Filiberto will be disconnecting external ISI cables from their respective feedthrus to help Kyle with his leak-checking work of BSC8. Cables will be re-connected when Kyle gives the ok.
During phase I and II, the ISIs are tested in clean rooms and are subjected to an important airflow disturbance. Consequently, it is quite difficult to have good quality measurements at high frequencies (100Hz to 1KHz). To improve the quality of the transfer functions, we can split the high frequencies transfer functions measurements into multiple frequency bands but the “quick high frequency transfer functions measurements” become time consuming.
Measurement limitations:
- at HF, the drive is the limit
- at LF, the drive is small and the sensors saturate easily
To reduce the measurement time, we can drive 1 DOF at low frequency and different DOF at high frequency simultaneously. During a test, stage 1 was driven at low frequency while Stage 2 was driven at high frequencies. In the attached plots, there is a comparison when the TFs are measured by exciting one DOF at the time and 2 DOFs simultaneously. It matches. Only, a light difference is observed on the 2 first resonances of the ISI (probablydue to a light change of the plant between the two measurements)
HEPI transfer functions
The first set of transfer functions was measured on BSC8 from 2mHz to 500Hz. The 700mHz-10Hz frequency band was measured in 2 configurations:
- ISI undamped (2012_02_15)
- ISI damped (2012_02_16)
The HEPI transfer functions can be seen at:
- LHO_HEPI_BSC8_TF_L2L_Raw_from_ACT_to_IPS_2012_02_16.fig
- LHO_HEPI_BSC8_TF_L2L_Raw_from_ACT_to_IPS_2012_02_16.pdf
- LHO_HEPI_BSC8_TF_L2L_Raw_from_ACT_to_L4C_2012_02_16.fig
- LHO_HEPI_BSC8_TF_L2L_Raw_from_ACT_to_L4C_2012_02_16.pdf
The ISI damping loops are effective between 1Hz and 8Hz. The effect on HEPI transfer functions is limited but visible on the 1.25Hz and 5 Hz resonances. A comparison between the two configuration can be found at:
- LHO_ISI_BSC8_Comparison_TF_L2L_ACT_H_to_L4C_H_20120215_vs_20120216.fig
- LHO_ISI_BSC8_Comparison_TF_L2L_ACT_H_to_L4C_H_20120215_vs_20120216.pdf
- LHO_ISI_BSC8_Comparison_TF_L2L_ACT_V_to_L4C_V_20120215_vs_20120216.fig
- LHO_ISI_BSC8_Comparison_TF_L2L_ACT_V_to_L4C_V_20120215_vs_20120216.pdf
If you look carefully, you can see light bumps at the junctions between the different sections (10mHz for instance) of the transfer functions. To evaluate the non linearity, I drove a sine wave at 200mHz and 4Hz using different amplitudes (100cts, 300cts, 1000cts, 3000cts, 5000cts) (attachment).
Low gain on the HEPI pier interface D080521
It is quite surprising to see that the HEPI L4C signals don’t overshoot +/-100 counts on the ADC (attachment 1) when the actuators are not driven. After checking that all elements of the readout chain were turned on, we measured the L4C gain of one HEPI pier interface D080521. The gain is 22 and a 0.1V input offset gives 3600counts on the ADC as expected.
After comparing calibrated spectra of the HEPI L4Cs (on top of the piers) with spectra of the ISI L4Cs (stage 1), the HEPI L4Cs spectra don’t look wrong.
L4C gain in D080521 seems low.
The default NDS server assignment that is made for new shells has been changed to use h2nds0 instead of h2nds1. This will affect any program or shell started after 10:38 AM PST on Feb. 17, 2012.
Attached are plots of dust counts > .5 microns for February 15 and 16.
Kyle, Gerardo, John Had valved-out QDP80 pump from YBM before leaving last night. YBM pressure was 20 torr at that time. Pressure rose to 200 torr in ~18 hours, i.e. large unexplained gas load in YBM volume -> Resumed pumping YBM with QDP80 this morning. Pumped adjacent annulus volumes (BSC8, GV1 and GV3-GV5 already under vacuum). Connected leak detector in parallel with QDP80 pump path and set detector up for high pressure leak testing (10 torr max inlet pressure). Once YBM pressure reached 10 torr, Gerardo and I did a "rehearsal" exercise by spraying some feed-throughs on BSC8 -> Noticed a large delayed response after tens of seconds. Time constant believed to be around 1800 seconds for these conditions. Signal continued to rise for ~30 minutes after initial (10 sec/flange dwells) until signal "railed" the leak detector at 9.9 x 10-4 torr*L/sec. -> Surprisingly, Gerardo was unable to find this "wopper" leak by utilizing the stethoscope! We probably could hear this leak with our unaided ear if there wasn't so much background noise in the LVEA. -> For tonight, I am leaving the YBM vent/purge valve "cracked" open a little so as to keep a viscous stream flowing in the correct direction in the event of a QDP80 stoppage during the night. This way we won't have to valve-out the pump overnight and we can resume leak testing in the morning without having to wait "hours" to get back to 10 torr.
