Displaying reports 85281-85300 of 88617.Go to page Start 4261 4262 4263 4264 4265 4266 4267 4268 4269 End
Reports until 21:40, Thursday 12 July 2012
H1 SUS
betsy.weaver@LIGO.ORG - posted 21:40, Thursday 12 July 2012 (3432)
PR2 SUS moved to chamber side table

Today, Travis, Andres, and Jeff hoisted the PR2 SUS out of the storage container and placed it onto the chamber side table.  We'll work towards getting it connected to electronics and resuspend the all metal masses likely next week.

H1 SUS
betsy.weaver@LIGO.ORG - posted 21:21, Thursday 12 July 2012 (3427)
IMCC-02 officially becomes HAM3 MC2

Today, I packed up and transported the fully outfitted IMCC optic to the HAM chamberside install area.  It took all 4 of us (Jeff, Travis, Andres, and I) to get it into the suspension and suspended as a single stage. At first glance however, it seems to have only minor pitch error which is a relief. We finished resecuring the optic with EQ stops and face covers and left it under its C3 tent for the night.  We'll still need to finish suspending and tweeking alignment before taking TFs.

X1 SEI
hugo.paris@LIGO.ORG - posted 21:05, Thursday 12 July 2012 (3431)
Monitoring Temperature in Staging Building

In order to assess the effect of recent temperature changes on our testing, I installed 2 Lascar Temperature/Humidity data-loggers in the staging building:

#1 Is inside a cleanroom. I set it on the West SEI test stand (currently used for the testing of HAM-ISI Unit #6). Pic.1
#2 Is outside the cleanrooms, against the south wall, behind the East SEI test stand (currently used for the assebly of HAM-ISI Unit #7). Pic.2,3

 

Setup for the Data-Loggers:

Note: Loggers' data is collected with a Windows-only software. This software is available on the solidworks station.

 

 

Thanks to SUS for letting us borrow the loggers from them.

Images attached to this report
H1 ISC
matthew.evans@LIGO.ORG - posted 19:42, Thursday 12 July 2012 (3430)
OAT - calibrated spectra (up to 500Hz)

The noise above 200Hz is probably frequency noise from the fiber link which carries the stabilized beam from the corner station (see T0900376).  The broadband floor to the frequency noise is about 1Hz/rtHz, with acoustic peaks from ~50Hz up that reach ~30Hz/rtHz.  This will translate to a flor around 15pm/rtHz in the arm cavity spectrum (see entry 3413, and the ALS wiki page).

Images attached to this report
H2 AOS
thomas.vo@LIGO.ORG - posted 19:36, Thursday 12 July 2012 (3428)
H2 ETMY Optical Lever Install Update
Thomas Vo Scott(Apollo) Matt Evans


By offsetting the pitch and yaw test filters on the M0 stage we can see the optical lever beam move in pitch and yaw respectively.  For a sanity check, I also independently put an offset on the reaction mass test filters and this did not affect the optical lever beams so I'm sure that we are not seeing another ghost beam off the reaction mass.

BUT!!!

One thing I noticed is that there is another beam close to our currently aligned beam, approximately 3 cm away.  After looking up some specs for the test mass depth (~34cm) and the gap between the reaction mass (~5mm), Matt and I did some calculations and it looks like the beam that we are currently aligning to is the reflection off the back surface which will give you the same transfer function results as a front surface reflection.  Looking at the reflectivity/transmission data for the ETMy shows that the primary reflection off the front surface is comparable to the secondary reflection off the back surface so it is difficult to judge by eye which one is which.  These calculations will be needed in future installs for correct alignment. For optical levers with large lever arms such as ITMy (optical path ~ 60 meters), the wedge will play a significant role in determining the correct beam as well.

