Reports until 19:11, Wednesday 25 July 2012
LHO General
bram.slagmolen@LIGO.ORG - posted 19:11, Wednesday 25 July 2012 (3599)
Tumble weeds cleaning

At 7:08 the tumble weeds are being gathered.

H1 AOS
jeffrey.kissel@LIGO.ORG - posted 19:09, Wednesday 25 July 2012 (3597)
Oplev ASDs (Preliminary Calibration)
J. Kissel, T. Vo

Now that the optical lever signal chains are functional, it's straight forward to include Thomas' calibration into the signal chain and grab a spectra. Attached are the results for ETMY and ITMY. I'm not sure if I believe the amplitude of the results though. Even though Fabrice has been making excellent progress with H2 ISI ITMY, I don't think we're down to the sub- nrad / rtHz at 0.5 Hz. We'll go through the calibration more thoroughly tomorrow, and see where I've screwed up.

Anyways, for posterity, my calibration is as follows (which, although Thomas only has official calibration for ETMY, I used the same calibration for both assuming the signal chains and lever arms are roughly the same):
 
DOF     ADC Gain         Oplev Calib.   (order of mag.)
Pitch: 40/2^16 [V/ct] * 1666 [urad/V] * 1e-6 [rad/urad] = 1.0168e-6 [rad/ct]
Yaw:   40/2^16 [v/ct] * 1727 [urad/V] * 1e-6 [rad/urad] = 1.0541e-6 [rad/ct]

Non-image files attached to this report
H2 SEI
fabrice.matichard@LIGO.ORG - posted 19:01, Wednesday 25 July 2012 (3596)
ITMY Longitudinal Isolation
Blend Filters were refined on ITMY. The current state is:

750 mHz in Stage 1 RX and RY
250 mHz in Stage 2 All dofs, and Stage 1 X, Z, RZ
100 mHz on Stage 1 Y

The plot attached shows the latest isolation results (Red is Damped, Blue is Isolated).

We are converging toward a configuration that we should be able to copy/paste on other units.


Otherwise, I was having to turn the loops in the low blend configuration. The "boost" filters were making glitches in the actuators output, tripping the watch dogs. I modified the output compensation filters to filter out the glitches. The turn on/off process is now smooth and do not trip the watchdogs anymore.


Non-image files attached to this report
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 18:52, Wednesday 25 July 2012 (3591)
Optical lever updates
J. Kissel, T. Vo, R. McCarthy

After installing the new QPD.mdl library part and getting the channels reflected onto the the QUAD MEDM screens, we found nonsense coming out after the normalisation step of the signal processing. Here, "nonsense" is defined as 
Input to the normalization:
Pin = -2400
Yin = -2900
SUM = -10700
Output of the normalization:
Pout = Pin / SUM = 2.4e+9 = nonsense
Yout = Yin / SUM = 2.9e+9 = nonsense

Given that this library part is working quite well for the rest of the LIGO world that's using it, it implies that there's something screwy going on with our signal chain.

We then tried turning off the signal input and inserting offsets with small (off order 1), known values to provide simple tests to see if the normalization was functional. With just offsets, the signals make sense. DAH! After a little more head scratching and a few more rounds of guess and check, I realized the difference between the input signals and the offsets I was trying: the raw input signals are negative (which Thomas informs me is expected from the electronics). *ACHOO!*

Inverting the sign in the SEG (input filters), all works great. My guess is that the RCG Saturation Part, which has its limits set to [1e-6,1e12] treats the negative numbers as the lower limit, and divides the signal by 1e-6. (Hence 2400 / 2.4e9 = 1e-6).

An analog signal chain red-herring that led to some interesting discoveries:
We'd suspected initially that there was some high-frequency content saturating the ADC (that made it not visible in EPICS variables). A spectra of the raw segment channels, up to 7 kHz, later revealed no such features.

