patrick.thomas@LIGO.ORG - posted 16:41, Tuesday 13 December 2011 (1900)
plots of dust counts
Attached are plots of dust counts > .5 microns. Communication was lost to the dust monitors in the LVEA for a period this afternoon when the Comtrol lost power. Communication to the dust monitor in the LVEA at location 11 (H0:PEM-LVEA_DST11_5) was lost briefly earlier to that for what I believe may also have been a glitch in the power to the Comtrol.
Non-image files attached to this report
H1 AOS
patrick.thomas@LIGO.ORG - posted 16:23, Tuesday 13 December 2011 (1897)
Ops Shift Summary
LN2 delivery
fire alarm test for H2 PSL enclosure
Paradise Water delivery
LHO General
patrick.thomas@LIGO.ORG - posted 14:21, Tuesday 13 December 2011 (1898)
dust monitors at end Y, message to operators
There should be two dust monitors in the clean room at end Y with the test mass. The signals for counts > .5 microns are H0:PEM-EY_DST1_5 and H0:PEM-EY_DST2_5. Their alarm levels are currently set at

> 0.3 microns minor: 100 major: 200
> 0.5 microns minor: 100 major: 200

They have been added to the strip tool running on the operator's station. There will be heavy mechanical work going on there to combine the two BSC chambers, so it is important to watch these and alert the crew at end Y if they spike.
H2 DAQ
david.barker@LIGO.ORG - posted 12:44, Tuesday 13 December 2011 (1896)
H2 DAQ completed

Greg, Dan, Cyrus, Jim, Dave

We completed the restoration of H2 DAQ by running the multimode fibers between both h2fw0's QFS writer and the "MSR" Sataboy to the Qlogic switches. h2ldasgw0 and h2fw0 were then turned on. Dan took a look at the systems, all are working correctly. h2fw0 is writing frames again. We will now check to see if the frequent crashing of h2fw0 with 16Hz data corruption problem is still present.

H2 CDS
david.barker@LIGO.ORG - posted 21:42, Monday 12 December 2011 (1894)
H2 Racks moved to H2EE building

Richard, Cyrus, Jim,  Greg, Dan, Ken, Dave

We moved the DAQ rack from the computer users room and the two H2 racks from the MSR to the new H2EE building. Networking (CDS and GC) and IRIG-B cables were installed. The MSR Sataboy RAID for h2fw1 and its fiber channel switches were also moved from the MSR.

All systems were powered up with the exception of the primary frame writer h2fw0. On first inspection all system appear to be operational apart from the LDAP server. Items to be completed are the connection of the LDAS fibre optics switches, the primary frame writer, the LDAP server and the tape backup system.

LHO General
patrick.thomas@LIGO.ORG - posted 17:57, Monday 12 December 2011 (1893)
plots of dust counts
Attached are plots of dust counts > .5 microns.
Non-image files attached to this report
H2 SEI
hugh.radkins@LIGO.ORG - posted 17:38, Monday 12 December 2011 - last comment - 17:36, Tuesday 13 December 2011(1891)
BSC8 ISI Optical Table In-Chamber Survey
We did a Differential Elevation Survey of the BSC8 Optical Table this afternoon.  Attached is my survey note page(just the right side.)

We observed the mon TP202 (see T1100187) which was surveyed wrt BSC2 way back.  Then looked in the chamber where Jim held the rod up against the Optical Table.  We took several shots.   I then kicked a leg of the Level and shot again and turned back to the starting monument.  My survey closed to within 0.1mm--this means I at least didn't read any numbers wrong.
All the elevation on the Optical Table were within 0.5mm.  This is good in that we leveled the Support Tubes from the outside quite awhile ago and have since pulled the iLIGO CAS stack and swapped in HEPI and the Crossbeams are currently sitting on mechanical stops.  I wouldn't have been too surprised if the table had been more out of level. I believe this puts the table very close to our requirement of within .5mrad level.  This of course can (will?) be repeated once we float the optical--we certainly can get it more level.

The average of the 5 shots on the table is 1662.6mm above BSC2(0,0,0).  That is in local elevation.  We subtract 0.1mm to put that in the Global frame.

