Displaying reports 86581-86600 of 88273.Go to page Start 4326 4327 4328 4329 4330 4331 4332 4333 4334 End
Reports until 22:24, Thursday 17 November 2011
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 22:24, Thursday 17 November 2011 - last comment - 06:11, Wednesday 28 March 2012(1753)
> 30Hz Turn Up in SUS TFs are Fundamental to BOSEMs
J. Kissel, R. Quitzo-James

In all suspension TOP to TOP transfer functions that we've taken to high frequency (i.e. > 10 Hz), we have found a confusing turn up to a slope of ~f^(1), where we expect the slope to continue to drop off as f^(-2). At the advise of one P. Fritschel, we've taken M1 to M1, OSEM basis, transfer functions of H2SUSFMY both locked and unlocked to try and explain, if not at least identify, the source of this turn up. As Peter suspected, the locked spectra show the same turn up at high frequency. Aside from the mechanical resonances left in the transfer function, this implies that there is some fundamental coupling between the OSEM Coil drive and PD sensor. It has been suggested that this coupling may arise from coil current drive mixing the PD sensing current, either at the OSEM head, or some where along the electronics chain, as these signals are on the same cable.

Note, this is not necessarily of great concern, given that we use these TOP BOSEMs for local damping between ~0.1 and 10 Hz, and perhaps for low frequency ISC offloading; all control authority will be rolled off aggressively by 10 Hz. These transfer functions are taken with basically the maximum amount of current going through the coils (to get the best SNR for the measurement), so with the fast roll off of control authority above 10 Hz, I expect this noise source will be negligible. 

Attached are two sets of plots: 
2011-11-15_H2SUSFMY_hfturnup_M1TFs.pdf -- The collection of M1 to M1, OSEM basis, H2SUSFMY transfer functions comparing the measured, suspended transfer function (GREEN) against a model of that transfer function (CYAN) composed of the production, suspended model transfer function (RED) plus the locked transfer function (BLUE). The model agrees very well with measurement, aside from some scaling factors in the F1, F2, and F3 sensors. (Details below -- **).

2011-11-15_H2SUSFMY_hfturnup_currentcoupling.pdf -- IF the mechanism is sensing current mixing with drive current, this plot shows the locked transfer functions for each degree of freedom calibrated into PD Sensing Current per Coil Drive Current. The calibration assumes the same [m/N] calibration that is always used to scale measurements (a factor of 60 for aLIGO production electronics), and then converted to current assuming a force coefficient of a 10x10mm magnet with a BOSEM coil -- 1.694 [N/A] (see T1000164), and displacement sensitivity of 62.5e-2 [A/m] (see T1100479, or T0900496).


---------------------
Details **
---------------------
The production matlab models of the aLIGO suspensions are in the EULER basis, so it took a little bit of math to get the model suspended transfer function into the OSEM basis. The math is as follows:

Assume the model, euler basis, mechanical transfer function is a 6 x 6 matrix, Pe. Hence, the 6x1, euler basis, response vector VRe, is related to the 6x1, euler basis, drive vector VDe, by
     VRe = Pe VDe                       (1)

However, we can decompose the euler basis drive and response vectors into their respective OSEM basis, using the known OSEM2EUL, oMe, and EUL2OSEM, eMo matrices:
     VRe = oMe VRo                 (2)
     VDo = eMo VDe
     => VDe = (eMo)-1 VDo         (3)

which means, that we can solve Eq. (1) for the OSEM basis transfer function,
     VRe = Pe VDe
     oMe VRo = Pe (eMo)-1 VDo
     VRo = (oMe)-1 Pe (eMo)-1 VDo  (4)

Now, this would be easy to do in matlab, IF the Pe matrix was a 2D matrix, like the OSEM2 EUL and EUL2OSEM matrices, but because Pe is a 3D matrix, response x drive x frequency, I had to do the matrix multiplication "by hand," i.e.

[ Pe (eMo)-1 ](i,j,f) = Σn  Pe(i,n,f) (eMo)-1(n,j)

[(oMe)-1 Pe (eMo)-1](i,j,f) = Σm (oMe)-1(i,m) [ Pe (eMo)-1 ](m,j,f)


This conversion of the model, i.e. exercise of brute-force math, seems have done awesomely at predicting the < 10 Hz frequency response and DC scaling of the transfer function for LF, RT, and SD, especially after including the normalization factors that are present for each OSEMINF gain to account for the OSEMs sensitivity variations. However, I'm still missing a factor of ~1.5 for the three FACE sensors that I can't figure out from where it comes. I'm not gunna bang my head against the wall about it -- the point of the measurements has been made!

