Displaying reports 85001-85020 of 88650.Go to page Start 4247 4248 4249 4250 4251 4252 4253 4254 4255 End
Reports until 23:21, Tuesday 07 August 2012
H2 ISC
bram.slagmolen@LIGO.ORG - posted 23:21, Tuesday 07 August 2012 (3752)
OAT Locking

I locked the arm and did a dither alignment (>8000 on the REFL diode) and engaged the off laod at 23:10h local time, so good times are from 23:15pm.

With the work on the RefCav I will be keen to see the noise at higher frequencies. Vincent reinstalled the boosts on the ISI isolation, so all should be nice.

Should be good for the night.

LHO General
patrick.thomas@LIGO.ORG - posted 19:30, Tuesday 07 August 2012 (3751)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot. The dust monitor in the clean room over HAM 3 (location 15) has a calibration failure. I'm not sure when it started, but I think it was sometime today.
Non-image files attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 18:02, Tuesday 07 August 2012 (3750)
Added ~5 quarts turbine oil to Kobelco purge-air compressor


			
			
LHO VE
kyle.ryan@LIGO.ORG - posted 17:59, Tuesday 07 August 2012 (3749)
Lots-0-Leaks
I was only able to test ~20 joints today on the Vertex due to leaks.  Aaaargh!  At this rate, I'll need two or more additional days to finish!  A few of the leaks were on "legacy" joints circa 1998 but most were on new aLIGO joints.  I was able to retorque and get most of these to seal but this wastes time and is "not on the schedule" - better to do it right the first time!
H2 ISC
bram.slagmolen@LIGO.ORG - posted 13:15, Tuesday 07 August 2012 (3745)
OAT RefCav

During the reboots I took the opportunity to have another look into the OAT RefCav in the optics lab.

I removed the 50/50 beam pslitter infront of the RF LSC diode, so now ~30 mW of power is incident. In addition in optimised the HWP infront of the PM to reduce the AM, 2f_sb = < -80dB.

The few irises in the beam path are closed down, I looked with the viewer and reduced the iris so it was just not clipping.

I didn't find a low enough ND filter to o the paracitic interfernce hunt.

The cavity locks stable with a UGF ~300kHz, the settings are

Coarse Fine Common Fast Offset
351 420 350 540 293

The Laser temperature on the controller displays: T+40.991, the slow output (T-ed to the laser slow input and the oscilloscope) is at -620 mV.

Once we get the cavity locked again we can see if we gained anything.

H2 SEI
vincent.lhuillier@LIGO.ORG - posted 09:28, Tuesday 07 August 2012 - last comment - 14:14, Tuesday 07 August 2012(3744)
Boost filters back in FM10

I put the boost filters back in FM10 of the ISO filter bank on BSC6 and BSC8. They switch when crossing zero but I have changed the tolerance (300 to 50 counts) and the time out (2s to 20s).

Comments related to this report
vincent.lhuillier@LIGO.ORG - 14:14, Tuesday 07 August 2012 (3747)

Instead of engaging the filters when zerocrossing, the ramp (10s) is used.

H2 ISC
bram.slagmolen@LIGO.ORG - posted 20:57, Monday 06 August 2012 (3743)
OAT WFS demod phase

Elli and Bram

We went to the EY and injected a sine wave at 2280 Hz, 200 mVpp into the CMB-B (PDH), Exc A input. Then we used ddt to measure the tranfer coefficients of the SegX_Ix/SegX_Qx. We optimised the demodulation phase and maximised the transfer coeeficient. Although we could not zero the Q-phase, we got a factor of ~30x between the I and Q phase for all segments in both WFS-A and WFS-B.

in between the measurements we aligned the beams onto the WFS but adjusting the picomotor mounts. We actually did this manual and did NOT use the picomotor driver, which would be nice in the future ...

Now we can use the WFS for alignment feedback to the Quads, well at least measure the TFs.

LHO General
patrick.thomas@LIGO.ORG - posted 19:43, Monday 06 August 2012 (3742)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Non-image files attached to this report
H2 SUS
szymon.steplewski@LIGO.ORG - posted 16:48, Monday 06 August 2012 (3741)
Grounding Plugs for ITMY coil drivers

I attached 5 grounding plugs to the ITMY coil drivers Test Input this afternoon ~ 4:30 pm.  Three were connected at the top stage driver, and one each for UIM and PUM drivers.  I plan on doing the same for ETMY tomorrow before making measurements of the coil driver noise.

