Displaying reports 87001-87020 of 88272.Go to page Start 4347 4348 4349 4350 4351 4352 4353 4354 4355 End
Reports until 16:38, Tuesday 30 August 2011
H2 INS
patrick.thomas@LIGO.ORG - posted 16:38, Tuesday 30 August 2011 (1324)
Ops Summary
Oscar bailing tumbleweeds
Safety audit
Unifirst delivery
Return of cardboard container
Pickup of waste pallets
Fire department

plots of .5 micron particle counts attached, high counts at end X
Non-image files attached to this report
LHO FMCS
kyle.ryan@LIGO.ORG - posted 15:43, Tuesday 30 August 2011 (1323)
Correction: Started pumps at Y-end not Y-mid


			
			
LHO FMCS
kyle.ryan@LIGO.ORG - posted 15:43, Tuesday 30 August 2011 (1322)
Started MTP and QDP80 pumps at Y-mid
In preparation of venting Y-end tomorrow
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 10:02, Tuesday 30 August 2011 (1321)
X1 BSFM 01 ready to become H2 SUS FMY
After a few subtle software mysteries were solved, we've finally finished processing the M1 to M1 transfer function data taken last Tuesday on BSFM01, mounted in the assembly test area. Though the measurements do not exactly match the model*, everything looks qualitatively excellent, and I therefore approve that X1 BSFM 01 is ready to move over to mate with H2 ISI ITMY to become H2 SUS FMY.

Attached are the results (as "alltfs").

* The model was built from previously designed physical parameters, and does not yet reflect the recent changes to get the pitch mode frequency higher. Given that fact, the small discrepancies between model and measurement are understandable. We'll work toward getting a better model. More importantly, LLO is ready to suspend their BSFM, so we'll see how well it reproduces this measurement suite.

Details of the software mysteries:
Mystery #1 - Incorrect model of M1 V to V transfer function.  (see pg 1 of "mysteriessolved")
Up until recently, we had been using the Mathematica-exported Matlab model that was a closed loop, combination MIMO and SISO triple suspension model, that needed simulink to run (see T1000724-v2). In this model only some degrees of freedom were cross-coupled, only some stages had inputs, and sensor noise was included. This resulted in a confusing arrangements of inputs and outputs, so much so that we couldn't find the M1 V to V transfer function, and could only find wha looked to be the M1 to M3 V to V transfer function.
 
However, Mark had developed a fully MIMO triple model in July (with full 6x6 inputs and outputs for every stage plus 6 DOF ground inputs -- just like the QUAD model that we've been using), so I incorporated that into production QUAD-like analysis scripts. Further, because we're interested in open-loop loop transfer functions, I've stripped out all the clunky old Simulink parts. The with the new model, the inputs and outputs are all sorted out and organized nicely, so it was trivial to find the appropriate M1, V to V transfer function.

For the record, this model now lives in 
${SUSSVNHOME}/sus/trunk/BSFM/Common/MatlabTools/BSFM_Model_Production/
in which one should use the wrapper
generate_BSFM_Model_Production.m
which calls the following files
ssmake3MBf.m
    -> triplep.m
        -> BSWIRE2008_Nov.m
    -> symbexport3full.m



Mystery #2 - DC scale factor of ~100 between measurement and model for Pitch DOF.  (see pg 2 of "mysteriessolved")
The BSFM was measured using the exact same electronics (save the OSEMs themselves) as the previous QUADs. Since we haven't measured and compared any other degrees of freedom on the BSFM besides pitch to the model, I had been scaling the measurement by 2.7, and assumed this was just "the number" for the BSFMs. However, once I compared the other DOFs, they matched their models quite well (withing 50%) by scaling the measurements by the same factor of 225 used on the QUADs (which in retrospect is obvious). This screamed of some software bug, which after glancing over the OSEM2EUL and EUL2OSEM matrices, I noticed the Pitch matrix elements were quite small (they should typically be the largest coefficients in the matrix). I traced the route of this problem back to the script that calculates / defines these matrix elements, 
${SUSSVNHOME}/sus/trunk/BSFM/Common/MatlabTools/make_susBSFM_projections.m
and found that the distance between the F2F3 plane and F1 had been mistakenly defined to be 0.55 m (half a meter!!) instead of the actual distance of 0.055 m (or 55mm -- see attached). This factor of ten in both the OSEM2EUL and EUL2OSEM matrix explained away the factor of 100. I corrected the script, and repopulated the matrices, retook the pitch measurement, and voila! 
 