The solution is to go back and open up the enclosures to do yet another re-alignment to look for the correct beam off the front, that would require a soft close of the gate valve.  The reflection off the back surface will still be able to give pitch and yaw, unless the other beam encroaches on the photodetector.  
LHO General
patrick.thomas@LIGO.ORG - posted 18:45, Thursday 12 July 2012 (3426)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot. I have included a plot of the mode of the dust monitor at location 15 in the LVEA (H0:PEM-LVEA_DST15_MODE) to show when the communication to it was lost.
Non-image files attached to this report
H1 SEI
greg.grabeel@LIGO.ORG - posted 17:30, Thursday 12 July 2012 (3425)
HAM6 Shipping Container Nitrogen Purge
Attached is the accumulated data of the LN2 purge on the HAM6 shipping container. At this point bumping the flow rate up to ~20 L/m has encouraged the dew point to continue to drop. After the dewar ran empty yesterday it has since been refilled, hooked back up, and data logging continues.
Images attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 17:02, Thursday 12 July 2012 (3424)
H1 HAM3 HEPI Work
Greg Jim & Hugh
We tweaked the position again per IAS (Jason) and then set to attaching HEPI Actuators.  We ended up behind where we started when we found we were unable to attach the Actuator on the NW corner.  We had to jack up the Crossbeam and slide the HEPI Housing East.  This gets quite involved and we are now out of position again based on the Dial Indicators.  We'll continue with attachment and may request looks by IAS as we go.
LHO General
michael.rodruck@LIGO.ORG - posted 16:12, Thursday 12 July 2012 (3423)
Ops summary
Images attached to this report
H2 TCS
eleanor.king@LIGO.ORG - posted 15:03, Thursday 12 July 2012 - last comment - 19:39, Thursday 12 July 2012(3422)
Ring heater test

The ring heater was turned on today to check whether running the ring heater had an effect on the vacuum pressure.   15W of power was put through each segment of the ring heater at 19:07:30 UTC until 19:37:08 UTC (by adding an offset of 25,000 counts to H2TCSETMY _EMTY_RING_HTR_SEG1_DC_I_SET and H2TCSETMY_ETMY_RING_HTR_SEG2_DC_I_SET), which is close to the maximum ouput of the ring heater.  The vacuum in BSC6 was not affected by running the ring heater, which is good.

 

I added in gains to the ring heater input and readout channels so that the we can input the current in amps and readout the voltage and ring current on volts and amps instead of counts (reffering to D1002529 for  the required conversion factors).

Comments related to this report
thomas.vo@LIGO.ORG - 19:39, Thursday 12 July 2012 (3429)
Just a note, the temperature sensors are in fact broken on these ring heater segments, the attached image shows the signals railed for the sensors.
Images attached to this comment
LHO VE
kyle.ryan@LIGO.ORG - posted 14:57, Thursday 12 July 2012 (3421)
Opened GV18


			
			
H1 ISC
alberto.stochino@LIGO.ORG - posted 14:06, Thursday 12 July 2012 - last comment - 09:45, Thursday 19 July 2012(3420)
TMS ISC Table Stability

I measured the TMS ISC table angular and lateral stability when the end station VEA was quiet last night.

I found the table displacement to be around 5-10 um rms laterally and 1-3 urad rms in angle over 100s. The motion thus appears to be within the requirements: 100 um and 1 urad, respectively.

See attached plots. The bump below 1 Hz is probably due to the table's roll mode. A peak shows up at about 8 Hz due to the table enclosure: opening the table's doors reduced its amplitude.
 
The measurement was done with the PZT loops closed. These loops use the TMS green QPD error signals and have a UGF of about 8 Hz. I then calibrated the PZT control signals according to the manufacturer's specs and used the ABCD matrix of the beam path from the PZT onwards on the ALS table (see attached drawings for the optical details). Fianlly I compensated for the loop gain.
 
Initially the spectrum looked mostly flat up to 10 Hz, masking any features of the TMS table motion. After checking for several causes, eventually turning off the HEPA filters in the ALS table as Bram suggested, solved the problem. The airflow due to the HEPA filters was shaking the PZTs and the other optics on the table. This shouldn't be a problem during science mode, when the filters are meant to stay off. The plot attached shows a comaprison of the PZT control signal spectra with the HEPA filters ON (reference traces) and OFF.
 
Data and matlab code code are in the svn: /svn/cdsutils/trunk/ALS/TMS_stability 
I found the table displacement to be around 5-10 um rms laterally and 1-3 urad rms in angle over 100s. The motion thus appear to be within the requirements: 100 um and 1 urad, respectively. See attached plots.
 
The bump below 1 Hz is probably due to the table's roll mode. A peak shows up at about 8 Hz due to the table enclosure: opening the table doors reduced the amplitude.
 
The measurement was done with the PZT loops closed. These loops use the TMS green QPD error signals and have a UGF of about 8 Hz. I then calibrated the PZT control signals according to the manufacturer's specs and used the ABCD matrix of the beam path from the PZT onwards on the ALS table (see attached drawings for the optical details).
 