H1 SUS
betsy.weaver@LIGO.ORG - posted 16:25, Monday 06 August 2012 (3740)
H1 MC2 installed in HAM3

(Betsy, Travis, Deepak, Cheryl, Dale on the camera)

All the prep work paid off and the MC2 was installed into the chamber relatively easy this afternoon.  Using the genie, we hoisted it up to the elevator which was attached to the arm, attached the spacer to the bottom of the suspesnion, and then used the arm to swing it into place on the ISI table against the cookie cutter.  We added a few dog clamps to make sure it doesn't walk away overnight.  Tomorrow we continue adding dog clamps, hooking up cables, etc.

LHO General
gerardo.moreno@LIGO.ORG - posted 16:09, Monday 06 August 2012 (3739)
Ops Summary

Report of site activities:

H2 SUS
szymon.steplewski@LIGO.ORG - posted 15:29, Monday 06 August 2012 (3735)
QUAD SUS OSEM sensor diagonalization

During the past few weeks I have been working on calibrating the sensor readouts from the Quad Suspension OSEMs on all four stages: main chain top M0, reaction chain top R0, upper intermediate mass (L1 stage or UIM), and penultimate mass (L2 stage or PUM).  One way to check the OSEM readouts is to measure their response to an excitation of the top mass, and then compare this to the response predicted by the 20120601TMproductionTMrehang mathematical model.  The Quad Suspension has a 0.43 Hertz mostly "Longitudinal" mode, and exciting this mode by shaking the main chain top mass will result in peaks at 0.43 Hz for all OSEM sensor spectra (M0F1 spectrum attached as an example).  Comparing the peak height data of each OSEM at 0.43 Hz to the data predicted by the model should show any dissimilarity between the predicted behavior of the OSEM sensors and what is actually seen.  

The file OSEMsensorplot.pdf shows the magnitude of the OSEM sensor readouts (vertical axis) for each OSEM ID(horizontal axis) scaled so that the magnitude of the Main Chain F1 OSEM is always one.  I tried a few different methods of measuring the power spectra that generate this plot, and they are labeled on the side of each plot.  In each case damping of the top stage reaction and main chains was OFF.

The model prediction is the sensor response at the 0.43 Hz peak for each OSEM derived from the mathematical model of the quadruple suspension.  The measurements labeled "White Noise" are from excitations of white noise into all Main Chain TOP degrees of freedom (Longitudinal, Transverse, Vertical, Roll, Pitch, and Yaw).  These white noise power spectra were collected WHILE the excitation was being performed.  In the 7/3/2012 White Noise measurement the coherence in the L2 stage OSEMs was terrible, and so these data points are not reliable.  The measurements labeled "Offset" are derived from an excitation where each main chain TOP degree of freedom was displaced with a static offset value after a turn-on ramp time of 10 seconds, then this static offset was instantly changed to zero to let the suspension swing freely.  Lastly the measurements labeled "Sine Relax" were taken by exciting the main chain TOP mass Longitudinal DOF with a 0.43 Hz sine wave drive for about five minutes, then the drive was turned off and the suspension allowed to swing freely for about 2 minutes before the power spectra were taken.

The sensor plot shows that the different measurement approaches lead to consistent OSEM data, but we see immediately that the lower stages have some problems.  The L1 stage magnitudes on each suspension appear slightly lower than predicted, but only ITMY OSEM L1LL is way off.  This could be a problem with the L1LL alignment or an electronic issue that fails to correctly communicate the position of the flag on that sensor.

The L2 stage is troubled with multiple symptoms, each OSEM is well below the model prediction.  I am still struggling to understand why the response is so small.  One glaring problem is that the L2UR sensors on both ETMY and ITMY are practically zero compared to the other L2 OSEMs.  I suspect that these specific sensors dead or barely working, but will need to check this somehow.

