance day. Relocking was fully automated after and initial alignment. We have been locked for 3.5 hours. The SQZer has unlocked a few times since the team finished their table work, and Naoki has been looking into this.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
22:41 SAF LVEA LVEA YES LVEA IS LASER HAZARD 15:22
15:03 Property Christina EY, EX, FCES, LVEA n Property search 17:03
15:03 SAF Camilla LVEA - Transition LVEA to laser safe 15:18
15:09 VAC Gerardo, Jordan, Isaiah LVEA - HAM4 ion pump troubleshooting 15:26
15:16 PCAL Francisco, Tony, Miriam EX Yes PCAL measurement 16:37
15:17 FAC Chris, Eric, Tyler LVEA n Put crane lights back in, move lift, other cleanup from film last week 16:10
15:18 - Corey, Photographer LVEA, FCTE n Taking pictures 17:19
15:34 SUS Rahul EY n Charge measurements 17:09
15:40 FAC Karen, Kim FCES n Tech clean 16:02
15:43 VAC Travis EX yes Check on vac equipment 16:07
15:53 CDS Richard, Sheila LVEA n Check on magnetometer 15:57
15:55 CDS Fil EY, EX - Looking for analyser 18:06
15:57 CDS Ryan S CER n Look at pulizzi 15:58
16:03 FAC Kim EX - Tech clean 17:03
16:03 FAC Karen EY n Tech clean 16:49
16:05 VAC Gerardo, Janos, Jordan, Isaiah, Travis LVEA n Pulling cables 18:03
16:32 PSL Jason, Ryan S LVEA n Grab laser and move chiller 17:32
16:45 FAC Chris EY n Replace fan filters 19:04
16:58 CDS Erik CER n Swap pulizzi power supply 17:28
17:04 SQZ Kar Meng Opt Lab local SHG work 19:37
17:18 FAC Karen, Kim LVEA n Tech clean 18:35
17:29 CDS Dave, Jonathan - n DAQ restart 17:40
17:54 FAC Tyler OSB, EX, EY n Roof inspection 18:44
18:00 CAL Rick PCal Lab -   19:13
18:07 - Camilla, surfs LVEA n Tour 18:37
18:18 VAC Travis EX n Unhook turbo from GV20 18:44
18:26 SAF Sheila LVEA YES Transition LVEA to laser HAZARD 18:35
18:32 VAC Janos, Isaiah EX, MX, MY n Gas cyclinder hunt 18:58
18:36 SAF - LVEA YES LVEA is laser HAZARD 05:15
18:36 VAC Gerardo, Jordan LVEA Yes Take pictures in HAM6 from view ports 19:33
18:57 - Ryan S LVEA - LVEA sweep 19:04
18:58 SQZ Sheila, Naoki, Andrei, Terry LVEA YES SQZ table work 20:25
20:17 VAC Janos, Travis MX n Bringing gas 20:33
21:43 SQZ Kar Meng, Terry Opt Lab local SHG work 22:58
22:08 VAC Gerardo MY n Pickup cable chunks 22:48
22:11 - Chris (photographer) Xarm n Driving on arm and taking pictures 00:11

 

H1 General
ryan.crouch@LIGO.ORG - posted 16:00, Tuesday 18 June 2024 - last comment - 16:16, Tuesday 18 June 2024(78526)
OPS Tuesday EVE shift summary

TITLE: 06/18 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 12mph Gusts, 9mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.07 μm/s
QUICK SUMMARY:

Comments related to this report
ryan.crouch@LIGO.ORG - 16:16, Tuesday 18 June 2024 (78527)

23:12 - 23:16 dropped out of observing due to the SQZer loosing lock

H1 SQZ
naoki.aritomi@LIGO.ORG - posted 14:42, Tuesday 18 June 2024 (78519)
Pump AOM and fiber alignment

Andrei, Terry, Naoki

We aligned pump AOM and fiber following 72081.

We set the ISS drivepoint at 0V and measured the AOM throughput. The throughput was 30 mW/60 mW = 50%. We aligned the AOM and got 57 mW/60 mW = 95% throughput.