I don't know what the Optical Table elevation should be at this point, which is good, that way you know I'm not cheating!  I'll look into this or ask someone and update you all soon!
Non-image files attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 17:36, Tuesday 13 December 2011 (1906)
According to E1100690-v8_WBSC8 Initial Alignment Procedure:

"The local BSC chamber coordinate system origin is nominally located 65.421 in [1661.7 mm] below the BSC-ISI optics table surface."
This would be the end of it except the chambers aren't necessarily exactly positioned on the global coordinate system.  The Global vertical zero is 0.1mm above the local gravity zero at BSC8-See T1100187 & T980044.  Our survey yesterday puts the Optical Table at 1662.6mm above the local level where BSC2 center is 0,0,0.  We subtract the 0.1mm from our survey result to put the elevation of the Optical Table into the global frame.  So the Optical Table is 1662.6 - 0.1 - 1661.7 = 0.8mm higher than nominal.  Not too bad since we set the support tubes 15 to 30mils high shooting the bottom side of the support tubes out side the chamber.  I was expecting some depression when the Cartridge landed but we didn't measure that as the dial indicators were no installed.

Any way, the level of the Optical Table is not to spec according to the requirement in E1100690 although I didn't think the requirement was as low as .1mrads; currently we have 0.53mrads.  However the elevation is within spec, if, if the ITM was not too far off in spec when it was measured at the test stand.  You know, the errors may combine to be fine or they may conspire to take the ITM out of position vertically.  I don't know that yet.  Regardless, the level will have to be tweaked anyway so we can fine tune the elevation as well.

If anyone doesn't understand my surveying notes or other gyrations, please feel free to ask.
H2 SUS
angus.bell@LIGO.ORG - posted 17:34, Monday 12 December 2011 (1892)
ETMY single arm test all fibres welded
Angus, Travis & Jason
Travis finished welding ETMY and it is hanging. 4th fibre was touched by a weld mirror so we replaced it. S1106462 was used in HR side left and S1106435 on AR side left (looking from HR side). We were aiming for a differential pitch (down) of 0.6 mrad and Jason measured 1.6 mrad (down), the centre of mass separation derived from the ears(?) is 602.0 mm.
H2 INS
michael.landry@LIGO.ORG - posted 12:23, Monday 12 December 2011 - last comment - 05:39, Friday 16 December 2011(1890)
A few images of the BSC8 cartridge insertion
More images to follow (we'll get an entry at ResourceSpace), but for now, some images from Betsy and myself of the Friday cartridge work.
Images attached to this report
Comments related to this report
michael.landry@LIGO.ORG - 05:39, Friday 16 December 2011 (1926)
Four more photos, these ones proofs.
Images attached to this comment
H2 CDS
david.barker@LIGO.ORG - posted 21:18, Sunday 11 December 2011 (1889)
H2 CDS shutdown started

I have started the shutdown of the CDS aligo H2 racks in the MSR and computer users room. The H2 DAQ is down. The H2 workstations will not be responsive because some file systems are down. We will complete the shutdown first thing tomorrow morning before moving the racks to the H2EE building.

H2 FMP
jodi.fauver@LIGO.ORG - posted 19:53, Friday 09 December 2011 (1888)
aHAM-11 ICC
The FTIR results are back for aHAM11 and they look good: all post work samples read below detectable. Please see the reports attached. *Note that this is one of the two chambers where there was possible contamination. 
Non-image files attached to this report
H2 INS
michael.landry@LIGO.ORG - posted 19:46, Friday 09 December 2011 (1887)
ITMY/FMY cartridge installed in BSC8
The ITMY/FMY cartridge was successfully flown today from test stand #2 in the LVEA and deposited into BSC8. The ITMY SUS fibers were confirmed afterward to be intact.  We found the payload (including ISI, the 2 SUSs and limited rigging) to be 9260 lbs, well under the crane limit. 

We will log more details, including photos, in coming entries.
LHO General
patrick.thomas@LIGO.ORG - posted 18:49, Friday 09 December 2011 (1886)
plots of dust counts
Attached are plots of dust counts > .5 microns.
Non-image files attached to this report
H2 SUS
angus.bell@LIGO.ORG - posted 16:58, Friday 09 December 2011 (1885)
ETMY single arm test first two fibre welds
Doug, Jason, Travis and Angus spent the afternoon welding in the first two fibres on ETMY. The ETM is currently set with approximately 600 microradians pitch down. Both welds were straightforward with no particular issues. S1106461 is welded in position HR side right (looking from HR side), S1106459 is at AR right (looking from HR side).
H2 DAQ
david.barker@LIGO.ORG - posted 13:16, Friday 09 December 2011 (1883)
H2 DAQ MSR Sataboy RAID lost disk

We had our first Sataboy RAID disk failure yesterday. H2 DAQ MSR SATABOY disk 7 (counting from 1) failed. Dan replaced with spare 2TB SATA disk, it is now rebuilding the RAID6 using the new disk.

