Displaying reports 87961-87980 of 88272.Go to page Start 4395 4396 4397 4398 4399 4400 4401 4402 4403 End
Reports until 12:51, Monday 15 November 2010
H2 General
jonathan.berliner@LIGO.ORG - posted 12:51, Monday 15 November 2010 (333)
Mid-Shift Ops Report
Times in PST:
0903 - Input violation, clean room roll-up door
0934 - Richard out to high bay roll-up door, swapping input/output card-readers to diagnose card-reader issues
1024 - Door Forced, LVEA
1050 - Oscar begins patching holes in the concrete on the top of the Y-Arm beam tube.
1103 - Gerardo out to LVEA to look at hole template for HAM chambers
1230 ~ H2 ITMY, H2 FMY removed to OSB clean room
H2 General
jonathan.berliner@LIGO.ORG - posted 09:12, Monday 15 November 2010 (332)
Open Work Permits
2608 - Kyle - BSC8 Vacuum work
2607 - Keita - Squeezer prep
2604 - Kyle - BSC9 remove east door install pump
2595 - Kyle - BSC10 vent
2594 - Hugh - HEPI Actuator flushing
2589 - Kyle - BSC6 work
2588 - Patrick - IOC work
2581 - Kyle - Remove BSC1 south door
2574 - Cheryl - Remove H2 TCS
2571 - Richard - Remove H2 electronics
1793 - Richard - Install temporary patch fibers at MX and MSR
2566 - Dave - Remove H2 Channels from frame
2530 - Robert - Infrasound at EX

When complete, please sign out the permit.
H2 INS
michael.landry@LIGO.ORG - posted 07:09, Monday 15 November 2010 (331)
BSC8 deinstall status
(Cheryl, Patrick, Mitchell, Jim, Jodi, Mike)

Status in BSC8 as of Friday 4:30pm: Once the BSC door was removed, the team locked down ITMY and FMY, removed OSEMs, and began extracting auxiliary components such as black glass beam dumps and associated (unwieldy) aluminum structures. Several of the latter had galled bolts which had to be snapped to remove.  Hardware for the removal of optics and LOS structures was staged in-chamber.  We expect to complete this work today Mon 15th.
H2 General
jeffrey.garcia@LIGO.ORG - posted 15:57, Friday 12 November 2010 (330)
Ops Day Summary
8:15 - Electrician out in the LVEA

Ski, Richard, Jodi, and others moving a clean room near the PSL

Patrick to End X to replace dust monitor cabling

11:31 – error entering LVEA - unnamed card (#508) 

12:00 - Gerardo arrives in 1 ton truck with delivery

~12:25 – card reader error – undeclared card into Large Equipment Main Door

~12:33 – card reader error – undeclared card into Large Equipment Main Door – 3 times within a 2-minute span

12:45 - Patrick returns from End X

~1:00 - beginning of staging and removal of BSC8 door and removal of optics.  This work continues at the end of the day.

LHO FMCS
kyle.ryan@LIGO.ORG - posted 18:15, Thursday 11 November 2010 (329)
X-end & YBM
X-end air <-54C when measured with purge line decoupled and 1psig air blowing out from VE into the room, i.e. OK now -> began pumping X-end.

Pumped YBM+Y1 with YBM MTP for ~2 1/2 hours to partially remove ~3 weeks of accumulated H2 from CP3, Y1 and CP1 -> Vented YBM, removed all but (4) bolts from BSC8 south door.
H2 INS
filiberto.clara@LIGO.ORG - posted 15:46, Thursday 11 November 2010 (328)
Uninstall of H2 Electronics
R. McCarthy, C. Reed, F. Clara, Zack & Rodney (manpower)

Finish removal of cable trays around H2. Not all cable trays around BSC8, BSC4, BSC1, BSC2, and BSC7 were removed, since H1 / access system cables are still running on some cable trays. Moved H2 PSL racks away from the PSL table.
Images attached to this report
LHO FMCS
mark.lubinski@LIGO.ORG - posted 07:24, Thursday 11 November 2010 (327)
LSB Chiller
Completed swap of front panel for LSB Chiller
H2 General
jonathan.berliner@LIGO.ORG - posted 21:50, Wednesday 10 November 2010 (326)
Wednesday Ops Log
Times in PDT:
0908 - SnowVally arrives.
0909 - Door Forced, LVEA
0936 - Clean Room Roll-Up Door Alarm
0936 - Door Forced, LVEA
0947 - Patrick to outbuildings to measure cable length
1040 - Keith Thorne starts nscd daemon on control6 to speed up file-system
1049 - SnoVally returns
1109 - Door Forced, LVEA
1136 - Door Forced, LVEA
1158 - Wood recycling arrives
1213 - CDS filesystem is so slow today
1222 - Ski's delivery from Tate(?) comes
1427 - Input Violations, MY or EY
1452 - Door Forced, LVEA
1500 - All-Hands Safety Meeting hosted by David Nolting
1739 - OSB Doors Locked
H2 INS
gerardo.moreno@LIGO.ORG - posted 20:30, Wednesday 10 November 2010 (325)
H1-ITMY Optical Lever Laser is off
Laser is off.
Done to aid the H2-ITMY/FMY de-install team.
LHO FMCS
kyle.ryan@LIGO.ORG - posted 18:00, Wednesday 10 November 2010 (324)
X-end & Y-mid
X-end - Previous attempt at drying X-end volume (see entry from 11/9/2010) was too laborsome for minimal benefit -> Tried different approach today.  Roughed down volume to <100 torr then backfilled to ~1 psig with dry air this resulted in -35C air blowing out of VE when purge line decoupled -> Repeated exercise this time going down to <10 torr then backfilling -> will pump X-end normally tomorrow. 