--------------
Data / Analysis
--------------

Raw Data:
${SusSVN}/sus/trunk/BSFM/H2/FMY/SAGM1/Data/111115_H2SUSFMY_WhiteNoise_??_0p1to900Hz_bsfm*locked.xml
Exported Data:
${SusSVN}/sus/trunk/BSFM/H2/FMY/SAGM1/Data/111115_H2SUSFMY_WhiteNoise_??_0p1to900Hz_bsfm*locked_tf.txt

Analysis:
${SusSVN}/sus/trunk/BSFM/H2/FMY/SAGM1/Scripts/analyze_111115_H2SUSFMY_M1_lockedvsunlocked.m

Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 06:11, Wednesday 28 March 2012 (2488)
I'll provide visual evidence some time in the future, but we've now seen after installing FMY in chamber, where production electronics and properly shielded, twisted pair cabling is used, we no longer see this high-frequency turn up.
H2 SUS
betsy.weaver@LIGO.ORG - posted 21:38, Thursday 17 November 2011 - last comment - 09:04, Friday 18 November 2011(1754)
ITMy monolithic status
Today, the course pitch adjusters on the top stage of the main chain were adjusted (very iterative). After a few rounds of fine adjustments, the pitch of the ITMy was set to under 1 mRAD.

We proceeded to bring the lower reaction chain in to mate.  We pulled the FirstContact from the CP HR and cleaned off leftover particulate with swaps and the N2 gun.  I had to do an acetone wipe around the entire edge of where the FC was, in 1" from the ID of the gold coating.  I also had to do a spot acetone cleaning on a smudge at 6 o'clock about 2" in from the hold coating.not sure why the apparent FC smudge didn't come off with the sheet.

Then, we pulled the FC off of the ITMy AR. We observed a streak almost centered on the AR surface likely from the FC.  Maybe the FC was too thin here, although the sheet did not break in this location. This streak is too central on the mass, so unfortunately we will have to reapply another sheeyt,  let it dry, and pull it in hopes it picks up the smudge. We had to abort mating the reaction chain until this is finished and the AR surface is clean.  Note, we still observe particulate on the masses, even after N2 blowing.
Comments related to this report
jason.oberling@LIGO.ORG - 09:04, Friday 18 November 2011 (1756)

Some details and numbers regarding the pitch adjustments done yesterday.

Before the fine adjustments the quad hang pitch was measured:

     PUM: ~1.019 mrad down
     ITM: ~1.358 mrad up
     Differential: ~2.467 mrad
 
The UIM was adjusted and ITM pitch measured: ~2.449 mrad up.
 
Quad hang pitch was then measured after the fine adjustments were performed:
 
     PUM: ~2.983 mrad down
     ITM: ~0.243 mrad down
     Differential: ~2.740 mrad
 
 
During the fine adjustment we measured how much one full counterclockwise (CCW) turn of each of the two top mass pitch adjusters changed the ITM pitch by doing the following:
  • measure the ITM pitch
  • turn both adjusters one full turn CCW
  • measure the ITM pitch again
  • take the difference between the two pitch measurements

The resultant pitch change for one CCW turn on each pitch adjuster was approximately 436 urad down.

LHO General
patrick.thomas@LIGO.ORG - posted 18:10, Thursday 17 November 2011 (1752)
plots of dust counts
Attached are plots of dust counts > .5 microns for approximately 1 day ending around 18:00 PST.
Non-image files attached to this report
X1 SUS
jeffrey.garcia@LIGO.ORG - posted 16:52, Thursday 17 November 2011 - last comment - 17:34, Thursday 17 November 2011(1748)
QUAD 04 BUILD 03 model and medms upgraded to production style
J. Garcia, J. Kissel

The x1susquad.mdl model on the X1 SUS Test Stand was modified to match the H2 ITMY model.  The QUAD_MASTER.mdl library part from '/opt/rtcds/tst/x1/cds_user_apps/trunk/sus/common/models/' was imported and replaced the existing block in the x1susquad.mdl.  Major changes were the output OSEM drive channels were changed from "*OSEMOUTF_*" to "*COILOUTF_*".  The X1SUSQUAD.ini file was also edited to include the *COILOUTF_* filters. The new watchdog AC-coupled & band-limited filters were also implemented as in the H2 ITMY watchdogs.  