Initially the spectrum looked mostly flat up to 10 Hz, masking any features of the TMS table motion. After checking for several causes, eventually turning off the HEPA filters in the ALS table as Bram suggested, solved the problem. The intense airflow due to the filters was shaking the PZT and the other optics on the table. This shouldn't be a problem during science mode, when the filters are off.
I measured the TMS table angular and lateral stability when the end station VEA was quiet.
I found the table displacement to be around 5-10 um rms laterally and 1-3 urad rms in angle over 100s. The motion thus appear to be within the requirements: 100 um and 1 urad, respectively. See attached plots.
 
The bump below 1 Hz is probably due to the table's roll mode. A peak shows up at about 8 Hz due to the table enclosure: opening the table doors reduced the amplitude.
 
The measurement was done with the PZT loops closed. These loops use the TMS green QPD error signals and have a UGF of about 8 Hz. I then calibrated the PZT control signals according to the manufacturer's specs and used the ABCD matrix of the beam path from the PZT onwards on the ALS table (see attached drawings for the optical details).
 
Initially the spectrum looked mostly flat up to 10 Hz, masking any features of the TMS table motion. After checking for several causes, eventually turning off the HEPA filters in the ALS table as Bram suggested, solved the problem. The intense airflow due to the filters was shaking the PZT and the other optics on the table. This shouldn't be a problem during science mode, when the filters are off.
I measured the TMS table angular and lateral stability when the end station VEA was quiet.
I found the table displacement to be around 5-10 um rms laterally and 1-3 urad rms in angle over 100s. The motion thus appear to be within the requirements: 100 um and 1 urad, respectively. See attached plots.
 
The bump below 1 Hz is probably due to the table's roll mode. A peak shows up at about 8 Hz due to the table enclosure: opening the table doors reduced the amplitude.
 
The measurement was done with the PZT loops closed. These loops use the TMS green QPD error signals and have a UGF of about 8 Hz. I then calibrated the PZT control signals according to the manufacturer's specs and used the ABCD matrix of the beam path from the PZT onwards on the ALS table (see attached drawings for the optical details).
 
Initially the spectrum looked mostly flat up to 10 Hz, masking any features of the TMS table motion. After checking for several causes, eventually turning off the HEPA filters in the ALS table as Bram suggested, solved the problem. The intense airflow due to the filters was shaking the PZT and the other optics on the table. This shouldn't be a problem during science mode, when the filters are off.
I measured the TMS table angular and lateral stability when the end station VEA was quiet.
I found the table displacement to be around 5-10 um rms laterally and 1-3 urad rms in angle over 100s. The motion thus appear to be within the requirements: 100 um and 1 urad, respectively. See attached plots.
 
The bump below 1 Hz is probably due to the table's roll mode. A peak shows up at about 8 Hz due to the table enclosure: opening the table doors reduced the amplitude.
 
The measurement was done with the PZT loops closed. These loops use the TMS green QPD error signals and have a UGF of about 8 Hz. I then calibrated the PZT control signals according to the manufacturer's specs and used the ABCD matrix of the beam path from the PZT onwards on the ALS table (see attached drawings for the optical details).
 
Initially the spectrum looked mostly flat up to 10 Hz, masking any features of the TMS table motion. After checking for several causes, eventually turning off the HEPA filters in the ALS table as Bram suggested, solved the problem. The intense airflow due to the filters was shaking the PZT and the other optics on the table. This shouldn't be a problem during science mode, when the filters are off.
I measured the TMS table angular and lateral stability when the end station VEA was quiet.
I found the table displacement to be around 5-10 um rms laterally and 1-3 urad rms in angle over 100s. The motion thus appear to be within the requirements: 100 um and 1 urad, respectively. See attached plots.
 
The bump below 1 Hz is probably due to the table's roll mode. A peak shows up at about 8 Hz due to the table enclosure: opening the table doors reduced the amplitude.
 
The measurement was done with the PZT loops closed. These loops use the TMS green QPD error signals and have a UGF of about 8 Hz. I then calibrated the PZT control signals according to the manufacturer's specs and used the ABCD matrix of the beam path from the PZT onwards on the ALS table (see attached drawings for the optical details).
 