Then we set the ISS drivepoint at 5V and aligned the AOM to maximize the 1st order beam. The 1st order beam improved from 3.5 mW to 11.5 mW. Then we set the ISS drivepoint at 0V and checked the AOM throughput again. The throughput was only 35mW/60 mW = 58%. We found that bottom screws of AOM for vertical alignment maximized the 1st order beam, but the 0th order beam significantly reduced, which means there is a clipping. This was the case in the last AOM alignment in 77508.

To avoid the clipping, everytime we aligned the AOM and improved the 1st order beam, we made sure that the 0th order beam is not clipped. We ended up with 10.5 mW of 1st order beam and 55 mW of 0th order beam.

After AOM alignment, we aligned the pump fiber, but the fiber alignment did not improve much.

We reverted the OPO trans setpoint from 70 to 80, which was done in 78467.

H1 CDS
david.barker@LIGO.ORG - posted 13:58, Tuesday 18 June 2024 - last comment - 14:01, Tuesday 18 June 2024(78524)
CDS Maintenance Summary: Tuesday 18th June 2024

WP11924 TW0 offload

Dave:

The past 6 months of raw minute trend were archived on TW0 and the NDS process on h1daqnds0 was restarted to serve these data from this temporary location while the transfer is ongoing.

The copy of these files from TW0 SSD-RAID to permanent HDD-RAID storage on h1ldasgw0 was started at 09:39 PDT. As of 13:26 PDT, 37 of the 256 directories had been copied. This gives an ETA of Wed 19th 11:50 PDT.

WP11937 DMT Sensemon2

Jonathan, Jamie, John, Dave:

The dmt2epics IOC was updated to add 4 new channels:

+[H1:CDS-SENSMON2_BNS_EFF_RANGE_CLEAN_MPC]
+[H1:CDS-SENSMON2_BNS_EFF_RANGE_CLEAN_MPC_GPS]
+[H1:CDS-SENSMON2_BNS_RED_SHIFT_CLEAN]
+[H1:CDS-SENSMON2_BNS_RED_SHIFT_CLEAN_GPS]
 

DAQ+EDC restart was needed.

Replacement of broken Pulizzi power control unit

Ryan S, Dave, Erik:

Ryan discovered that pwr-cer-pem0 Pulizzi unit which powers the PEM magnetic coil located in the inner cleaning room (between gowning and LVEA, on the wall it shares with the CER) was unresponsive with an error message "Error: telnet to host pwr-cer-pem0 fail". This was a strange failure in that the unit was not pingable or telnetable, but the sw-lvea-aux port it was attached to was not reporting a comm error. Ryan compared this Pulizzi with a working one an nothing suggested it had failed.

Trending back this unit could have failed mid-May, 14th May was the last time it ran successfully.

Erik replaced this unit with a good spare. Ryan is looking to modify the magnetic injection script to verify correct Pulizzi control.

DAQ Restart

Jonathan, Dave:

The DAQ was restarted for the DMT change. This was unremarkable other than gds0 needing a second restart.

 

Comments related to this report
david.barker@LIGO.ORG - 14:01, Tuesday 18 June 2024 (78525)

Tue18Jun2024
LOC TIME HOSTNAME     MODEL/REBOOT
08:34:38 h1daqnds0    [DAQ] <<< 0-leg restart
10:31:11 h1daqdc0     [DAQ]
10:31:23 h1daqfw0     [DAQ]
10:31:23 h1daqnds0    [DAQ]
10:31:23 h1daqtw0     [DAQ]
10:31:31 h1daqgds0    [DAQ] <<<< 2nd restart needed


10:31:50 h1susauxb123 h1edc[DAQ]  <<<< EDC for DMT slow channels addition


10:32:02 h1daqgds0    [DAQ] <<< 1-leg restart
10:36:22 h1daqdc1     [DAQ]
10:36:35 h1daqfw1     [DAQ]
10:36:35 h1daqtw1     [DAQ]
10:36:37 h1daqnds1    [DAQ]
10:36:45 h1daqgds1    [DAQ]
 

LHO General
thomas.shaffer@LIGO.ORG - posted 12:49, Tuesday 18 June 2024 (78523)
Ops Day Mid-Shift Report

Maintenance activities finished up just before noon, and the SQZ team has transitioned the LVEA back to hazard to work on SQZT0. I was able to start initial alignment early and we are now on DC readout.