However, the Binary I/O channels and ISC input filters were terminated in the Test Stand model.

The model was re-compiled and "make installed" then the frontend rebooted to confirm changes. It's location is in:
'/opt/rtcds/tst/x1/cds_user_apps/trunk/sus/x1/models/x1susquad.mdl'.  The build location for the X1 Test Stand model is '/opt/rtcds/tst/x1/core/release/src/epics/simLink/'.  This location's "x1susquad.mdl" is linked to the actual model location above.

The x1 quad overview medm - '/opt/rtcds/tst/x1/cds_user_apps/trunk/sus/common/medm/quad/SUS_CUST_QUAD_OVERVIEW.adl' - was also modified to macro-substitute the X1 Test Stand parameters. A new SITEMAP.adl was created for the X1 Test Stand. Its location is now in '/opt/rtcds/tst/x1/cds_user_apps/trunk/cds/x1/medm/X1SITEMAP.adl'.  It only has links to the X1 QUAD medm, but future revisions will include the BSFM and other suspension builds.


Comments related to this report
jeffrey.kissel@LIGO.ORG - 17:34, Thursday 17 November 2011 (1751)
J. Batch, J.Kissel

We discovered a sneaky epics failure mode during this upgrade:
(1) Copied known function foton file from H2SUSITMY.txt to X1SUSQUAD.txt
(2) Replaced all instances of "ITMY" with "QUAD"
(3) Loaded new coefficients on X1 SUS QUAD's GDS_TP screen.

Opened up the X1:SUS-QUAD_M0_WD_OSEMDC_BANDLIM_F1 filter bank, in order to turn on the filters, but noticed that they weren't loaded, where my "figure of merit" of a loaded filter was whether there was a name inside the epics channel above the FM button (e.g. X1:SUS-QUAD_M0_WD_OSEMDC_BANDLIM_F1_Name00). A further point of confusion was that when one middle clicked on that epics field, it appeared white instead of green. Otherwise the "name" field just looked like the usual gray, empty filter bank.

It turns out, after some good detective work by Jim, he found that the filter *was in fact loaded* -- 
 - foton says it was fine
 - the message field on the GDS_TP screen (X1:FEC-10_MSG) said the coefficients were loaded 
 - when the filter FM button was hit, the readback bits when green-green (as opposed to when there is no filter in the bank, when only the first of the two bits goes green)

but the problem lie in that the test stand was using the epics-3.14.10 library, instead of the epics-3.14.10_long; an oversite in his upgrade to the test stand the other day. As in, the "name" variable for those filter banks that were "not loading" was too long, so it was left blank (and showed white upon middle click).

Once the epics softlink
/ligo/apps/linux-x86_64/
was changed to epics-3.14.10_long, (and we killed the x1susquad, and x1iopsustst1 processes, and restarted the frontend computer), the filter banks showed the filter just fine.

Sneaky, sneaky, sneaky.



/ligo/apps/lin
LHO General
jonathan.berliner@LIGO.ORG - posted 16:52, Thursday 17 November 2011 (1750)
Thursday Ops Log

- NSF Review ongoing

- NSF group tours LVEA, Staging Building, Fiber Lab, beginning at ~2pm

- Dust levels unremarkable except when tour was adjacent to BSC8

- Welding ongoing by BSC4

- ICC by HAM11

- Setting for H2 IMC chamber

- CDS folks at EY fixing h2pemey

- Squeezers going to laser hazard tonight

X1 SUS
james.batch@LIGO.ORG - posted 16:39, Thursday 17 November 2011 (1749)
Changed epics version on suspension test stand, rebooted front end.
Found epics version on front end computer was not linked to long name version.  Linked rtapps/epics on front end to correct version, rebooted front end, restarted IOP and x1susquad.  All medm data now shows up on the medm screens.
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 10:11, Thursday 17 November 2011 (1745)
Adding channels to H2SUSFMY.ini file crashes h2susb78
J. Batch, J. Kissel

Last night, I'd attempted to add

H2:SUS-FMY_M2_WIT_L_DQ
H2:SUS-FMY_M2_WIT_P_DQ
H2:SUS-FMY_M2_WIT_Y_DQ

to the stored frame builder channels, at 2048Hz, and managed to crash the front end in doing so.