PSL is shut off for the night to allow Robert S. to make accelerometer measurements on the periscope, without interference from the chilled water lines. PMC, ISS, FSS servos are off, everything will be started back up tomorrow morning.
HEPA units are off, make up air is set to 30%, creating a ~0.01" water pressure differential between laser and anteroom. AC units were shut off via touchpad interface, but they may still be on.
Laser is back up
Today we installed the fall protection wire and temporary vertical protection bars for the TMS isc table, and removed the Genie, while the cube is still on EQ stops. It went fine.
Originally the temporary protection bars weren't required at this stage, however the new initial alignment procedure the TMS and the intial alignment people have been working on requires that a large target is mounted on the input aperture of the telescope plate. Since this totally changes the balance of the TMS/tele, we needed temporary EQ stops on the vertical protection bars.
Photo 1: It was difficult to attach our preferred cable into the bottom QPD bracket on the transmon table. (This is for the green QPDs, we think.) We removed the unconnected pins but this didn't help; in the end we switched the cables and things worked ok. (We preferred to use the cable with more slack for the lower connection, but c'est la guerre.) Now, the cable arrangement is (photos 2-5): Top QPD connector (red QPDs): S1104109 Bottom QPD connector (green QPDs): S1104468 Top ETM-side connector (picomotors): S1104116 Bottom ETM-side connector (IR beam diverter): S1104114 These numbers don't matter much in the long run, other than we will take care to plug the other end of the cables into the proper ISC connector on the bracket on the ISI table. (And then check that the ISC cables are connected to the dummy feed-through in the proper way...et cetera, et cetera.) Other attached photos: the transmon table is now hanging on its own. Note that since the telescope mirrors are silvered, if you look down the axis of the telescope you can see reflections all the way up to the periscope mirrors. Also, if you look down the green path from the in-air side, you can faintly see a QPD at the other end!
We were hit by Tycor DB25 connector again.
In general, female pins are not centered in the hole (it's pretty much dependent on the tension of the cables that are attached to the pins inside), and quite often we have minor interference between male and female pin. When this happens, if we force it the pins could be broken.
Today, one of the QPD male connectors didn't want to mate with female one, and one of the male connector pins was somewhat marred by the female pin. To ease things up, I unbent the male pins so it aligns better with the female pins, which didn't help, and then removed all unused pins, which didn't help. Finally I swapped the cables with male pins (basically swapped green and red QPD cables connecting the table and the ISI), and that did the trick.
See the picture of the disassembled connector with unused pin removed. You can see that the 6-th pin from the right top has a scar.
We still need to continue cable business, then back off all EQ stops to fully suspend it, then look at the BOSEM signals.
We might be able to have a look at the position of the telescope entrance aperture in the afternoon.
Replacement of FMCS UNC at mid Y.
Jim, Hugo
Issue:
LLO have a BSC-ISI that is under-loaded by 400lbs. They noticed that its small blades where lifted from their clamp-plates. They measured this gap by inserting shims at the blade/clamp-plate junction. A 1.5 mils-thick shim could be inserted by approximately 18/64” in the whole length of that junction.
Test:
We did the same test here at LHO on BSC6, which is reasonably loaded, in order to help LLO diagnose. The access was limited. Only two blades were tested. They could only be tested along 2” of the junction’s length.
Result:
Observations are the same for both of the blades that were tested. A 1 mil-thick shim could be inserted by approximately 28/64”, and a 2 mils thick shim could be inserted by approximately 19/64”.
Conclusion:
The gaps measured on LHO-BSC6 are similar to the ones measured on the unit studied at LLO. Hence, the space measured between the blades and their clamp-plates doesn’t seem to be a justification for a BSC-ISI to be under-loaded.
Suggestion:
Further discussion revealed that our bolts were lubricated before torqueing. Lubrication allows reaching a higher level of compression before tripping the torque wrench. It also revealed that our bolts were torqued to a higher torque value.
Higher torque allowed LLO to increase their mass budget
As the shim test performed did not appear to be impacted by the torque difference, it might be interresting to see if torque impacts the value of the thickest shim that can be inserted in that gap.
Jim, Hugo,
Gaps were re-measured today. The measurement consisted in trying to insert the thickest shim possibe in the blade/clamp-plate junction. We were able to insert a 5mils shim while LLO managed to insert a 6.5mils shim before re-torquing their blades.
The effect of torque seems more noticable at the edge of the blade/clamp-plate junction.
H1 front end racks were installed into the MSR and populated with computers. The first two of the H2 racks were installed and have front ends installed except those currently running the H2OAT.
I remotely logged in from LLO and modified the H2SUSITMY.txt file located in /opt/rtcds/lho/h2/chans/ directory, which contains the ITMY suspension control filters. I removed 4 AntiAcqL1 filters which shouldn't have been there and which may have been installed awhile back incorrectly (possibly by the prepare.m script I've since modified, possibly by someone by hand). Testing with the current suspension prepare.m script in /ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools does not generate this filter, so future use to prepare filters for other QUAD optics should not have this problem. I copied the new H2SUSITMY.txt to /opt/rtcds/lho/h2/userapps/release/sus/h2/filterfiles and checked it into the svn.