The data / xmls for this measurement suite can be found in
${SUSSVNHOME}/sus/trunk/BSFM/X1/BSFM01/BUILD02/SAGM1/Data/110823_1900_X1SUSBSFM01_WhiteNoise_*.xml
Note that the re-measurement of the pitch degree of freedom after the matrix corrections is
${SUSSVNHOME}/sus/trunk/BSFM/X1/BSFM01/BUILD02/SAGM1/Data/110829_X1SUSBSFM01_WhiteNoise_P_0p005to50Hz.xml
Non-image files attached to this report
H2 INS
greg.grabeel@LIGO.ORG - posted 09:58, Tuesday 30 August 2011 (1320)
HEPI BSC 6 Installation

BSC 6 HEPI installation is now nearly complete. Housings are in place with the positioned support tubes, horizontal and vertical actuators are installed, and most of the plumbing is in place.

The actuators will require spacers to be installed and the socket screws to be torqued to final value. However, doing so will wait until after the cartridge install.

Images attached to this report
H2 DAQ
david.barker@LIGO.ORG - posted 17:11, Monday 29 August 2011 (1319)
H2 upgraded to RTS tag-2.3.1

I upgraded the H2 DAQ systems to RTS version tag-2.3.1 this morning between 11am and 12:20pm. All sytems were recompiled, including mbuf, mx_streams and the DAQ system (dc, rcv, nds). All computers were restarted.

H2 INS
michael.rodruck@LIGO.ORG - posted 16:53, Monday 29 August 2011 (1318)
H2 PSL installation

The H2 diode room back wall (the LVEA wall) was painted and doors were installed in the diode and chiller rooms. More panels put up in the acoustic enclosure and anteroom. Perforated panels were also installed in the anteroom, to allow for airflow.

Dust levels are good.

Images attached to this report
H2 General
jeffrey.garcia@LIGO.ORG - posted 16:39, Monday 29 August 2011 (1317)
Ops Day Summary
Throughout the day:
SEI install work at End-Y

11:00 – Patrick installing new dust monitors

3:00pm – contractors using SW roll-up for moving to and from End-Y

4:00pm - Swageloc contractor on-site to see Hugh R.
H2 General
jeffrey.garcia@LIGO.ORG - posted 16:37, Monday 29 August 2011 - last comment - 17:41, Wednesday 31 August 2011(1316)
First H2 ITMY Quad R0 suspension Transfer Functions
J. Kissel, J. Garcia

The attached pdf includes plots of the open-loop transfer function measurements as well as the model for each Euler-basis degree-of-freedom of the top mass reaction chain (R0).  The plots display the calibrated measurement of the open loop transfer function from the test excitation channels ('H2:SUS-ITMY_R0_*DoF*_EXC") to the Damping filter inputs ('H:SUS-ITMY_RO_*DOF*_IN1_DQ').  Initial measurements agree quite well with the models.  More analysis and more measurements to come.  The measurement was conducted last Friday morning with the BSC-ISI Damping loops ON.
Non-image files attached to this report
Comments related to this report
jeffrey.garcia@LIGO.ORG - 17:41, Wednesday 31 August 2011 (1328)
To clarify a few items:

1.) These are not the first H2 ITMY QUAD R0 Transfer Functions in general, rather these are the first since the mating of the QUAD to the BSC-ISI.  