Logbook Admin Feature Requests
jeffrey.kissel@LIGO.ORG - posted 13:16, Friday 09 December 2011 - last comment - 17:23, Tuesday 13 December 2011(1882)
Should be able to link to comments
Main entries have a link in the upper right corner such that one can provide direct links to log entries in emails, etc. This should also be the case for comments. Perhaps it's best if the link takes you to a page that has both the main entry, the comment itself, and any other comments associated with that entry (I fear that a direct link would show *only* the comment on the resulting page, like it does for the main entries -- I don't want this, it's imperative to see the context of the comment). However, the comment should somehow be highlighted to show that "it's *this* comment I wanted to show you."


On a related note, if you try to link directly to a comment by replacing the "callRep" at the end of any normal entry's URL for with one for a comment the page turns up blank.

i.e. Take the URL for entry 1874,
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=1874

and replace the callRep for the corresponding comment to that entry,
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=1880

and you get zilch.


Comments related to this report
jonathan.hanks@LIGO.ORG - 17:23, Tuesday 13 December 2011 (1901)
Jeff,

This is implemented in test test aLOG.  It will be moved to production in the next few days.
H2 SUS
betsy.weaver@LIGO.ORG - posted 17:18, Thursday 08 December 2011 - last comment - 17:35, Tuesday 13 December 2011(1874)
BSC8 SUS Cartridge Install Prep
This afternoon, after the final B&K hammer measurements were complete, and SEI locked the ISI and began their preps, I began securing the FMy and ITMy for lift-off.  Because the First COntact that was on the ITMy HR was many months old, and had been peeled down for IAS purposes numerous times over the last 2 months, I removed it and put a fresh coat on, including a new tab at the top.  I observed a lot of particulate on the optic after the peel and attempted to remove them with alpha swabs and the N2 gun (gun also used intermittently during FC removal).  This was cumbersome and while doing it I (and Corey over my shoulder) noticed some streaking pattern not from the First Contact, as well as some First Contact PEEK mesh patterning on the optic.  More pictures to come.  So, I gave up on the dabbing and blowing and reapplied the new FC coating.

Then, I secured all of the EQ stops on both the FMy and ITMy, with the exceptions of:
- 2 nuts (missing) - one on each UIM side stops, and
- the ITMy Top Mass Blade Stops, which require removing the Top Mass BOSEMs.  The masses and blades above and below are rock solid however, so this is fine.

I then added the new "finger" assembly which acts as a 20mm gap stop between the ITMy AR and the CP HR.  This assembly, however hangs down below the QUAD structure and may be a problem for the cartridge, but is easy to remove tomorrow if needed.

I also added the transport pins to the vibration absorbers on both suspensions.

I covered the FMy.
Comments related to this report
corey.gray@LIGO.ORG - 12:48, Friday 09 December 2011 (1880)

I took some over-the-shoulder photos of the H1ITMY as Betsy was working on it.  The photos are in ResourceSpace, here

It's hard to manually focus on the stuff we were looking at, but I think we have a few photos where we were able to capture some of the particles/marks on the surface of the optic.  Saw a little bit of everything as far as contaminants on the mirror surface:  dried liquid stains, dust particles, chunk of First Contact (due to a hole on the First Contact film), and some weird patterned ("pixel-ated" Matrix-esque) marks.

Gripes about ResourceSpace:

  • Why can't we have individual captions for every photo instead of the useless caption which just has a date & time.  I named each of my photos, so you can sorta get some info about each photo under the "Original File Name" field.
  • Wish we could edit the order the photos are arranged in Collections.
corey.gray@LIGO.ORG - 13:00, Friday 09 December 2011 (1881)

Grrrr.....yeah, it's not intuitive how to post Resource Space links (yet another gripe). 