Images attached to this report
Non-image files attached to this report
H2 CDS
david.barker@LIGO.ORG - posted 13:05, Monday 06 August 2012 (3738)
h2tcsl0 install TCS ITMY model, H2 DAQ restart

I replaced the H2GDSAWGL0 model with H2TCSITMY on h2tcsl0 following the install of a second ADC card in this front end. The front end now has 2 ADC and 1 DAC cards. PEM uses the first ADC, TCS uses the second ADC and the DAC card.

The H2 DAQ was restarted with the new configuration.

The h2tcsl0 restart invalidated all the front end data. After the DAQ restart I had to restart the data streamers on each model, so the H2 data gap was longer than anticipated at about 10 minutes.

H1 SEI
corey.gray@LIGO.ORG - posted 10:50, Monday 06 August 2012 (3733)
HAM3 ISI Spring Profiles

To measure the Spring Profile one must use a plunge micrometer and then measure the distance from the top of the Optics Table down to the Spring.  For each Spring there are two access points/thru-holes for the micrometer:  at the Spring Tip & at the Spring Base (I forgot to measure the Spring Base measurement when I did this last Wed, so I re-did the measurement this morning)

HAM3 Spring Profiles

Spring 1 (where tip location warrants corner location, in other words Spring1 is mounted on Spring Post which has Corner 3 Actuator & CPS, but Tip is in Corner1 zone)
base:  0.388"
tip:  0.375"

Spring 2
base:  0.399"
tip:  0.381"

Spring 3
base:  0.390"
tip:  0.378"

These measurements were made with our clean plunge micrometer.  It was fitted with a 2" extension.  Measurements are +/- 0.0005" (this is the slop of the locked Lockers).  I also made Tip measurements where I avoided the Spring Hatches---just stayed on the Optics Table.

H1 SEI
greg.grabeel@LIGO.ORG - posted 10:23, Monday 06 August 2012 (3734)
Unit6 storage container purge
On July 31st Unit #6 was placed into a storage container. Aug. 1st a purge was started at 10:30am. Ambient air was 8.2 tdºC at 24.7ºC. Boil-off LN2 was run at 20lpm until about Aug. 3rd 2:00pm.

I tried to dry out the bag the wand was in and get a baseline for the purge gas, but after approximately 15 minutes of purging just the ameristat bag and the dewpoint wand was reading -34.4tdºC and 25.5ºC. I must have been picking up a fair bit of moisture from the line and bag.

Interestingly Unit 6 in the storage container dropped in dew point much faster than HAM6 in a shipping container. Maybe there is a significant difference between the shipping and storage containers. Do the inflow and outflow locations for the purge make a difference? Less surface area in a storage container?
Images attached to this report
H2 DAQ
james.batch@LIGO.ORG - posted 09:37, Monday 06 August 2012 (3732)
Restarted h2nds0 daqd process
Found that the daqd process had quit on h2nds0.  Last error message in the log file:

Invalid broadcast received; seq=3177250 tp_seq=3177267 gps=1028180001 tp_gps=1028180002 gps_n=62500000 tp_gps_n=187500000

Restarted daqd process.
Logbook Admin Bug
jeffrey.kissel@LIGO.ORG - posted 08:55, Monday 06 August 2012 (3731)
Hitting "Upload File" without a file chosen shows white screen
If a user is in the middle of uploading files (or even just getting started), and he forgets to select a file for uploading and subsequently hits "UPLOAD FILE" with nothing selected, it takes the user to a blank white screen. Thankfully, nothing is lost, and one can just hit his browser's back button, but the log should throw a warning / error when this situation arises. A pop-up that gray's out the log, saying "You've not selected anything to attach, please browse for a file" with an "OK" acknowledge button would suffice. Or if that's too sophisticated for the infrastructure of the log, this user error should at least take you to another page with the same warning, and a link back to the upload page and/or the add report page. 
H2 AOS
thomas.vo@LIGO.ORG - posted 17:15, Thursday 26 July 2012 - last comment - 16:26, Wednesday 08 August 2012(3614)
H2 ITMY/ETMY Optical Lever Calibration
Jeff K. , Thomas V.