2.) The Damping Loops of the BSC-ISI were ON, but local damping of the QUAD was OFF.

3.) I should note the location of the data and scripts used to plot and take the data.

All data and scripts are in the SUS SVN --> '/ligo/svncommon/SusSVN/sus/trunk/' under the following sub-directories:

The data file for this measurement is in '~/trunk/QUAD/H2/ITMY/SAGR0/Data/' with
filename = "2011-08-25-998352104_H2SUSITMY_R0_0p01to50Hz_AllDOFs_tf.mat"

Script for data collection in '~/trunk/QUAD/H2/ITMY/SAGR0/Scripts/'
file name = "collectTF_20110825_H2SUSITMY_R0_0p01to50Hz_AllDOFs.m"

Script for plotting in '~/trunk/QUAD/Common/MatlabTools/'
file name = "plotquad_matlabtfs.m"
H2 INS
patrick.thomas@LIGO.ORG - posted 15:43, Monday 29 August 2011 (1315)
H1 PSL dust monitor
I swapped the Met One 227B dust monitor at the H1 PSL with a Met One 6003 to test if the Met One 6003 would work with the existing code and RS 485 loop. I have put the previous dust monitor back, restarted the code, and reset the alarm settings.
H2 General
jeffrey.garcia@LIGO.ORG - posted 15:13, Monday 29 August 2011 - last comment - 17:37, Wednesday 31 August 2011(1314)
First H2 ITMY Quad M0 suspension Transfer Functions
J. Kissel, J. Garcia

The attached pdf includes plots of the open-loop transfer function measurements as well as the model for each Euler-basis degree-of-freedom of the main chain (M0).  The plots display the calibrated measurement of the open loop transfer function from the test excitation channels ('H2:SUS-ITMY_M0_*DoF*_EXC") to the Damping filter inputs ('H:SUS-ITMY_MO_*DOF*_IN1_DQ').  Initial measurements agree quite well with the models.  More analysis and more measurements to come.  The Reaction chain (R0) transfer functions were conducted on Friday as well, results to follow.

The measurement was conducted last Friday morning with the BSC-ISI Damping loops ON.
Non-image files attached to this report
Comments related to this report
jeffrey.garcia@LIGO.ORG - 17:37, Wednesday 31 August 2011 (1326)
To clarify a few items:

1.) These are not the first H2 ITMY QUAD M0 Transfer Functions in general, rather these are the first since the mating of the QUAD to the BSC-ISI.  

2.) The Damping Loops of the BSC-ISI were ON, but local damping of the QUAD was OFF.

3.) I should note the location of the data and scripts used to plot and take the data.

All data and scripts are in the SUS SVN --> '/ligo/svncommon/SusSVN/sus/trunk/' under the following sub-directories:

The data file for this measurement is in '~/trunk/QUAD/H2/ITMY/SAGM0/Data/' with
filename = "2011-08-25-998323873_H2SUSITMY_M0_0p01to50Hz_AllDOFs_tf.mat"

Script for data collection in '~/trunk/QUAD/H2/ITMY/SAGM0/Scripts/'
file name = "collectTF_20110825_H2SUSITMY_M0_0p01to50Hz_AllDOFs.m"

Script for plotting in '~/trunk/QUAD/Common/MatlabTools/'
file name = "plotquad_matlabtfs.m"

H2 INS
hugh.radkins@LIGO.ORG - posted 17:10, Friday 26 August 2011 (1313)
HEPI Housing & Actuators at EndY BSC6
GregG & EricA

We had a bolt gall in the Pier top so that cost a good 1/2 man day.  But that is mostly over now and we proceed.  Five of the eight Actuators are in place and we are on track to complete Monday.  Can't give a welding update at this time.

-Hugh
H2 General
michael.rodruck@LIGO.ORG - posted 16:34, Friday 26 August 2011 (1312)
Ops Day Summary
H2 INS
michael.rodruck@LIGO.ORG - posted 16:19, Friday 26 August 2011 (1311)
H2 PSL installation

Electrical wiring was worked on today, HEPA units brought over to the clean rooms and more paneling work.