Anyways, the REAL link for the photos I took are here:

https://ligoimages.mit.edu/?c=877

 

betsy.weaver@LIGO.ORG - 13:40, Friday 09 December 2011 (1884)
Further to Corey's elog regarding the contamination pictures of ITMy, following is my note to COC:
Yesterday, I removed the old FC from the ITMy HR and reapplied a new coating with a thin tab at the top which can be peeled in-chamber.  Corey managed to take some great pictures of this and they are posted at the link on ResourceSpace below.  (Note, the pictures are always uploaded in reverse order so the first picture is my new FC coating.)  Long story short, there are 4 things to note regarding the surface of this optic:

1) Overall particulate - lots still on the surface - like 10-20 per square inch - Ugh.  Performed the dabbing technique but gave up after a short stint because it seemed futile.  (Used lots of N2 filtered DI gun flow throughout, which helped some but not enough.)

2) PEEK Mesh pattern seen down front of optic (recall, we applied a long tab back in Oct when we bantered about the idea to tear down a strip for IAS purposes.  In the end we didn't do this and the full tab just pulled the whole top of the circle down for IAS).  You can see the "matrix" like pattern in the center of the optic in some of the pictures.

3) When I pulled the FC circle, a little square tab stayed on the optic when I got down to just below center.  Weird.  It's like it had a cut and the FC peeled around it.  I stopped pulling and pulled the circle in such a way to pull up the tab.  A small horizontal line roughly 3mm in length remained on the optic almost on center line and a 1-2 inches to the right of center (when looking at the face).

4) A very strange "watermark" was apparent streaking across the top of the optic - very apparent in some pictures.  It looked very reminiscent to me of the purple markings we observed on many iLIGO optics.  Not sure what this is.  Defect in the coating maybe - I have not looked up the CSIRO report.

As stated above, all of this was observed and then I reapplied a new FC coating as shown in picture 1 on the link.
betsy.weaver@LIGO.ORG - 16:30, Tuesday 13 December 2011 (1899)
Today, Cheryl and I re-inspected the ITMy HR surface, which now has the ~week old First Contact sheet on it.  My subsequent email to GariLynn:

Hi GariLynn -
So, the good news is, the blue streaking that ran horizontal in a band across the ITMy HR peeled off with the new FC.  The bad news is, Cheryl has pictures of a newly observed band of contaminant running around the surface of the HR surface within 1" from the edge (so outside of the FC ring).  She'll post pictures soon of today's observations.

I will indeed need to do a fresh application/pull after all IAS needs are complete in order to pull any more streaking likely to be induced when we do the pull-and-close technique a few times over the next few weeks with this new FC sheet.  Not sure how we can get away from doing this in the future - maybe we just leave it exposed?  Then we risk particulate accumulation which seems worse (as FCing over particulate may scratch, and the amount of particulate is likely to be too much to remove via dabbing).

Not sure what the new stuff is - I'll make a larger diameter FC sheet next time.

-Betsy
betsy.weaver@LIGO.ORG - 17:35, Tuesday 13 December 2011 (1905)
Cheryl's pictures from today:

https://ligoimages.mit.edu/?c=883
Logbook Admin Feature Requests
jeffrey.kissel@LIGO.ORG - posted 14:32, Thursday 10 November 2011 - last comment - 17:23, Tuesday 13 December 2011(1698)
Adding a comment should by default have the same Section and Task as main entry
Adding a comment should by default have the same section and task as main entry.
Comments related to this report
jonathan.hanks@LIGO.ORG - 17:23, Tuesday 13 December 2011 (1902)
Jeff,

This is implemented in test test aLOG.  It will be moved to production in the next few days.
Logbook Admin Bug
jeffrey.kissel@LIGO.ORG - posted 14:31, Thursday 10 November 2011 - last comment - 17:24, Tuesday 13 December 2011(1697)
Cannot Edit Comments after commit
While continuing to be logged in, after posting a comment, one should be able to edit comments that you've written in a similar fashion as the main entry.
Comments related to this report
jonathan.hanks@LIGO.ORG - 17:24, Tuesday 13 December 2011 (1903)
Jeff,

This is implemented in test test aLOG.  It will be moved to production in the next few days.
Displaying reports 86461-86480 of 88298.Go to page Start 4320 4321 4322 4323 4324 4325 4326 4327 4328 End