Y-mid - Shutdown Y-mid turbo and QDP80
H2 General
betsy.weaver@LIGO.ORG - posted 09:34, Wednesday 10 November 2010 - last comment - 15:05, Wednesday 10 November 2010(322)
Q2 M0 alignment
Yesterday we finished resetting height and pitch of the Main Chain on Q2 after the mega mass swap.  The TM is now sitting at at a hint over 22mm (21.7mm nom) from the LS bracket fiducial and the pitch error is 0.5mRad (2mm of beam displacement at the wall/4m lever arm from Q2 to wall) based on the optical lever.  So, we are within spec on both of these numbers.  We're moving on to the Reaction Chain and then will look at yaw and gap.
Images attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 15:05, Wednesday 10 November 2010 (323)
Moving to R0, we see that we are pitched out at the PenRe causing the lower bump stops to touch the Pen on M0.  Looking closer at both chains, it seems the pitch error is at the UIM/Pen stage on both chains.  

The R0 UIM needed 100g moved from front to back on the mass in order to be better leveled.  This was achieved by the following.
R0 UIM - took off:
25g + 100g on top front turret
25g on back top left turret
50g 1st from cntr of 3 on right front top plate

replaced it with:
37g + 37g on top front turret
75g on back top left turret
100g 1st from cntr on left back top plate

After all of this, we adjusted out the pitch error seen in the Top Mass with the course pitch adjusters.  We noticed that the R0 right adjuster looked off center compared to the left one, so we adjusted this one side which corrected pitch and looked more in line with the COM.

Next we saw that R0 hung low by ~2mm and was also side shifted from M0 by ~1mm to the right (viewed from back).  We added a 1.5mm shim set (total now = 3.5mm) to the left Top Stage Blade and a 0.5mm shim to the right (total now = 0.5mm).

A final tweek to one of the R0 Top Stage Blade cartridges to adjust out a little yaw left the TM and the ReTM with a nice 5mm +/- 0.5mm gap.

Tomorrow we will revisit M0 to adjust out some minor pitch error at the lower masses.  
LHO FMCS
kyle.ryan@LIGO.ORG - posted 17:13, Tuesday 09 November 2010 (321)
End Station Status'
Kyle, Chris (Apollo)-Installed BSC9 east door at X-end

Kyle, X-end - IP12 controller died last night as room was too warm with QDP80 and all (5) of the purge air compressors running (BSC9 door off soft cover on - typically purge flow is set to max when door and soft cover are both off then reduced when soft cover is installed)  Also, purge air drying tower had switching failure this morning and dewpoint measured -13C -> Investigation showed that "purge air valve" which dictates air pressure on tower which is regenerating dessicant was set at ~95psi -> corrected by setting value to 65psi - this alone will cause ultimate "dryness" to be poor.  Additionally, deduced that 1of4 gravity-style check valves was stuck open - this would be the source of the switching failure -> whacked check valve body with knuckles during portion of cycle when air flows "against the arrow".  This freed the stuck flapper and now ok -> Purge air system Ok now measure <-54C comming from supply but ~-17C when blowing back out of VE -> Don't have good means to dry-out VE other than filling with (now) dry air then decoupling purge connection and letting VE blow out into the room, reconnect purge and refilling VE to 1psi with dry air, decoupling etc... which I did several times throughout the day.  

Note: purge air was measured to be <-54C at time X-end was vented.  95psi setting at drying tower causes inefficiency but doesn't cause noticeable problem until demand becomes high for an extended period of time.  