H1 ISC (CAL, CDS)
jeffrey.kissel@LIGO.ORG - posted 12:37, Tuesday 18 June 2024 - last comment - 15:57, Thursday 20 June 2024(78516)
Investigating the High Frequeny Performance of the OMC DCPD Anti-aliasing System
J. Kissel

I'm on a slow-but-steady adventure to characterize the performance of the digital anti-aliasing system for the new 524 kHz ADC readout of the OMC DCPDs photocurrent. 
The big picture goal is too look at the 524 kHz data, and make sure that it's filtered enough before down sampling to 65 kHz and then 16 kHz, such that none of "fun and interesting" features that are real DARM signals (or analog or digital artifacts of the ADC) in the 10 - 100 kHz region appear down-converted at low frequency.

As usual, when I *look* at something for the first time, hoping for a simple "yup, works as expected," I instead get 60 new questions.

Executive summary: 
While I don't see anything obviously detrimental to the 16 kHz data, I see a confusing, frequency-independent noise floor in the filtered version of the 524 kHz OMC DCPD A channel *only* in NOMINAL LOW NOISE that I can't explain as either ADC noise, spectral leakage, or limits of numerical precision. Apparently, in NOMINAL LOW NOISE, we're not getting nearly as much digital anti-aliasing as designed.

Plots and their Explanation, Exploration, and Conclusions:

First, I compare the amplitude spectral densities of the two 524 kHz channels available for DCPD A during NOMINAL LOW NOISE vs. when DARK (the IMC OFFLINE), "as the are" 
    - H1:OMC-DCPD_A0_OUT (calibrated into milliamps [mA] on the DCPDs),                        # HAS 526-to-65 kHz and 65-to-16 kHz digital AA filters
    - H1:OMC-PI_DOWNCONV_SIG_OUT (a copy of the DCPD A channel, also calibrated into [mA]),    # DOES NOT HAVE digital AA filters

The first attachment, H1OMCDCPDs_0p1HzBW_10avgs_524kHzSignals_NLN_vs_DARK_AprtHz.png shows this comparison. 
These are the *output* of the respective filter banks, so the front-end filter banks already do *most* the work of inverting the frequency response of the TIA and Whitening filters, below 10 kHz.
That front-end calibration also already accounts for the fact that the analog voltage coming into the ADC is copied 4 times and summed, and does the "divide by four" gain of 0.25 to create an average of the voltage copies.
Importantly, the TIA and whitening's analog 11130 & 10170 and 44818.4 Hz poles are *not* inverted, so they remain a part of the frequency response of the readout -- and thus they remain uncompensated for in the plot.
The *only* calibration applied in DTT for these channels is a simple 1e-3 [A/mA].
    NOMINAL LOW NOISE, "reference" data for the two channels -- shown in CYAN and MAGENTA -- was taken a last week on 2024-06-12 20:45:46 UTC.
    DARK noise, "live" data for the two channels -- shown in RED and BLUE -- was taken this morning, with the IMC offline at 2024-06-18 15:10:28 UTC.

One immediately notices several "interesting" things:
    (1) The CYAN, OMC-PI_DOWNCONV_SIG_OUT version of the (4x copy average of the) DCPD A signal -- that doesn't have digital anti-aliasing filters applied -- shows lots of "fun and interesting" features on the DCPDs above 8 kHz in NOMINAL LOW NOISE. 
    (2) Comparing the CYAN NOMINAL LOW NOISE data with BLUE DARK data, we see that a lot of these "fun and interesting" features in the 8 kHz to 100 kHz region are real features from the detector. My guess is that this is the forest of acoustic modes of optics that appear in the DARM signal.
    (3) MAGENTA OMC-DCPD_A0_OUT version shows that most of these features *are* filtered out by 30 kHz by the digital AA filtering, BUT -- they hit some frequency-independent noise floor at "1e-12 [A/rtHz]."  This noise floor is obviously *not* a real noise floor on the DARM light coming in on the PDs, nor some sort of current noise, given how feature full the CYAN unfiltered version is. As such I will for the remainder of the aLOG put the quantitative numbers about this noise floor in quotes. What is this noise floor?
    (4) Comparing MAGENTA NLN trace and RED DARK trace, we see that when the DCPD is DARK, we see the full expected frequency response of the digital AA filters. Why are the filtered data's DARK and NLN noise floors so different?