Below are the calibration parameters for the H2 ITMY Optical Lever:
        Slope          Y-intercept
Pitch [ 580.41229822  -11.51774017]
Yaw  [ 689.70532274  -13.3345144 ]


And here are the calibration parameters for the H2 ETMY Optical Lever:
         Slope           Y-intercept 
Pitch [ 1666.80728788   -33.14694715]
Yaw  [ 1727.67131855     23.41350328]

Both sets of calibrations were attained via the same process of moving the QPD along a translation stage and measuring the output signal.  All four sets of slopes are in units of radian*meters.
Images attached to this report
Comments related to this report
thomas.vo@LIGO.ORG - 14:40, Friday 03 August 2012 (3713)
Jeff K. Thomas V.

We have found a non-linear relationship between the way the translation stage moves and the way we were reading out the measurements.  We need to double check the calculations as well as the methodology on retrieving data.  This latter is difficult because even though there is a micrometer on the translation stage it is covered by the laser enclosures, which if we take off, it will introduce ambient light onto the QPD.  We are currently investigating solutions.
jeffrey.kissel@LIGO.ORG - 11:59, Monday 06 August 2012 (3736)
T. Vo, J. Kissel

Pulling out a spare translation stage and measuring the displacement response (in [mm]) to controller demands (in [ct]), we found the following attached relation. Immediately turned off by the non-linearity seen, from our experience with the controlers jolting the translation stage upon power on/off, and from Kissel's recollection of the controllers in i/eLIGO (of which these controls are the same), we've launched into a more sophisticated characterization of the controllers. Given that the non-linearity is roughly 1 [um] over the 1 [mm] range measured, we might be barking up the wrong tree and just be over-reacting, but it should be a quick round of measurements to assess it in more detail.

It should also be noted that the controller can demand from 0 to ~8600 [ct], and we've thus far only exercised it from 0 to 150, since we only need ~1 [mm] range given the size of the Oplev QPD.
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 13:03, Monday 06 August 2012 (3737)
T. Vo, J. Kissel

Here're the results from the more detailed characterization. It looks like, within a small range of operation the controller is indeed linear to the desired level. However, over the full range of the controller, there's certainly some non-linearities present.


Notes:
Linear UP -- commanding the stage to move from 0 (4000) up to 150 (4150), in linear 10 [ct] increments.
Linear DOWN -- commanding the stage to move from 0 (4000) up to 150 (4150), in linear 10 [ct] increments.
Random -- going to each data point in a random order

Each of these should yield the same answer if it's a truly linear system.
Non-image files attached to this comment
thomas.vo@LIGO.ORG - 16:26, Wednesday 08 August 2012 (3758)
Jeff Kissel Thomas Vo

After reviewing the linearity of the translation stage as shown in ALOG 3737, we found that the non-linear regime of the translation stage resides near the end of the rails of the stage but the approximate middle yielded linear results.  We're confident that the increments that we used to translate the stage during calibration for both test masses were small enough and far enough away from the edges so that the non-linearity would have a small affect on our results, this will require further testing to truly be valid (in progress).  That being said, after correcting some errors in the calculations and double checking our numbers, we used the original data to apply to the calibration.  

A noteworthy point: Jeff Kissel used the edrawing from the solidworks model in,

LHO Corner Station: D0901469-v5 
LHO EY Station: D0901467-v6 

to find a more accurate number for the lever arms than previously used, ITMY = 56.4m and ETMY = 6.6m, as opposed to 70m and 6m respectively.  This was taken into account for our last calculation.

Onto the good stuff, the values of the slopes below are in micro-radians*meters:

ITMY
        Slope         Y-Intercept
Pitch [ 25.93274501  -0.51461109]
Yaw   [ 30.81584154  -0.5957635 ]



ETMY
        Slope         Y-Intercept
Pitch [ 54.53112025  -1.01505634]
Yaw   [ 56.56393367   0.79879263]


Attached are the graphs of the linear response curves, the python fitting scripts and the EXCEL spreadsheets to help visualize the underlying calibration calculations. In particular, the excel spreadsheets shows the conversion from controller units into millimeters and then into meters and micro-radians.  Hope this is the last time we'll need to repeat this post, sorry for the troubles!
Images attached to this comment
Non-image files attached to this comment
Displaying reports 85001-85020 of 88650.Go to page Start 4247 4248 4249 4250 4251 4252 4253 4254 4255 End