However, while we still suspected this was true, we dove into the whitening chassis just to better understand the signal chain (since it's the only thing between the QPD and the AA chassis). We discovered that, though originally designed to have one, the ISC whitening board (D1001530), which is internal to the Oplev Whitening Chassis (D1100013), did NOT have its daughter board that fixes the state of the typically-digitally-controlled, switchable-state filter board. Mohana had some extra, and will ship some over night. Once those are in place, we can play around with the whitening and gain to find a good state in which we can leave it.
LHO General
patrick.thomas@LIGO.ORG - posted 18:19, Wednesday 25 July 2012 (3595)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Non-image files attached to this report
H2 SUS
szymon.steplewski@LIGO.ORG - posted 17:32, Wednesday 25 July 2012 (3594)
Exciting ITMY and ETMY suspensions
Today from ~ 3:00 pm to 5:20 pm local time I excited the TOP stage of the Y arm suspensions (first ITMY, then later ETMY) in order to gather peak height data to help with diagonalizing the OSEM sensor readbacks.  Power spectra were recorded with damping at the top stage turned OFF, while an excitation of white noise was simultaneously injected into all 6 degrees of freedom of the top stage.  The XML templates are saved in the suspension directories:


/ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ETMY/SAGL2/2012-07-25_top_actuation_ETMY_4times_power.xml

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ITMY/SAGL2/2012-07-25_top_actuation_test.xml


I also tried to drive the L2 stage of ITMY with damping OFF at the top stage, but failed to get any coherence in this power spectrum measurement.
H1 SEI
hugo.paris@LIGO.ORG - posted 17:01, Wednesday 25 July 2012 (3593)
HAM3 -- In Chamber Testing -- Preparation progress

Dave and I finished installing the models, and MEDM screens, for HAM3. 

I built the HAM3 testing folder arborescence, filled HAM3 matrices and started trying the scripts we will use for the in-chamber testing.

In-field cables arrived today. Richard and his crew started installing them.

HAM3 balancing is planned tomorrow. This balancing will be performed with the BNC outpus of the CPSs' ADE boxes.

LHO General
jeffrey.garcia@LIGO.ORG - posted 16:31, Wednesday 25 July 2012 (3592)
Ops Log
Various activities 
- rebooting of SUS models for QUADs in the morning, another in the afternoon
- Thomas Vo to End-Y station
- noisy work in the LVEA from ~1:00PM - 3:00PM
- leak detecting work in the Optics Lab

H1 SUS
jeffrey.bartlett@LIGO.ORG - posted 16:14, Wednesday 25 July 2012 (3590)
Testing MC3 After Creek Bake
   After creek baking and reassembling H1-MC3, the Lower Blade break off heights did not come back to their pre creek bake values. There was a greater than the 0.5mm vertical tolerance between the four blade tips. We tweaked several suspension adjustments but could not bring the tips into compliance. The best we could get was a maximum of 0.75mm height difference between the blade break offs. All other parameters are well within spec. 

   We ran transfer functions on the M1 level to see if the suspension would perform correctly with the Lower Blade heights a bit off. Jeff K., Andres R., and I looked over the plots and compared H1-MC3 with several other suspensions. H1-MC3 compares favorably with the other HSTS suspensions. It was decided to install the AOSEMs and start Phase 1b testing.       
H1 SUS
jeffrey.bartlett@LIGO.ORG - posted 15:46, Wednesday 25 July 2012 (3589)
Restart X1 Triple Test Stand after replacing cards in IO Chassis
   We continue having problems with Tripleteststand loosing communications with the IO Chassis. Tripleteststand did not recover after power down power up reset. Richard M. replaced cards in the IO Chassis and Jim B. restarted IOP, the x1sushxts27 model, and Burt restored the system from 20120622-x1sushxts27_PR2.snap. The Tripleteststand is up and  appears to be running normally.
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 15:36, Wednesday 25 July 2012 (3587)
Quick recompile, reinstall, restart, and restore of QUAD models
During the QUAD models updates last week, the
/opt/rtcds/userapps/release/sus/common/src/
corner of the userapps repository had not been updated, so we didn't receive Joe Betzwieser's PUM stage fix to the
/opt/rtcds/userapps/release/sus/common/src/CD_STATE_MACHINE.c
bit of c-code that controls the analog and digital filtering interaction between the coil drivers.