Dust levels are good.

Images attached to this report
LHO FMCS
kyle.ryan@LIGO.ORG - posted 15:18, Friday 26 August 2011 (1309)
Leak tested new conflat joints at X-mid
Helium leak tested (4) new 10" conflat joints and (1) new 2.75" joint on GV14 adapter spool (iLIGO viewports removed, (3) blanks and (1) 10"-2.75" zero-length reducer installed) -> new joints are good but found a 4x10-7 torr*L/sec leak on nearby original iLIGO blank -> Cinched flange fasteners and leak improved to 1x10-7 torr*L/sec
LHO FMCS
kyle.ryan@LIGO.ORG - posted 15:10, Friday 26 August 2011 (1308)
Vertex Volume leak found
John, Kyle 

Found 1x10-3 torr*L/sec leak on pump side of 10" gate valve at Main Turbo Pump inlet (stem bellows area) -> Closed valved and valved-in IP1, 2, 3 and 4.  Also, valved-in HAM6 500 L/sec ion pump -> Vertex pressure normal now.  Will replace valve during next Vertex vent.
H2 SEI
richard.mittleman@LIGO.ORG - posted 13:59, Friday 26 August 2011 (1307)
ITMY Damping Loops

  I've turned on the damping loops, they work as a set (all 12) or one at a time, excpet for  Stage 1 rZ  which is not stable at ~11.5Hz when it is the only loop on

H2 SEI
richard.mittleman@LIGO.ORG - posted 13:10, Friday 26 August 2011 (1306)
ITMY ISI Transfer Functions

ITMY-ISI Tranfsfer Functions With a Quad

The Badness on stage one (19-30 peaks)  is only seen in the CPS and not the L4Cs so is presumably the test stand.

There is a not enormous cluster of peaks around 265-270 on the St1-> L4Cs TFs which are probably the spring resonance 

For the lower frequency data set, Stage 1, V2 actuator was unplugged

Non-image files attached to this report
H2 General
jonathan.berliner@LIGO.ORG - posted 17:29, Thursday 25 August 2011 (1303)
Thursday Ops Log
- Surveying work by BSC7.  Clean room not placed on it.
- BSC8 ICC complete, floor replaced, dome replaced.
- Kyle completes leak checks in HAM4, HAM5, HAM6 area.
- IAS work at EY, BramS, SamW, MattE presiding.
- SUS crew working by test stand.
- King Water arrived to work on RO.
H2 SUS
filiberto.clara@LIGO.ORG - posted 16:05, Tuesday 23 August 2011 - last comment - 15:24, Friday 26 August 2011(1278)
H2 SUS PUM Monitor Channels
Had issues with the signal input selection monitor bits for the PUM. A test bit controls where the drive signal for each channel comes from. The PUM has two DB9 connectors, "DRIVE IN" or "TEST IN". See Jeff Kissel Alog - QUAD BIO I/O Simulink/MEDM Upgrade for further details.

This test bit controls a relay that selects from "DRIVE IN" or "TEST IN". Attached to this circuit are two transistors that output the state of the relay. When the relay was activated, it would respond by switching. The problem came from the rest of the circuit, where the input voltage on this bit was around 0.8V. This was enough voltage to keep the base of the transistor "on" regardless of the state. Jay Heefner recommended we switched out R111 on all four channels from 10K to 100K. Did modifications on PUM Chassis SN S102650. Unit is back in SUS rack and monitor channels are all working.

F. Clara, J. Heefner, R. McCarthy 


Comments related to this report
filiberto.clara@LIGO.ORG - 15:24, Friday 26 August 2011 (1310)
Correct SN of Chassis is S1102650.
Displaying reports 87001-87020 of 88272.Go to page Start 4347 4348 4349 4350 4351 4352 4353 4354 4355 End