My exact steps where
(1) Uncomment the above three channels (and each of their associated four lines below it),changed  acquire=1 and datarate=2048
(2) On the H2SUSFMY GDS_TP screen, I hit DAQ RELOAD, and the status changed to 0x2bad
(3) Waiting ~30 seconds (while I was trying to remember how to log into the frame builder), and the front end crashed.
(4) I could not log into the framebuilder, via the usual
telnet h2dc0 8087.

This morning, after consulting with Jim, he ran an inicheck on my edited .ini file, which gives it an OK.

controls@cdsws2:/opt/rtcds/lho/h2/chans/daq 0$ inicheck H2SUSFMY.ini
Opening input file H2SUSFMY.ini

Sample rate of system:                 16384
Longest channel name length used:         41
Total number of inactive channels:       463
Total number of active channels:         157
Total channels acquired:                 156
Total testpoints allowed:                  8
Total data rate:                     1515520

controls@cdsws2:/opt/rtcds/lho/h2/chans/daq 46$


We took the following steps to bring the computer back up:
(1) We could not log into the computer via ssh, so we moved over to the cdsimac0, and opened IPMI Viewer
   (a) On the desktop toolbar, select Apple > Recent Items > Recent Items > IPMIView20.jar
   (b) Select (double click) h2susb78
   (c) Login as controls
   (d) Select IPM Device Tab
   (e) Hit "Power Cycle"
   This, after a little bit of time, brought the front end back up with frame builder status 0x2000, as should have been originally
(2) Logged into (without problems) and restarted the frame builder 
   (a) 
       controls@cdsws2:/opt/rtcds/lho/h2/userapps/release 0$ telnet h2dc0 8087
       Trying 10.201.0.160...
       Connected to h2dc0.h2fe.ligo-wa.caltech.edu.
       Escape character is '^]'.
       daqd> shutdown
       ....
       controls@cdsws2:/opt/rtcds/lho/h2/userapps/release 0$
       
   This brought the framebuilder back up, and restored the status to 0x0
(3) Burt restored h2susfmy
   (a) controls@cdsws2:/opt/rtcds/lho/h2/userapps/release/sus/h2/burtfiles 46$ burtgooey &
   (b) Restore > Snapshot Files > Double Click h2susfmy_m1transferfunctions.snap > OK > Cancel
   (c) Restore   
(4) Look through filter banks to ensure filter coefficients have been restore / loaded properly
(5) Reset the watchdog.

Finally, now that the system is back up, I've 
(a) Confirmed the channels are visibe in dataviewer, and
(b) Taken a quick DTT spectra in the present and in the past to be sure that they're (a) visible, (b) usable, and (c) stored.
   
H2 DAQ
david.barker@LIGO.ORG - posted 09:24, Thursday 17 November 2011 (1744)
h2ldasgw0 computer swap out

Wed 11am - noon. Dave and Dan.

As part of the investigation to the QFS problem with h2ldasgw0 which causes h2fw0 to periodically crash, Dan and I swapped out the computer for h2ldasgw0 (Sun X4270). We moved the two hard drives and two FC cards from the original X4270 into the spare unit. The FC cards were installed on separate pci-e risers.

We observed no QFS errors on reboot (which was always happening with the old computer). Unfortunately at 02:24 this morning h2fw0 crashed again. I cannot find any QFS error logs for this time on the gateway. So we'll keep the investigation going.

[Thu Nov 17 02:24:13 2011] main profiler warning: 0 empty blocks in the buffer
LHO General
patrick.thomas@LIGO.ORG - posted 21:06, Wednesday 16 November 2011 (1743)
plots of dust counts
Attached are plots of dust counts > .5 microns.
Non-image files attached to this report
H2 AOS
bram.slagmolen@LIGO.ORG - posted 20:47, Wednesday 16 November 2011 (1742)
TMSY Hanging - with Safety Catchers

Bram and Craig,

Some time in the last 24h we hung the TMSY Telescope (+ ISC breadboard). We used an optical level to level the breaboard to ~0.5mrad (0.25 mm / 500 mm), in both pitch and roll. This was quit easy achieved by moving the balance masses underneath the breadboard.

