Terri S., Christina -> Cleaned and prepped HAM8 and HAM9 work area Kyle, Ski, Zak+Rodney (Manpower), Chris (Apollo), Gerardo Jr. -> Removed HAM8 and HAM9 west doors. Kyle -> Opened GV8 and GV6
Shifted over to Chiller 3 and CWP3 following a shutdown of Chiller 1. Investigating cause.
Happy Thanksgiving!
Kyle-Removed all but (4) loosened bolts from HAM8 and HAM9 West doors in preperation for removal tomorrow*Isolated Vertex MTP*Resumed roughing XBM*Switched XBM to MTP*Restored Vertex MTP*Began pumping HAM6 with its turbo*misc. annulus ion pumping X-end pumping flat->no access (tumbleweeds)->will investigate/fix as soon as road reopens. Will likely relieve CP1 and CP2 H2 pressures before long weekend.
Highlights: -Richard and DaveB working on moving PEM channels and issues with end-station communications -staged for tomorrow's entrance into HAM8 and HAM9 -craned ISCT10 over Y-Beam Manifold -craned garb room into the LVEA diagonal -loosened bolts on HAM8 and HAM9 for tomorrow's opening of HAM8 and HAM9 -Tomorrow - 8:15am meeting, first order of business is clear HAM8 and HAM9 1057 - Dave calls to say that he's moving PEM channels from h2adcupem -> h2adcusus 1203 - Sheila goes out to turn squeezer back on 1205 - Praxair at MY 1455 - Squeezer Laser is on
Sheila Dwyer notified the Control Room at ~2:55pm that the laser has been turned on. Please follow the relevant safety precautions for Squeezer operation until further notice.
Kyle-Installed remaining bolts and torqued BSC7 east door*Closed GV4*Isolated Diagonal Volume from Purge Air*Pumped GV4 gate annulus volume*Pumped to <100 torr XBM with EDP200*Isolated Vertex MTP*Used Vertex QDP80 to continue pumping XBM to 7 torr*Isolated pumps from XBM (will finish tomorrow)*Restored Vertex MTP to continue pumping Vertex volume Kyle-Finished roughing down HAM6 (had started Friday?
Activities: HAM 8 & 9 cleaning move ISCT10 meatlocker to H1 bay for squeezers move ISCT4 enclosure table ~9:35 squeezer laser turned on ~12:05 squeezer laser turned OFF ~1:25 – Ski and others begin moving meatlocker and table by ISCT10 and the table under it. Door Access alarms: Y-end door alarm 10:05 - east bay emergency egress door medm alarms: FMCS - Annulus Ion Pump – periodically
Due to the winter storm weather we are having, the Staging Building temperature dropped over the weekend to 60 deg F. Both chains rose in height enough that all 4 top OSEMs were near or at 0 OLV. Resetting temperature controls in the building restored the OSEM/chain alignment as the temperature came back up to ~70 deg F over the last few days.
Started one or more sets of heaters in out buildings. Turned heat on in Staging and Warehouse. Will have to monitor and possibly reprogram thermostat for winter use. Shut outside air dampers down on Staging building to help maintain temp. Replaced battery on tractor. Bailing tumbleweeds still/
I changed the startup script for dataviewer on bscteststand to use 10.11.0.25 for a server instead of "teststand0" which doesn't exist.
Kyle, Zack, Rodney - Hung BSC7 east door on chamber. Kyle - Began pumping Vertex and HAM6 volumes. Kyle - Switched Y-end from MTP to Ion pump, spun MTP down, shut-down QDP80
We realigned and balanced Quad 2 after adding weight to the test masses to account for the increase weight of the glass masses. We had to replace the three lower wires on the Main Chain due to stretch. Found the flags for the UI OSEMs need to be installed and run in at least half way to attain proper pitch. We characterized all magnets and checked polarity per E1000617. BOSEMs on the Top mass have been tested for full range function and are set to their mid points. We will start testing the Top Mass BOSEMs on Monday. Notes: (1). The blade stop bolts must be run down so the head is below the level of the magnet holder. If not they will interfere with the left and right BOSEM alignment. (2). Watch the side magnet and flag, as it is prone to hanging on the BOSEM, causing misalignment. (3). Be sure to square and level the Table Cloth before adjusting the BOSEMs. This is especially important for the correct positioning of the left and right BOSEMs. Failure to set the Table Cloth properly can cause the BOSEM to push down on the Top Mass, throwing off the alignment of the other BOSEMs.
Cheryl removed optics from BSC7 Kyle put door back on BSC7 More squeezer work Truck jackknifed on Rt. 10
Where it will find a new home in the physics building atrium display case.
The controller, pressure regulators, and other hardware are stored in a plastic box with the legs. Ballast tanks and tripods are on a second pallet. Both pallets are in the 4k PSL bay.
There is now a dust monitor back in the bake room, using the spare I had for testing. I have given it back location #3, and set the location of the one in the control room from #3 to #4.
- Zack, Rodney, Cheryl Removed weights (140 lbs) and steering mirror from the optics table. We then removed all of the auxiliary equip. used to remove large optics (lazy susan, lift table). Final cleanup and storage of equipment will take place after Kyle and crew has put on the door.