In addition to updating that corner before the recompile, I also added two EPICs monitor blocks between the MTRX and normalization steps in the 
/opt/rtcds/userapps/release/isc/common/models/QPD.mdl
library part. This change has been committed to the trunk.

Finally, I made sure to capture the current status of the QUADs (as the ISC team left while trying to lock the cavity this morning), in
/opt/rtcds/userapps/release/sus/h2/burtfiles/itmy/h2susitmy_H2OAT_110725.snap
/opt/rtcds/userapps/release/sus/h2/burtfiles/etmy/h2susetmy_H2OAT_110725.snap

and then turned off the damping loops and master switches, left the latest P and Y offsets the offsets in place, and captured new safe.snap files, which are used here:
/opt/rtcds/userapps/release/sus/h2/burtfiles/itmy/h2susitmy_H2OAT_110725.snap
/opt/rtcds/userapps/release/sus/h2/burtfiles/etmy/h2susetmy_H2OAT_110725.snap
but are actually symbolic links to
/opt/rtcds/userapps/release/sus/h2/burtfiles/etmy/h2susetmy_safe.snap
/opt/rtcds/userapps/release/sus/h2/burtfiles/itmy/h2susitmy_safe.snap

With these two changes in place, I recompiled, reinstalled, restarted, AND restored.

The new epics variables are now visible on the optical lever screen (see attached), and Szymon is confirming whether the L2 drive is now functional.
Images attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 13:28, Wednesday 25 July 2012 - last comment - 10:10, Friday 03 August 2012(3586)
H1 HAM3 HEPI Actutors Attached & Released--IAS says OK! Prt Duex
OK now we have all the HEPI Actuators attached & released at the correct elevation and IAS has signed off on the position.

Elevation & level is 0.1mm below nominal of -250.5mm (wrt LIGO Global) with a +-0.1mm levelness.

Attached is my field notes of the final dial indicator readings and the level survey-enjoy.

Thanks to Mitchell & Jason
Non-image files attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 10:10, Friday 03 August 2012 (3712)
I misspeak above where I say wrt LIGO Global.  The number above, -250.5mm is the LIGO Global elevation corrected to the local leveling field.  The HAM ISI Optical Table is positioned to -252.9mm.  2.4mm is the correction to local level hence the -250.5mm; please pardon the confusion. -H
H1 AOS
jason.oberling@LIGO.ORG - posted 12:54, Wednesday 25 July 2012 (3585)
Initial Alignment of HAM3 ISI
IAS: J. Oberling
SEI: H. Radkins
 
Final alignment checks for the HAM3 ISI have been completed.  The table is currently sitting at:
 

For more information on the alignment process, see my previous alog (3484)

H1 CDS
david.barker@LIGO.ORG - posted 09:05, Wednesday 25 July 2012 (3584)
Tue Maintenance Summary

Summary of tasks performed Tuesday 24th July for H1 and H2:

h2pemey and h2pemeyaux models were changed to move two ACC channels from pemaux to pemey.

Additional HWS slow channels were added to H2EDCU_HWS.ini

New H2 models for h2susitmy, h2susetmy and h2iscey were installed. We verified that ISC EY is communicating over 4km to the SUS ITMY.

H2 DAQ was restarted due to all the above changes.

rsync of h1boot reduced to daily at 05:20 until the epics slow down problem can be resolved.

a new ethercat ethernet cable was ran from the optics lab to the second ecat port on the h1ecatc0 slow controls computer. Software is being installed to convert the ref cav status to an epics channel.

I completed the h1boot /opt/rtcds/userapps/release area. Each subsystem directory here is now a separate SVN working area. It is no longer possible to svn update the entire userapps working area (which has been done accidentally before).