Prior the hang, we measured the mass of the breadboard/Tele to 80.54 kg. A few (6x) small beam dumps are missing (and not being installed). Also, this doesn't include the partial mass of the cables coming down from above.

We installed the safety structure, which is bearly functional, but we have a few trick up our sleaves to solve this. Then we re-adjusted the BOSEMs (lateral and along the flag) to maximize range. Also the BOSEM input filters were update to set the correct offset (open_voltage/2).

open voltage F1 = 22 700 cnt

open voltage F2 = 24 100 cnt

open voltage F3 = 28 500 cnt

open voltage LF = 31 800 cnt

open voltage RT = 20 030 cnt

open voltage SD = 30 400 cnt

Simple damping loops are engaged and working. More detailed loops will be implemented in due time.

Attached are a few photos (more at https://ligoimages.mit.edu/?c=704)

Images attached to this report
H2 SUS
betsy.weaver@LIGO.ORG - posted 17:17, Wednesday 16 November 2011 - last comment - 09:34, Thursday 17 November 2011(1741)
ITMy monolithic work
After a few rounds of hanging the monolithic in the triple hang tooling and adjusting weight at the UIM, it was decided that we install just the single chain to the full QUAD and see how it hangs.  Motivation for attaching only a single chain at a time is not the baseline plan, however we have greater room to maneuver by just doing one chain at a time which was agreeable to us given the risk of having to do more gross mass adjustments over the monolithic.  We started with the reaction chain since we had the same questions with pointing tolerances with that chain on the triple hang tooling as well.  With the full reaction chain hanging on the ISI, we corrected a pitch on the PenRe (observed in a double hang) and then observed a ~2mRad pitch error on the ITMy in the full QUAD hang.  This is in the range of adjustment at the top stage so we stopped to again remove that chain and install the main chain.  Currently, the main chain (monolithic) is suspended in a triple and Jason is taking pitch readings.  We observed a large pitch error at the top mass so we will need to adjust that in the morning under the full hang (course pitch adjusters on the top mass).
Comments related to this report
jason.oberling@LIGO.ORG - 09:34, Thursday 17 November 2011 (1747)

Measured the triple hang PUM and ITM pitch after letting it settle overnight (was swinging to much yesterday evening to get accurate numbers):

    PUM: ~1.314 mrad down
    ITM: ~1.096 mrad up
    Differential: ~2.410 mrad

X1 SUS
jeffrey.garcia@LIGO.ORG - posted 16:57, Wednesday 16 November 2011 (1740)
QUAD 04 BUILD 03 lower stages cabling
Andres R., Jeff B., Jeff G.

Two of the lower stages of the QUAD 04 BUILD 03 were cabled up with the quadrapuss cables.  The BOSEMs on L1 (UIM) were confirmed on the MEDM read out as well as the AOSEMs on the L2 (PUM) stage.  All of the R0 chain masses are still locked on the earthquake stops.  Tomorrow the crew will free the masses, work on initial alignment, then attempt to center the BOSEM/AOSEMs in their center of range.
X1 SUS
james.batch@LIGO.ORG - posted 16:32, Wednesday 16 November 2011 (1739)
Updated Suspension Test Stand to RCG 2.3.1
Updated suspension test stand in staging building to RCG 2.3.1.  Updated application software as well, awgstream, dataviewer, gds, mDV, and nds2-client.  Rebooted test stand, restarted iop and x1susquad models.
LHO General
corey.gray@LIGO.ORG - posted 15:57, Wednesday 16 November 2011 (1738)
Ops Day Shift Summary

Summary:

Along with the first day of the NSF Review, we had our first snow of the season.

Day's Activities:

H2 FMP
jodi.fauver@LIGO.ORG - posted 14:21, Wednesday 16 November 2011 (1737)
aHAM-11 ICC
Brushing is finished in the chamber and first vacuum has begun. Care was taken to change the brush when moving from section to section to reduce any possible cross-contamination. 
X1 SUS
jeffrey.garcia@LIGO.ORG - posted 13:34, Wednesday 16 November 2011 (1736)
X1 SUS QUAD 04 Looks Good, Ready for Lacing Cables
J. Garcia, J. Kissel

We have completed the first round of M0 and R0 Top2Top measurements, for X1SUSQUAD04, and they look excellent -- as good, if not better, than all other QUAD's measured in this state. "This state" is metal dummy masses, fully suspended and balanced, with only the M0 and R0 cables hooked up (i.e. no lacing cables down the reaction chain). 