Hoping to understand this noise floor better, I calibrated the traces into different units -- the units of input voltage in to the low-noise, 18 bit, 524 kHz ADC.
The second attachment, H1OMCDCPDs_0p1HzBW_10avgs_524kHzSignals_NLN_vs_DARK_CastAsADCInput_VprtHz.png, shows this different version of the ASD.

To calibrate into ADC input voltage units, I calibrated all the DTT traces by the following calibration (with detailed poles and zeros pulled from the calibration group's DARM loop model parameter file, pydarm_H1.ini from the 20240601T183705Z report): 
    zpk([2.613;2.195;6.556],[5.766+i*22.222;5.766-i*22.222;32.77;11130;10170],219.65,"n") # The TIA response [V/A], normalized to have a gain of 100e3 [V/A] at 1 kHz
  * zpk([0.996556],[9.90213;44818.4],1,"n")                                               # The Whitening Response [V/V]
  * gain(0.001)                                                                           # The inverse of the [mA]
where notably, I continue to exclude the two 11130, 10170 Hz poles and the 44818 Hz pole from the TIA and whitening filter's analog response. 

To compare against our model of the noise of the low-noise, 18-bit ADC sampled at 524 kHz (derived from the data in LHO:61913, shown to be comparable in G2201909), I took that model and divided by sqrt(4) = 2.0 to account for the 4 copies of the ADC noise that appear during the digitization of the 4 copies of the analog voltage. 

I also show the RMS voltage (color coded to match the corresponding ASD) in case that's important for discussions of noise floors.

This exposes more interesting things, and rules out one thing that this 1e-12 [A/rtHz] noise floor might be -- it's *not* the ADC noise floor.
    (5) Both version of the DARK noise traces, BLUE and RED show that the data agree with the noise model below 5 Hz, which gives me confidence that the scale of the model is correct across all frequencies.
    (6) The MAGENTA trace shows that, when recast into ADC input voltage, the filtered nominal low noise data's "1e-12 [A/rtHz]" noise floor is "1e-6 [V/rtHz]," which is a factor of ~4 above modeled ADC noise floor.
    (7) The BLUE trace shows the dark noise -- without the digital anti-aliasing filters -- is *also* above the ADC noise, is frequency-dependent, and *below* the MAGENTA filtered NOMINAL LOW NOISE data in the 20 to 200 kHz region. 
(5), (6), and (7) all give me confidence that this frequency independent noise is *not* ADC noise
    (8) The ADC input voltage 
        (a) during NOMINAL LOW NOISE data spans 5 orders of magnitude (0.2 [V_RMS] total in the CYAN NLN unfiltered trace, w.r.t. this 1e-6 [V/rtHz] high frequency noise floor in the filtered MAGENTA trace), and
        (b) the DARK data spans 6 orders of magnitude (5.4e-4 [V_RMS] of the BLUE unfiltered trace, w.r.t the 1e-10 [V/rtHz] at the lowest 65 kHz notch in the RED trace). But BOTH are still above the dynamic range of where floating point precision would be causing problems -- dynamic range of 8 orders of magnitude. So, I don't think it's a numerical precision issue, unless I'm misunderstanding how that works.
    (9) Also, given that the NOMINAL LOW NOISE data spans less orders of magnitude that the DARK noise data, and yet the filtered RED data does *not* show any such frequency-independent noise floor, I also don't think it's an issue what window I've chosen on the ASDs (it's the default Hanning window, for the record).

Just to add another view in further different units, to explore (8) a little better, I attach a third version of the plot, but cast into the 18 bit ADC's counts.
This is the third attachment, H1OMCDCPDs_0p1HzBW_10avgs_524kHzSignals_NLN_vs_DARK_CastAsADCInput_ctprtHz.png.
The further calibration is a simple multiplication of the ADC Input Voltage by a further 2^18/40 [ct/V]. 
(The inverse of this ADC voltage calibration has already been done in the "raw" channels in [mA], and the factor of 4 for the number of copies being summed has already been accounted, so I *can* treat these channels like a single ADC channel).
    (10) Not much more interesting here, the MAGENTA trace showing "1e-12 [A/rtHz]" or "1e-6 [V/rtHz]" high frequency noise floor of the filtered NOMINAL LOW NOISE data, now in ADC counts, lands at an uninteresting "7e-3 [ct/rtHz]", compared to an RMS of ~1000 [ct_RMS]. So, it's not like we're bottoming out on ADC counts or ADC precision.