H2 SUS
jeffrey.kissel@LIGO.ORG - posted 01:23, Wednesday 25 July 2012 (3583)
Optical Levers revamped in QUAD model, IPC for P andY added to ITMY
D. Barker, J. Garcia, J. Kissel

At the request of the ISC team (see LHO aLOG), we installed the standard QPD readout scheme,
${userapps}/isc/common/models/QPD.mdl
part into the L3/Test Mass level of the QUAD's generic library part
${userapps}/sus/common/models/QUAD_MASTER.mdl
in order to make the optical lever readout more transparent (because the signals used to be processed inside a bit of c-code). 

In addition, we hooked up the IPC from the alignment signals to the ITM (where they had only been installed in the ETM up to today), inside
${userapps}/sus/h2/models/h2susitmy.mdl

Important notes for others:
- I've filled out the OL2EUL (OpticalLever to EULer) matrix in accordance with Thomas' investigations and LLO's precident. However, there's still a good bit of work to do to get the pitch and yaw singals into some sensible units. For, there's a gain of 1e-6 in the OPLEV PIT and YAW filters, so that the values coming out of the bank are not ridiculously huge. 

- I'm not sure the Saturation or the Divide blocks are functional yet (used in the standard QPD block). With no 1e-6 gain, merely taking (S1+S3)-(S2+S4) shows values of order 1e10 to 1e11. Last I checked [(~4000 + ~4000) - (~4000 + 4000)] / (~4000) was of order 1.

- Adding the inter-process communication between ISC and the ITM required adding the appropriate IPC channels to the h2iscey.mdl, which I compiled, but did NOT install or restart. I'll leave that up to the discretion of others.


Details
-------
Simulink Model Work:
In todays work, we modified (and svn committed)

${userapps}/sus/common/models/QUAD_MASTER.mdl
${userapps}/sus/h2/models/h2susitmy.mdl
${userapps}/sus/h2/models/h2susetmy.mdl
${userapps}/isc/h2/models/h2iscey.mdl


During the compilation process, the RCG threw us a few curve balls just to keep us on our toes: 
- As one passes a signal down into sub-blocks -- even though Simulink allows it -- the input and output bubbles can't be named the same thing or else the compiler throws an error claiming the blocks involved are not connected. The assumption is that the parser collects the first instance of the input/output bubble name, makes the appropriate connection, but then skips all other instances with the same name, therefore "not connecting" it. 
- If you add "receiver" IPC parts, you have to name it a full channel name and that channel name has to match one in the IPC list,

/opt/rtcds/lho/h2/chans/ipc/H2.ipc

which is generated by the sender models during *their* compilation process. If you put an non-existing channel name in there, the compiler throws and error claiming that there're unexpected characters found before character ";" on lines (x,y,z), because instead of barfing that the channel doesn't exist, it merely fills in nothing, so you end up with a "channel = ;" sort of thing in the resulting code.

We've removed the optical lever power monitor from the master model, which prior-to-this-update was taken and used by the c-code. With the c-code gone, that monitor singal is no longer needed. It should be readout by someone eventually though. Perhaps we'll still it in with the monitor models eventually.

Because we're stuck with whatever names the filter blocks have in the QPD.mdl libary part, we had to change the stored optical lever framebuilder channels to

$(IFO):SUS-$(OPTIC)_L3_OPLEV_PIT_OUT_DQ    2048
$(IFO):SUS-$(OPTIC)_L3_OPLEV_YAW_OUT_DQ    2048
$(IFO):SUS-$(OPTIC)_L3_OPLEV_SUM_OUT_DQ    256

(and note that we also can't have L3_OPLEVINF's any more. These filters are now named L3_OPLEV_SEG[1,2,3,4]). The goal is to have these be the channels which are calibrated into physical units.