Kyle, Y-end - Finally have good vapor pressure at Y-end LN2 dewar (new value is 6 turns ccw from fully closed economizer valve adjuster screw) -> no more "low N2 flow" alarm on QDP80 -> Resumed pumping Y-end.
H2 INS
patrick.thomas@LIGO.ORG - posted 16:32, Tuesday 09 November 2010 (320)
Ops Day Summary
8:03 - 11:34 Oscar patching mouse holes along the Y arm
8:34 - 8:57 Dani transitioning end X to laser safe
9:49 Unifirst delivery
10:19 Praxair delivery to mid Y
10:37 ISCT9 being moved to squeezer experiment
10:49 gravel truck arrives
? another gravel truck arrives

Other work:
Christina, Terry cleaning BSC8 and surrounding area
Sheila, Keita, Dani, Conor, Daniel assembling squeezer experiment
Filiberto continuing CDS deinstall
Rolf, Alex, Keith here to help H2 CDS install
Door is back on end X
Work continues on the foundation for the H2 electronics building
LHO FMCS
mark.lubinski@LIGO.ORG - posted 15:17, Tuesday 09 November 2010 (319)
site inspection
Completed site inspection tour, found no problems
Replaced battery for FMCS system.  FMCS is now restored to full operation.
H2 INS
richard.savage@LIGO.ORG - posted 19:50, Monday 08 November 2010 (318)
H1 ETMX Pcal laser shut down
JonathanB and RickS

We completed our work here at EndX and shut down the photon calibrator laser.

The EndX VEA is still, however, in the Laser Hazard condition.

Hopefully DaniA will transition us back to Laser Safe tomorrow morning.
H2 INS
richard.savage@LIGO.ORG - posted 19:36, Monday 08 November 2010 (317)
Lock down of H1 ETMx
JonathanB, PatrickT, RickS

Following Doug Cook's instructions, we locked down H1 ETMX (RickS) inside the chamber by screwing in the four rear earthquake stops until the touched the chamfer on the rear of the ETM and nudged the optic up against the earthquake stops on the front face chamfer.
H2 INS
richard.savage@LIGO.ORG - posted 19:33, Monday 08 November 2010 (316)
Photon calibrator measurements at EndX
JonathanB, Patrick, RickS

After locking down H1 ETMX, we proceeded to measure the optical efficiency from the photon calibrator output to the light incident on the ETM - basically just the viewport transmission.  Measurements were made about 35 cm upstream of the ETM using the Woring Standard power sensor (integrating sphere and InGaAs PD).  We did not use the TEC controller due to cable length issues.

We used the Pcal internal power monitor (PM)as a laser power reference.  We measured the PM voltage using a Keithly 2100 VOM connected to the Blue Box PD out.  The WS voltage was measured in the usual way.  Typical measurements were two minutes long with one sample every 25 ms.

The H1ETMx pcal beams do not cross, so the Pcal refl beam impinges on the mass on the -y (east) side.

For the in-chamber measurements, the WS/PM ratios were:
Pcal refl beam: 0.2788, 0.2781; avg = 0.2785
Pcal trans beam: 0.2828, 0.2831; avg. = 0.2830

Before going into the chamber, we measured the WS/PM ratios with the WS located inside the Pcal calibration box (just upstream of the vacuum window).  Note that the TEC was used for these measurements.  The ratios were:
Pcal relf beam: 0.3239, 0.3190; avg. = 0.3215
Pcal trans beam: 0.3253, 0.3201, 0.3176; avg. = 0.3210

After the in-vacuum measurements, we repeated the external measurements, but this time without using the TEC.  The results were:
Pcal refl beam: 0.3159, 0.3145; avg. = 0.3152
Pcal trans beam: 0.3168, 0.3176; avg. = 0.3172

Using the data taken wihout the TEC (we don't expect it to make a difference, but just in case ...) we get for the optical efficiencies:
Pcal refl beam: 0.884
Pcal trans beam: 0.892

The optical efficiencies, for slightlyl different positions on the ETM, thus slightly different incidence angles were measured in Oct. 2007 (just after S5) to be 0.902 and 0.912.
Thus the optical efficiencies measured today are almost 2% lower than what we measured 3 years ago.





LHO FMCS
kyle.ryan@LIGO.ORG - posted 17:07, Monday 08 November 2010 (315)
X-end Vent
Kyle-vented X-end  

Kyle, Ski-removed BSC9 east door
LHO FMCS
dani.atkinson@LIGO.ORG - posted 16:13, Monday 08 November 2010 (314)
Ops Day Shift Summary
Work today included:

  • Daniel and Conor working on the squeezer setup in the east bay (no laser yet activated, should be a couple of weeks).
  • BSC9 @ EX was vented to allow for the optic to be locked down and some photon calibrator work. The area is thus still in laser hazard.
  • More electronics rack moving/sorting/packing/something at MX.
  • Initial setup for some of the future control room workstations, being initially built and tested in the computer user room.
  • Doug went to EY to see if he'd left teflon tape on the EQ stops in BSC10, which he didn't.
Displaying reports 87961-87980 of 88272.Go to page Start 4395 4396 4397 4398 4399 4400 4401 4402 4403 End