I'd really like to understand this noise, since it's present during NOMINAL LOW NOISE, and it's indicating that there's some flaw in our digital anti aliasing.
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 12:40, Tuesday 18 June 2024 (78521)
In case folks are interested, I attach a few zooms of the > 10 kHz region.

The first two attachments are in "raw" DCPD current units [A/rtHz], and the third attachment is in ADC input voltage units [V/rtHz] so one can compare against the ADC noise floor model.
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 13:00, Tuesday 18 June 2024 (78522)
The calibration in DTT was not so easy. 

For the DCPD channels, I ended up creating the appropriate calibration filter in foton, then exporting the trace to text file, then by-hand copying-and-pasting that text file's results into the funtional table in "Trans. Func." tab. I used this method and foton because I can
   - have separate filters for each TIA, Whitening, mA to A, ADC gain, components
   - bode plot the answer so I can sanity check the frequency response, and confirm the overall scale factors is correct (in particular, that the TIA had magnitude of 100e3 [V/A] at 100 kHz)
rather than the DTT "Pole/Zero" tab, where
   - the calibration filter is all in one long collection of poles and zeros, 
   - I have no idea how the poles and zeros are normalized, and 
   - I can't visually check the filter response and magnitude.

I attach a screenshot of the foton design that shows all the filters needed above,
   - the TIA
   - the Whitening
   - the mA per A gain
   - the ADC ct per V gain 
and the "Command" field shows all of these filters' details multiplied together (separated by the asterisk).

I used the filter file 
    /opt/rtcds/lho/h1/chans/
        H1IOPOMC0.txt
from the h1iopomc0 front-end model because it's a 524 kHz filter file, allowing me to add frequency response features above the traditional 8 kHz Nyquist frequency of a 16 kHz model (even though I didn't end up adding any of those features, I had thought for a while that I would have, given that the TIA and Whitening have the above mentioned ~11, 10, and 44 kHz poles. But, as discussed above, I don't need them.)
Note, I didn't save this filter or load it into the front-end or anything, I just used the filter bank as a sandbox to create the calibration filters.

For the ADC noise, I took the noise model from the svn directory for the OMC whitening design update,
     /ligo/svncommon/CalSVN/aligocalibration/trunk/Common/Documents/G2201909/
         BHD_PreampOnlyAndAdcNoise_10mA_6dBSqueeze_512kHzSample_adc.txt
which is already in ADC input voltage [V/rtHz] units, then imported it into matlab, divided by 2 and re-exported for the average-of-four-channels ADC noise curve in the main aLOG's second attachment.
Then, I multiplied this average-of-four-channels noise estimate by the 2^18/40 [ct/V] and re-exported for the ADC noise curve in the main aLOGG's third attachment.

The DTT templates for this work live in 
    /ligo/home/jeffrey.kissel/2024-06-12/
        2024-06-18_151028UTC_H1OMCDCPDs_DARK_0p1BW_10avgs.xml                      # calibrated into raw DCPD current in [A/rtHz]
        2024-06-18_151028UTC_H1OMCDCPDs_DARK_0p1BW_10avgs_calibratedtoADCV.xml     # calibrated into ADC input voltage in [V/rtHz]
        2024-06-18_151028UTC_H1OMCDCPDs_DARK_0p1BW_10avgs_calibratedtoADCct.xml    # calibrated into ADC counts in [ct/rtHz]


I attach the calibration files and ADC noise curves produced for this aLOG as well (which are also in that 2024-06-12 directory in my home folder).
Images attached to this comment
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 15:57, Thursday 20 June 2024 (78559)
J. Betzwieser, E. von Reis, J. Kissel
T990013 DTT Manual, Section 3.1.4

It *is* a numerical precision issue -- I *didn't* understand understand "how it worked" er, what I was missing.