Added optical lever chain to 

${userapps}/sus/common/medm/quad/SUS_CUST_QUAD_OVERVIEW.adl

and created a few new screens

${userapps}/sus/common/medm/quad/SUS_CUST_QUAD_L3_OPLEV.adl
${userapps}/sus/common/medm/quad/SUS_CUST_QUAD_L3_OPLEV_SEGS.adl
${userapps}/sus/common/medm/quad/SUS_CUST_QUAD_L3_OPLEV_MTRX.adl

which are shown in the attached screenshots.
Images attached to this report
H2 ISC
bram.slagmolen@LIGO.ORG - posted 21:58, Tuesday 24 July 2012 (3581)
Arm Locking

After all the succes of the RefCav and the PLL, we managed to restore the cavity alignement. We had to do some serious beam steering (with the ITM we steered the beam on either side and top and bottom of the ETM to centre the beam). Once we had some locking going out tdsdither script walked us to the top.

Engaging the PDH (CMB-B) servo initially it seemed to lock ok, but then the servo output started to oscillate between +/-10V. All gains seem ok (we even increased the input from -14 to -10 dB), with a 'UGF' of 11 kHz.

With this oscillation (at the limit), we were seeing the power fluctuations on the REFL_PWR_MON. I left the arm cavity unlocked, but kept the PLL going.

On another note, we did find the moment to align the WFS, so when we get the oscillaitons under control we can get the WFS going ...

H2 ISC
bram.slagmolen@LIGO.ORG - posted 21:48, Tuesday 24 July 2012 (3580)
Good ISC/SUS epics settings

If one wants to restore to a 'good' epics state for the ISC and SUS (I/ETMY) at LHO, local time of 1800h 24 July 2012 is good. It has the various gains correct and ITM and ETM offset so there is a resonance for locking. The PLL will be on, but the PDH servo is off.

Although the ISI was working as well, I think that Frabrice has made soem changes since.

H2 AOS
fabrice.matichard@LIGO.ORG - posted 19:25, Tuesday 24 July 2012 (3579)
Stage 1 Blend lowered to 100 mHz
A new low blend has been designed and installed on ITMY, Stage 1, longitudinal.

The plot attached shows the improvement on the stages motion. The red curve is the reference (Damped), Blue curve is a measurement with a 250 mHZ blend, green curve is the measurement with the 100 mHz Blend.

L4Cs are the in loop sensors and show a very nice suppression.

T240s are out of loop and also show good suppression, though not as good as the L4Cs. We'll investigate why (sensor noise, misalignment...)

GS13s show some suppression, but less than on Stage1. To be investigated as well.

Non-image files attached to this report
H2 ISC
alberto.stochino@LIGO.ORG - posted 18:47, Tuesday 24 July 2012 - last comment - 23:24, Tuesday 24 July 2012(3575)
Reference cavity locked with different settings

[Alberto, Bram]

Today we locked  the reference cavity with some optimized settings. We set the knobs in the TTFSS with these values:

COARSE: 690; FINE: 610; COMM: 988; FAST 520; OFFSET 294.

The laser temperature diplay read: 41.064 degrees.

We measured a UGF of 172 kHz.

Two peaks appeared initially in the loop gain measurements at about 2.4 Hz and 4 Hz. We found  that the first was due to the cleam room HEPA filters and the second one was the cavity motion due to us touching the table.

Comments related to this report
bram.slagmolen@LIGO.ORG - 23:24, Tuesday 24 July 2012 (3582)

I measured the transmitted beam of the RefCav which is monitored by a thorlabs PD (also it hits a Watec CCD, and of course into the fiber). the PD is in Beckhoff world and will soom be available in EPICS. At the moment we have an EVO stream of the TV and oscilloscope!

Attached are three plots, the first two with the same frequency span ~0.05 Hz to 50 Hz and the third plot from ~100 Hz to 112kHz. All recorded with an SR785.