Initially the spectrum looked mostly flat up to 10 Hz, masking any features of the TMS table motion. After checking for several causes, eventually turning off the HEPA filters in the ALS table as Bram suggested, solved the problem. The intense airflow due to the filters was shaking the PZT and the other optics on the table. This shouldn't be a problem during science mode, when the filters are off.
Initially the spectrum looked mostly flat up to 10 Hz, masking any features of the TMS table motion. After checking for several causes, eventually turning off the HEPA filters in the ALS table as Bram suggested, solved the problem. The intense airflow due to the filters was shaking the PZT and the other optics on the table. This shouldn't be a problem during science mode, when the filters are off.Initially the spectrum looked mostly flat up to 10 Hz, masking any features of the TMS table motion. After checking for several causes, eventually turning off the HEPA filters in the ALS table as Bram suggested, solved the problem. The intense airflow due to the filters was shaking the PZT and the other optics on the table. This shouldn't be a problem during science mode, when the filters are off.
Non-image files attached to this report
Comments related to this report
alberto.stochino@LIGO.ORG - 06:49, Thursday 19 July 2012 (3494)

These are the close loop plots of the same measurements.

Non-image files attached to this comment
alberto.stochino@LIGO.ORG - 09:45, Thursday 19 July 2012 (3498)

As Keita noted, the HEPA-off curves show a large bump at around 100mHz which which goes above spectra with the HEPA on. It's not clear why.

H2 TCS
eleanor.king@LIGO.ORG - posted 13:52, Thursday 12 July 2012 (3404)
Hartmann sensor imaging of the ETM

I've aligned the Hartmann plate onto the conjugate image plane of the ETM.  This was done by yawing the ETM periodically (excitation of H2:SUS-ETMY_M0_TEST_Y_EXC at 0.25Hz and 200 counts) and measuring the amount of motion of the beam spot on the CCD with the Hartmann plate removed.  Using DTT I obtained a transfer function of spot movement on the CCD over the yaw in the ETM (H2:TCS-HWS_ETMY_ITMM_CENTER_X/H2:SUS-ETMY_L1_WIT_YMON).    I moved the lens F1 along the beam path to find the position where the transfer function was zero, at which point the HWS CCD is at the image plane of the ETM.  Attached is a graph of the transfer function versus the position of F1.

The HWS was then moved back 11mm (see second attachment) so that the Hartmann plate rather than the CCD is located at the ETM image plane.  The Hartmann plate has been reattached.  The next step is to look at the quiescent prism and defocus of the beam on the HWS.  

Images attached to this report
Non-image files attached to this report
H2 CDS
david.barker@LIGO.ORG - posted 09:13, Thursday 12 July 2012 (3416)
backups of h2boot causing EPICS slowdowns on all H2 front ends

Starting last thursday, 5th July, the backups of h2boot by the disk-to-disk backup server cdsfs1 causes a significant slowdown of all H2 front end EPICS systems. It is most noticable on MEDM screens, where the refresh rate drops to several seconds. Once the backup is completed (after about 15 minutes) the systems immediately recover. I am unable to reproduce the error on H1 or on the DTS test stand. I'll reboot h2boot at the next opportunity as part of the investigation. No significant change to the h2boot file system occured late last week (most of us were on vacation).

For now the backup of h2boot's perioicity has been reduced from every 4 hours to daily at 05:41 until the problem can be resolved.

H1 PSL
michael.rodruck@LIGO.ORG - posted 09:12, Thursday 12 July 2012 (3415)
PSL plots

35W beam. The ISS gain was changed from -2.1 to 7dB which seemed to quiet the noise at high frequencies.

Images attached to this report
Non-image files attached to this report
H2 AOS
thomas.vo@LIGO.ORG - posted 21:27, Wednesday 11 July 2012 - last comment - 11:50, Thursday 12 July 2012(3414)
Enclosure Installation Update
Thomas V. Mark D.(Apollo) John W. Gerardo M.

We have finished installing the enclosures for ITMY and ETMY.  During installation, ETMY was misaligned and I mistakenly re-aligned to the reaction mass ghost beam, will fix to reflect off the ETM. ITMY is fully operational, some internal focusing of the telescope may need to take place since the beam diameter is approximately 8 mm, spec calls for 2-3 mm.  However, it is up to the commissioners of the OAT whether or not this adjustment is worth doing.

Deviations from design:

1) Due to the tightness between the ITMY transmitter pier and the viewport, we were only able to get the viewport protector in between them and couple the enclosure to the protector via sheet metal and tape.

2) It was also pretty tight between the viewport protector and the enclosure on the ETMY receiver pier, we were not able to fit a full sized bellow to couple the connection between the two.  We ended up cutting the bellow to a smaller size and using that.  Also, we adjusted the level of the receiver pier in order to not have the enclosure touch the beam tube (the corner of the enclosure was butting up against the side before).