Long story short --- the above DTT ASDs have the "Remove Mean" option checked as ON. 
The data actually contains a comparatively *huge* DC component -- the well known 20-ish [mA_peak] of light that comes in from the DARM offset. 
The front end data is spit out to test points at single precision.
Compared with the ~1e-12 [A_rms/rtHz] or less signal I'm trying to explore, that *is* a huge dynamic range that does push the numerical limits of the single-precision test point data.

Here, I attach the same ASD comparison between the "raw" 524 kHz ADC channel (the OMC-PI_DOWNCONV channel) and the output of the OMC-DCPD_A0 bank after the digital down sampling filters. 
First attachment is the full frequency vector, and the second attachment is the high-frequency portion.
For all traces, the detector is in NOMINAL LOW NOISE, and for this purpose I found it more natural to use the signals calibrated into ADC input voltage units. However, in the attached, I now compare the two channels under three different configurations of the DTT analysis software:
    (1) The same CYAN and MAGENTA, nominal low noise data as in the main entry taken on 2024-06-12. This still has the "Remove Mean" option checked, *and* is using the control room's default diaggui software suite, which computed the pwelch algorithm using single-precision.
    (2) I took new data today 2024-06-20, also in nominal low noise, but this GREEN and BROWN data set is using Erik's more feature-full developmental
        /usr/bin/diaggui_test
       which computes the pwelch algorithm using double precision, and
    (3) One more data set, taken shortly after (2), in BLUERED, which uses the double-precision calculation, but I've *unchecked* the "Remove Mean" option, and thus exposed the DC component of the signal.

Trending a typical NLN segment, the first "officially named" available channel in the digital chain of the DCPD readout is the sum of the 4 copies of the analog voltage. 
That's H1:OMC-DCPD_A0_IN1 (or the 16 Hz readback version H1:OMC-DCPD_A0_INMON), and that reads 
    116700 [ct] * (40/2^18 [V/ct]) = 17.8 [V_DC] * (1 / 4 [copies]) = 4.45 [V_DC].
The unofficial generic CDS channels for each ADC channel are also available (H1:IOP-OMC_MADC0_EPICS_CH[0,4,8,12]), that these signals, before the sum, also corroborate 4.5 [V_DC], 
    29200 [ct] * (40/2^18 [V/ct]) = 4.45 [V_DC]
So that's the upper end of the dynamic range of the signal we're dealing with, in ADC input voltage units.

Here's what we see in the attachments:
    (i) When we uncheck the "Remove Mean" box, the secrets are revealed -- the lowest frequency data point reports ~4 [V_DC]
    (ii) -- and echo of (b), given the dynamic range of this signal, computing pwelch algoirthm in single precision or double precision results in the same noise floor of "1e-6 [V/rtHz]" above ~10 kHz where the real noise is small.

But -- it isn't 8 orders of magnitude smaller... so I also wonder if we hit this noise because of the order in which we compute the filters within the A0 bank. For the purposes of discussion, I attach 
    - the total transfer function of the A0 bank, H1OMCDCPD_A0_FilterBank_TF.png
    - each of the filters in the bank, in order, H1OMCDCPD_A0_FilterBank_Component_TF.png
    - the MEDM screen, for ease of interpretation H1OMCDCPD_A0_FilterBank_MEDM.png

The front-end computes everything in double precision, right?
Images attached to this comment
H1 General
ryan.short@LIGO.ORG - posted 12:04, Tuesday 18 June 2024 (78520)
LVEA Swept Following Maintenance

The LVEA has been swept at the conclusion of (most) maintenance activities. Team SQZ was still working on-table (can happen alongside locking) and VAC folks were finishing up taking pictures through HAM6 viewports.

I unplugged the Genie lift in the West bay and coiled up the cord next to it. Otherwise, everything looked okay.

H1 SEI
jim.warner@LIGO.ORG - posted 11:59, Tuesday 18 June 2024 (78518)
New state added to SEI_DIFF, all chambers will follow BSC2 below ~100mhz

Been thinking about CPS diff stuff lately, and I want try making some changes to what chambers are connected. For the most part, the individual corner cavities (MC/PRCL, MICH, SRCL) were separated, i.e. HAM2-3 were connected by cps diff, BSC123 were a separate set of loops, etc. I've now set it up so that all of the chambers are tied to BSC2. If this is suspected of causing a problem, it will be easy to switch back to the old config: new state is called BSC2_FULL_DIFF_CPS, the old config we used for years was just FULL_DIFF_CPS. Find and replace in SEI_ENV, load and take SEI_ENV through a down up cycle.