The first plot is the transmitted power readout form the Thorlabs PD, with the HEPA filters ON and OFF. There is a reduction of 2 of the 2.75 Hz peak as well as no harmonics. There is a 4 Hz spike appearing. You can see the beam jiggling on the TV monitor.

The second plot is the TTFSS mixer output (on the interface chassis), indicating that these spikes are not seen in reflection.

The third plot is a large frequecy span, of both the transmission PD and the TTFSS mixer output. There are spikes visible which are not in each others signals.

In summary, if we get the cavity locking again, then the 2.75 Hz peak should be smaller with 'no' harmonics. Although a 4 Hz peak will appear ...

The fourth file is a zip of the data and matlab script for the interested ones.

Images attached to this comment
H1 SUS
betsy.weaver@LIGO.ORG - posted 16:38, Monday 23 July 2012 - last comment - 19:12, Tuesday 24 July 2012(3545)
More MC2 Phase 2b testing

This afternoon we obtained the spectra of the lower stages (M2 and M3) of MC2 in both the damped and undamped states (using plothsts_spectra.m).  The spectra were taken over the lunch hour so the LVEA activity should have been pretty quiet.  Data was committed to svn.  WIll post a PDF shortly.

As well, I used awggui to try to verify that I could see drive on the coils of these lower stages (for example, exc H1:SUS-MC2_M2_COILOUTF_UL_EXC while watching the OSEMINF_OUT_DQ channel for UL).  This will need to continue later as at first pass, I couldn't see much signal on the M2 AOSEMs.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 08:53, Tuesday 24 July 2012 (3559)
More details / results to come, but I figured we'd post the results for people to independently peruse, while we continue to discuss.

Conclusions at this point:
 - The top to top (undamped) transfer functions look mostly excellent
 - The only thing that has raised a yellowish flag is the first longitudinal mode at 0.68 Hz shows a sharp notch just above it in frequency. Given that the rest of the magnitude looks entirely clean (and independently looking at the DTT .xmls confirming good coherence), I'm confident it's a real feature. However -- after exploring the model in detail we (re)remembered that the first L mode is at the exact same frequency as the first T mode. So, perhaps, in this particular instance the two modes are just different enough to break the normally degenerate mode.
 - Spectra look as expected given the out-of-vacuum environment. The results are notably and encouragingly *less* noisy at high frequency, confirming that the surprisingly large excess motion at high frequency seen in this SUS's Phase 1b results was merely excessive ambient noise in the X1 Test Arena.

To come:
- Damped transfer functions (results taken, just not yet analyzed)
- TF comparisons with other, previous results
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 19:12, Tuesday 24 July 2012 (3576)
Status Update:

I attach new versions of the above plots, which now includes the 2012-07-20, damping-loops-closed transfer functions compared against MC2's phase 1b measurement (2012-06-15) and a token L1 HSTS (L1 SUS MC1, 2012-06-04). The conclusions are still the same; everything looks pretty darn good, except for the non-degeneracy of the first Longitudinal and first Transverse mode. Note that the non-degeneracy disappears with damping loops on, so the loops are modifying the dynamics enough that there is no further "cross-coupling" (if indeed it is a mechanical/physical cross-coupling and not just sensor cross-coupling from not-perfectly-aligned-flags or something).

HOWEVER, after looking into the assembly tolerance for Roll, we found that, as currently constructed, MC2 is out of spec. So, Betsy and Travis will need to adjust the Roll of the optic (on Thursday), and therefore all measurements will have to be re-done, since it's a major change that would affect the dynamics. (Booooo.)

Thinking out loud: Hrmm... if the Roll is out of spec ... Roll is fundamentally coupled with Transverse ... maybe the roll in the optic is modifying (increasing? decreasing? the frequency -- can't tell) the first Transverse / Roll mode of the SUS, breaking the above mentioned degeneracy ... maybe this is why it's obvious in this SUS and not any SUS's prior? But this still doesn't explain how a L / P drive could produce R / T, which should be completely orthogonal degrees of freedom.
Non-image files attached to this comment