See the attached .pdfs for results.

I show the best 4 suspensions in this state for comparison, 2 ITM QUADs and 2 ETM QUADs: X2 SUS QUAD 11, H2 SUS ITMY, X2 SUS QUAD 13, and X1 SUS QUAD 04; in addition to the model, which is a Main Chain model with metal dummy masses. Remember, the difference between the ITM and ETM QUADs is only in the reaction chain, in that the ITMs have the thin compensation plate (100mm thick, for 20 mm gap), and the ETMs still have the ERMs with (130 mm thick, for 5mm gap). Because the difference in thickness requires different physical parameters for the reaction chains, the dynamics are different.

This being said, one can see that X2 SUS QUAD 13, and X1 SUS QUAD 04 -- two such sus's that should be exactly identical -- show the exact same dynamics. Good!!

--------------
Data:

/ligo/svncommon/SusSVN/sus/trunk/QUAD/X1/QUAD04/BUILD03/SAGM0/
DTT Files = Data/111114_x1susquad4_bld3_M0_*_WhiteNoise_TF.xml
Exported Text Files = Data/2011-11-15_QUAD4_BLD3_M0-*_tf.txt
Gathered Results mat file = Results/2011-11-15_X1SUSQUAD04_M0.mat

/ligo/svncommon/SusSVN/sus/trunk/QUAD/X1/QUAD04/BUILD03/SAGR0/
DTT Files = Data/111115_x1susquad4_bld3_R0_*_WhiteNoise_TF.xml
Exported Text Files = Data/2011-11-15_QUAD4_BLD3_R0-*_tf.txt
Gathered Results mat file = Results/2011-11-15_X1SUSQUAD04_R0.mat


Analysis Scripts

/ligo/svncommon/SusSVN/sus/trunk/QUAD/Common/MatlabTools/
plotallquad_dtttfs.m
plotquad_dtttfs.m
Non-image files attached to this report
H2 SUS
betsy.weaver@LIGO.ORG - posted 20:57, Tuesday 15 November 2011 (1735)
ITMy Monolithic status
Today, the ITMy reaction chain was attached to the quad upper structure on the ISI. After lacing the cables down through the UIM and PUM, the chain was suspended.  At first glance, it appeared that the masses were hanging quite normal as observed by eye.  So the reweighting of the UIM while on the triple hang tooling last week in fact did set the chain somewhat appropriately. Tomorrow, Jason will give us a pitch reading off of the CP so we can assess further.
Images attached to this report
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 18:51, Tuesday 15 November 2011 (1734)
H2 SUS FMY vs L1 SUS BSFM06
A. Effler, J. Kissel

Attached is a comparison between the first two aLIGO BSFMs built. Encouragingly, the look strikingly similar!

The most significant difference is in Pitch (who's surprised?), where the first pitch mode for L1 SUS BSFM06 is 0.46, and 0.47 for H2SUSFMY. If you remember, we battled quite hard to get H2 SUS FMY where it is, see 
1297
974,
and in the end, decided that the last iteration of physical parameters on H2 SUS FMY (formerly BSFM01), resulting in the pitch mode of 0.47 was good enough. Here, with BSFM06, I know that we've incorporated all of the fixed changes (wire lengths, M3 prisms), and have built the only adjustable parameter (the blade tip heights, which determine/directly effect d1) has been set to the H2 SUS FMY value of 23.6 mm. However, the DC magnitude of the pitch transfer function is lower by a bit, and the highest resonant frequency is higher at 1.51 Hz.

We must bare in mind, that these BSFM06 measurements where taken on 111112, before it was known that the oplev mirror was causing DC pitch errors. This has sense been corrected, and data is pending, see Anamaria's entry for further details.

Further comments / recommendations to come, once we see a new set off data from BSFM 06, after OpLev mirror adjustment.
Non-image files attached to this report
Displaying reports 86581-86600 of 88273.Go to page Start 4326 4327 4328 4329 4330 4331 4332 4333 4334 End