Images attached to this report
Comments related to this report
peter.fritschel@LIGO.ORG - 11:50, Thursday 12 July 2012 (3418)

Editorial note:

I assume this entry refers to the enclosures around the optical lever beams for ITMY and ETMY, though nowhere in the entry is the term 'optical lever' (or any of its derivatives) found. This makes the entry rather abstruse, and it also means that if one searched the log for optical levers, oplevs, optlevs, etc, one would not find this record.

Technical note:

If the design calls for the beam size to be adjusted to be 2-3 mm (radius? diameter?) on the detector, it should be adjusted to that. The optical lever isn't really considered to be installed until that is true.

H1 ISC
matthew.evans@LIGO.ORG - posted 19:46, Wednesday 11 July 2012 - last comment - 13:48, Thursday 12 July 2012(3413)
OAT - new calibrated spectra

For the evening shift, we set out to check the VCO calibration, and get some new calibrated spectra.  This work starts where entry 3400 left off...

After relocking the cavity we found that he SR560 path (which was described in 3400 as having a gain of 10 at the SR560, and another gain of 10 at the TTIF) saturated due to low frequency motion (below 1Hz).  With a gain of 1 on the SR560 it worked, and the 2 signal paths (SR560 and FMON) showed essentially perfect coherence.  This also showed that the FMON calibration is not -20dB at DC and 20dB at HF, but rather 0dB at DC and 40dB at HF (see comment to 3400).  With this direct measurement of FMON in hand, we removed the SR560 path.

Discussions with Bram brought out a missing factor of 2 in my previous calculation: since the PLL is in the 1064nm output of the laser, and we are using the 532 for locking, we get twice as much frequency change in the light seen by the cavity as the light seen by the PLL.  (The same result can be achieved by ignoring the fact that green light is used at all, such that the conversion from frequency to length becomes L_cavity / f_laser = 3995m 1064e-9m / 3e8m/s = 14.2pm/Hz.)

In summary:

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 09:43, Thursday 12 July 2012 (3417)

614pm/count using VCO, which is awesome. 0.8nm/count using OSEM, which is 30% off of the above.

Yet people keep saying that OSEM calibration should be fine at 20% level.

keita.kawabe@LIGO.ORG - 13:48, Thursday 12 July 2012 (3419)

For people outside of the ISC:

1. Frequency offset between the refcav in the corner station lab and the EY ALS red beam is kept at the VCO frequency by a PLL loop.

2. Transfer function from VCO frequency to the red laser frequency is equal to G_PLL/(1+G_PLL) where G_PLL is the OLTF of PLL. Since UGF of G_PLL is about 20kHz, this is almost equal to 1 for f<1 kHz or so.

3. Electronics transfer function from VCO tuning input to the frequency of the VCO was measured to be H_VCO=139kHz/Volt *pole(1.6Hz)*zero(40Hz).

4. The green laser is the second harmonic of the red, therefore the transfer function from VCO tuning input to the green frequency is 2*H_VCO.

5. To lock the laser to the arm, we control the frequency of the green laser by feeding PDH signal via CM board back to VCO tuning input.

6. When the laser is locked to the arm, VCO input is equal to

v= (1+G_PDH)/G_PDH / (2*H_VCO) * df

where G_PDH is the OLTF of PDH loop and df is the equivalent frequency fluctuatoin of the cavity length, refcav and pll loop noise combined.

Since UGF of G_PDH UGF is 8kHz or so, again (1+G_PDH)/G_PDH is almost 1 for f<1kHz or so, therefore

v ~ df/(2*V_VCO)

7. Frequency to length conversion is 4000m/  563.5THz (green light).

8. PDH CM board output is connected to PDH FMON channel, which has the transfer function of 2^15 counts/10 volt * zero(10, 10)*pole(100, 100).

Therefore, all in all, VCO input measured by FMON is calibrated back to length using

dL = FMON / (2^15 cts/10 V) *pole(10;10) * zero(100, 100) * 2*H_VCO * 4000m/563.5THz

  = 602 pm/cts * FMON *pole(1.6;10;10) * zero(40;100;100).

Small difference in number (Matt's is 614 pm/V) came from the fact that I used 2^15/10 cts/Volt for ADC while Matt used the ADC calibration he did with his table top diode box as an amplifier.

Displaying reports 85281-85300 of 88617.Go to page Start 4261 4262 4263 4264 4265 4266 4267 4268 4269 End