The only real risk to this is kicking BSC2 would probably trip all of the chambers. Don't do that.

Images attached to this report
H1 CDS
jonathan.hanks@LIGO.ORG - posted 11:07, Tuesday 18 June 2024 (78517)
WP 11934, restart of DMT systems for updated sensemon2 with a reflection of the channels into CDS
As per WP 11934 the dmt-runtime-config package was updated on h1dmt1 and h1dmt2 followed by a reboot at around 9:40am local time.

This was to update the calculation of sensemon2 to be based off of the cleaned data.  It is desired to have these values available in CDS, so we updated the dmt2epics IOC to grab the EFF_BNS_RANGE and EFF_RED_SHIFT values and reflected them into EPICS.  After testing that we could retrieve the data from the DMT we added the channels to the EDC and rebooted the daqd around 10:30am localtime.

The new channels are:

H1:CDS-SENSMON2_BNS_EFF_RANGE_CLEAN_MPC
H1:CDS-SENSMON2_BNS_EFF_RANGE_CLEAN_MPC_GPS
H1:CDS-SENSMON2_BNS_RED_SHIFT_CLEAN
H1:CDS-SENSMON2_BNS_RED_SHIFT_CLEAN_GPS

TJ will watch the new Sensemon2 range plot as we start to lock later today and will update the FOM display if this is working well.
LHO VE
david.barker@LIGO.ORG - posted 10:16, Tuesday 18 June 2024 (78515)
Tue CP1 Fill

Tue Jun 18 10:08:07 2024 INFO: Fill completed in 8min 3secs

 

Images attached to this report
H1 CAL (SUS)
camilla.compton@LIGO.ORG - posted 10:07, Tuesday 18 June 2024 (78433)
Kappa TST not changing much since October 2023
Kappa TST has not been changing much since October 2023.
Question: why did Kappa_TST stop changing? Plot attached. Unsure.  In O4b the new DARM reduced force used on ETMX L3 but this seemed to happen after kappa_TST stopped changing.

As described in 76326  "kappa_TST is the time-dependent correction factor that tracks the TST stage actuation strength relative to the last time the calibration was updated", but the calibration hasn't been updated more regularly, so if it was still changing, we should see it. Francisco has made a script to automatically adjust the ETMX L2L drivealign to compensate for Kappa_TST but this only started this week: 78425.

In October Ryan's anaylsis showed the Kappa TST drift agreed up with increasing charge on ETMX from in-lock charge measurements: 73613, recent in-lock charge measurements in 75456 show the charge hasn't changed much. To do: check on in-lock charge measuremtns and add a longer time scale plot.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 09:48, Tuesday 18 June 2024 (78513)
TW0 raw minute trend file copy started

WP11927 TW0 Offload

The copy of the past 6 months of raw minute trend files from h1daqtw0 to h1ldasgw0 via h1daqfw0 was started at 09:39.

Prior to the start of the copy, the past 6 months of files were 'frozen' in a temporary minute_raw_1402759218 directory on tw0 at 08:20 this morning. The NDS process on h1daqnds0 was restarted at 08:34 to serve these data from their temporary path.

H1 PSL
ryan.short@LIGO.ORG - posted 08:39, Tuesday 18 June 2024 (78512)
PSL 10-Day Trends

FAMIS 20702

About 4 days ago, AMP1 had a slight drop in output power while the NPRO had a slight jump. AMP2 power also had a hit at the same time, but is largely unchanged.

The rise/fall in PMC reflected/transmitted power again looks to have leveled off a bit since last week.

Images attached to this report
H1 General
camilla.compton@LIGO.ORG - posted 08:24, Tuesday 18 June 2024 (78511)
Pre- maintenance LVEA walk through

As walking through the LVEA to do the laser transition, things to note: the high bay and clean receiving lights were on, west bay genie lift was plugged in, I unplugged an unused extension cored by CO2Y, I heard a cricket by the y-manifold but couldn't find it, the HAM3 dust monitor has an extension cord running to it but isn't plugged in.